Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 435 4TH FLOOR KALIANDAS UDYOG BHAVAN SADANAND HASU TANDEL MARG PRABHADEVI MUMBAI MAHARASHTRA 400025 | MUMBAI | MAHARASHTRA | 400025 | Admitted-Finance |
| 2 | Admitted-Finance 3 256 PUJARI NIVAS 3RD BLOCK KATIPALLA DAKSHINA KANNADA KARNATAKA 575030 | DAKSHINA KANNADA | KARNATAKA | 575030 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Jan 2023, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM CC AND PHS
ROOM NO.37 ADMIN BUILDING RCF
Value based Biennial Rate contract for On-line Leak Sealing Jobs on High Pressure pipings at RCF Trombay Unit.
2022_RCFL_731720_1
ET-CC/MES/602/L/2223/019
Open Tender
Miscellaneous Services
Lump-sum
730 days
RCF TROMBAY
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹30,000
Yes
14 Feb 2023
28 Dec 2022
18 Jan 2023
28 Dec 2022
18 Jan 2023
28 Dec 2022
Amount
TEAM RATES.
1.1-Team Day Rates Rs. Per Team Per Day of 10 hours from the time at reaching RCF site job location ( For working on any day including Sundays & holidays ) – including clamp fitting
1.2-REINJECTION RATES: 181 to 270 days, Rs. Per Team Per Day (10 hours from the time at reaching RCF site job location - For working on any day including Sundays & holidays )
1.3-OVERTIME RATES. Rs. Per hour Per Team for working beyond 10 hours at stretch from the time at reaching RCF site job location
1.4-Rate per kg for sealing compound (applicable only when job done on team day basis)
2.1-ITEM RATES FOR FLANGE JOINT LEAK / VALVE BONNET LEAK / ORIFICE FLANGE JOINT LEAK.
2.1.A-FLANGE GAP UP TO 20MM
2.1.A.1-FLANGE GAP UP TO 20 mm. ( Flange Pressure Rating up to & including 150 # )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.1.A.2-Flange Gap up to 20mm(Flange Pressure Rating from & above 300# up to & including 600# )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.1.A.3-Flange Gap up to 20mm (Flange Pressure Rating above 600# up to & including 1500# )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.1.B-FLANGE GAP ABOVE 20MM up to 40MM.
2.1.B.1-Flange Gap above 20mm to 40 mm(Flange Pressure Rating from & up to & including 150 # )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.1.B.2-Flange Gap Above20mm up to 40mm(Flange Pressure Rating from & above 300# up to & including 600# )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.1.B.3-Flange Gap Above 20mm up to 40mm( Flange Pr. Rating above 600 # up to & including 1500 # )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.2-REINJECTION RATES FOR FLANGE JOINT LEAK / VALVE BONNET LEAK / ORIFICE FLANGE JOINT LEAK. (applicable from 181st to 270 days)
2.2.A-FLANGE GAP UP TO 20MM
2.2.A.1-FLANGE GAP UP TO 20 mm. ( Flange Pressure Rating up to & including 150 # )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.2.A.2-Flange Gap up to 20mm(Flange Pressure Rating from & above 300# up to & including 600# )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.2.A.3-Flange Gap up to 20mm (Flange Pressure Rating above 600# up to & including 1500# )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.2.B-FLANGE GAP ABOVE 20MM up to 40MM.
2.2.B.1-Flange Gap above 20mm to 40 mm(Flange Pressure Rating from & up to & including 150 # )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.2.B.2-Flange Gap Above20mm up to 40mm(Flange Pressure Rating from & above 300# up to & including 600# )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
2.2.B.3-Flange Gap Above 20mm up to 40mm( Flange Pr. Rating above 600 # up to & including 1500 # )
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
3-ITEM RATES FOR CAULKING OF PIPE LINES / VALVE BONNETS ETC. (All rates are in Rs.)
3A-Pressure Rating - up to & including 150 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
3B-Pressure Rating - from & above 300 # up to & including 600 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
3C-Pressure Rating - above 600 # up to & including 1500 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
4.1-ITEM RATES FOR INJECTION IN BOX CLAMPS in -Rs. for minimum length of 4” of the Box clamp. Above 4” length of box clamp the injection rate will be calculated on pro-rata basis
4.1.A-Pressure Rating - up to & including 150 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
4.1.B-Pressure Rating - from & above 300 # up to & including 600 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
4.1.C-Pressure Rating - above 600 # up to & including 1500 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
4.2-ITEM RATES FOR RE-INJECTION IN BOX CLAMPS in -Rs. for minimum length of 4” of the Box clamp. Above 4” length of box clamp the re-injection rate will be calculated on pro-rata basis (applicable from 181st to 270 days)
4.2.A-Pressure Rating - up to & including 150 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
4.2.B-Pressure Rating - from & above 300 # up to & including 600 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
4.2.C-Pressure Rating - above 600 # up to & including 1500 #.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5.1-Item rate for Injection sealing for valve gland leaks
5.1.A-Pressure Rating up to & including 600#
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
5.1.B-Pressure Rating - Above 600 # up to & including 1500#.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
5.1.C-Pressure Rating - Above 1500 # up to & including 2500#.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
5.2-Item rate for Re-Injection for valve gland leaks (applicable from 181st to 270 days)
5.2.A-Pressure Rating up to & including 600#
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
5.2.B-Pressure Rating - Above 600 # up to & including 1500#.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
5.2.C-Pressure Rating - Above 1500 # up to & including 2500#.
1-Nominal Pipe Size 1/2" thru' 2''
2-Nominal Pipe size - 3" thru' 6''
3-Nominal Pipe size - 8" thru' 12"
4-Nominal Pipe size - 14" thru' 18"
5-Nominal Pipe size - 20'' thru' 24''
6-RING CLAMP RATES: For gap up to 20mm between flanges (more than 20mm on pro-rata basis)
6A-C S Clamps
6A.1Flange pr. rating up to & including 150#
6A.2-Flange pr. rating (from & above 300# up to & including 600#)
6B-S.S Clamp
6B.1-Flange pr. rating up to & including 150#
6B.2-Flange pr. rating (from & above 300# up to & including 600#)
7-Box clamp rates- Rate per inch width of the clamp
7A.1-Flange pr. rating- up to & including 150#
7A.2-Flange pr. rating- from & above 300# up to & including 600#
7B.1-Flange pr. rating- up to & including 150#
7B.2-Flange pr. rating- from & above 300# up to & including 600#
PNEUMECH ENSAVE PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .