Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.7 L+₹3.9 L (15.6%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance HIGHER THAN LOWEST BIDDER | |
| 3 | L3₹32.1 L+₹7.2 L (29.0%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L3 | Rejected-Finance HIGHER THAN LOWEST BIDDER | |
| 4 | L4₹33.5 L+₹8.7 L (34.8%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L4 | Rejected-Finance HIGHER THAN LOWEST BIDDER | |
| 5 | L5₹36.5 L+₹11.6 L (46.9%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance HIGHER THAN LOWEST BIDDER |
Tender Value
₹34.7 L
EMD Value
₹69,400
Closing Date
29 May 2023, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
REPAIRS/ MAINT OF EXTERNAL WATER SUPPLY, REPAIRS/MAINT TO LT EXTERNAL ELECTRIFICATION REPAIRS AND MAINT OF SECURITY/ PERIMETER LIGHT/ HIGH MAST LIGHT/ SOLAR LIGHTS/GARDEN LIGHTS AND CONNECTED ITEMS AND REPAIRS/MAINT/ SERVI-CING TO DG SETS, LT PANELS
2023_MES_591541_1
8525/T-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
ALONG
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹69,400
Yes
29 Jun 2023
28 Apr 2023
30 May 2023
28 Apr 2023
29 May 2023
17 May 2023
28 Apr 2023 - 4 May 2023
Amount
EARTH WORKS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Water Pipe Line, Cable, Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Mete for Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Water Pipe Line, Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed.
M&L Cutting on Existing Road not exc. 1.00 Metre in Depth and not exc. 0.50 Metre in Width including Making Good the Same with Cement Concrete 1:3:6 (40mm graded stone aggregates) not exc. 200mm thick on Top Layer after necessary Returning, Filling in, Well Ramming and Levelling in Layers to match the Existing Surface Levels, complete all as specified and as directed. NOTE : Cement Concrete 1:3:6 (40mm graded stone aggregates) not exc. 200mm thick will be Measured & Paid separtely under appropriate Item.
REPAIRS & MAINT TO EXTERNAL WATER SUPPLY
Taking down/ up Galvanised Steel Tubing 15mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Taking down/ up Galvanised Steel Tubing 20mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Taking down/ up Galvanised Steel Tubing 25mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Taking down/ up Galvanised Steel Tubing 32mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Taking down/ up Galvanised Steel Tubing 63mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Taking down/ up Galvanised Steel Tubing 90mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Taking down/ up Galvanised Steel Tubing 100mm bore (dia) with Connections/ Fittings of any description, complete all as specified and as directed.
Supply & Laying/ Fixing Galvanised Steel Tubing 15mm bore (dia), medium grade, conforming to IS-1239 with all Connections/Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed
Supply & Laying/ Fixing Galvanised Steel Tubing 20mm bore (dia), medium grade, conforming to IS-1239 with all Connections/Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed
Supply & Laying/ Fixing Galvanised Steel Tubing 25mm bore (dia), medium grade, conforming to IS-1239 with all Connections/Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed
Supply & Laying/ Fixing Galvanised Steel Tubing 100mm bore (dia), medium grade, conforming to IS-1239 with all Connections/Fittings required at Site(s), fixed to Walls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe 20mm Outer dia, SDR 7.4 (PN 16) and Fittings having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe 25mm Outer dia, SDR 7.4 (PN 16) and Fittings having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe 32mm Outer dia, SDR 7.4 (PN 16) and Fittings having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe 63mm Outer dia, SDR 7.4 (PN 16) and Fittings having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe 90mm Outer dia, SDR 7.4 (PN 16) and Fittings having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
S&F Bib Tap 15mm bore (dia), Cast Copper Alloy, screwed down, High pressure, with Crutch or Butter-fly Handle, screwed Both Ends for Unions/ Sockets including Taking down/out Unserviceable Bib Tap of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 15mm bore (dia) with Iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 20mm bore (dia) with Iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 25mm bore (dia) with Iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 32mm bore (dia) with Iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 40mm bore (dia) with Iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed.
S&F Gun Metal Globe/ Gate Valve 50mm bore (dia) with Iron Wheel Head, ISI Marked, screwed Both Ends for Iron Pipe including Taking down/out Unserviceable Globe/ Gate Valve of any description, complete all as specified and as directed.
M&L Dismantling Joints of Flanged Pipe 80mm bore (dia) in Position and Removing Old Rubber or Fiber Gasket, Bolts and Nuts, etc., complete all as specified and as directed.
S&F GI Long Nipple suitable for GI Pipe 80mm bore (dia) having 150mm long with Nuts, Bolts and Rubber Gasket including Taking down/out Unserviceable Long Nipple, complete all as specified and as directed.
M&L Cast Iron Butter-fly Valve 80mm bore (dia), Wafer type, Flanged and drilled both Ends, ISI marked, conforming to IS:13095 with all Jointing Materials such as suitable size Mild Steel Nuts, Bolts, GI Washers, Rubber Gasket, etc. and Testing against Leakage including Taking out/ down Unserviceable Butter-fly Valve, complete all as specified and as directed.
M&L Cast Iron Non-Return Valve 80mm bore (dia) with all Jointing Materials including Taking out/ down Unserviceable Non-Return Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 80mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Construction Valve Pit Chamber of Size 45x45x45 Cm (Internal Dimension) with 100mm thick Lean Concrete 1:4:8 (40mm graded stone aggregate) at Foundation, 200mm thick Pre-cast Cement Concrete Block Walling in Cement Mortar 1:4 with Solid Blocks of Size 300x200x200mm or 300x200x100mm having Compressive Strength not less than 100 Kg/ Sq Cm (as per IS-2185) in Cement Concrete 1:3:6 (20mm graded stone aggregates), Rendering 15mm thick to Block Walling in Cement Mortar 1:4, Internally Complete Surfaces (except PCC Foundation Bed), Externally upto 150mm below Normal Ground Level, Providing Mild Steel Sheet Cover 3.15mm thick, fitted Hinges, Handle and Locking Arrangement welded on Mild Steel Angle Iron Frame 40x40x5.0mm at Top of Valve Pit Chamber, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick provided at Top of Block Walling, applying Two coats of Black Paint over a coat of Red Oxide Zinc Chrome Primer to all Steel Surfaces after Preparation of Surfaces including necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Pit Chamber, complete all as specified and as directed.
M&L Construction Valve Pit Chamber of Size 90x90x90 Cm (Internal Dimension) with 100mm thick Lean Concrete 1:4:8 (40mm graded stone aggregate) at Foundation, 200mm thick Pre-cast Cement Concrete Block Walling in Cement Mortar 1:4 with Solid Blocks of Size 300x200x200mm or 300x200x100mm having Compressive Strength not less than 100 Kg/ Sq Cm (as per IS-2185) in Cement Concrete 1:3:6 (20mm graded stone aggregates), Rendering 15mm thick to Block Walling in Cement Mortar 1:4, Internally Complete Surfaces (except PCC Foundation Bed), Externally upto 150mm below Normal Ground Level, Providing Mild Steel Sheet Cover 3.15mm thick, fitted Hinges, Handle and Locking Arrangement welded on Mild Steel Angle Iron Frame 40x40x5.0mm at Top of Valve Pit Chamber, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick provided at Top of Block Walling, applying Two coats of Black Paint over a coat of Red Oxide Zinc Chrome Primer to all Steel Surfaces after Preparation of Surfaces including necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Pit Chamber, complete all as specified and as directed.
Dismantling Wrought or Mild Steel Works of any description not otherwise provided for, complete all as specified and as directed.
M&L Mild Steel Work such as Bracings, Supports, Clamps and Back Plates, etc., fabricated from Structural Steel Sections including necessary Welding, Bending Cold or Hot, Drilling Holes for Bolts, in any Shape or Size as indicated or directed including applying Two Coats of Aluminium Paint over a Coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
M&L Mild Steel Screw Bolts (machine made) with Hexagonal or Square Heads at One End and screwed the Other, or screwed Both Ends, Each screwed End to be fitted with Washers and One Hexagonal or Square Nut, Length of Bolt of existing Sizes, complete all as specified and as directed.
Supply & Mixing Calcium Hypo Chlorite (Altock GP/ Aquafit) 65%-70% Chlorine Contents (Calcium based Granuar Disinfectant for Water Treatment Chemicals as approved by GE) and Mixing time-to-time to obtaine Clear Drinkable Water and proper Chlorination of Water i.e. 2.0 PPM at Pump House and 0.2 PPM at User End, complete all as specified and as directed. NOTE : Manufacturer's Test Certificate for Each Lot alongwith Original Purchase Voucher shall be furnished by the Contractor for Payment.
M&L Dewatering Water from Pressed Steel Storage Water Tank 50000 Litre capacity, having 3.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls and Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters "TANK CLEANED ON : XX.XX.XXXX" (Date of Cleaning) exc. 50mm and not exc. 100mm on the Front/ Road Side Face of the Tank, complete all as specified and as directed. NOTE :- (a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account. (b) Cleaning of Steel Storage Water Tank will be carry out for 2 Times within the Contract Period.
M&L Dewatering Water from Pressed Steel Storage Water Tank 80000 Litre capacity, having 3.00 Metre High Steel Stagging, Cleaning and Removing all Mosses, Algae, Dirts, etc. from the Walls and Floor of Water Tank, Removal of Dirty Water with Sludges and disposed off from the Site as diredted, Rubbing Walls, Floor, Ceilling surfaces with Gunny Bag after sprinkling of Bleaching Powder and Wash thoroughly with Fresh Water including Cleaning of Outlet Pipes, Stop Valves, Gate Valves by Taking out Pipe Lines with Stop Valves, Gate Valves, etc. and all Accessories, Re-fixing the same after Cleaning including Float Valve with Float Arm to Original Position, Writing Letters "TANK CLEANED ON : XX.XX.XXXX" (Date of Cleaning) exc. 50mm and not exc. 100mm on the Front/ Road Side Face of the Tank, complete all as specified and as directed. NOTE :- (a) Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Steel Storage Water Tank will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account. (b) Cleaning of Steel Storage Water Tank will be carry out for 2 Times within the Contract Period.
M&L Preparing Surfaces of Pressed Steel Storage Water Tank 50000 Litre Capacity having 3.00 Metre High Steel Stagging and Removing Rust, etc. by Rubbing with Wire Brush, etc. from Outer Walls and Steel Stagging and applying Two Coats of Aluminium Paint on Outer Surface Area of Tank and Steel Stagging and applying One Coat of Black Bituminous Paint (suitable for Drinking Water Purpose) to Inside Portion of Storage Water Tank and all connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as requi-red for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Preparing Surfaces of Pressed Steel Storage Water Tank 80000 Litre Capacity having 3.00 Metre High Steel Stagging and Removing Rust, etc. by Rubbing with Wire Brush, etc. from Outer Walls and Steel Stagging and applying Two Coats of Aluminium Paint on Outer Surface Area of Tank and Steel Stagging and applying One Coat of Black Bituminous Paint (suitable for Drinking Water Purpose) to Inside Portion of Storage Water Tank and all connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as requi-red for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Preparing Surfaces of Iron Removal Plant 5500 GPH Capacity by rubbing of Surfaces with Wire Brush and removing rust, etc. from the Outer Surfaces of Iron Removal Plant and applying Two Coats of Aluminium Paint on Outer Area of Iron Removal Plant and all Connected Assesories like all GI Pipes, Valves, Other Fittings, etc., complete all as specified and as directed. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as requi-red for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
REPAIRS & MAINT TO PUMPS & MOTORS
M&L Lifting of Submersible Pump & Motor Assembly 7.5 HP alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 7.5 HP to AGE E/M Store Yard at ALONG, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to include in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
M&L Dismantling Submersible Motor 7.5 HP, Taking out burnt Windings, Cleaning of Slots of the Motor and Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the Same and Testing for Smooth Functioning after Rewinding, complete all as specified and as directed.
M&L Lowering down Submersible Pump & Motor Assembly 7.5 HP (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Materials viz Column Pipes and Other Materials, etc. (obtained from Item No. 3.01 here-in-before) keet in Safe Custody will be reuse. Sumbersible Cable will be replaced with New Cable and the same will be Measured and Paid separately under appropriate Item as 'Supply only'.
Supply only PVC insulated, sheathed Stranded Copper Conductor Water Proof Cable, Flat, Cross-sectional Area 6.0 Sqmm, 3 Core, 1100 Volt grade, conforming to IS:694 for suitable for Sumbersible Pump & Motor Assembly 7.5 HP, complete all as specified and as directed.
M&L Taking out existing Mono Block Pump Set 10 HP/ 20 HP for Minor Repairs, Replacement of rusted Bolts, Nut, Washers with New One of existing Size, Greasing Pump Set for Smooth Functioning and Reinstalled the Pump in the same Position after repaired, complete all as specified and as directed.
M&L Opening Strip of Monoblock Pump Set 10 HP, Removing Mono-block Pump Set to AGE E/M Store Yard at ALONG, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Pump Set as required, Transporting defective Pump Set to nearest Workshop to carry out Repairing/Rewinding, Dismantling Pump Set, Taking out burnt Copper Windings, Cleaning of Slots of the Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the same and Testing for Smooth Fucntioning after Rewinding, Transporting Back to Worksite after Repaired, Reinstallation and providing all Connection, Testing in presence of JE/Engineer-in-Charge, complete all as specified and as directed.
M&L Opening Strip of Monoblock Pump Set 20 HP, Removing Mono-block Pump Set to AGE E/M Store Yard at ALONG, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Pump Set as required, Transporting defective Pump Set to nearest Workshop to carry out Repairing/Rewinding, Dismantling Pump Set, Taking out burnt Copper Windings, Cleaning of Slots of the Motor, Rewinding the same with Super Enamalled Copper insulated Wire of suitable Gauge and Weight as per existing including necessary Insulation Materials, Varnishing, Heating, Reassembling the same and Testing for Smooth Fucntioning after Rewinding, Transporting Back to Worksite after Repaired, Reinstallation and providing all Connection, Testing in presence of JE/Engineer-in-Charge, complete all as specified and as directed.
M&L Sealed Ball Bearing (No. 6307 or as per existing/approved), suitable for Mono Block Centrifugal Pump Set 10 HP/ 20 HP and Repairing Shaft for Bearing hoisting for Pump Set including Taking out Unserviceable Bearing from Pump Set, complete all as specified and as directed. MAKE : NBC/SKF/TATA
M&L Sealed Ball Bearing (No. 6308 or as per existing/approved), suitable for Mono Block Centrifugal Pump Set 10 HP/ 20 HP and Repairing Shaft for Bearing hoisting for Pump Set including Taking out Unserviceable Bearing from Pump Set, complete all as specified and as directed. MAKE : NBC/SKF/TATA
S&F Automatic Star Delta Starter 10 HP, 415 Volt, 50 Hz with Outgoing and Incoming Cable Connections to the existing Monoblock Pump Set and Testing on Full Load including Taking out/ down Unserviceable Star Delta Starter, complete all as specified and as directed. MAKE : BCH/ HAVELLS/ L&T
S&F Automatic Star Delta Starter 20 HP, 415 Volt, 50 Hz with Outgoing and Incoming Cable Connections to the existing Monoblock Pump Set and Testing on Full Load including Taking out/ down Unserviceable Star Delta Starter, complete all as specified and as directed. MAKE : BCH/ HAVELLS/ L&T
S&F Pressure Gauge Diaphram type range 0-7 Kg/Sq Cm including Taking out/ down Unserviceable Pressure Gauge, complete all as specified and as directed.
M&L Preparing Surfaces of Machineries, Pump Sets and Removing Rusts, etc. by Rubbing with Wire Brush and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade) with Spray Painting Machine, complete all as specified and as directed.
REPAIRS & MAINT TO LT EXTERNAL ELECTRIFICATIONS
Dismantling Unserviceable Steel Tubular Pole of any description and any Size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc. including Weathering slightly rounded or Chamfered angle and throating, finishing all exposed faces of Concrete including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & Cement Concrete in Foundation will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of Surfaces, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp 7/3.15 Mild Steel Galvanised Stay Wire, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles, 16mm dia Mild Steel Galvanised Stay Rod and Mild Steel Galvanised Stay Plate all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
REPAIRS & MAINT TO STREET LIGHTS
M&L Taking down Street/Perimeter Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed. NOTE :- (a) Cost of Minor Items/Parts/Spares such as Wiring, Mild Steel Bolts, Nuts & Washers, etc. will deemed to be included in the Quoted Unit Rate. (b) New Parts/Spares (Quantites are Provisional) will be Measured & Paid separately under respective Items as 'Supply only'.
Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30 Watt, complete all as specified and as directed.
Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 45 Watt, complete all as specified and as directed.
S&F LED Street Light Fitting 30 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
S&F Flood Light 50 Watt Luminaire with High Power COB LED as Light Source, Energy Saving, IP-65 Protectd complete with all Accessories, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed
M&L Street Light Fitting Bracket made out from GI Pipe 40mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works including Taking down Unserviceable Street Light Fitting Bracket of any description from any Height, complete all as specified and as directed.
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of Size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable Size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable Size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed. MAKE : HENSEL/ SCHNEIDER/ SINTEX/ UNIVERSAL SWITCH GEARS CONTROL or as approved by GE.
M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter Size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
M&L Taking down existing Unserviceable Garden Light Fitting of any description from 3.00 Metre Pole after disconnecting, Opening Cover and Checking the Light Fitting, Carry out necessary Repairing including Changing of Defetive Parts, Refixing the repaired Garden Light Fitting in Existing Position and Testing, complete all as specified and directed. NOTE :- (a) Cost of Minor Parts/Spares such as Wiring Wires, Mild Steel Bolts, Nuts, Washers, etc. deemed to be included in the Quoted Unit Rate. (b) New Parts/ Spares will be Measured and Paid for seperately under appropriate Items.
S&F LED Post Top Light Fitting 20 Watt, Globe shaped in Frosted Finished, made up of Polycarbonate suitable for LED Lamp (B-22 base) complete with LED Lamp 20 Watt and all Accessories, Providing Electric Connections including Taking down Unserviceable Post Top Light Fitting of any description, complete all as specified and as directed.
S&F LED Post Top Fitting 25 Watt, Energy Saving, Environmental Friendly, Long Life, Asthetically designed with Symmetrical Light Distribution, Spun, Aluminium Landscape Luminare, IP-65 Protection with High Power LED as Light Source including Lamp 25 Watt, Providing necessary Electrical Connection including Taking down Unserviceable Post Top Fitting of any description, complete all as specified and as directed.
M&L PVC Insulated, Multi-stranded, FRLS Copper Conductor Cable of Size 1.0 Sqmm 3 Core, fixing from Fitting to Junction Box including Taking down Unserviceable Cable of any description, complete all as specified and as directed.
M&L Preparing Surfaces of Garden Light Pole 3.00 Metre High including All Accessories of Pole such as GI Bracket, Clamps, etc. and applying One Coat of Aluminium Paint (Superior quality), Painting Bottom Portion of 60 Cm Length 30 Cm Wide 4 No. with Two Coats of Synthetic Enamel Paint (Black and Yellow) in Alternate Strips of Black and White Paint, complete all as specified and as directed.
REPAIRS & MAINT TO LT CABLES
Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Cable Joints, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Supply & Laying/ Fixing XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying/ Fixing XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying/ Fixing XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 16 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 25 Sqmm, 3½/4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 35 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 50 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 70 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Taking down Unserviceable LT Cable, Cross-sectional Area not exc. 35 Sqmm, 3½/4.0 Core of any description, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as Ordered, Relaying/ Re-fixing the Cable after Rectification, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, GI Pipe, etc. will be Measured and Paid separately under relevent Items.
S&F Stright Through Joint with Jointing Kit suitable for 1100 Volt grade UG LT PVC insulated sheathed, armoured, Cable with Aluminium Conductor, Cross-sectional area 16 Sqmm 4.0 Core to 95 Sqmm 3½ Core complete with all Accessories, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches/Ducts for Protection of UG Cables (Below, Above & Around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and Con-solidated(punned) upto 180mm thickness, complete all as specified and as directed NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of Size 250x150x40mm thick, Class LV, Type 1, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 40mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
REPAIRS & MAINT TO LT PANEL BOARDS ACCESSORIES & EARTHING
S&F Change Over Switch 63 Amp rating, On Load, 4 Pole, Side Handle Operated in Sheet Metal Enclouser, 415 Volt, conforming to IS:13947 (Part-I & II) and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F Change Over Switch 100 Amp rating, On Load, 4 Pole, Side Handle Operated in Sheet Metal Enclouser, 415 Volt, conforming to IS:13947 (Part-I & II) and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F Change Over Switch 125 Amp rating, On Load with Bye-pass Switch, 4 Pole, 415 Volt, conforming to IS:13947 (Part-I & II) and Connecting up including Taking down/ out Unserviceable Change Over Switch, complete all as specified and as directed.
S&F MCCB 63 Amp 3 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 100 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 125 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 160 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz and connecting with Incoming & Outgoing Connections including Taking down/out Unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 200 Amp 4 Pole, 25 kA, 415 Volt, 50 Hz, Adjustable Thermal & Fixed Magnetic type and connecting with Incoming & Outgoing Connections including Taking down/out Unserviceable MCCB, complete all as specified and as directed.
M&L Repairs to LT Panel Board, Indoor/ Outdoor Type of any description, Weld-ing of Doors, Replacement of Defective Parts such as Amp Meter, Volt Meter, Frequency Meter, Indicator Lamp, etc., complete all as specified and as directed. NOTE : New Parts such as Amp Meter, Volt Meter, Frequency Meter, Indicator Lamp and Other Spare Parts (Quantitites mentioned Item No. 7.10 to 7.20 here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Amp Meter (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only Volt Meter (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only CT Cast Resin type of Ratio 100/5 Amp Meter (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only Neon Indicator Lamp (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCB 32 Amp, TPN (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCB 40 Amp, TPN (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCB 63 Amp, TPN (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCCB 100 Amp, 4 Pole, 25 kA (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCCB 200 Amp, 4 Pole, 25 kA (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCCB 400 Amp, 4 Pole, 25 kA (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
Supply only MCCB 630 Amp, 4 Pole, 36 kA (as per existing/ as approved) suitable for LT Panel Board of any description, complete all as specified and as directed.
M&L Cleaning, Scraping of Exposed Surfaces of LT Panel Board, Indoor/ Outdoor Type of any description and applying One coat of Synthetic Enamel Paint (Paint & Shade as approved) with Spray Painting Machine including Writing MES No. and Machine No. with Black Paint, Letters 50mm High and 15mm Wide, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earthing with Copper Earth Plate Electrode 600x600x3.15mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Earth Strip of Size 20x3.0mm by means of Bolts, Nuts, Check-nuts and Washers of GI/Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Soil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
REPAIRS & MAINT TO DG SETS
M&L Repairs/Maint & Servicing of DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Item No. 8.02 to 8.11 here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Controler Model No. KGI62.5WS (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA of MAKE : KIRLOSKAR, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE : All Spares and Consumable Items such as Distilled Water, Lube Oil, Grease, Filters and Other Spare Parts (Quantitites mentioned Item No. 8.13 to 8.22 here-in-after are Provisional only) are will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly including Fliter (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Controler Model No. KG934 (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only Oil Filter Assembly including Filter (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 100 KVA of MAKE : ASHOK LEYLAND, complete all as specified and as directed.
M&L Asbestos Rope (as per existing/ as approved) including Taking down/out Unserviceable Asbestos Rope, complete all as specified and as directed.
M&L Battery Terminal of Copper/Brass (as per existing/ as approved) and connected including Taking down/out Unserviceable Battery Terminal, complete all as specified and as directed.
S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out Unserviceable Toggle Switch, complete all as specified and as directed.
M&L Cleaning of Radiator of any capacity after Opening all Nuts, Bolts, etc. by dismounting, Re-mounting after Cleaning with Chemical and Tightening of Nuts, Bolts, etc. including Straightening of Radiator Fins with suitable Tools, complete all as specified and as directed.
M&L Repairing & Cleaning of Diesel Tank with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the same after satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. MAKE : KIRLOSKAR or equivalent Make as approved by GE
Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. MAKE : CASTROL CRB PLUS or equivalent Make as approved by GE
M/s PRABIR ENTERPRISE
M/S S. P. ENTERPRISE
M/s HALDER ENTERPRISE
STANDARD ELECTRIC WINDERS
FREEZCON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .