Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹19.5 L+₹60,556 (3.21%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹21.3 L+₹2.4 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹21.4 L+₹2.6 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.8 L+₹6.9 L (36.5%)Rejected-Finance KHATA NO 254 529 KHASRA NO 364 2 MIN PREET NAGAR A GALI NO 2 HARERI ROAD OPP STAR STUDIO HERARI SANGRUR | SANGRUR | SANGRUR | PUNJAB | L5 | Rejected-Finance Other than lowest |
Tender Value
₹24.4 L
EMD Value
₹48,800
Closing Date
12 Dec 2022, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001
SPECIAL REPAIR/REPLACEMENT OF OVER HEAD LINE TO UNDERGROUND XLPE CABLE OFFRS JCO/OR MD ACCN AT DHOLEWAL MIL COMPLEX UNDER GE LUDHIANA
2022_MES_563065_1
GE/LDH-58/2022-23
Open Tender
Civil Works
Item Rate
180 days
Dholewal Cantt
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹48,800
Yes
29 Dec 2022
14 Nov 2022
13 Dec 2022
14 Nov 2022
12 Dec 2022
28 Nov 2022
14 Nov 2022 - 27 Nov 2022
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed.
Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed .
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed.
Supplying and laying bricks common brunt clay building bricks sub class B incl removing of old bricks complete all as specified and directed.
M & L for sand cushioning in trenches and well ramming in layers for cable cushioning with fine dry sand and complete all as specified and directed.Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment.
Dismandling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT pole/ Lines all as specified and directed .
Supply, laying, jointing, testing and commissioning in replacement of 16 Sqmm 4 core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 35 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 50 Sqm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 70Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 95 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, on pole complete all as specified and directed
Supply and fix of Aluminium Lugs uitable for 16 to 35 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed .
Supply and fix of aluminium Lugs suitable for 70 to 95 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed.
Supply and fixing in replacment GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking up old GI pipe complete all as specified and directed.
All as per ser item No 14 here-in-before but size 50 mm dia
Supply and fixing in replacment GI pipe light grade 80 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah complete all as specified and directed
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated aluminium bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under.:- (i) Aluminium bus bar strip of capacity 630 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 400 Amps with adjustable thermal release 4 pole 415 volts 36 KA repturing capacity - 01 Nos. Make for MCCBs:- Havells/L & T/ABB/Legreand/C&S/Indo- Asian (iii) Out going MCCB of current rating 125 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 02 Nos. Make for MCCBs:- Havells/L & T/ABB/Legreand/C&S/Indo- Asian (iv) Out going MCCB of current rating 100 Amps with adjustable thermal release 4 pole 415 volts 16 KA repturing capacity - 03Nos. Make for MCCBs:- Havells/L & T/ABB/Legreand/C&S/Indo- Asian (v) Digital voltmeter (0-500 volt) 96x96mm (vi) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s (vii) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated aluminium bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under.:- (i) Aluminium bus bar strip of capacity 630 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 400 Amps with adjustable thermal release 4 pole 415 volts 36 KA repturing capacity - 01 Nos. Make for MCCBs:- Havells/L & T/ABB/Legreand/C&S/Indo- Asian (iii) Out going MCCB of current rating 125 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 02 Nos. Make for MCCBs:-Havells/L & T/ABB/Legreand/C&S/Indo- Asian (iv) Out going MCCB of current rating 100 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 02 Nos. Make for MCCBs:-Havells/L & T/ABB/Legreand/C&S/Indo- Asian (v) Out going MCB of current rating 40 Amps with 10kA, C series- 02 Nos.Make for MCBs:-Havells/L & T/ABB/Legreand/C&S/Indo- Asian (vi) Digital voltmeter (0-500 volt) 96x96mm (vii) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated aluminium bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under.:- (i) Aluminium bus bar strip of capacity 400 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 250 Amps with adjustable thermal release 4 pole 415 volts 36 KA repturing capacity - 01 Nos. Make for MCCBs:-Havells/L & T/ABB/Legreand/C&S/Indo- Asian (iii) Out going MCCB of current rating 100 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 04 Nos. Make for MCCBs:- Havells/L & T/ABB/Legreand/C&S/Indo- Asian (v) Digital voltmeter (0-500 volt) 96x96mm (vi) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s (vii) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
M& L for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6 mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire soldered and riveted or connected to earth plate by means of nuts, bolts , check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire 4 mmm dia duly protected with and including 15 mm dia bore medium grade GI pipe upto 7.5 (maximum) meter from electrode to earth point including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate and GI light grade watering pipe of 20mm dia bore with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50 mm thick RCC cover using cementconcrete 1:2:4 type B-0 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work and MS frame using MS angle of size 40mm x 40mm x 6mm complete all as specified & directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to the department.
M&L for LT straight through 1100 volt grade for cable for heat shrink type joint kit complete with jointing material and accessories suitable for 4 core 16 to 50 sqmm XPLE armoured aluminium conductor cable complete all as specified.
M&L for LT straight through 1100 volt grade for cable for heat shrink type joint kit complete with jointing material and accessories suitable for 4 core 70 to 120 sqmm XPLE armoured aluminium conductor cable complete all as specified.
M & L for sub main wiring complete with 2 runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed/ surface in wall/Ceiling etc all as specified and as directed. Note:- Three run of cable shall be measured in one unit.
S& F for polycarbonate thermoplastic outdoor junction box for steet lights with flap cover operate with IEC 61439-3 which should be shock proof, protection class-II, earthed , IP 65 weather proof , corrision free , acid and chemical resistant , impact resistant, , ultra voilet resustant made of halogen & silicone free recyclable mtrl, internally embedded gasket with provision for cable entry through integrated flanges top and bottom,The gasket should be internally embedded made of polycarbonate incl with fixing arrangement ( clamps, nuts and Bolts etc.) complete all as specified.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks including necessary form work and fair finish to exposed surfaces without using extra cement etc, complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40mm crushed stone aggregate complete all as specified and as directed
Cutting of black top of road for laying of XLPE LT cable 11000 volt and after laying of cable repairing of road with cement (1:2:4 ), concrate/ bituman surface complete all as specified & directed
GULSHAN SINGH GHAI AND SON
JASSI TRADERS
CHOUDHARY ENTERPRISES
JINDAL AND COMPANY
R K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .