Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | ₹15.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹17.2 L+₹1.9 L (12.1%)Rejected-Finance | ₹17.2 L+₹1.9 L (12.1%) | L2 | Rejected-Finance L2-REJECTED |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
3 May 2021, 11:00 amClosed
Regional manager
The Regional Manager, 4th Floor, ISAACS Tower, Jawahar Nagar, Kadavanthra, Kochi, Kerala-682020
HVAC at District Drug Warehouse Manjeri
2021_WAPCO_417543_1
WAP/INFRA/KERALA/HVAC/2021/322
Open Tender
Miscellaneous Works
Item Rate
30 days
Manjeri
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,800
₹25,000
8 Aug 2024
20 Feb 2021
4 May 2021
20 Feb 2021
3 May 2021
20 Feb 2021
Amount
HIGH SIDE PART -A
od209235/2020_2021 : Supply of ceiling suspended air cooled ductable split air-conditioners each complete with BLDC Motors for indoor unit, Inverter scroll compressor, air cooled condenser with black fin coating and epoxy coating all the coatings to be covered under manufacture warranty, GSS casing, filters, cooling coils, R410 A refrigernet DC fan motors, corded remote with fan speed and ESP setting Electronic expansion valve refrigerant controls and accessories complete for following unit. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%,3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5<br><br>11 TR, 4400 CFM HIGH STATIC INVERTER DUCTABLE SPLIT UNIT
LOW SIDE - PART B
od209236/2020_2021 : Installation, testing, and commissioning of 11 TR High static Ductable Air conditioner
od209238/2020_2021 : Supply, installation and testing of uPVC sch.40 condensate drain piping with thermal insulation of 9mm thick class O anti-microbial nitrile rubber
od209239/2020_2021 : Electrical control cabling<br>Control wiring between indoor and outdoor units with copper/ aluminium cabling.
od209240/2020_2021 : <br>Supply of MS support stand for 11 TR Outdoor units with proper clamping
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od333516/2020_2021 : Supply installation testing and commissioning of Fresh Air louvers with bird screen with VCD.
od209241/2020_2021 : Supply of Support stand for indoor units & duct of MS with proper clamping
od209242/2020_2021 : Supply, installation, testing and commissioning of GSS rectangular duct as per drawings. complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter, dampers, indoors, transformation pieces etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs.(only hitech supports shall be used). Thickness - 24 Gauge
od209243/2020_2021 : GSS DuctingCanvas Connection
od209244/2020_2021 : Supply , installation, testing & commissioning of 9mm thick duly laminated aluminium foil of mat finish closed cell anti-microbial Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Density of insulation material shall be between 40 to 55 Kg/m3 and and thermal conductivity shall not exceed 0.035 w/(m.K. )
od209245/2020_2021 : Supply , installation, testing & commissioning of 10mm thick, Class 1 rated open cell anti-microbial Nitrile rubber for acoustic insulation of ducts using suitable adhesive as per the recommendation of the insulation manufacturer. Density of insulation material shall be between 140 to 180 Kg/m3 and and thermal conductivity shall not exceed 0.047 w/(m.K.)
od209246/2020_2021 : Additional Refrigerant gas R410A
PARTITION WORKS
od210050/2020_2021 : Double Skin Aluminium Panel Partition :<br>Providing and fixing in position factory made sandwich panels made of light weight insulated sandwiched panel of 0.5 mm thickness for aluminium sheets. Injected polyurethene foam of 50mm thickness and 40 kg/m3 density to be sandwiched between composite panels with necessary supports, accessories required to support the panels rigidly
Anukool India Private Limited
Bidder Name
Anukool India Private Limited
BST AIR CONDITIONING & REFRIGERATION PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .