Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC VALID AND ADMITTED | |
| 2 | L2₹12.5 L+₹1.0 L (9.00%)Rejected-AOC | L2 | Rejected-AOC VALID AND ADMITTED |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
20 Jul 2020, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2020_MES_354999_1
8520
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹29,000
Yes
22 Aug 2020
23 Jun 2020
22 Jul 2020
23 Jun 2020
20 Jul 2020
3 Jul 2020
27 Jun 2020 - 30 Jun 2020
Amount
Excavation in trenches nexc 1.5 mtr in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil.
Excavation in trenches exc 1.5 mtr in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and exc 1.5 mtr but n.exc. 3.0 mtr depth and getting out in soft/loose soil.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified.
M&L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise all as directed.
Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site :-
185 Sqmm 3.5 core
120 Sqmm 3.5 core
95 Sqmm 3.5 core
70 sqmm 3.5 core
50 sq mm 3.5 core
25 sq mm 3.5 core
16 sq mm 4 core
10 sq mm 2 core
Supply and Laying only including jointing and testing only electric under ground LT cable PVC/XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches ducts, pipe on walls, poles of following sizes
185 Sqmm 3.5 core
120 Sqmm 3.5 core
95 Sqmm 3.5 core
70 sqmm 3.5 core
50 sq mm 3.5 core
25 sq mm 3.5 core
16 sq mm 4 core
10 sq mm 2 core
M&L for GI steel tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes :-
80 mm dia bore
50 mm dia bore
M&L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.0 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR 2009 indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, cast iron cover with lifting handle, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete.
M&L for straight through joint outdoor type for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables. (Make : Denson, M-Seal or equivalent)
50 to 70 sqmm 3.5 core
95 to 120 sqmm 3.5 core
120 to 185 Sqmm 3.5 Core
M&L for preparation of existing old painted surface of any description such as Panels any height and painted by spraying with one coats of primer (superior quality) and a coat of synthetic enamel paint in blue color all around the panels. Make of Paint : Asian (Apcolite), Berger (Brolac) or equivalent.
Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 70 to 185 Sqmm.
Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all the three phases, checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that load is nearly balanced in all the three phase complete all as specified and directed.
Dismantling of cross - arms , MS channel or any type of angles with clamps, nut, bolts etc complete all as specified & directed.
M&L for cross arms, bracing supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot , drilling holes for bolts in any shape or size as indicated and including two coat of aluminium paint over one coat of red oxide primer complete all as specified
Comprehensive maintenance of street light fitting comprising of 70W /125W /150W /250W/400W HPSV/HPMV/ lamp fittings of any make any model fitted on the pole at any height with any type of fixing arrangement by replacing the ignitor, ballasts, capacitor, flexible wire/Al wire two core 2.5 sqmm / 4sqmm, clamps, nuts and bolts and lugs for a period of 11 months all as specified & directed. (Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the pole and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing it to the proper height and removing all the hanging wires, cables, PVC pipes, old rusted clamps, hanging aluminium wires, hanging grasses etc and tightening of all nuts, bolts, clamps and fixing of the street light at proper direction all as directed.) Note : In replacement of Parts shall be measured & paid separately)
All as per item serial No.17 but for street light fittings of 1x40w tube light fitting and complete. Note : (Applicable for ser No. 1, 28 & 29) (a) Payment shall be make at proportionate rates as arrived from quoted rates. (b) In case any light found unserviceable for more than one week for the reasons attributed to the contractor, the panel recovery at the rate of double the quoted rate per week or part there of shall be done through RAR. (c) The comprehensive maintenance period shall be reckoned from the date of commencement to date of completion or a period of nine months from commencement of whole work which ever is later. (d) Decision of the accepting officer shall be binding upon the contractor regarding panel recoveries.
S&F in replacement steel tubular swaged complete cast iron plate base plate, finial plug, bolts, nuts and screws as specified type 410 SP-31 of length 9 mtr including earth work, PCC for foundation, copping all around the pole duly painted with aluminium paint over a red oxide primer as per SSR specification and directed. Note: Excavation & earth work shall be measured & paid separately.
S&F in replacement lamp suitable for luminers single end tubular type of following watts, Make Bajaj, Crompton, Havells, Phillips
Metal Hallide 400 watt
HPSV/HPMV 250 watt
HPSV/HPMV 150 watt
HPSV/HPMV 70 watt
S&F in replacment open construction heavy duty VPIT copper ballast for metal hallide luminous and HPSV/HPMV fitting Make Havells/CG for following :-
HPSV 400 Watt Make Phillips/wipro/CG.
HPSV 250 Watt Make Phillips/wipro/CG.
HPSV 150 Watt Make Phillips/wipro/CG.
HPSV 70 Watt Make Phillips/wipro/CG.
S&F in repair Electronic ballast suitable for fluorescent tube light fitting 4 X 40 Watts. Make Phillips/wipro/CG.
S&F in replacement electronic ignitor suitable for suitable for 250/400 W HPSV/MH lamp fitting. CAT No. BJIGN SV/MH SI of Make Bajaj or its equivalent in Phillips/Havells/CG.
HPSV 400/250 Watt
HPSV 150/125/70 Watt
S&F in replacement lamp holders porcelain threaded type suitable for HPSV fitting of following capacity :-
HPSV 250 Watt
HPSV 150 Watt
HPSV 70 Watt
Dismantling/taking out old defective cable form street light poles (Junction box to fitting/overhead line to fitting) and S&F aluminium conductor multistranded/solid on poles or passing through steel or PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete as per specification as required of following sizes :-
4 Sqmm two core conductor.
6 Sqmm two core conductor
S&F in replacement bracket with clamp for fixing street light fitting made out of GI pipe light grade including bending to shape of length 1.5 m complete :-
25 mm dia
40 mm dia
S&F in repair post top lantern fitting comprising with LED lamp of CAT Part No. LPTO-40-CDL/M, 40 watt of Make: CG or its equivalent in PHILIPS/WIPRO/CROMPTON/HALONIX LTD.
M&L in replacement for MCCB 4 pole 100 Amps, 415 volts, 25 KA and all as specified (Make Havells, L & T)
M&Lin replacement for MCCB TPN 63 Amps, 415 volts, 16 KA and all as specified (Make Havells, L&T)
Supply, fixing, testing and commissioning of LED street light in repairs with following specification as per LSTP-72 CDL 72 WATT OF MAKE CG or its equivalent in PHILIPS/WIPRO/CROMPTON/HALONIX LTD.
S&F in repairs wall security light LED type complete with GI bend 1.2 mtr and fixing on wall/pole with clamp, nut & bolt complete all as directed and specified by Engr-In-Charge. CAT Part No.LSTO-25-CDL 25watt of Make CG or its equivalent in PHILIPS/WIPRO/CROMPTON/HALONIX LTD.
Dismantling of analog timer and S&F Pole mountable (Timer switch for street lights) sensor based, astronomical and nature type timer switch with Nature switch - 02 Nos, power contactor for load switching, MCB, and terminal block, including complete with mounting brackets, cable glands, openable door with lock and key. The enclusure made of UV stabliszed, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor. Make : L&T/ABB
M&L for preparation of existing old painted surface of any description such as LT/HT steel tubular electric pole/struts of any height and painted including cross arms bracing clamps etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT/HT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint complete as directed.
Trimming of tree branches around 3 meter from over head conductor with necessary tools and ladders complete all as directed.
Taking down old unserviceable flood light fitting and M&L LED flood light fitting 150 watt . CAT No. LFLN of Make CG or its equivalent in Phillips/Havells/.
M&L for in replacement of Capacitor for street light fitting of 125/150/250/400 watt of Make Bajaj or its equivalent in CG/Wipro/
M&L for in replacement & stretching and binding aluminium conductor steel reinforced (ACSR) any type and any size with binding wire of suitable size and connecting the jumper on LT electric pole complete.
Dismantling loose/damaged LT ACSR conductors of any size including opening the wire from insulators mounted on electric pole and restringing/retightening & refixing/binding the conductor on insulator including jointing and jumpering on pole using suitable size of binding wire complete.
S&F in repairs MCCB 4 pole 160 Amps, 25 KA thermal magnetic Model No DPX250 of Make Legrand or equivalent make of Schnieder/ABB.
S&F in repairs MCCB 4 pole 250 Amps, 36 KA thermal magnetic Model No DPX250 of Make Legrand or equivalent make of Schnieder/ABB.
S&F in repairs Resin filled capacitor heavy duty 7.5 KVAr of Make Legrand Alpican or equivalent.
S&F in repairs Resin filled capacitor heavy duty 10 KVAr of Make Legrand Alpican or equivalent.
S&F in repairs Resin filled capacitor heavy duty 15 KVAr of Make Legrand Alpican or equivalent.
S&F in repairs LED driver for LED street Light fitting 70 W Make Sakthi or equivalent.
S&F in repairs LED driver for LED street Light fitting 150 W Make Sakthi or equivalent.
M&L for in replacement of cable jointing kit 50 to 95 sqmm for 11 kV grade (Earthed) HV cable for indoor termination heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed. Make: Birla 3M, Raychem.
M&L for in replacement of cable jointing kit 50 to 95 sqmm for 11 kV grade (Earthed) HV cable for outdoor termination heat shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed by EIC. Make: Birla 3M, Raychem.
M&L for in replacement, installing commissioning and testing of vertical switch air break gang operated HV 11 KV triple pole out door type and rated capacity 200 Amp with 9 insulator and steel frames mechanically operated mechanism consisting of three male contacts & three female contacts of tinned copper, three arching horns, three MS jumper carrier equipped with braided copper belt , operating rod of light grade 25mm bore GI pipe of suitable length worked from ground level with locking arrangement with clamp of flat iron 50X6 mm complete and testing on load. Make :PACTIL/BHEL/ATLAS.
M&L for replacement, installing commissioning and testing of vertical expulsion type drop out fuse unit HV 11 KV triple pole out door type and rated capacity 200 Amp mounted on 6 post insulators and steel frames complete including connecting with HV cable leads spirally shaped duly crimped with suitable size lugs complete.
Labour only and T&P for dismantling 11 KV GO/DO air break switch assembly, scrubbing rust from all MS parts and refixing in same position after replacement of deficitive worn out spares (Spares required for replacement shall be measured and paid seprately), lubricating all moving linkeges, setting on HV 4 pole/2pole structure to ensure correct operation complete all as directed.
Supply only male contact or moving contact blade made out of tinned copper/ electrolytic copper suitable for 11 KV GO/DO air break switch assembly.
All as per item No 51 but female contact or fixed contact jaw.
All as per item No 52 but Timed Copper flexible jumper.
All as per item No 53 but MS jumper carrier.
M&L for Dehydration & filtration of transformer oil by using mobile dehydration & filtration plant, heating and filtering the oil to be carried out till the di-electric strength reaches value 50 KV or above in one minute, for any capcacity of transformer (63-250 KVA)/starter of pumps of any type & any capacity.
M&L for topping up/replacement of transformer oil of transformer chamber and conservator with new transformer oil upto a required level of 50 KV di-electric strength to withstand for one minute in any type and capacity of transformer all as specified & directed.
MAA SHAKTI ENGG. CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .