Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹89.8 LAccepted-AOC A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹92.5 L+₹2.7 L (2.98%)Rejected-AOC | L-2 | Rejected-AOC Being other than the lowest bidder | |
| 3 | L-3₹94.4 L+₹4.6 L (5.12%)Rejected-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L-3 | Rejected-AOC Being other than the lowest bidder | |
| 4 | L-4₹96.9 L+₹7.0 L (7.84%)Rejected-AOC | L-4 | Rejected-AOC Being other than the lowest bidder | |
| 5 | L-5₹99.7 L+₹9.8 L (10.9%)Rejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L-5 | Rejected-AOC Being other than the lowest bidder |
Tender Value
₹97.9 L
EMD Value
₹1.7 L
Closing Date
4 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer, MES, Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (W)/ 12 OF 2020-2021 PROVN OF 33KV AVR 6MVA AT 33KV MRS AND ALLIED WORKS UNDER GE (WEST) BAREILLY
2020_MES_344782_1
8100/B/650/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
BAREILLY
For enlisted contractor Class C Category b iii and for unenlisted contractor meeting the eligibility criteria of class C and category b iii
6 documents required · 6 mandatory
₹1,000
GE West Bareilly
₹1.7 L
Yes
28 Aug 2020
14 May 2020
9 Jul 2020
14 May 2020
4 Jul 2020
13 Jun 2020
14 May 2020 - 11 Jun 2020
60 days
Amount
Supply, installation, testing and commissioning of copper wound HT, AVR of capacity 6 MVA suitable for HV input voltage from 25 KV to 37 KV, band width with HV output voltage 33 KV +/- 1% outer door type oil immersed naturally cooled on load (ONAN) step less type with rolling contact with all standard fittings/equipment such as step down unit,regulator unit buck/boost unit automatic control unit reversing (Q) panel all in built including silica gel breather, temperature gauge, Bucholz relay, WTI & OTI trip & alarm controls and indoor control units with all control cables and control units with following technical specifications of HT/HT AVR and complete all as specified and directed. Make: ANDREW YULE, ICON ENGINEERS, ELECOM TRANSFORMERS, ABB, AREVA. (a) Construction feature: oil immeresed, Naturally cooled on load, stepless, rolling contact brantford type. (b) Mode of operation : Automatic (Note- it shall have all the three type of modes of operations. (c) Service- Outdoor (d) Output- Stabilized distortion less wave form at 33000V +/- 1%, 3 phase, 50 Hz, suitable for balanced/ unbalanced load. (e) Equipment consist of (i) step down/step up unit (ii) Regulating unit (iii) Buck/ Boost unit (iv) Automatic control unit (f) Terminals:(i) Input- Bare bushing as per IS 3347 suitable for 33 KV rating (ii) Output- Bare bushing as per IS 3347 suitable for 33 KV rating (g) Tempreature rise- 50 degree centigrade rise of top oil over an ambient of 50 degree centigrade. (h) Tank & oil- All unit shall be housed inside the sheet steel tank. The number of tanks will depend on design perimeter. Item shall be supplied with first filling of oil confirming to IS 335.
Supply and laying, HT underground cable XLPE insulated, screened with extruded semiconducting compound in combination with copper tape cores laid up, inner PVC sheathed, galvanized steel strip armoured, overall PVC sheathed electric power cable with stranded compact aluminium conductor 33000 volts grade 300 sq mm 3 core confirming to IS:7098 (Part-II) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc including making connection with lugs and crimping complete all as specified and ditrected. Note : 1. The end termination joint shall be measured and paid separately under respective items. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Supply, jointing and testing of outdoor type cable end termination joint (heat shrinkable) suitable for aluminium conductor cable of size 300 Sqmm x 3 Core, 33000 Volts grade. Make : Denson / Raychem / M-seal
Supply & fixing 33 KV 400 Amp isolator out door type, three phase, double break, centre rotating type suitable for manual operation. Each pole of isolator shall be provided with two sets of contacts to be poperated in series and the moving contact blades shall rotate in horizental plane and galvanised steel frame operating pipe of 25mm bore medium grade GI pipe suitable for operation while standing on ground for 3 phase complete all as specified and directed.
Supply, installation, testing and commissioning of a set of 3 Nos lightening arrestors station class single pole non linear register type as per IS 3070 with all fittings discharge capacity 10 KA, rating 30KV(rms) suitable for 33 KV grounded neutral link system fixed on channels, cross arms including connecting to over head line and up to earth pit complete all as specified and directed.
Supply, laying and testing control wiring with PVC insulated, PVC seathed cable galvanised steel strip armoured, heavy duty copper conductor of 4 core 2.5 Sqmm, 1100 Volt grade complete all as specified and directed.
Supply, fabricating and fixing of MS channel, MS angle, flat iron and round bars of any size including drilling of holes, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide primer for isolator, LA, PT, CT, structure and earth mat complete all as specified and directed.
Material and labour for PG clamps, Parallel grove clamps, tee, clamps and GI nuts, bolts of required size and other connectors for connecting ACSR conductors for jumpring as per site complete all as specified and directed.
Supplylaying and and testing of outdoor type (CTs) 33 KV current transformer -03 Nos Dry Type Polycrete having CT ratio 200/100/1+1 for connecting 33 KV side of Transformer bushing class 5P 15 VA burden suitable for protection, metering and differenent operation complete all as specified and directed.
M & L for jumpering PTs, CTs, VCBs, Isolators using ACSR conductor size dog (0/4.72 + 7/1.57) including dismantling old conductor and clamp complete all as specified and directed. Note: Clamp will be measured and paid separatly under relevant item but nut bolts and other accessories required for fixing of clamp and jumpering of conductor shall be deemed to include in the quoted rate.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to earthing test point,main switch board and testing on completion including PCC chamber made by cement concrete 1:3:6 type C-1 and RCC cover 75mm thick with cement concrete 1:2:4 type B1 with MS TMT bar 8mm dia @ 150mm c/c both ways all as shown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected .
M & L for construction of solid brick masonary platform of size 3.0M x3.0M x 1.0M (0.30 mtr high from ground level) in cm 1:6 for mounting 33KV HT AVR 6 MVA capacity. Top of platform shall be provided with 200mm thick PCC 1:2:4 type D2 layer finished even and fair without using extra cement including necessary form work, 15mm thick plaster to brick work in cm 1:4 including excavation in soft and loose soil, returning filling in and removal of surplus soil to a distance n.exc. 50mtr, two coats of cement base opaint over a coat of primer on plastered surface complete all as specified and directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep below ground level for foundation of poles/ stays/cable and getting out complete all as specified .
Returning, filling in, any type of soil and spreading in layers not exceeding 25cm thick each layer including watering & well ramming complete all as specified.
Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified .
Supply and laying of factory made un reinforced pre cast concrete cable protection cover class EHV type - 1 with size 450mm x 230mm x 50mm laid across the cable (i.e width of cover along the length of cable) for cable protection.
Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed and sand cover to under ground cable complete all as specified .
Supply, installation, testing and commissioning of the out door type 33 KV PT of ratio 33KV/rt3/110V/rt3 class0.5-3, burdon 50 VA, insulation level 70 KV, voltage factor 1.2 Cont and 1.9 for 30 sec, confirming to IS 2705 complete all as specified and directed.(For input and output voltage of AVR and tripping system of under/over voltage in the control panel)
JAZZCON ENGINEERS PVT LTD
GEPS PROJECTS
KB PROJECTS
Raman Electric Trading Co
R D Bansal
M/s M.S. Electric Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .