Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC 268 RABINDRA PALLY BLOCK D KOLKATA PIN 700086 | KOLKATA | KOLKATA | WEST BENGAL | 700086 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹26.9 L+₹2.4 L (9.87%)Rejected-Finance A 90 NEW RAIPUR ROAD A 90 NEW RAIPUR ROAD KOLKATA NEW RAIPUR ROAD NEAR GANGULY BAGAN SOUTH 24 PARGANAS WEST BENGAL 700084 | 24 PARAGANAS SOUTH | WEST BENGAL | 700084 | L2 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER. | |
| 3 | L3₹24.9 L+₹42,306.54 (1.73%)Rejected-Finance | L3 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
5 Nov 2024, 2:00 pmClosed
EE MDD-I
Office of the Executive Engineer, Metropolitan Drainage Division-I, Jalasampad Bhawan (4thFloor), South Block, Bidhannagar, Salt Lake City, Kolkata - 700091
Renovation of Meeting Room of State Project management Unit and its sound system at Ground Floor of Jalasampad Bhawan, Salt Lake City under DRIP-II
2024_IWD_762476_1
WBIW/EE/MDD-1/DRIP/RFB-01/ 2024-25
Open Tender
CIVIL WORKS
Item Rate
60 days
Jalasampad Bhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹50,000
Yes
O/o EE MDD-I
3 Jun 2025
8 Oct 2024
14 Nov 2024
8 Oct 2024
5 Nov 2024
8 Oct 2024
23 Oct 2024
Amount
Stripping off worn out plaster and raking out joints of walls, ceilings etc. upto any height and in any floor including removing rubbish within a lead of 75 m as directed.
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging thebase and removing rubbish as directed within a lead of 75 m a) In ground floor including roof.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
Removal of rubbish.earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Dismantling carefully wood work in posts, postplates, rafters, partition etc., sorting and stacking serviciable materials at site and removing rubbish as directed.
(B) Dressed wood work in post , plate , battens . etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals)(i) Sal : Siliguri.
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor (ii) 6mm
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-in-charge.The rate includes the cost of labour, adhesive and all incidental charges thereof In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. (ii) Thickness of laminate 1 mm
Ceiling with 12mm thick wooden planks fitted and fixed complete (excluding the supporting framework ) as per direction of the Engineer-in-charge. In Ground Floor (a) Ordinary Teak
Supplying, fitting and fixing of false ceiling framework with powder coated exposed G.I. grid suspension system (T-Grid having load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit all complete as per the drawing & directions of Engineer-in-charge.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(l:2:4) as per direction. (Cost of concrete will be paid separately) for all floors. 40mm X 6mm, 250mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (v) 100 x 63 x 3.2mm.
i) Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. ii) Godrej Hydraulic door closer fitted and fixed complete. a) Heavy type
Door stopper (Brass)
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges
(a)Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white (A) In 15 Micron thickness coloured Annodizing film
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick clear glass.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] Celling 10 mm thick plaster ii) With 4 : 1 cement mortar d) Gr. Floor
Providing and fixing of 15mm thick Mineral Fibre Acoustic Ceiling Tiles of approved pattern and size 595mm X 595mm should be placed in the Grid module to form a False Ceiling with NRC value ≥ 0.6 Material class: A2-s1, d0 as per EN 13501-1, Fire: REI – REI120 as per EN 13501- 2, Surface Burning Characteristics: Class 1 or A as per ASTM E 84) with powder coated exposed G.I. grid suspension system (interlocking T-Grid, having load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins/ soffit. All complete as per the drawing & directions of Engineer-in-charge. Acoustic False Ceiling (with 15mm thick OW AcousticBoard and E-Grid U-1520).
Unskilled labour
Providing and fixing in postition roller blind of approved make and brand as per drawing , design and direction of EIC Fabric description : Fibere-glass coated fabric ,0.03mm thick , 62 threads per sq in 0.750 Ibs per sq in . (441g per sq mt) Fabric width: as per site condition with up- stand along the length of the dry pocket , removable type for servicing shades Operation: Manuual Monuting : Pocket mounted .(pocket to be provided by other agency )shade Orientation: Regular roll, shade cloth falls at window side of roller Configuration:Single band Closure with up- stand along the length of the dry pocket , removable type for servicing shades.
Marvel High Back Chair Seat Size 47.0 cm (W) x 48.0 cm (D), Cushion back: PU Foam, High Back size: 47.7 cm (W) x 76.4 cm(D)
Beat Leatheratt e visitor Chair Mid back size: 51.6 cm (W) x 65.7 cm(H) Seat size: 49.0 cm (W) x 48.8 cm (D)
Full Desktop Chair 7004XD Mid back size: 49.0 cm (W) x 47.0 cm(H) Seat size: 49.0 cm (W) x 44.0 cm (D)
Premium Lounge 3 Seater Chair Seat size: 52.0 cm(W) x 50.0 cm(D) x 6.0cm(T)
Supplying & installing in posisition Reception table of approvedmake and brand as per drawing (Drawing Sheet-7), design and direction of EIC Providing Table 19 mm.thick top on BWR Ply of IS 303 Code alongwith 0.07mm. Post Forming laminatte ontop and back.All the four side have Post formed finished only the corner will have chamfered.All the legs as IS 304 grad stainless with minimum of 40 mm. dia of 1.2 thick All completed.
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works i) 12 Module
ii) 6 Module
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying of approved make wall fan oscillating type with base, blades, guard, speed regulator etc. AC 230- 250 volts. 400mm sweep (USOR P: 128, Item : 5.3 G.4.2)
Supplying of approved make Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts. 450 mm sweep (USOR P: 128, Item : 5.3 G.2.2)
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) (PWD P : E-11, Item -D-1(c))
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) [for horizontal run & ceiling portion] and partly in 19mm bore, 3mm thick polythene concealed pipe [for vertical run embedded in wall only], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment flushed in wall incl. mending good damages to original finish [PVC casing-capping on Wall and vertical & switch box both concealed] i) Average run 8 mtr
ii) Average run 10 mtr
Supply and fixing of philips Soft Glow Office compliant fully diffused recessed mounted 2'X2' false ceiling based LED light including connection by 1.5 sq mm cu wire. Make : Philips 36 Watt
Supply and fixing of GreenLED Ultima Square (6" x 6") , incl cutting the false ceiling in reqd dimensions also the wiring and connection of the light by 1.5 sq mm cu wire complete. Make : Philips, 10 watt square/ round
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Siemens, 2+8 way Enclosure (8GB32102RC10)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. Siemens, 40A
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & characteristics on din rail of existing DBs and necessary connection i) 6-32A, SP Siemens
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. i) On Board
Supply & installation of LED Profile Aluminium 16 mm x 6 mm (For LED Strip Lights) concealed in wood partition wall and mending good the damages complete in all respect. (7ft x 4 nos x 6 locations)= 168 ft (170 ft) = 52 Mts
Supply and fixing of SkyCove LED Strip Light (5M length) with driver and necessary connection. i) Make : Philips , LED Strip SKYCove 5M WW with driver
SITC of Bosch make Gooseneck Microphone Model No : LLB-1950, Voltage range : 12-48 V, Output Impedence - 200 ohm, 5-pin DIN 180 deg (lockable) connector, Connectivity - wired.
SITC of Bosch PA LBD3903-D 12W Black Colour Cabinet loudspeaker, Model : LBD3903D.
Solderable Mic cable roll for making microphone cable, XLR cable without any jack pure copper solderable Mic cable 64 strand breeding 2 core.
XLR Male Female & P38 Jack Make : MX or equivalent
Supplying of Get More PhotosView Similar EV R300 Handheld System W/PL22 Dynamic Microphone, Model Name/Number: R300-HD
SITC of Bosch make PA Plena PLE - 1ME120 - 3IN 120 W Mixer amplifier with USB/ Bluetooth, 4 microphone/ line inputs, plus music source input.
Full HD Projector, display technology DLP, resolution 1080p (1920x1080), 50000 : 1 contrast ratio, 3600-400 lumens of brightness, lightning-fast response time of 16 ms with a 120 Hz refresh rate, true 3D content from any 3D source, connectivity : USB, HDMI, 3.5 mmAudio, Aspect ratio 16 : 9
Supply LED Tv by 139 cm (55 inches) 4k Ultra HD smart LED Google TV with alexa compatibility. Resolution 4K Ultra HD (3840 x 2160) refresh rate 60 Hz 178 Degree wide veiwing angle connectivity 3 HDMI Ports to connect set top box, Blue ray pairs, gaming console, 2 USB potes to connect hard drive and other USB devices. Sound: 20 watts output open buffle speaker, dolby audio, clear phase. Smart Tv features: Google Tv, watch list voice serch, Google play, crom cast netflix, amazon prime vidio. additional features: apple air play, apple home kit, alexa. Display: X1 4k processor, 4k HDR, live color, 4k X reality Pro, motion flow XR 200
SEN AND ASSOCIATES (BID ID -5740499)
RAJAN INFRATEC PVT. LTD (BID ID -5740487)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .