| 1.00Remote Terminal Unit (RTU) | ||||||
| 1.00 | OD67059/2025-2026:Supply and fixing Remote Terminal Unit (RTU) in the following specifications. 1) Processor of Dual ARM® Cortex® A7, or higher; Industrial use microprocessors. 2)Memory (RAM) of DDR3 RAM 256 MB, dynamic RAM or higher. 3) Storage of FIFO based storage for atleast 6 months of storage. Data to be acquired at sampling speed of 1 data/sec. 4) Events and data-logging of RTU should have internal battery backup to hold data in SOE (Sequence of Events) buffer memory and also maintain date &time.DNP3 and IEC 60870-5-104 events: 100,0005, store up to 1,000,000 events using internal file system. Store up to 100,000,000 events using USB drive or MicroSD
card. 5) Input Voltage of 12 30 VDC OR 8-16 VDC battery powered (for solar PV supply). 6) Communication Ports of Ethernet, Serial Ports, USB, Cellular Connectivity, VPN Support. 7) Ethernet Ports of 2 × 10/100 Mbps ports, 8-pin modular RJ45 jack, transformer- isolated, switched or independent ports. 8) Serial Ports of 2 × RS-232 : TxD, RxD, CTS, RTS, DCD, DTR (DB9 pin) 2 × RS-485: 2-wire half-duplex / full duplex operation,maximum baud rate 115,200 bps. 9) USB Ports of 1 × USB-A Host, 1 × USB-C Device. 10) Cellular Connectivity of via USB or serial port (External GSM/4G modem can besupported through this port) or integrated SIM port. 11)IP Protocols of Built-in protocols for communication with external devices/sensors. RS485 (Modbus ASCII & RTU protocol) , Ethernet(TCP/IP protocol) and HART protocol. 12)Screw terminals of 3.3 to 0.08 mm2 (12 to 28 AWG), solid or stranded. 13) Digital Inputs of Atleast 8 Channels, with ON/OFF voltage 12 to 24 Vdc, screw- terminal connectors. 14) Digital Outputs of Atleast 8 Channels, Form A relay contacts, 2 A at 30 Vdc, screw- terminal connectors. 15) Analog Inputs of Atleast 8 Channels: 0 5 Vdc, 1 5 Vdc, 020 mA, or 4 20 mA,12-bit resolution, unipolar, non-isolated, voltage/currentselectable by software,configurable for 30 mSec high speed update rate. 16) Analog Outputs of Atleast 2 Channels: 0 to 20 mA, 4 to 20 mA (voltage output withexternal resistor), 12-bit resolution over 0 to 20 mA range, single-ended, isolated from logic and chassis. 17) Operating Temperature of -40°C to +70°C. 18) Storage Temperature of -40°C to +85°C. 19) Shock of IEC 61131-2 ½ sine, 15 ms, 15 g. 20) Vibration of IEC 61131-2 5...8.4 Hz: Amplitude controlled, 7.0 mm (0.28 in) peak-to- peak 8.4...150 Hz: Acceleration controlled, 1.0 g peak . 21) Humidity of 5 95% relative humidity, non-condensing. 22) Protection Standard of IP20. 24) Certifications of IEC/EN 61131-2, CE Marking Compliance. 5 year Comprehensive Onsite Warranty shall be provided. | 7 | no | 3,65,000 ₹25,55,000 | 3,70,000 ₹25,90,000 | 2,68,500.01 ₹18,79,500.07 Lowest |
| 2.00SCADA Workstation | ||||||
| 2.00 | OD67741/2025-2026:SCADA Workstation with following specifications. 1) Operating System with Windows Server OS (licensed). 2) Processor with 5th Gen Intel® Xeon® Scalable Processors/3.1 GHz/ 22.5 MBto 112.5 MB Cache/ 16 to 60 core or latest. 3) Chipset with Intel C7520 or later edition. 4) Memory(RAM) with 32GB DDR5 RAM or can be expandable. 5) Storage with 4 TB HDD with 1 TB NVMe SSD. 6) Drive Bays of Front: 8 or 12 × LFF SAS/SATA/SSD or 8, 16, or 24 × SFF SAS/SATA/SSD Rear:6 × SFF rear drive optional or2 × SFF rear-drive optional or20 × SFF NVMe optional. 7) Display of 32 inch LCD. 8) Graphics of NVIDIA T1000 or AMD GPU cards (e.g., Tesla, Quadro, orRadeon). 9) Network of OCP 3.0 slot (preferred method) PCIe network card (if OCP not used or more ports needed). 10 ) Interfaces of 2 x HDMI Display Port (Front& rear), 1Gb Dedicated HPE iLO Remote Management Network Port, 1 x Front iLO Service Port, 4 x USB 3.2 Gen1 (1 x front, 2 x rear, 1 x internal), 1 x USB 2.0 (Internal). 11) Expansion Slots OF Up to 8 PCIe Gen5, and 2 OCP 3.0. 12) Keyboard & Mouse - Wireless. 13) Form factor of 2U Rack/ 19 Rack mount. 14) Power Supply of 1200W/1600W Dual hot-plug redundant Power Supplies. 15) System fan Hot-plug redundant fans, Standard Fan Kit or High Performance Fan Kit. 16 )5 year Comprehensive Onsite Warranty shall be provided. | 1 | no | 3,65,000 ₹3,65,000 | 3,70,000 ₹3,70,000 | 2,68,500.01 ₹2,68,500.01 Lowest |
| 3.00Central SCADA Server | ||||||
| 3.00 | OD67748/2025-2026:Central SCADA Server with following specifications - 1) Operating System with Windows Server OS (licensed). 2) Processor with 5th Gen Intel® Xeon® Scalable Processors/3.1 GHz/ 22.5 MB to 112.5 MB Cache/ 16 to 60 core or latest. 3) Chipset with Intel C7520 or later edition.4) Memory(RAM) with Memory type: DDR5 Smart Memory,Maximum memory: 256 GB DDR5, Memory slots: 32. 5) Storage 8TB HDD with 2TB SSD. 6) Drive Bays of Front: 8 or 12 × LFF SAS/SATA/SSD or 8, 16, or 24 × SFF SAS/SATA/SSD Rear: 6 × SFF rear drive optional or 2 × SFF rear-drive optional or 20 × SFF NVMe optional. 7) Display with 32 inch LCD. 8) Graphics of NVIDIA T1000 or AMD GPU cards (e.g., Tesla, Quadro, or Radeon) 9)Network OCP 3.0 slot (preferred method) PCIe network card (if OCP not used or more ports needed). 10) Interfaces of 2 x HDMI Display Port (Front& rear), 1Gb Dedicated HPE iLO Remote Management Network Port, 1 x Front iLO Service Port, 4 x USB 3.2 Gen1 (1 x front, 2 x rear, 1 x internal), 1 x USB 2.0 (Internal). 11) Expansion Slots of Up to 8 PCIe Gen5, and 2 OCP 3.0. 12) Keyboard & Mouse - Wireless. 13) Form factor of 2U Rack/ 19 Rack mount. 14) Power Supply of 1200W/1600W Dual hot-plug redundant Power Supplies. 15)System fan with Hot-plug redundant fans, Standard Fan Kit or High Performance Fan Kit. 16)5 year Comprehensive Onsite Warranty shall be provided. | 1 | no | 6,10,000 ₹6,10,000 | 5,40,000 ₹5,40,000 | 4,47,500 ₹4,47,500 Lowest |
| 4.00NAS Server | ||||||
| 4.00 | OD67758/2025-2026:NAS Server with following specification - 1)CPU of Intel® Xeon® D-1622 4-core 2.60 GHz processor, up to 3.2 GHz. 2)Memory with System memory: 8 GB UDIMM DDR4 ECC (2 x 4GB), Memory slots: 4 x UDIMM DDR4, Maximum memory: 128 GB (4 x 32 GB). 3)Flash Memory of 5GB (Dual boot OS protection). 4)Storage with Total Internal Capacity: Up to 24 TB (12 bays × 2 TB per drive) OR, Up to 12 TB (6 bays × 2 TB per drive). 5)Drive Bay of Front: 12 x 3.5-inch SATA 6Gb/s, 3Gb/s, Rear: 6 x 2.5-inch SATA 6Gb/s, 3Gb/s. 6)Drive Compatibility with 3.5-inch bays:, 3.5-inch SATA hard disk drives , 2.5-inch SATA hard disk drives , 2.5-inch SATA solid state drives , 2.5-inch bays: , 2.5-inch SATA solid state drives. 7)Hot-swappable - Yes. 8)PCIe Slot with Slot 1: PCIe Gen 3 x4, Slot 2: PCIe Gen 3 x8 or x4, Slot 3: PCIe Gen 3 x4, Slot 4: PCIe Gen 3 x8 or x4. 9)LAN Port with 10 Gigabit Ethernet Port: 2 x 10GbE SFP+ SmartNIC port. 10)USB of 2 USB 3.2 Gen 1 port. 11)Buttons for Power, Reset. 12)LED Indicators of HDD, SSD, Status, LAN, storage expansion port status. 13)Temperature of Operating Temperature: 0 - 40 °C (32°F - 104°F), Storage Temperature: -20 - 70°C (-4°F - 158°F). 14)Humidity of 5-95% RH non-condensing, wet bulb: 27 C (80.6 F). 15)Fan wih System fan: 3 x 60mm, 12VDC. 16)Power Supply of 550W(x2), 100-
240V. 17) 5 year Comprehensive Onsite Warranty shall be provided. | 1 | no | 6,10,000 ₹6,10,000 | 5,40,000 ₹5,40,000 | 4,47,500 ₹4,47,500 Lowest |
| 5.00UPS for Servers, Storage & Workstation | ||||||
| 5.00 | OD67764/2025-2026:UPS for Servers, Storage & Workstation with following specification - 1)Output Power Capacity of 6000 W/ 6000 VA. 2)Input Voltage of 230 VAC. 3)Input Frequency of 40Hz ~ 70Hz. 4)Output Voltage of 230 V. 5)Efficiency of 93.7% at full load. 6)Harmonic Distortion of 1 % THD (Linear Load). 7)Output Frequency (sync to mains) of 50/60 Hz ± 3 Hz. 8)Topology of True double-conversion Online. 9)Waveform Type of Pure Sine wave. 10)Output Connections of 1 x Hard wire 3-wire (1P + N + E). 11) Bypass of Internal bypass (automatic and manual). 12) Input voltage limits of 176...300 VAC based on full load. 13)Battery Type of VRLA (Valve-Regulated Lead-Acid) ,Maintenance-free sealed Lead-Acid battery with suspended, electrolyte: leak-proof; 14)Runtime of Battery necessary for 30 min Backup (Built in/External). 15)Control panel of Multifunction LCD status and control console. 16)Audible Alarm of Audible and visible alarms : prioritized by severity. 17)Emergency Power Off (EPO) - Yes. 18)Surge energy rating of 600 J. 19)Colour is Black. 20)Operating Temperature of 0-40°C. 21)Operating Relative Humidity of 0 95 % non-condensing. 22)Noise level of < 50dBA @ 1 M. 23)Degree of protection is IP 20. 24)5 year Comprehensive Onsite Warranty shall be provided. | 1 | no | 1,58,000 ₹1,58,000 | 1,50,000 ₹1,50,000 | 1,16,350 ₹1,16,350 Lowest |
Tender Value
₹2.4 Cr
EMD Value
₹1 L
Closing Date
18 Sept 2025, 3:00 pmClosed
SE, P.H Circle,KWA,Trissur
PH Circle, KWA, Thrissur
AMRUT-Setting up of SCADA System for- Water Efficient Thrissur (WET) Upgrade- Providing Water Supply 24x7 to Chembukkavu DMA-Packapge IVGeneral Civil Work
2025_KWA_795735_1
RT-08/SE/PHC/ TSR/2025-26
Open Tender
Civil Works - Water Works
Item Rate
90 days
Chembukkavu
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,850
₹1 L
Yes
27 Nov 2025
10 Sept 2025
19 Sept 2025
10 Sept 2025
18 Sept 2025
10 Sept 2025
Amount
Remote Terminal Unit (RTU)
SCADA Workstation
OD67741/2025-2026:SCADA Workstation with following specifications. 1) Operating System with Windows Server OS (licensed). 2) Processor with 5th Gen Intel® Xeon® Scalable Processors/3.1 GHz/ 22.5 MBto 112.5 MB Cache/ 16 to 60 core or latest. 3) Chipset with Intel C7520 or later edition. 4) Memory(RAM) with 32GB DDR5 RAM or can be expandable. 5) Storage with 4 TB HDD with 1 TB NVMe SSD. 6) Drive Bays of Front: 8 or 12 × LFF SAS/SATA/SSD or 8, 16, or 24 × SFF SAS/SATA/SSD Rear:6 × SFF rear drive optional or2 × SFF rear-drive optional or20 × SFF NVMe optional. 7) Display of 32 inch LCD. 8) Graphics of NVIDIA T1000 or AMD GPU cards (e.g., Tesla, Quadro, orRadeon). 9) Network of OCP 3.0 slot (preferred method) PCIe network card (if OCP not used or more ports needed). 10 ) Interfaces of 2 x HDMI Display Port (Front& rear), 1Gb Dedicated HPE iLO Remote Management Network Port, 1 x Front iLO Service Port, 4 x USB 3.2 Gen1 (1 x front, 2 x rear, 1 x internal), 1 x USB 2.0 (Internal). 11) Expansion Slots OF Up to 8 PCIe Gen5, and 2 OCP 3.0. 12) Keyboard & Mouse - Wireless. 13) Form factor of 2U Rack/ 19 Rack mount. 14) Power Supply of 1200W/1600W Dual hot-plug redundant Power Supplies. 15) System fan Hot-plug redundant fans, Standard Fan Kit or High Performance Fan Kit. 16 )5 year Comprehensive Onsite Warranty shall be provided.
Central SCADA Server
OD67748/2025-2026:Central SCADA Server with following specifications - 1) Operating System with Windows Server OS (licensed). 2) Processor with 5th Gen Intel® Xeon® Scalable Processors/3.1 GHz/ 22.5 MB to 112.5 MB Cache/ 16 to 60 core or latest. 3) Chipset with Intel C7520 or later edition.4) Memory(RAM) with Memory type: DDR5 Smart Memory,Maximum memory: 256 GB DDR5, Memory slots: 32. 5) Storage 8TB HDD with 2TB SSD. 6) Drive Bays of Front: 8 or 12 × LFF SAS/SATA/SSD or 8, 16, or 24 × SFF SAS/SATA/SSD Rear: 6 × SFF rear drive optional or 2 × SFF rear-drive optional or 20 × SFF NVMe optional. 7) Display with 32 inch LCD. 8) Graphics of NVIDIA T1000 or AMD GPU cards (e.g., Tesla, Quadro, or Radeon) 9)Network OCP 3.0 slot (preferred method) PCIe network card (if OCP not used or more ports needed). 10) Interfaces of 2 x HDMI Display Port (Front& rear), 1Gb Dedicated HPE iLO Remote Management Network Port, 1 x Front iLO Service Port, 4 x USB 3.2 Gen1 (1 x front, 2 x rear, 1 x internal), 1 x USB 2.0 (Internal). 11) Expansion Slots of Up to 8 PCIe Gen5, and 2 OCP 3.0. 12) Keyboard & Mouse - Wireless. 13) Form factor of 2U Rack/ 19 Rack mount. 14) Power Supply of 1200W/1600W Dual hot-plug redundant Power Supplies. 15)System fan with Hot-plug redundant fans, Standard Fan Kit or High Performance Fan Kit. 16)5 year Comprehensive Onsite Warranty shall be provided.
NAS Server
OD67758/2025-2026:NAS Server with following specification - 1)CPU of Intel® Xeon® D-1622 4-core 2.60 GHz processor, up to 3.2 GHz. 2)Memory with System memory: 8 GB UDIMM DDR4 ECC (2 x 4GB), Memory slots: 4 x UDIMM DDR4, Maximum memory: 128 GB (4 x 32 GB). 3)Flash Memory of 5GB (Dual boot OS protection). 4)Storage with Total Internal Capacity: Up to 24 TB (12 bays × 2 TB per drive) OR, Up to 12 TB (6 bays × 2 TB per drive). 5)Drive Bay of Front: 12 x 3.5-inch SATA 6Gb/s, 3Gb/s, Rear: 6 x 2.5-inch SATA 6Gb/s, 3Gb/s. 6)Drive Compatibility with 3.5-inch bays:, 3.5-inch SATA hard disk drives , 2.5-inch SATA hard disk drives , 2.5-inch SATA solid state drives , 2.5-inch bays: , 2.5-inch SATA solid state drives. 7)Hot-swappable - Yes. 8)PCIe Slot with Slot 1: PCIe Gen 3 x4, Slot 2: PCIe Gen 3 x8 or x4, Slot 3: PCIe Gen 3 x4, Slot 4: PCIe Gen 3 x8 or x4. 9)LAN Port with 10 Gigabit Ethernet Port: 2 x 10GbE SFP+ SmartNIC port. 10)USB of 2 USB 3.2 Gen 1 port. 11)Buttons for Power, Reset. 12)LED Indicators of HDD, SSD, Status, LAN, storage expansion port status. 13)Temperature of Operating Temperature: 0 - 40 °C (32°F - 104°F), Storage Temperature: -20 - 70°C (-4°F - 158°F). 14)Humidity of 5-95% RH non-condensing, wet bulb: 27 C (80.6 F). 15)Fan wih System fan: 3 x 60mm, 12VDC. 16)Power Supply of 550W(x2), 100- 240V. 17) 5 year Comprehensive Onsite Warranty shall be provided.
UPS for Servers, Storage & Workstation
OD67764/2025-2026:UPS for Servers, Storage & Workstation with following specification - 1)Output Power Capacity of 6000 W/ 6000 VA. 2)Input Voltage of 230 VAC. 3)Input Frequency of 40Hz ~ 70Hz. 4)Output Voltage of 230 V. 5)Efficiency of 93.7% at full load. 6)Harmonic Distortion of 1 % THD (Linear Load). 7)Output Frequency (sync to mains) of 50/60 Hz ± 3 Hz. 8)Topology of True double-conversion Online. 9)Waveform Type of Pure Sine wave. 10)Output Connections of 1 x Hard wire 3-wire (1P + N + E). 11) Bypass of Internal bypass (automatic and manual). 12) Input voltage limits of 176...300 VAC based on full load. 13)Battery Type of VRLA (Valve-Regulated Lead-Acid) ,Maintenance-free sealed Lead-Acid battery with suspended, electrolyte: leak-proof; 14)Runtime of Battery necessary for 30 min Backup (Built in/External). 15)Control panel of Multifunction LCD status and control console. 16)Audible Alarm of Audible and visible alarms : prioritized by severity. 17)Emergency Power Off (EPO) - Yes. 18)Surge energy rating of 600 J. 19)Colour is Black. 20)Operating Temperature of 0-40°C. 21)Operating Relative Humidity of 0 95 % non-condensing. 22)Noise level of < 50dBA @ 1 M. 23)Degree of protection is IP 20. 24)5 year Comprehensive Onsite Warranty shall be provided.
Inkjet Printer
OD67768/2025-2026:Inkjet Printer with following specifications - 1)Type is Ink Tank System. 2) Function is Print, Scan, Copy, Fax. 3)Colour Capability is Colour (StandardCMYK). 4)Print Option with Print speed on A4 13.0 ipm black / 6.8 ipmcolour, Resolution upto 4,800 x 1,200 dpi. 5)Scan Type with Flatbed type with CIS (Contact Image Sensor) method, Automatic Document Feeder (ADF), resolution: 1,200 x 2,400 dpi. 6)Auto-Duplex Printing of Yes (automatic two-sided printing). 7)Connectivity is Hi-speed USB 2.0, WiFi, wired LAN. 8)5 year Comprehensive Onsite Warranty shall be provided.
LaserJet Printer
OD67797/2025-2026:LaserJet Printer with following specification - 1)Type is Laser printers. 2)Function with Print, Copy and Scan ADF, Duplex. 3)Colour Capability is Monochrome. 4)Print Option is Print speed up to 30 ppm (black), Resolution Up to 600 x 600 dpi. 5)Scan Type of Flatbed type & Auto Document Feeder (ADF), resolution: 600 x 600 dpi. 6)Duplex Printing with Auto-duplex. 7)Connectivity with 1x Gigabit Ethernet 10/100/1000TX network; , 2x Hi-Speed USB 2.0 (device);, Wireless 802.11b/g/n, Dual band 2.4GHz/5GHz. etc complete with a warranty period of 5 years.
Router
OD67801/2025-2026:Router with following specifications - 1)Cellular Connectivity with Dual 5G and LTE (Single or Dual Modem options). 2)SIM Slots of 2x SIM slots per modem (eSIM + physical SIM support). 3)Wi-Fi with Wi-Fi 6 (802.11ax), dual concurrent radios, 4x4 MU-MIMO. 4)Ethernet Ports of 4x Gigabit + 1x 5 Gbps (single modem) / 5x Gigabit + 1x 5 Gbps (dual modem). 5)USB Port of USB 3.1 Type-C. 6)Serial Ports with 2x RS-232 DB9 connectors. 7)Bluetooth of Bluetooth 4.x Classic (BLE optional in future firmware). 8) GNSS - 9)CAN Bus with Supports OBD-II (J1979), J1939. 10)GPIO of 5 configurable pins. 11)Input Voltage of 7 36 VDC with ignition sense. 12) Power Consumption is Peak: 68W; Standby: 55mW. 13)Housing with Rugged die-cast aluminum, IP64-rated. 14)Operating Temperature is 30°C to +70°C. 15)Management - 16)VPN Support with IPsec, IKEv1/v2, AES128/192/256, SHA256/384/512, up to 10 concurrent tunnels. 17)Certifications with UL 60950, CE, FCC, E-Mark, ISO7637-2, EN50155, C1D2, RoHS2, REACH, WEEE. 18)MTBF of ~27.5 years (Telcordia SR-332). 19)5 year Comprehensive Onsite Warranty shall be provided.
19 " Rackmount Ethernet Switch
OD67805/2025-2026:19" Rackmount Ethernet Switch with following specifications - 1)Standards and Protocols with IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x, IEEE 802.3z, IEEE 802.3az. 2)Interface with 24 x 10/100/1000Mbps RJ45 Ports (Auto Negotiation/Auto MDI/MDIX), 4 x 1G SFP Ports (for fiber connections). 3)Network Cable with UTP Cat. 5, Cat. 5e (100 m max.). 4)Switching Capacity is 56 Gbps. 5)MAC Address Table is 8K. 6) Buffer Memory is 4.1 Mbits. 7)Power Input with 100 to 240 VAC; 50/60 Hz Internal Universal Power Supply. 8)5 year Comprehensive Onsite Warranty shall be provided.
19" Rackmount Patch panels
OD67822/2025-2026:19" Rackmount Patch panels with following specifications - 1)Panel with 19" Rackmount. 2)No. of RJ45 Ports is 24 (1U). 3)RJ45 Jack with Housing: ABS, UL 94V-0, Contact Bracket: PC, UL 94V-2, Transparent color. 4)RJ45 Jack Contact with Material: Phosphor Bronze with Nickel Plated, Finish: 50 micro-inches Gold plated on plug contact area. 5)Security of Hardware firewall. 6)Connectors with Cat 5e, Cat 6 and Cat 6A. 7)5 year Comprehensive Onsite Warranty shall be provided.
19" Server Rack
OD67829/2025-2026:19" Server Rack with following specifications - 1)Type is 19" Floor standing rack with caster wheels. 2) Basic frame with Steel . 3)Capacity is 32U. 4)Depth & Width is 800x800 mm. 5)Power Extensions with 5-6 no.s of 5A surge protection power outlets. 6)Top & Bottom cover with Welded to frame with cable entry exit cut outs. 7)Front Door with Lockable toughened glass door. 8)Rear Door of Lockable meshed ventillated door . 9) No. of Shelves is 6. 10)Cable Entry at Top + bottom. 11) Fan Opening is Yes 12)Standard finish with Powder coated. 13)Standard Colour is Grey & off white or black. 14)Plates with Blank panel plates. 15)Protection Degree is IP 20.16)5 year Comprehensive Onsite Warranty shall be provided.
Flowmeters
OD67845/2025-2026:Flowmeters 200mm size with following specification - 1) Flowmeter Type with Full bore, remote mount Electronic Converter, with material of construction and coating suited for high humidity, prolonged submergence. 2)Media with Potable (Drinking) water. 3)Measurement with Flow-Rate, Totalized Flow. 4)Sensor Type is Electromagnetic. 5)Empty Pipe detection with Empty pipe electrode is desirable. 6)Installation is Horizontal pipe (outdoor installation). 7)Lining Material for flowmeter with Polyurethane (Suitable for drinking water application). 8)Accuracy is Better than ± 0.5 % of reading from 0.5 m/sec onwards. 9)Measuring electrodes material with Hastelloy. 10)Process connection type is Cl.150, carbon steel, flange ASME B16.5. 11)Protection class with Direct buried IP68, Type 6P, factory potted, corrosion protection EN ISO 12944 Im2/3. 12)Design for buried Installation/Operations At many locations, underground chambers (or meter pits) may be used for installation of flowmeters in out-door header lines. In such cases, operation under fully submerged conditions may occur during monsoons or during overflow of process media. The sensor tube, termination-box, and other parts of flowmeter shall therefore be designed for operation without failure under conditions of continual submergence for periods of 10 days or more. Submergence to depths of 2m could be common in normal operations. 13) Field terminations on flowmeter-head should be permanent protected by epoxy putty. 14)Input Mains Power supply of 24 VDC. 15)Measurement output signal type with Current output (0/4" 20mA HART);pulse/frequency/switch output; status input. 16)Operating Line Conditions of Temperature: 10 to 50°C, Pressure: 6 bar (max.) 17)Ambient Environment Temperature: 15 to 50°C, Humidity (RH): 5% to 100% condensing). 18)Material of Sensor Housing with Sheet Steel, with protective coating. 19)Material of Measuring tube Sensor is Austenitic Stainless Steel. 20)Lining Material for flowmeter is PTFE or Teflon. 21) Acceptance of Flowmeter with The Condition for acceptance of flowmeter shall include: (a) that performance of each flowmeter being supplied needs to be established through (Velocity: 0.5 m/s to 4.5 m/s) (b) The Calibration shall be performed at laboratory having ISO-17025 accreditation in India or abroad.(c) Every single flowmeter needs to be calibrated. (d) Submergence Test for the flowmeters, as per procedure mentioned elsewhere in this Tender document. 22)Grounding Connections with The sensors shall be supplied with Ground-rings, and/or with built-in electrodes for ground potential sensing in flow-tube. 23)Sample Testing for Functionality under submergence conditions of Samples from each different model of flowmeter being supplied for outdoor / underground or pit installation may be subject to test for submergence to 2m depth for a period of 8 days. 24)Approval of Non-Hazardous ACS & KTW Drinking Water Approval. 25)Housing is Remote Mount with 10 Meter Cable, Polycarbonate.26)5 year Comprehensive Onsite Warranty shall be provided.
OD71835/2025-2026:Flowmeters 100 mm with following specification - 1) Flowmeter Type with Full bore, remote mount Electronic Converter, with material of construction and coating suited for high humidity, prolonged submergence. 2)Media with Potable (Drinking) water. 3)Measurement with Flow-Rate, Totalized Flow. 4)Sensor Type is Electromagnetic. 5)Empty Pipe detection with Empty pipe electrode is desirable. 6)Installation is Horizontal pipe (outdoor installation). 7)Lining Material for flowmeter with Polyurethane (Suitable for drinking water application). 8)Accuracy is Better than ± 0.5 % of reading from 0.5 m/sec onwards. 9)Measuring electrodes material with Hastelloy. 10)Process connection type is Cl.150, carbon steel, flange ASME B16.5. 11)Protection class with Direct buried IP68, Type 6P, factory potted, corrosion protection EN ISO 12944 Im2/3. 12)Design for buried Installation/Operations At many locations, underground chambers (or meter pits) may be used for installation of flowmeters in out-door header lines. In such cases, operation under fully submerged conditions may occur during monsoons or during overflow of process media. The sensor tube, termination-box, and other parts of flowmeter shall therefore be designed for operation without failure under conditions of continual submergence for periods of 10 days or more. Submergence to depths of 2m could be common in normal operations. 13) Field terminations on flowmeter-head should be permanent protected by epoxy putty. 14)Input Mains Power supply of 24 VDC. 15)Measurement output signal type with Current output (0/4?20mA HART);pulse/frequency/switch output; status input. 16)Operating Line Conditions of Temperature: 10 to 50°C, Pressure: 6 bar (max.) 17)Ambient Environment Temperature: 15 to 50°C, Humidity (RH): 5% to 100% condensing). 18)Material of Sensor Housing with Sheet Steel, with protective coating. 19)Material of Measuring tube Sensor is Austenitic Stainless Steel. 20)Lining Material for flowmeter is PTFE or Teflon. 21) Acceptance of Flowmeter with The Condition for acceptance of flowmeter shall include: (a) that performance of each flowmeter being supplied needs to be established through (Velocity: 0.5 m/s to 4.5 m/s) (b) The Calibration shall be performed at laboratory having ISO-17025 accreditation in India or abroad.(c) Every single flowmeter needs to be calibrated. (d) Submergence Test for the flowmeters, as per procedure mentioned elsewhere in this Tender document. 22)Grounding Connections with The sensors shall be supplied with Ground-rings, and/or with built-in electrodes for ground potential sensing in flow-tube. 23)Sample Testing for Functionality under submergence conditions of Samples from each different model of flowmeter being supplied for outdoor / underground or pit installation may be subject to test for submergence to 2m depth for a period of 8 days. 24)Approval of Non-Hazardous ACS & KTW Drinking Water Approval. 25)Housing is Remote Mount with 10 Meter Cable, Polycarbonate26)5 year Comprehensive Onsite Warranty shall be provided.
OD71848/2025-2026:Flowmeters 50 mm with following specification - 1) Flowmeter Type with Full bore, remote mount Electronic Converter, with material of construction and coating suited for high humidity, prolonged submergence. 2)Media with Potable (Drinking) water. 3)Measurement with Flow-Rate, Totalized Flow. 4)Sensor Type is Electromagnetic. 5)Empty Pipe detection with Empty pipe electrode is desirable. 6)Installation is Horizontal pipe (outdoor installation). 7)Lining Material for flowmeter with Polyurethane (Suitable for drinking water application). 8)Accuracy is Better than ± 0.5 % of reading from 0.5 m/sec onwards. 9)Measuring electrodes material with Hastelloy. 10)Process connection type is Cl.150, carbon steel, flange ASME B16.5. 11)Protection class with Direct buried IP68, Type 6P, factory potted, corrosion protection EN ISO 12944 Im2/3. 12)Design for buried Installation/Operations At many locations, underground chambers (or meter pits) may be used for installation of flowmeters in out-door header lines. In such cases, operation under fully submerged conditions may occur during monsoons or during overflow of process media. The sensor tube, termination-box, and other parts of flowmeter shall therefore be designed for operation without failure under conditions of continual submergence for periods of 10 days or more. Submergence to depths of 2m could be common in normal operations. 13) Field terminations on flowmeter-head should be permanent protected by epoxy putty. 14)Input Mains Power supply of 24 VDC. 15)Measurement output signal type with Current output (0/4?20mA HART);pulse/frequency/switch output; status input. 16)Operating Line Conditions of Temperature: 10 to 50°C, Pressure: 6 bar (max.) 17)Ambient Environment Temperature: 15 to 50°C, Humidity (RH): 5% to 100% condensing). 18)Material of Sensor Housing with Sheet Steel, with protective coating. 19)Material of Measuring tube Sensor is Austenitic Stainless Steel. 20)Lining Material for flowmeter is PTFE or Teflon. 21) Acceptance of Flowmeter with The Condition for acceptance of flowmeter shall include: (a) that performance of each flowmeter being supplied needs to be established through (Velocity: 0.5 m/s to 4.5 m/s) (b) The Calibration shall be performed at laboratory having ISO-17025 accreditation in India or abroad.(c) Every single flowmeter needs to be calibrated. (d) Submergence Test for the flowmeters, as per procedure mentioned elsewhere in this Tender document. 22)Grounding Connections with The sensors shall be supplied with Ground-rings, and/or with built-in electrodes for ground potential sensing in flow-tube. 23)Sample Testing for Functionality under submergence conditions of Samples from each different model of flowmeter being supplied for outdoor / underground or pit installation may be subject to test for submergence to 2m depth for a period of 8 days. 24)Approval of Non-Hazardous ACS & KTW Drinking Water Approval. 25)Housing is Remote Mount with 10 Meter Cable, Polycarbonate .26)5 year Comprehensive Onsite Warranty shall be provided.
Ultrasonic Level Transmitter
OD67875/2025-2026:Ultrasonic Level Transmitter with following specification - 1)Measurement principle with Ultrasonic, time-of-flight. 2)Measurement range 0.2 to 8 m " Rerangeable by HART Communicator. 3)Blanking distance (dead zone) is 0.2 m/0.25 m. 4)Level resolution is Better than 1 mm. 5)Level accuracy is ± 0.1 in. (2.5 mm) 3.3 ft. (1 m). 6)Display with Digital LCD for Level/Distance, Integral display. 7)Output variables of Level. 8)Output units with Level or distance-to-surface: m, ft., in. 9)Input Power supply of 12 to 30Vdc, Loop-powered (two-wire). 10)Earthing is Protective Earth (PE). 11)Output Signal is Analog 4?20 mA output andHART communication. 12)Signal on alarm with Low = 3.8 mA, High = 20.5 mA. 13)Saturation levels is 3.8 mA. High = 20.5 mA. 14)Cable entry with Two ½" - 14 NPT conduit entries for cable glands, or Two M20 x 1.5 conduit entries for cable glands(Aluminum housing/glass-filled nylon housing). 15)Mounting thread size is 2-inch NPT / 2-inch BSP; (To be provided with clamps /fixtures). 16)Ambient temperature is ?40 to 158 °F (?40 to 70 °C). 17)Ingress protection is IP 66. 18)Certifications with CE-mark .19)5 year Comprehensive Onsite Warranty shall be provided.
Gauge Pressure Transmitter
OD67904/2025-2026:Gauge Pressure Transmitter with following specifications - 1)Pressure Range is 0 to 10 bar (g). 2) Output Signal with Two wire 4 to 20 mA DC output with digital communication (HART protocol). 3)Accuracy is ±0.05% FS or better. 4)Power Supply of 24 V DC. 5)Indicator is Integral. 6)Wetted parts material SS316 or Hastelloy. 7) Medium is Potable water. 8)Ambient temperature is 0°C to 70°C. 9)Process temperature is 10°C to 40°C. 10)Enclosure Rating is IP66/IP68. 9)5 year Comprehensive Onsite Warranty shall be provided.
Water Quality Analyzer
OD67920/2025-2026:Water Quality Analyzer with following specifications - 1)Display with An easy-to-read, backlit liquid crystal display showing Real time data.2) Installation with Wall-mounted or Rack-mounted. 3)Power Supply with 220/240V AC, 50Hz or 24V DC. 4) Ambient Conditions are Operating Temperature: 0 to 55°C (32 to 131°F) Humidity Range: 0 to 95% non-condensing Enclosure: IP65 or higher rated enclosures. 5) Measurement Parameters are pH, Dissolved Oxygen (DO), Turbidity, Residual Chlorine. a) Range- pH: 0 to 14pH Dissolved Oxygen (DO): 0-20 mg/L, Turbidity : 0.1 to 1000NTU, Residual Chlorine : 0.01 to 20.0 mg/L. b) Accuracy- pH:±0.02 to ±0.1 pH units, Dissolved Oxygen (DO) : ±0.1 mg/L or ±2% of reading, whichever is greater, Turbidity:±2% of reading or ±0.02 NTU, whichever is greater, Residual Chlorine: ±0.1 mg/L or ±5% of the reading, whichever is greater. 6) Data Output is 0 to 20 or 4 to 20mA isolated retransmission outputs. 7) Communication with RS485 serial interface/Modbus (ASCII/RTU) OR Ethernet/IP. 8) Alarms- Alarms are essential for each measurement Parameters (pH, dissolved oxygen, Residual chlorine, turbidity...) whether the parameters exceeds or drops the limits to ensure the timely detection of any water quality issues. 9) Calibration and Maintenance are Manual and automatic calibration, along with built-in calibration validation, as well as regular maintenance (such as self-diagnostics, built-in cleaning systems, etc.) for parameters like pH, Residual chlorine, turbidity, dissolved oxygen, and others. Routine maintenance includes the regular replacement of electrodes and parts. 10) 5 year Comprehensive Onsite Warranty shall be provided.
3 phase Energy Meter
OD67928/2025-2026:3 phase Energy Meter with following specifications- 1) Energy meter type is Digital Panel mounted energy meter with backlight LCD display. Class 0.5S 2) Measurement Parameters are True RMS measurement-Current, Voltage, Frequency, Apparent energy, Apparent power, Active and reactive energy, Active and reactive power. 3) Measurement Accuracy of Current +/- 0.5 %, Voltage +/- 0.5 %, Power +/- 0.5 %, Frequency +/- 0.05 %, Power factor +/- 0.01. 4) Input Voltage of Measurement Voltage: 35 to 480 V AC, 45 to 65 Hz between phases, 35 to 277 V AC, 45 to 65 Hz between phase and neutral, 35 to 600 V AC, 45 to 65 Hz between phases, 35 to 347 V AC, 45 to 65 Hz between phase and neutral, 600 to 999000 V AC, 45 to 65 Hz with external VT. 5) Input Current is Measurement Current: 5 to 6000 mA. 6) Rated Supply Voltage is 40 to 300 V AC, 45 to 65 Hz 40 to 300 V DC. 7) Ingress Protection of IP51 front: conforming to IEC 60529, IP30 body: conforming to IEC 60529. 8) Communication Protocol of RS485 with Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V. 9) Operating Temperature are Ambient air temperature for operation: -10"60 °C, Ambient air temperature for storage: -20"70 °C. 10) Relative Humidity is 5 to 95 % at 50 °C, 11) Measurement categories are Category III 480 V, Category II 480"600V.12)5 year Comprehensive Onsite Warranty shall be provided.
DC Power Supply
OD67931/2025-2026:DC Power Supply with following specifications - 1) Nominal Input Voltage of 100 V AC ... 240 V AC. 2) Frequency is 50 Hz ... 60 Hz 3) Input Current of 1.5 A (240 V AC) 4) Mains failure hold-up time is >20 ms at 240 VAC. 5) Ripple is <50 mVpp 6) Nominal Output Voltage of 24 V DC. 7) Output Current of 10A. 8) Adjustment Accuracy is ±1% to ±0.5% of the output voltage. 9) Degree of protection is IP20 10)Operational Indications are Green LED (Power/Operating Status), Red LED (Fault/Alarm Status), Yellow/Amber LED (Status/Warning). 11) Type of mounting is DIN-rail mounting. 12) Ambient operating temperature is -25 °C ... 70 °C . 13) Wire connection to Cage clamp. 14) Type of mounting is SMPS , shielded metal case with provision of earth 15).5 year Comprehensive Onsite Warranty shall be provided.
Surge Protection Barrier
OD67943/2025-2026:Surge Protection Barrier with following specifications - Plastic Housing- 1) Channel is 1. 2) Voltage of Ui 30 V DC. 3) Rated Current of Ir 250 mA 4)Leakage current of < 5 µA at 24 V . 5) Nominal discharge current of (8/20) In 5 kA per line (10x). 6) Max. surge current (8/20) Imax with 20 kA. 7) Degreeof protection is IEC 60529:2013. 8) Ambient temperature rage of -30 ... 80 °C (-22 ... 176 °F). 9) Housing of Plastic type 10) Degree of protection is IP20. 11) Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001. 12) IEC Ex approval of IECEx certificate IECEx BAS 14.0010X 13)5 year Comprehensive Onsite Warranty shall be provided.
Surge Protection Barrier - Steel Housing
OD68005/2025-2026:Surge Protection Barrier with following specifications - Steel Housing- 1) Channel is 1. 2) Rated Voltage Ur " 48 V. 3) Rated Current Ir " 250 mA. 4) Leakage current : 5 ?A. 5) On-state Voltage " 85 V. 6) Total discharge current (8/20 ?s) Itotal 20 kA. 7) Max. surge current (8/20) Imax 20 kA. 8) Degree of protection IEC 60529:2001. 9) Ambient temperature -30 ... 60 °C (-22 ... 140 °F). 10) Housing Steel type. 11) Degree of protection IP67. 12) Mounting NPT1/2 thread 13) CSA approval- yes. 14)5 year Comprehensive Onsite Warranty shall be provided.
Signal Isolator
OD68018/2025-2026:Signal Isolator with following specifications - 1) Input Signal of 4"20 mA DC 2) Output Signal of 4"20 mA DC 3) Power Supply with 24 V DC ±10% , ripple "10% peak-to-peak) 4) Load Resistance with Input: 250 "Output: Maximum 550 " 5) Operating Temperature Range from -5°C to +55°C 6) Mounting of DIN rail mountable.7)5 year Comprehensive Onsite Warranty shall be provided.
Residual Chlorine Analyzer
OD68022/2025-2026:Residual Chlorine Analyzer with following specifications - 1) Measuring Range of 0?20mg/l, resolution 0.01mg/L. 2) Temperature Range of 0 to 60°C. 3) Temperature measurement Accuracy is ±0.2°C. 4) Communication Mode with RS485 (MODBUS-RTU) with DTU, wireless transmission. 5) Withstand voltage range of 0?3bar. 6) Signal Output with 4-20mA (adjustable/three-wire system). 7) Shell Material is PC + stainless steel. 8) Sensitive film number with H4010 Sensitive Chlorine Film. 9) Calibration Interval from 3 to 6 months. 10) Maintenance of Electrolyte replacement every 3?6 months; membrane replacement every 6?12 months. 11) Process Connection of G3/4. 12) Electrical Connection to Direct outlet with 5m cable. 13) Output load is Less than 750?. 14) Power supply of 24VDC?12VDC?5VDC. 15) Protection Class is IP68, 16)5 year Comprehensive Onsite Warranty shall be provided.
Gateway
OD68032/2025-2026: Gateway with following specifications - 1)Processor with Quad-core ARM Cortex-A53, 1.3 GHz or higher (for efficient processing). 2)Memory is 512 MB to 2 GB DDR3/DDR4 RAM. 3)Storage of 4 GB to 16 GB eMMC storage (expandable via microSD or SD card). 4)Frequency Bands with EU868, US915, AU915, AS923, and others (depending on regional regulations). 5)LoRaWAN Channel is Support 8 to 16 channels (Full-duplex or Half-duplex options). 6)LoRaWAN Classes is Class A, B, and C (supports various device types with different power consumption needs). 7)Ethernet Connectivity of 1 × 10/100/1000 Mbps Gigabit Ethernet port (wired network connection). 8)Wi-Fi Connectivity with IEEE 802.11 b/g/n (2.4 GHz) support (with WPA/WPA2 security). 9)Cellular Connectivity with 2G/3G/4G LTE support (Optional, for mobile network connectivity). 10)GNSS (GPS) Support of GPS module support (for precise location tracking and time synchronization). 11)Ingress Protection (IP Rating) with IP65 to IP67-rated (dust and waterproof protection for outdoor and rugged environments). 12)Operating Temperature in Range -40°C to +70°C (for rugged environments) or -20°C to +50°C (for indoor environments). 13)Power Supply of 12V DC, PoE (Power over Ethernet), or USB (depending on model). 14)Cloud Support with Integration with cloud platforms (e.g., MilesightIoT Cloud, Laird Cloud, Kerlink Cloud, or The Things Network). 15)VPN Support of OpenVPN, IPsec, PPTP, L2TP, WireGuard (for secure communication). 16)Device Management with Web-based, CLI (Command Line Interface), SMS, cloud platforms (for remote configuration and monitoring). 17)Listen Before Talk (LBT) is Yes (to avoid channel interference in certain regions). 18)Mounting Options are Wall, pole, or DIN rail (for flexible installation options). 19)Remote Management is Yes (via cloud platforms or proprietary software). 20)Security of Encryption support (AES-128, TLS, etc.), device authentication, and secure remote access. 21)Data Retention is Ability to store data during network outages and forward it once the connection is restored. 22)Routing Protocols Supported of MQTT, HTTP, HTTPS, TCP/IP, UDP, SNMP, Modbus, and other IoT protocols for network integration.23)5 year Comprehensive Onsite Warranty shall be provided.
Inverter and Battery
OD71897/2025-2026:battery backup for RTU panel and field instruments.5 year Comprehensive Onsite Warranty shall be provided.
Control Valves with electrical Actuators
OD71909/2025-2026:200mm Control valve with following CHARACTERISTIC : MODULATING TYPE WITH INTEGRAL STARTER UNIT POWER SUPPLY : 415V AC (±10%), 50Hz (±5%) INPUT SIGNAL : 4~20mA FEEDBACK SIGNAL : 4~20mA (±5%) INDICATOR : CONTINUOUS POSITION INDICATOR HOUSING & COVER : ALUMINIUM ENCLOSURE : WEATHER PROOFIP 67 AMBIENT TEMP :-10°C ~ 55°C TORQUE SWITCHES : 2 X SPDT LIMIT SWITCHES : 2 X SPDT STALL PROTECTION :LCD SCREEN WITH CONTINIOUS POSITION INDICATOR & OTHER DIAGNOSTIC DISPLAY MANUAL OVERRIDE : HAND WHEEL-5 year Comprehensive Onsite Warranty shall be provided.
OD71915/2025-2026:100mm Control valve with following CHARACTERISTIC : MODULATING TYPE WITH INTEGRAL STARTER UNIT POWER SUPPLY : 415V AC (±10%), 50Hz (±5%) INPUT SIGNAL : 4~20mA FEEDBACK SIGNAL : 4~20mA (±5%) INDICATOR : CONTINUOUS POSITION INDICATOR HOUSING & COVER : ALUMINIUM ENCLOSURE : WEATHER PROOFIP 67 AMBIENT TEMP :-10°C ~ 55°C TORQUE SWITCHES : 2 X SPDT LIMIT SWITCHES : 2 X SPDT STALL PROTECTION :LCD SCREEN WITH CONTINIOUS POSITION INDICATOR & OTHER DIAGNOSTIC DISPLAY MANUAL OVERRIDE : HAND WHEEL,-5 year Comprehensive Onsite Warranty shall be provided.
OD71923/2025-2026:50mm Control valve with following CHARACTERISTIC : MODULATING TYPE WITH INTEGRAL STARTER UNIT POWER SUPPLY : 415V AC (±10%), 50Hz (±5%) INPUT SIGNAL : 4~20mA FEEDBACK SIGNAL : 4~20mA (±5%) INDICATOR : CONTINUOUS POSITION INDICATOR HOUSING & COVER : ALUMINIUM ENCLOSURE : WEATHER PROOFIP 67 AMBIENT TEMP :-10°C ~ 55°C TORQUE SWITCHES : 2 X SPDT LIMIT SWITCHES : 2 X SPDT STALL PROTECTION :LCD SCREEN WITH CONTINIOUS POSITION INDICATOR & OTHER DIAGNOSTIC DISPLAY MANUAL OVERRIDE : HAND WHEEL-5 year Comprehensive Onsite Warranty shall be provided.
RTU Panel installation
OD71944/2025-2026:Supply, installation, and commissioning of Remote Terminal Unit (RTU) panel including appropriately rated ELCB, MCB,SPD isolation transformer, all required electrical components, and complete internal wiring.-5 year Comprehensive Onsite Warranty shall be provided.
Instruments earthing
OD73118/2025-2026:Instrumentation earthing shall be provided separately for each RTU using copper plate earthing as per IS 3043 and Drawing No. FCRI/KWA/2025/006. A 60 cm × 60 cm × 3 mm copper plate electrode shall be installed vertically at a minimum depth of 2 meters. The earth pit shall include a brick masonry enclosure (minimum 30 cm × 30 cm × 30 cm) with CI/MS cover, GI pipe, mesh funnel, and charcoal-salt layers. The earthing system must achieve a resistance of less than 3 ohms. Copper strip of 25 mm × 3 mm shall be used from Instrumentation Racks and Junction Boxes to the electrode
Installation of energy meter
OD71950/2025-2026:Energy meters shall be, installed, and commissioned for monitoring power consumption of RTUs and instruments within the SCADA system, with real-time measurement of electrical parameters. They will be mounted on pole-mounted industrial panels at field RTUs and at the Central SCADA Station for monitoring RTU1 and central equipment. Communication of energy data (kWh, V, A, Hz, PF) will be via RS485 or Ethernet to the SCADA/RTU module-5 year Comprehensive Onsite Warranty shall be provided.
Installation of pressure transmitter
OD71968/2025-2026:Gauge pressure transmitters shall be supplied, installed, and commissioned at each RTU location downstream of the flowmeter for local pressure monitoring and remote telemetry via SCADA RTUs. Transmitters with HART/RS485 or 4-20 mA output and suitable manifolds shall be mounted either inside meter pits (protected against flooding) or on poles, with stainless steel impulse tubing and proper head correction. Weatherproof (IP68) cable glandings shall be provided to prevent moisture or water ingress-5 year Comprehensive Onsite Warranty shall be provided.
Installation of flow meter
OD71975/2025-2026:Electromagnetic full bore flowmeters, suitable for drinking water applications, shall be supplied, installed, and commissioned at specified locations, considering site and media conditions. Flowmeters shall interface with the Control Room RTU via HART/RS485 or analog 4-20 mA signals, with wall/pole-mounted indicators rated IP68. Installation shall ensure required straight lengths (5?8D upstream, 3?5D downstream) and may include necessary pipeline modification work such as reducers or spools to meet installation criteria. Electromagnetic flowmeters are preferred due to their low pressure loss, absence of moving parts, minimal maintenance, and ability to be installed with limited pipeline alterations.-5 year Comprehensive Onsite Warranty shall be provided.
Control valves installation
OD71980/2025-2026:Control valves with electric actuators shall be supplied, installed, and commissioned at designated locations. Installation includes electrical wiring, termination, and integration with the SCADA/RTU system. Necessary pipeline modification such as cutting, welding, and reducer/spool installation shall be carried out to suit site conditions. All works shall ensure proper alignment, sealing, and operational readiness of the valve system.-5 year Comprehensive Onsite Warranty shall be provided.
Level sensor installation
OD71992/2025-2026:Level sensors shall be supplied, installed, and commissioned for monitoring liquid levels at specified locations. Installation includes mounting, electrical wiring, termination, and integration with the SCADA/RTU system. Necessary structural supports or brackets shall be provided based on site conditions. All works shall ensure accurate signal transmission, proper sealing, and reliable sensor operation-5 year Comprehensive Onsite Warranty shall be provided.
Water quality analyser installation
OD71997/2025-2026:Water Quality Monitoring System shall be supplied, installed, and commissioned near the SCADA Central Station or other specified locations, featuring modular sensors for parameters like turbidity, residual chlorine, pH, and dissolved oxygen. The system shall include sensor modules, manifolds, tubing, power supply, digital display, communication interfaces (RS485/MODBUS, HART, or Ethernet), and protective housing with transparent access for monitoring and control. Water will be continuously sampled through a flow-through setup and analyzed in a controlled environment for reliable and accurate data. Sensor data shall be displayed with date and time and integrated with the SCADA system through a controller module-5 year Comprehensive Onsite Warranty shall be provided.
SCADA Designing
OD72003/2025-2026:Design, installation, and commissioning of a comprehensive SCADA system shall be carried out for real-time monitoring, data acquisition, and control of flow, pressure, level, energy, and water-quality parameters from field RTUs. The SCADA shall feature secure data logging with FIFO memory management, 2-second data refresh rate, automatic time synchronization, and seamless integration with Central SCADA Station, ensuring uninterrupted data availability. The system will include modular software covering field instrumentation, automation, GIS-based asset mapping, and provision for integration with consumer meter data via BMS. SCADA software will support intuitive screen hierarchies, live dashboards, historical trend plotting, GIS maps, real-time alerts, and automated report generation. All modules will adhere to ISA/IEC 62443 cybersecurity standards, with secure access for authorized users via desktop or mobile devices.-5 year Comprehensive Onsite Warranty shall be provided.
Wiring (3-core 0.5 sqmm)
OD72008/2025-2026:Supply, laying, and termination of 3-core 0.5 sqmm shielded signal cable shall be carried out at required locations. Cables shall be suitable for instrumentation and signal transmission applications with proper shielding to minimize interference. The cable shall be laid through suitable conduits/trays with identification tags as per standard practices. Proper termination, testing, and continuity checks shall be ensured before commissioning.
Wiring (8-core 0.5 sqmm)
OD72011/2025-2026:Supply, laying, and termination of 8-core 0.5 sqmm shielded signal cable shall be carried out at required locations. Cables shall be suitable for instrumentation and signal transmission applications with proper shielding to minimize interference. The cable shall be laid through suitable conduits/trays with identification tags as per standard practices. Proper termination, testing, and continuity checks shall be ensured before commissioning.
Wiring (3-core 1.5 sqmm)
OD72015/2025-2026:Supply, laying, and termination of 3-core 1.5 sqmm Copper normal cable shall be carried out at required locations. Cables shall be suitable for power supply applications.The cable shall be laid through suitable conduits/trays with identification tags as per standard practices. Proper termination, testing, and continuity checks shall be ensured before commissioning.
Valve and Meter Chamber
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.
Control room desk-3 bay
OD84080/2025-2026:Control room desks equipped with built-in sliding drawers for 19-inch rack units, offered in 3-bay model
Control room desk - 4 bay
OD84082/2025-2026:Control room desks equipped with built-in sliding drawers for 19-inch rack units, offered in 4-bay models
Man power for 3 years - DLP period
OD84110/2025-2026:Supply of qualified manpower for operation and control as per the direction of Departmental Officers at the Central SCADA Station for 5 years
Calibration charges of equipments
OD84127/2025-2026: Factory Acceptance Tests/Test Certificates & Calibration Certificates from NABL accredited Labs,
DLP Period - 3 years including network charges
OD84135/2025-2026:DLP Period- To maintain the entire SCADA system under comprehensiv e onsite warranty for a period of five (5) Years from date of certified completion of NDOP. 5G/4G LTE / 3G /GSM-GPRS / communication equipment/routers, UPS, etc.
setelia llp (BID ID -2344804)
T ABDUSSAMAD (BID ID -2344832)
Bidder Name
T ABDUSSAMAD
setelia llp
Midland Contracting Private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1316270.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .