Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC TC 50 956 I VASATHY TRWA 395 THALIYAL KARAMANA PO THIRUVANANTHAPURAM KERALA 695 002 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695002 | L1 | Accepted-AOC Admitted Found Reasonable for Acceptance | |
| 2 | L2₹12.2 L+₹89,849.40 (7.94%)Rejected-Finance MAYOORASASI COMPLEX TC 6 2034 2 SHOP NO 09 THURUVIKAL PO AKULAM TRIVANDRUM 695011 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695011 | L2 | Rejected-Finance Rejected L1 being accepted | |
| 3 | L3₹12.5 L+₹1.2 L (10.6%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L3 | Rejected-Finance Rejected L1 being accepted | |
| 4 | L4₹13.7 L+₹2.4 L (20.9%)Rejected-Finance | L4 | Rejected-Finance Rejected L1 being accepted |
Tender Value
₹13.6 L
EMD Value
₹27,300
Closing Date
14 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2022_MES_504908_2
GE (ARMY) TVM 9431/E8
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹27,300
Yes
4 Apr 2022
19 Feb 2022
22 Mar 2022
19 Feb 2022
14 Mar 2022
28 Feb 2022
60 days
Amount
Roughening of surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry 3 kg of cement per sq metre.
M&L for rendering in CM 1:3, 10 mm thick on concrete or brick surfaces, mixed water proofing compound @ 3% by weight of cement, finished even and smooth without using extra cement. Note : Water proofing compound will be measured and paid seperately.
M&L for APP modified water proofing membrane weighing not less than 3.0 Kg/ Sqm reinforcement weighing not less than 100 gms / sqm having softening point not less than 140 degree celsius, longitutudinal tensile stength not less than 300 N / Sqcm, tearing strength of 100 Nm by torch application including minium 10 cm side lap and 15 cm end laps over acoat of Bituminous emelson @ 100gms / Sqm on planted surface and hot blown bitumen 85 /25 grade @ 1.20 kg / Sqm and finishing with solar refelective Bituminous aluminum paint applied 100 gms /sqm including dismantling and removal of exisiting unserviceable membrane all as specified and directed.
Demolition of brick work or concrete block/stone/boulder masonry built in cement mortar including rubbish off the premises, etc complete all as specified and directed.
M&L for Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down cement plaster of any description of brick or concrete including racking out hacking for key, joints scrubbing down with water etc all as specified and directed.
M & L for Rendering 5 mm thick on fair faces of brick work or concrete surfaces with cement mortor (1:4) mixed with water proofing compound @ 3% by the weight of cement over 10mm thick with cement mortor (1:6) in external surfaces of wall (upto four storey building) all as specified and directed. Note:Water proofing compound will be measured and paid separetly.
M & L for rendering 10 mm thick in ceiling/facia with cement mortor (1:3), finished even and smooth without using extra cement all as specified and directed.
Supply only integral water proofing compound
M & L for applying two coats of acrylic exterior emulsion water proofing painting over one coats of primer including preparing of new plastered surfaces on external walls as per manufacturer's instructions etc complete all as specified and directed.
M & L for preparing new plastered surfaces and applying three coats of white wash on ceiling, etc complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:6 on fair faces of concrete surfaces finished fair and smooth in patches without using extra cement, etc complete all as specified and directed.
M&L for two coats of oil bound distember over a coat of primer including prepartion of new plastered surfaces of wall etc complete all as specified and directed.
Dismantling of wall and ceiling boards or insulation boards any thickness including cover fillets etc complete.
S&F Non Asbestos decorative type fibre cement building boards , 4 mm thick fixed or laid / inserted to timber / GI / Aluminum frame work with screws on ceiling, etc complete all as specified and directed.
M&L for Anodised aluminum snap grid frame work for false ceiling, size of panel 605 x 605 mm etc complete all as specified and directed.
S&F Plain mild steel wire 2.5 mm dia galvanised class 3 in detached work such as for hanging ceiling and fixing to straining bolts, hook, eye, etc complete all as specified and directed.
Dismantling of single layer Mangalore pattern or similar tiles in roofing including ridge tiles.
M&L for Roof tiles , mangalore pattren, interlocking at side joints, laid dry (upto four storey building) etc complete all as specified and directed.
All as per item No 19.00 here-in-before, but except tiles.
M&L for Ridge or hip tiles to suit mangalore pattern roofing tiles, bedded and jointed in CM mortar 1:6, etc complete all as specified and directed.
Demolition of cement concrete (un reinforced) in roofs, floor ( other than ground floors) beams, staircase , landings , chajjas and similar suspended work.
M&L for Providing cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed.
Dismantling fillets for tiles battens, rafters, purlins etc under 40 sq.cm in section (unframed work) all as specified and directed.
M&L for 2nd class hard wood clean sawn plain fillets square, rectangular or triangular in section, secured with nails or brads, sectional area exc 13 sqcm but n exc 25 sqcm complete all as specified and directed.
All as per item No 25.00 here-in-before, but except fillets.
Dismantling timber scantling 40 sq cm and over in section unframed work, in any position, etc complete all as specified and directed.
M&L for 2nd class Hard Wood scantling, clean sawn, fixed in position, etc complete all as specified and directed.
All as per item No 28.00 here-in before, but except scantlings.
Dismantling of plain steel/aluminium sheeting of any gauge, thickness including Nainital or similar pattern roof covering.
S&F plain, aluminium sheeting, alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and grith as fixed) 0.56 mm thick
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws and J hooks etc complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof ridge, wall clading etc , fixed with self tapping screws and J hooks etc complete all as specified and directed.
S & F in repairs PVC (SWR) pipes 160 mm dia single socketed in any length with rubber ring joints fixed to walls (Upto four storey building) and making good plaster/brick work/RCC surfaces surrounding the PVC drain water pipe and applying exterior wall paint to match the existing surfaces etc complete all as specified and directed.
S & F in repairs PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls (Upto four storey building) and making good plaster/brick work/RCC surfaces surrounding the PVC drain water pipe and applying exterior wall paint to match the existing surfaces etc complete all as specified and directed.
S & F in repairs PVC (SWR) bends in any radius, 110 mm dia etc complete all as specified and directed.
S & F in repairs PVC (SWR) bends in any radius, 160 mm dia etc complete all as specified and directed.
S&F in repair 15mm bore UPVC tubing pressure rating 10kgf/cm² fixed complete to walls, ceiling or in floors etc any type of pipe inlcuding taking down existing etc (Upto four storey building) etc complete all as specified and directed.
All as per Item No.38.00 here-in-before, but 20 mm bore UPVC tubing.
All as per Item No.38.00 here-in-before, but 25 mm bore UPVC tubing.
Cutting/clearing small trees, saplings,shrubs and under growth complete roots from brick walls,chajjas etc including taking out complete roots from inside walls/chajjas and making good surfaces in cement concrete 1:2:4 type B1 or in cement mortar (1:4) including finishes to match the existing surfaces etc complete all as specified and directed (Upto four storey building).
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
Demolition of cement concrete (un-reinforced) as in ground floors or paving n. exc 15cm thick below or above ground level complete.
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) finished even and smooth without using extra cement as in plinth/hard standing etc complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes all as specified and as directed.
M&L for rendering in cement mortar 1:4, 10 mm thick as skirting / dado etc complete all as specified and directed.
M&L for Vitrified ceramic coloured tiles 10mm thick (square/Rectangular ) area of each tiles exceeding 0.18 Sqm but not exceedng 0.38 sqm, as in floors etc, set and jointed neat cement slurry and pointed with colour cement to match etc complete all as specified and directed.
All as per item No 48 here-in-before but as in skirtings.
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/Rectangular ) area of each tiles exceeding 0.11 Sqm but not exceedng 0.18 sqm, as in floors etc, set and jointed neat cement slurry and pointed with colour cement to match etc complete all as specified and directed.
M&L for glazed ceremic coloured tiles of size 450x300x7mm thick as in skirting/dados set and jointed in neat cement slurry and pointed with coloured cement to match etc complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each, complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ' C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rails and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joinned together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed.
S & F Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
S & F Aluminium anodised, Butt hinges, 100mm long complete all as specified and directed.
S & F Aluminium handles, cast type, anodised of size 125 mm long, complete all as specified and directed.
S & F Aluminium, anodised, barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty etc, complete all as specified and directed
S & F 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane, complete all as specified and directed.
S & F in repairs Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S & F in repairs PVC coated mild steel conduit pipe 25mm bore (Drapery rod) with a pair of PVC coated MS clamps to hold drapary rod and decorative attachment at both ends of drapary rod, fixed to opening of door/windows,(Each opening n.exc 1.50mtr, contained with a pair of clamps and a pair of side ornamental attachments) complete all as specified and directed.
Excavating in trenches, n exc 1.5 M wide and n exc 1.5 M in depth, for foundation, etc or for shafts, wells, cess pits, manholes, pies holes, etc n exc 10 sqm on plan and n exc 1.5 M in depth and getting out in hard / dense soil complete all as specified and directed. NOTE:- The rate quoted shall be deemed to be included necessary charge for Bailing out mud water that if found accumulated in open storm water drain/chamber and disposing to a distance exc 100 mtr but n. exc 500mtr.
M&L for PCC 1:4:8 Type D2 (Using 40mm graded agg) as foundation, mass concrete etc complete all as specified and directed.
M&L for Pre-Cast Cement Concrete block masonry with PCC type C1, 1:3:6 (using 20mm graded aggregate) solid blocks exc 10 cm in width and setting in CM 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping, including necessary form work, etc complete all as specified and directed.
M&L for Rendering in CM 1:4, 10mm thick on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement.
M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in surface channels and drains etc.complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Returning filling including spreading levelling watering and well ramming in layers n.exc 25cm in soil all as specified and directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
Demolition of Reinforced cement concrete of any description in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition).
M&L for providing precast reinforced cement concrete 1:2:4, type B1 (20mm gaded aggregates) slabs /shelves/landing and similar articles with plain faces and set in CM 1:4 all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia as reinforcement bars, cut to length, bent to shape required, inlcuding cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars10mm dia and over as reinforcement bars, cut to length, bent to shape required, inlcuding cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S & F PVC pipe 110mm dia, single socketed, fixed in walls for weep holes.
AKASH CONSTRUCTIONS
DJ GROUP
SHILPA ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .