Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.8 CrAccepted-AOC 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹83.8 Cr | L1 | Accepted-AOC being lowest |
| 2 | L2₹83.9 CrRejected-Finance | ₹83.9 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹84.1 CrRejected-Finance | ₹84.1 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹86.1 CrRejected-Finance | ₹86.1 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹86.7 CrRejected-Finance | ₹86.7 Cr | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | Komal Buildcon Pvt. Ltd. L4 | SHRI GURMUKHDAS CONTRACTORS PVT. LTD. L27 | K KUMAR RAJA PROJECTS P LIMITED L22 | Indus Projects Private Limited L16 | HTE INFRA LLP L18 | DES RAJ AND SONS BUILDERS PVT LTD L19 | Hariom Projects Pvt Ltd L29 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L1 | SVS PROJECTS L26 | M/s Matadeen Ramchandra Agarwal L28 | NSC Projects Pvt. Ltd. L6 | jd constructions L11 | SOOD ASSOCIATES PVT LTD L25 | anjaliinfratech L2 | LUMOS INFRA PVT LTD L20 | City Promoter and Buildwell Pvt. Ltd. L8 | RAGHUSONS INFRA ENGINEERING PVT. LTD L9 | M/s Aadhar Stumbh Infra Pvt Ltd L21 | M/s Shree Riddhi Siddhi Buildwell Limited L17 | R V RAYANAM L10 | K GOWDA AND COMPANY L15 | JYOTI ENTERPRISES L3 | CHHABINDRA KUMAR PRADHAN L14 | Som Projects Pvt. Ltd. L5 | NJR Constructions Private Limited L7 | PNSC INFRASTRUCTURE PRIVATE LIMITED L24 | MAHINDER PAL CONSTRUCTIONS PVT LTD L23 | Vriddhi Infratech India Private Limited L12 | SHRADHA SABOORI PROJECTS INDIA PRIVATE LIMITED L13 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .10Schedule "A" Part – I to Schedule "A" Part – XIX: NOTE: Schedule "A" Part – I to Part – XIX are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only | ||||||||||||||||||||||||||||||||
| 1.00 | Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I . | 1 | EACH JOB | 56,19,71,100 ₹56.2 Cr | 67,07,40,000 ₹67.1 Cr | 62,00,00,000 ₹62 Cr | 58,37,76,890.01 ₹58.4 Cr | 63,44,83,500 ₹63.4 Cr | 62,78,36,530 ₹62.8 Cr | 93,66,18,500 ₹93.7 Cr | 54,65,88,295 ₹54.7 Cr | 71,30,39,999 ₹71.3 Cr | 68,40,00,000 ₹68.4 Cr | 55,54,27,300 ₹55.5 Cr | 56,80,13,800 ₹56.8 Cr | 66,33,07,179 ₹66.3 Cr | 55,95,62,300.15 ₹56.0 Cr | 59,19,44,400 ₹59.2 Cr | 53,47,76,742.1 ₹53.5 Cr | 57,30,23,198.3 ₹57.3 Cr | 57,93,11,319.5 ₹57.9 Cr | 65,11,22,947.86 ₹65.1 Cr | 52,26,94,805 ₹52.3 Cr | 58,00,00,000 ₹58 Cr | 51,88,88,000 ₹51.9 Cr | 59,76,23,030 ₹59.8 Cr | 56,00,11,000 ₹56.0 Cr | 55,57,26,216.98 ₹55.6 Cr | 59,00,00,000 ₹59 Cr | 65,00,00,000 ₹65 Cr | 57,76,12,800 ₹57.8 Cr | 61,05,00,000 ₹61.0 Cr |
| 2.00 | Lumpsum price worked out by the contractor for "Site Clearance / Earthwork/ Excavation", as listed in Schedule "A" Part – II . | 1 | EACH JOB | 22,45,931.98 ₹22.5 L | 21,26,100 ₹21.3 L | 20,00,000 ₹20 L | 19,03,226.43 ₹19.0 L | 17,25,000 ₹17.3 L | 19,16,528.63 ₹19.2 L | 29,94,575.98 ₹29.9 L | 12,84,850 ₹12.8 L | 20,39,999 ₹20.4 L | 36,00,000 ₹36 L | 13,41,260 ₹13.4 L | 23,95,660.79 ₹24.0 L | 21,86,040.47 ₹21.9 L | 21,12,620.55 ₹21.1 L | 18,03,522.2 ₹18.0 L | 26,95,117 ₹27.0 L | 21,80,919.74 ₹21.8 L | 20,96,203.19 ₹21.0 L | 17,96,745.59 ₹18.0 L | 29,94,576 ₹29.9 L | 28,00,000 ₹28 L | 17,96,745 ₹18.0 L | 17,96,745.59 ₹18.0 L | 16,50,000 ₹16.5 L | 29,94,575.98 ₹29.9 L | 29,94,575.98 ₹29.9 L | 22,00,000 ₹22 L | 27,90,400 ₹27.9 L | 32,94,033 ₹32.9 L |
| 3.00 | Lumpsum price worked out by the contractor for "Pile foundation", as listed in Schedule "A" Part – III | 1 | EACH JOB | 9,12,12,559.2 ₹9.1 Cr | 10,97,81,000 ₹11.0 Cr | 9,30,00,000 ₹9.3 Cr | 9,05,97,860.64 ₹9.1 Cr | 9,23,42,000 ₹9.2 Cr | 9,22,98,423 ₹9.2 Cr | 10,85,86,380 ₹10.9 Cr | 8,17,44,195 ₹8.2 Cr | 8,82,66,949 ₹8.8 Cr | 12,33,00,000 ₹12.3 Cr | 8,51,41,500 ₹8.5 Cr | 9,07,78,213.68 ₹9.1 Cr | 10,85,86,380 ₹10.9 Cr | 8,42,74,800 ₹8.4 Cr | 11,40,35,000 ₹11.4 Cr | 10,80,90,878.9 ₹10.8 Cr | 8,99,41,012.69 ₹9.0 Cr | 10,85,86,380 ₹10.9 Cr | 8,16,67,800 ₹8.2 Cr | 10,02,06,000 ₹10.0 Cr | 9,40,00,000 ₹9.4 Cr | 9,68,14,550 ₹9.7 Cr | 8,90,40,831.6 ₹8.9 Cr | 9,50,00,000 ₹9.5 Cr | 10,85,86,380 ₹10.9 Cr | 10,31,86,380 ₹10.3 Cr | 9,75,00,000 ₹9.8 Cr | 8,16,41,000 ₹8.2 Cr | 10,60,86,380 ₹10.6 Cr |
| 4.00 | Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IV . | 1 | EACH JOB | 70,49,776.47 ₹70.5 L | 95,03,100 ₹95.0 L | 63,00,000 ₹63 L | 1,19,84,367.55 ₹1.2 Cr | 58,12,815 ₹58.1 L | 59,21,812.23 ₹59.2 L | 93,99,701.96 ₹94.0 L | 1,02,77,035 ₹1.0 Cr | 1,05,89,999 ₹1.1 Cr | 99,00,000 ₹99 L | 1,15,35,720 ₹1.2 Cr | 90,34,040 ₹90.3 L | 78,01,752.63 ₹78.0 L | 82,81,580 ₹82.8 L | 59,06,730 ₹59.1 L | 89,29,715.95 ₹89.3 L | 78,79,676.16 ₹78.8 L | 93,99,701.96 ₹94.0 L | 84,59,731.76 ₹84.6 L | 93,99,701.96 ₹94.0 L | 86,00,000 ₹86 L | 79,17,368 ₹79.2 L | 79,89,746.67 ₹79.9 L | 78,50,000 ₹78.5 L | 62,93,172 ₹62.9 L | 93,99,701.96 ₹94.0 L | 85,00,000 ₹85 L | 96,63,940 ₹96.6 L | 49,85,950 ₹49.9 L |
| 5.00 | Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – V . | 1 | EACH JOB | 55,47,232.23 ₹55.5 L | 60,30,400 ₹60.3 L | 90,00,000 ₹90 L | 77,49,155.44 ₹77.5 L | 53,39,817 ₹53.4 L | 54,27,936.91 ₹54.3 L | 59,64,765.84 ₹59.6 L | 64,28,015 ₹64.3 L | 59,64,765.84 ₹59.6 L | 72,00,000 ₹72 L | 42,02,460 ₹42.0 L | 56,49,816.24 ₹56.5 L | 59,64,765.84 ₹59.6 L | 61,20,820 ₹61.2 L | 62,27,960 ₹62.3 L | 53,68,288.5 ₹53.7 L | 49,40,555.9 ₹49.4 L | 59,64,765.84 ₹59.6 L | 53,68,289.26 ₹53.7 L | 59,64,765.09 ₹59.6 L | 53,00,000 ₹53 L | 50,24,121 ₹50.2 L | 60,84,061.16 ₹60.8 L | 59,64,765.84 ₹59.6 L | 42,19,200 ₹42.2 L | 59,64,765.84 ₹59.6 L | 65,00,000 ₹65 L | 62,79,490 ₹62.8 L | 44,56,950 ₹44.6 L |
| 6.00 | Lumpsum price worked out by the contractor for "Sewage Disposal B/R", as listed in Schedule "A" Part – VI . | 1 | EACH JOB | 7,88,034.23 ₹7.9 L | 9,40,600 ₹9.4 L | 12,35,000 ₹12.3 L | 10,22,463.69 ₹10.2 L | 8,30,986 ₹8.3 L | 9,00,731.6 ₹9.0 L | 8,47,348.63 ₹8.5 L | 8,76,255 ₹8.8 L | 10,54,899 ₹10.5 L | 11,70,000 ₹11.7 L | 7,52,100 ₹7.5 L | 8,79,421.6 ₹8.8 L | 9,06,663.03 ₹9.1 L | 7,80,033.81 ₹7.8 L | 7,70,381.85 ₹7.7 L | 7,62,613.9 ₹7.6 L | 10,52,161.27 ₹10.5 L | 9,74,451 ₹9.7 L | 7,62,613.77 ₹7.6 L | 8,47,348.63 ₹8.5 L | 8,47,348.63 ₹8.5 L | 7,13,721 ₹7.1 L | 8,47,348.63 ₹8.5 L | 8,47,348.63 ₹8.5 L | 6,00,000 ₹6 L | 8,47,348.63 ₹8.5 L | 10,00,000 ₹10 L | 8,40,529.52 ₹8.4 L | 6,00,000 ₹6 L |
| 7.00 | Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – VII | 1 | EACH JOB | 3,72,280.86 ₹3.7 L | 5,47,250 ₹5.5 L | 6,80,000 ₹6.8 L | 4,83,627.18 ₹4.8 L | 5,86,777 ₹5.9 L | 5,39,807.25 ₹5.4 L | 3,72,280.86 ₹3.7 L | 6,67,840 ₹6.7 L | 5,99,999 ₹6.0 L | 5,40,000 ₹5.4 L | 4,45,100 ₹4.5 L | 5,00,122.36 ₹5.0 L | 5,84,480.95 ₹5.8 L | 5,15,435 ₹5.2 L | 4,64,855 ₹4.6 L | 4,46,736 ₹4.5 L | 5,62,780.7 ₹5.6 L | 3,72,280.86 ₹3.7 L | 3,35,052.77 ₹3.4 L | 3,72,280.86 ₹3.7 L | 3,72,280.86 ₹3.7 L | 3,13,571 ₹3.1 L | 3,72,280.86 ₹3.7 L | 5,32,000 ₹5.3 L | 4,91,629 ₹4.9 L | 3,72,280.86 ₹3.7 L | 6,00,000 ₹6 L | 3,19,615.25 ₹3.2 L | 3,35,150 ₹3.4 L |
| 8.00 | Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VIII | 1 | EACH JOB | 82,67,642.85 ₹82.7 L | 1,30,68,200 ₹1.3 Cr | 1,40,00,000 ₹1.4 Cr | 1,30,75,593.07 ₹1.3 Cr | 1,19,10,080 ₹1.2 Cr | 1,23,43,679.67 ₹1.2 Cr | 88,89,938.55 ₹88.9 L | 1,36,79,130 ₹1.4 Cr | 1,33,34,999 ₹1.3 Cr | 1,08,00,000 ₹1.1 Cr | 1,43,15,300 ₹1.4 Cr | 1,10,82,700.48 ₹1.1 Cr | 1,12,90,221.96 ₹1.1 Cr | 1,09,75,270 ₹1.1 Cr | 1,15,30,210 ₹1.2 Cr | 97,78,932.41 ₹97.8 L | 1,23,72,216.38 ₹1.2 Cr | 88,89,938.55 ₹88.9 L | 80,00,944.69 ₹80.0 L | 88,89,938.55 ₹88.9 L | 81,25,000 ₹81.3 L | 74,87,994 ₹74.9 L | 80,00,944.7 ₹80.0 L | 88,89,938.55 ₹88.9 L | 1,29,44,880 ₹1.3 Cr | 88,89,938.55 ₹88.9 L | 1,25,00,000 ₹1.3 Cr | 65,90,960.77 ₹65.9 L | 50,65,850 ₹50.7 L |
| 9.00 | Lumpsum price worked out by the contractor for Roads/Paths/Hard Standing", as listed in Schedule "A" Part – IX . | 1 | EACH JOB | 69,98,196.6 ₹70.0 L | 72,59,800 ₹72.6 L | 1,00,00,000 ₹1 Cr | 71,75,538.55 ₹71.8 L | 74,25,000 ₹74.3 L | 77,83,041.07 ₹77.8 L | 65,40,370.65 ₹65.4 L | 67,74,015 ₹67.7 L | 78,90,899 ₹78.9 L | 72,00,000 ₹72 L | 47,97,400 ₹48.0 L | 66,34,989 ₹66.3 L | 69,98,196.6 ₹70.0 L | 47,34,755 ₹47.3 L | 63,10,185 ₹63.1 L | 65,40,370 ₹65.4 L | 66,16,957.39 ₹66.2 L | 65,40,370.65 ₹65.4 L | 59,48,166.66 ₹59.5 L | 65,40,370.65 ₹65.4 L | 59,00,000 ₹59 L | 42,08,079 ₹42.1 L | 63,44,159.53 ₹63.4 L | 70,00,000 ₹70 L | 65,40,370.65 ₹65.4 L | 65,40,370.65 ₹65.4 L | 75,00,000 ₹75 L | 63,39,047.6 ₹63.4 L | 47,25,650 ₹47.3 L |
Updated dates
Tender Value
₹98 Cr
EMD Value
₹15 L
Closing Date
1 Jan 2026, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
PROVISION OF DEFICIENT OFFICERS MARRIED ACCOMMODATION FOR OFFICERS LT CDR AND ABOVE AT NORA VISAKHAPATNAM
2025_MES_733694_1
85458
Open Tender
Civil Works
730 days
VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹3,000
GE P No3 Visakhapatnam
₹15 L
Yes
30 Mar 2026
4 Oct 2025
8 Jan 2026
4 Oct 2025
1 Jan 2026
18 Dec 2025
S & F CP mixer swan neck for mixing hot and cold water fancy type, chromium plated, fancy type screwed down for pipe, with two outlets going (one for hot and one for cold) kitchen complete all as specified and as directed.
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I .
Lumpsum price worked out by the contractor for "Site Clearance / Earthwork/ Excavation", as listed in Schedule "A" Part – III .
Lumpsum price worked out by the contractor for "Pile foundation", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IV .
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – V .
Lumpsum price worked out by the contractor for "Sewage Disposal B/R", as listed in Schedule "A" Part – VI .
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for Roads/Paths/Culverts", as listed in Schedule "A" Part – IX .
Lumpsum price worked out by the contractor for "Area drainage", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "Compound Wall/ Gate", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "Lightning Protection", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "PVC Conduit", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "Fire fighting and fire alarm system", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "Solar water heater", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "Sewage Disposal E/M", as listed in Schedule "A" Part – XVI .
Lumpsum price worked out by the contractor for "Arboriculture", as listed in Schedule "A" Part – XVII
S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch. Handling and Operation: Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine
Internal Electrification
S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.
Supply and fix, Testing, commissioning of Electric Chimney for kitchen of size 60x30x20 cm, stainless steel sheet with oil filter 20 gauge sheet 304 GI ducting connected up to vertical ducting, angle frame, threding rods, nut bolts along with damper suitable for blower motor of capacity 0.5 HP with starter of suitable size with electric connection all as specified and directed.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
EACH SHIFT OF 08 HRS
PER MONTH
Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
Supply and fixing exhaust fan, 300 mm sweep, metallic body, heavy duty , AC single phase, 230 volts , 5 star rating, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S & F energy efficient LED security light fitting with tube 30 watts new generatiion energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.
Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
M & L for sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 4.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed. Note :(i) Four run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Supply and fix polycarbonate meter box as per IS 14772 with IP -55 weather proof and temperature proof,fire retardant suitable for three phase smart pre-paid meter viewing glass, concealed hinge and earth bolt plugged including cable glands
for incoming and outgoing cables and locking arrangement for top cover of the box without affecting communication complete all as specified and directed.
M & L for sub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed. Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 16 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 16.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through PVC conduit of suitable size complete all as specified and as directed. Note :(i) Four run of 16.0 Sqmm + one run of 16.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCB TPN, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
S & F MCCB DB, vertical double door, TPN, 6 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCB TPN, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral, 8 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral, 4 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
S & F MCCB, 4 pole, 415 V, 50 Hz, 35 KA of capacity 250 Amps complete all as specified and as directed.
S & F MCB TPN 63 Amps, 415 Volts, 10 KA, 'C' complete all as specified and as directed.
S & F MCB TPN 40 Amps, 415 Volts, 10 KA, 'C' complete all as specified and as directed.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S & F MCB TP 40 Amps, 415 Volts, 10 KA, 'C' complete all as specified and as directed.
S & F 15 mm dia Bib taps, long body, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
Lumpsum price worked out by the contractor for "Demolition", as listed in Schedule "A" Part – XVIII
S & F 15 mm dia Bib taps, long body, fancy type, chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed compl
ete all as specified and as directed.
Internal Water Supply
S & F CP mixer for mixing hot and cold water fancy type, chromium plated, screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed.
External water supply
Lumpsum price worked out by the contractor for "DG Set", as listed in Schedule "A" Part – XIX
Schedule "A" Part – I to Schedule "A" Part – XIX: NOTE: Schedule "A" Part – I to Part – XIX are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Cutting the existing DI/MS pipe line of 200 mm dia for alterations or additions necessarily done in position without taking down and inserting Tee of 200 x 200 x 150 mm with and including the Tee for tapping complete all as specified and directed.
Supply, fix ,connecting , testing and commissioning of OEM Manufactured APFC Panel (automatic and manual operation) with 7% Aluminium reactor of capacity 240 KVAR (Output) @ 440 V AC interconnection with LT Panel/ Transformer (outdoor/ indoor) with appropriate size of electric power cable 1.1KV . The stage rating shall be (2 X 12.5) + (4 X 50) KVAR. The APFC Panel shall be fully type tested at an independnt Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017. The degree of protection of enclosure system of the APFC Panel shall be min IP 54 (Outdoor) in accordance with IEC 60529. The capacitor bank shall be internet of things (IoT) enabled and communicable / integrable with BMS . The APFC Panel shall be Outdoor type confirming to IS 13341:1992 & IS13440:1993 floor mounted design fabricated out of 14 SWG CRCA Sheet treated through chemical with 8 tank process method of degreasing, derusting and phosphating powder coating (60-80 microns), painted in SIEMENS GREY (RAL 7032) shade powder coating paint, weather, dust and vermin proof suitable for humidity upto 95% and having four Nos iron legs made of 50x50x6mm thick, 60cm long angle iron below frame with front door and side/ back opening having locking arrangement prewired with copper conductor PVC insulated wire size 2.5sqmm/ extension strips and connected with suitable size thimbles & lugs. The legs duly embedded in ground (45cm) in PCC 1:3:6 type C1 (using 20mm aggregate). Cable entry from bottom. Transparent Acrylic sheet/Bakelite sheet will be provided for shrouding. Average daily temperature :+35 degree celcius max, Ambient temperature :-5 degree celcius to 40 degree celcius, Maximum altitude 2000m. Approved Make of Panel:-ABB/SCHNEIDER/SIEMENS/L&T/CMKL . The OEM 's specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf .
Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified and as directed.
Supply, install, testing and commissioning of centrifugal pump set electric driven 25 HP capacity, including star delta starter of appropriate rating , necessary PCC foundation for pump set and starter anlge iron base of suitable size for installation of the pump set also deemed to inclusive, suitable size of copper cable for connection of pump set (Starter should be fixed on panel) complete all as specified and directed.
Supply and fix foot valve of size 100 mm Complete all as specified and as directed.
External Electrification
Carrying out routine load test [Compression] on 900mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 900mm dia piles, complete all as specified and directed.
Supply and fix direct cylinder mounted type vacuum chlorinator for pressure feed including all guages, pump, motor conforming to IS 10553 Part - 2 having capacity 1.0 to 1000 gm/hr complete all as specified and as directed.
Carrying out low strain integrity test on 900mm dia piles including analysing the results complete all as specified and directed.
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc., used are to be made of rust proof material including as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 3000 A capacity complete with powder coating, necessary internal electric connection as required and provision and including the following
a) ACB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 800 A breaking capactiy 50kA, Manual draw out type - 01 No [Incoming] b) MCCB AC 3 Phase 415 V, 50Hz,4 pole 630 A breaking capactiy 50kA, Manual draw out type - 02 Nos (Bus bar trunking). ( Outgoing) c) Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers. d) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers.
(a) ACB 2000 A AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole breaking capactiy 50kA, Manual draw out type - 01 No (b) MCCB 630 A AC 3 Phase 415 V, 50Hz,4 pole breaking capactiy 50kA, Manual draw out type - 02 Nos c) MCCB 100 A AC 3 Phase 415 V, 50H z 4 pole breaking capactiy 35kA with adjustable type thermal and magnetic setting relays - 01 No d) MCCB 320 A AC 3 Phase 415 V, 50H z 4 pole breaking capactiy 35kA with adjustable type thermal and magnetic setting relays - 01 No e) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 pole breaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 No f) ACB 800 A AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole breaking capactiy 50kA, Manual draw out type - 01 No Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers. g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers.
LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1250A capacity complete with powder coating, necessary internal electric connection as required and provision of the following
LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed ,
a) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 pole breaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming) b) MCCB 100 A AC 3 Phase 415 V, 50 Hz 4 pole breaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 08 Nos c) MCCB 32 A AC 3 Phase 415 V, 50H z 4 pole breaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 No d) MCB10 A SPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 02 Nos e) MCB 32 A SPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 03 Nos f) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
The APFC Panel manufacturered by OEM's only will be accepted & factory acceptance test (FAT) will be carried out at OEM's plant only.The APFC Panel shall be comprising of the following:-
Fire fighting and fire alarm system
Loop in loop out box of FRP made with IP 65 protection of thermoplasic of size 205 x 255 x 112mm with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as PVC connector heavy duty 32Amps,4 way for cable with necessary fixing arrangemets and with cable glands, etc., complete all as specified and directed.
Supply and fix time switch 250 V, single phase of max 20 Amps rated, with contactor fitting inside steel encloser.
Supply and fix 6 kg Capacity dry chemical power (ABC) fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed.
Supply and fix 4.5 kg Capacity CO2 type (light weight squeeze grip type) fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed.
PVC Conduit
Supply and fix telephone sockets (Jack type) RJ 11-1 with shutter 1 module with all accessories complete all as specified and directed.
Supply and fix TV co-axial socket 1 module with all accessories complete all as specified and directed.
Supply and fix factory fabricated GI Metal flush boxes suitable for 1-2 module complete all as specified and directed.
Supply and fix 9 Ltr Capacity mechanical foam type fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed.
Supply and fixing of GI junction boxes of size 150 mm x 100 mm x 60 mm with cover plate Complete all as directed.
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
Supply and fix RJ 45 jack internet socket 1 module with cover plate complete all as specified and as directed.
Sewage Disposal E/M
M & L for masonry valve chamber of size 750 X 750 X 750 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
Supply and fix 9 Ltr Capacity mechanical foam type fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed.
Supply and fixing of GI junction boxes of size 150 mm x 100 mm x 60 mm with cover plate Complete all as directed.
DG Set
Taking down old/ unserviceable submain wiring of any description complete all as specified and directed.
Taking down old burnt/ unserviceable light fittings of any description/ capacity complete all as specified and directed.
Taking down old burnt/ unserviceable ceiling fans, wall fans, exhaust fans of any description/ capacity and deposit to AGE E&M store yard complete all as specified and directed.
Taking down old burnt/ unserviceable main switches and DB's including MCB SP/SPN/TPN of any make and any size, wooden board, junction box and making good disturbed surfaces of wall complete all as specified and directed.
Supply, install, testing and commissioning of silent Diesel Engine Generating set including accoustic enclosure as per latest CPCB norms 415 Volts 125KVA, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS-4722, BS-5514/2613/5000 with AMF Panel and including the following including accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS:10002, ISO-3046, BS-5514 and Alternator as per IS:4774, BS EN 60034-1 with the following accessories including necessary suitable size PCC foundation, GI pipe for laying of cables etc., all as per manufacturers instructions complete all as specified and directed Make: Kirloskar/ Cummins/Ashok Leyland/ Jyoti/ Crompton
(xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories : AVM pads built or separtely mounted to manufacturer base frames. (xv) Base frame: Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer. (C) AMF panel: Factory made indoor type control cubical made out of 2 mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 Volts, 3 phase, 4 wire, AC, 50 Hz, including powder coated, aluminum bus bar of one and half times the rated load of 58.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses name plates consisting of 4 pole MCCB's and contactors and relays of capacity as recommended by the manufacturer, detachable cable gland plates all controls, indicators and Micro processor base LED/LCD display for indication voltage, current, frequency, speed, KW, KWH, PF, temperature,battery voltage,etc with the following:-
(xv) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set green. The base frame should be painted with epoxy based black shade (xvi) Rubber matting of LV grade 19 mm thick of suitable size, chequered type, ISI marked shall be laid in front of control panel. (E) Testing: The DG set shall be tested for a period Not less than 12 hours continuously out of which at least 1/2Hr on No Load and 02 hrs on 25% load, 02 hours each on 50% and 2.5 hrs on 75 % of rated full load, 4 hours on rated full load and 01 hours on 10% in exceess of rated full load. Necessary load shall be given on connected load. If the required full load for testing purpose is not available at the site, artificial load has to be arranged by the contractor for the testing. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. Contractor shall arrange DHPP for testing of DG set . Unit rate quoted shall deemed to include cost of the same.
LIFTS
Supply and installation testing and commissioning of Non-clogging submerssible pump set electric driven with chrome steel impeller of min flow 500 LPM ,Head 25 mtr and minimum capacity 5 HP capacity (1 Working+ 1 Stand by) inside raw sewage tank with float switch, lifting arrangement cabling, installation complete along with the basic requirement of motor protection ,with electric starter panel and shall have automatic start-stop senser device according to the levels in the sump. The reverse rotation system shall be incorporated in the pump design to ensure that the pump does not start rotating in the reverse direction due to wrong electrical connection including with all
a) Fire man switch. (b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity or batteries designed for running the lift with full load. © Battery operated emergency light (LED Ceiling fitting) alarm ( speaker for emergency alarm system to be fixed) and stop button in car with rechargeable areangement for battery). (d) Suitable decorative ligting arrangement inside the lift (e) One sleek circular PVC heavy duty fan in false ceiling. (f) Aluminium chequred plate (3 mm thick) as flooring joint in chequred plate should not more than one and top covering with PVC flooring complete. (g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping system having relay etc. (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
(k) Car size shall be conform to IS -3531-1976 and body to be stainless steel of 16 gauges moon rock finish with stainless steel hand rail 38 mm hairline finish. (l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4 mm thickenss of suitable size as specified. (n) Opening with glass door of 5 mm thick 200 x 600 mm size in all the doors. (o) Specification plate with complete details. (p) Continuous earthing for machine and equipments. (q) Steel wire rope of adequate size as per relevent IS and as per manufacturer specifications. (r) Other standard fixtures and fittings like guide rail, sheaves counter weights with guards, buffer gear unit brakes, control panel, lock, governor, car operational panel, control and trailing cables complete. (s) Full length display indicator panel. (u) Suitable phase reversal relay shall be provided on the controller to protect lift /equipment against phase reverse, phase failure and low voltage.
(v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800 mm with toughended glass not less than 08 mm thick. (w) Intercom be connected with nearest sucurity post. Note:a) Cost of lift inspector inspection is deemed to be inclded in the item rate. provision of one lamp holder, one socket with PVC box of sitable size to be provided at the top of lift for servicing. b) one lift of 13 passengers only has to be provide with all necessary facilities require for fire lift as per NBC -2016.
Schedule "A" Part - XX [Miscellaneous Items]
Aviation light
Supply and fix Aviation obstruction light LED type fitment-less bulb with 10 Watt bulb complete including standard fixing arrangement complete all as specified and as directed
S & F Cable PVC insulated LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calamps spacers bolts nuts etc complete all as specified and as directed
S & F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit junction boxes of size 205 x 255 x 112 mm for cable entry and exit combi climate cable glands of IP 66/IP67 for cable entry and grommets IP 65 for conduit of cable exit with MCB SP 6 Amps, 10 KA, C curve over load and short circuit protection terminals as PVC connector heavy duty 32 Amps, 4 way for cable with necessary fixing arrangements an with cable glands, etc complete all as specified and as directed
Supply and fix time switches 250 Volts, single Phase, 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and as directed
Supply, Install, testing and Commissioning AC three phase static eletronic meter of accuracy class 1.0, 240 Volts, 50 Hz, with backlite LCD display of rating 10-60 Amps six month history complete all as specified and directed.
Electronic chimney
acessoriers all as directed. Note:The cost of starter panel,sensor,float switch shall be included in the unit rate.
Supply and fix sheet metal encloser indoor type feeder panel with provision of fixing incoming and out going cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. Incomming:- (a) MCCB 32 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TPN - 03 Nos(for two 5 HP pumps + 01 Spare) (b) MCB 16 Amp,16 KA SPN - 02 Nos(for bldg + 01 Spare) (c) LED Indicating Lamps for each phase with colour Red Yellow Blue for R, Y and B Phases-03 Nos (d)Multifunctional digital Meter.
Boring for bored cast in situ piles 900 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 900 mm dia in hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Carrying out Initial load [Compression] test on 900mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 900mm dia piles, complete all as specified and directed.
Each bag of 50 Kg
Supply of approved manure (cow dung) complete all as specified and as directed
Supply & Planting Ashoka Plant including preparation complete all as specified and as directed
Supply & planting Royal palm tree plant including preparation complete all as specified and as directed
DEMOLITION
Arboriculture
Supply and fix bus bar trunking system for the complete bldg power supply duly insulated 630 Amps ,three phase ,100% Neutral
Aluminium conductors sandwich busduct IP 55 with short circuit breaking capacity of 36 KA for 1sec. Insulated aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with suitable MCCB 4P with rotary handle, termination links of bldg etc.
Supply, install and testing of LT Panel board made out of CRCA sheet 2 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required with and inclusive of following items: (Pump House Panel) I/C (a) LT 440 volts 3 phase, 4P, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, No-Volt thermal based release.-01 No (b) MCCB 63 Amp 3P, 50 Hz, 415 Volts complete - 03 Nos (c) MCB C-Curve, 16 Amp SPN, 50 Hz, 240 Volts complete -01 No d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases-01 [set of 03]
Supply only appoved loose soil/sweet earth best quality for plant complete all as specified and as directed
Supply only approved vermi compost of the best quality complete all as specified and as directed
PHASE -IV OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 AND 85 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
All as per Serial Item No. 20 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% (v) Frequency regulation +/-1% (B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
All as per Serial Item No. 20 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified.
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% (v) Frequency regulation +/-1% (B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
All as per item No.20 here-in-before but controlled by two two way switch complete all as specefied and directed.
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5% (v) Frequency regulation +/-1% (B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
All as per Serial Item No. 20 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per item no 84 above but for capacity 08 Passenger (544 Kgs).
stage.html
html • 0.13 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.96 MB
tender.pdf
Tender Documents • 2.75 MB
BOQ_821503.xls
BOQ • 0.39 MB
schedules.pdf
Additional Documents • 0.59 MB
STRLDRGS.rar
Additional Documents • 7.46 MB
Download all tender documents and submit your bid