Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.9 L+₹90,725 (6.98%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.5 L+₹2.5 L (19.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.9 L+₹2.9 L (22.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹16.9 L+₹3.9 L (30.2%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Feb 2020, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor
REPAIR MAINT OF WATER SUPPLY PIPE LINE CONTROL VALVES AND VALVE PITS ETC AT TANDA AREA UNDER GE NORTH AKHNOOR
2020_MES_312517_1
GE(N)/AKH-47/2019-20
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
E Class Cat a ii
8 documents required · 8 mandatory
₹500
GE North Akhnoor
₹40,000
Yes
2 Apr 2020
7 Jan 2020
5 Feb 2020
7 Jan 2020
3 Feb 2020
21 Jan 2020
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in loose/soft soil, getting out and leveling the bottom surface to required gradient for laying of water supply mains complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick , all as specified .
Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, all as specified.
Dismentaling/disconnecting and taking out of existing GI tube of 15mm bore dia from the existing walls/floors/roofs for repair/replacement and making good disturbed surfaces complete all as specified.
Ditto all as per item No 04 but 20mm bore dia.
Ditto all as per item No 04 but 25mm bore dia.
Ditto all as per item No 04 but 40mm bore dia.
Ditto all as per item No 04 but 50mm bore dia.
Dismentaling/disconnecting and taking up or down cast iron water mains (including all fittings) from trenches, with spigot and socket ends including burning out lead joints and recovering lead of size 80mm bore dia complete all as specified.
Ditto all as per item No 09 but 100mm bore dia.
Ditto all as per item No 09 but 150mm bore dia.
Ditto all as per item No 09 but 200mm bore dia.
Ditto all as per item No 09 but 250mm bore dia.
Cutting existing GI tubing for alteration/additions and screwing existing GI tubing (lenthening screw on pipe to form connector) for upto 25 mm dia bore.
Ditto all as per item No 14 here-in-before but of size 40/50 mm dia.
Steel water tubing medium grade galvanised of ISI marked with and including fittings such as tees, bends elbow reducer, unions, clamps etc (ISI marked) laid in trenches/ Wall/roof of size 15mm bore dia complete all as specified.
Ditto all as per item No 16 but 20mm bore dia.
Ditto all as per item No 16 but 25mm bore dia.
Ditto all as per item No 16 but 40mm bore dia.
Ditto all as per item No 16 but 50mm bore dia.
Ditto all as per item No 16 but 80mm bore dia.
Ditto all as per item No 16 but 100mm bore dia.
Ditto all as per item No 16 but 150mm bore dia.
Mild steel ERW pipe line 150 mm dia 5.4 mm thickness flanged type confirming to IS 7161 including MS flanges and rubber gasket with reqiired Nos of hole, required Nos of MS connecting pieces and required Nos of nuts, bolts, washers of suitable sizes including cutting of pipes welding work and drilling holes and taking out old CI/DI/MS pipe complete all as specified. Note : Any kind of excavation and earth work related to this work shall be paid under relevant item of this contract
Ditto all as per item No 24 but 200mm bore dia.
Ditto all as per item No 24 but 250mm bore dia.
CI fittings of any size, any type ISI marked as required at site such as bends (any type, radius and angle),Taper any type, (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch. "Y" junction, double branch, cross (all socket or socket and spigot), collar, caps and plugs upto 250mm bore etc. complete all as specified.
Run lead joints for CI pipe 80mm bore dia spigot & soketed/CI fittings including all jointing material required at site complete and directed by Engr-in-charge.
Ditto all as per item No 28 but 100mm bore dia.
Ditto all as per item No 28 but 150mm bore dia.
Ditto all as per item No 28 but 200mm bore dia.
Supplying & fixing in replacement gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipe or for union and fixed including all accessories such as nipple, union etc if required and for size 20mm bore dia complete all as specified.
Ditto all as per item No 32 but 25mm bore dia.
Ditto all as per item No 32 but 40mm bore dia.
Ditto all as per item No 32 but 50mm bore dia.
Stop valve cast copper alloy (ISI Marked) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 20mm bore dia, complete all as specified and directed.
Ditto all as per item No 36 but 25mm bore dia.
Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified and as directed by Engineer-in-Charge
Ditto all as per item No 38 here-in-before but of size 25 mm dia.
Repair to leakage in the pipe line at flanged joints only complete including replacement of Rubber gasket joint complete with necessary jointing materials including replacement of all bolts, nuts and washers where ever required complete including necessary excavation and earth work if required to trace the leakage for CI/DI pipe line of size 100mm to 250mm dia bore.
Supplying & fixing in replacement including testing cast iron sluice valve with flanged ends drilled heavy duty, ISI marked, class PN-1.6 with stainless steel spindle and operating wheel of cast iron at top including necessary nuts, bolts, washers and rubber packing for connecting pieces etc. for size 80mm bore dia complete all as specified.
Ditto all as per item No 41 but 100mm bore dia.
Ditto all as per item No 41 but 150mm bore dia.
Ditto all as per item No 41 but 200mm bore dia.
Ditto all as per item No 41 but 250mm bore dia.
CI Air valve with two air outlets conforming to IS 14845 of size 50mm dia bore and fixing up in cast iron water supply mains of size 150mm complete including taking down the existing one all as specified.
CI foot valve flanged type including nuts bolts washers and rubber of size 150 mm dia confirming to IS-4038 complete including taking down the existing one all as specified.
CI non return valve 250mm dia without by pass arrangement confirming to IS-5312 part-I, PN 1.0 including nuts, bolts, washers and gaskets including taking out old UNSV NRV complete all as specified.
Ditto all as per item No 48 but 150mm bore dia.
Construction of brick masonry valve chamber of size 120 cm x 120 cm x 120 cm (internal dimension) in CM 1:6 including base PCC 1:3:6 type C2 with 40 mm graded coarse aggregate and plastering the walls from inside and outside the chamber as in CM 1:6, provisioning of angle iron frame 40 x 40 x 6 mm and 3.15 mm MS plate as chamber cover with locking arrangement and provn of red oxide primer with two coats of synthetic enamel paint including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition/ dismentling of existing valve chamber complete all as specified.
Ditto all as per item No 50 but size 90cmx90cmx90cm (internal height).
S&F leather packing 6mm thick all as directed and specified.
Taking out unservicable brass/steel spindle of size 150/ 200/ 250mm by unscrewing top cover of sluice valve including taking to the workshop for the required leath work brass welding rebuilding threads etc as required and refix the same for smooth functioning of water supply complete all as specified and as directed
Supply only Lead wool
Supply only pig lead.
Supply and fixing in replacement copper thimbles size 185 Sqmm all as specified and directed.
Ditto all as per item No 56 but size 150Sqmm.
Ditto all as per item No 56 but size 120Sqmm.
Ditto all as per item No 56 but size 95Sqmm.
Supply and fixing in replacement connection cable multistranded single core PVC insulated copper conductor cable through existing PVC/GI Conduit pipe or through existing duct from starter to motor or vice-versa of size of cable 120 Sqmm Complete all as specified. Make : Finolex/Plaza/Kalinga
Surface excavation or surface dressing in hard/dense soil not exceeding average 15CM deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installations/around the valve pit chamber/along the pipe line routes if reqd etc all as specified and as directed.
M/S SAHNI CONSTRUCTION CO
M/s Joginder Lal Malhotra
ASIA ENTERPRISES
Usha Engineering Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .