Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹8.7 L+₹74,610 (9.41%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
24 Mar 2021, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
REPAIR TO PLASTER, CEILING AND FLOORING IN ZONE-B AND ZONE- C AT DEFENCE LAB JODHPUR
2021_MES_426932_1
8419/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DETAILS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹18,000
Yes
7 Jul 2021
1 Mar 2021
26 Mar 2021
1 Mar 2021
24 Mar 2021
10 Mar 2021
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L 15 mm thick , plaster in cement mortar (1:6) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion paint of approved tint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L rendering 10 mm thick plaster in cement mortar (1:3) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L preparation of new plastered surfaces of ceiling and applying two coats of distemper oil emulsion paint of approved tint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L rendering 15 mm thick plaster in cement mortar (1:4) mixed with WPC on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement all as specified & directed by Engineer-in-charge. Note :- WPC will be measured & paid seperately as supply only).
M&L preparation of new plastered surfaces of wall and applying two coats of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-charge.
M&L preparing new or old plastered surfaces of walls and applying two coats of water based paint (exterior emulsion) over a coat of professional exterior wall primer complete all as specified & directed by Engineer-in-charge. (APEX ULTIMA from Asian or equivalent make).
Supply only iliquid water proofing compound all as specified & directed by Engineer-in-charge.
M&L preparation of old plastered surfaces of walls by complete removing existing treatment and applying two coats of distemper oil emulsion paint of approved tint complete all as specified & directed by Engineer-in-charge.
M&L preparation of old plastered surfaces of ceiling by complete removing existing treatment and applying two coats of distemper oil emulsion paint of approved tint complete all as specified & directed by Engineer-in-charge.
M&L preparation of old plastered surfaces of walls by complete removing existing treatment and applying one coat of birla wall care putty( 2 to 3mm thick) to get a uniform smooth surfaces complete all as specified & directed by Engineer-in-charge.
M&L applying two coats of distemper oil emulsion paint over a coat of primer on birla wall care putty surface of walls complete all as specified & directed by Engineer-in-charge.
M&L preparing old plaster/ concrete/stone surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soof, moulds, moss and efflorescent salts and trading oil and greasing spots and applying two coats of cement base paint complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer in charge.
M&L 75 mm thick cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in flooring/ hard standing path in alternate bays area not exceeding 2 Sqm each panel & joints filled with bitumen mastic (1:3) i.e.one part of bitumen and 3 parts of sand, and concrete surface even & smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in floors & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L Light shade vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles exceeding 0.36 Sqm (including 600mmx600mm size) but not exceeding 0.42 Sqm, in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 15mm thick screed bedding in CM 1:4 complete all as directed by Engineer-in-charge.
M&L Light shade vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles exceeding 0.36 Sqm (including 600mmx600mm size) but not exceeding 0.42 Sqm, in skirting/dado(cut to size as required) etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-charge
M&L coloured non skid joit free ceramic tiles 7 to 8mm thick , (square/ rectangular polished, area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 15mm thick screed bedding in CM 1:4 complete all as directed by Engineer-in-charge.
M&L coloured non skid joit free ceramic tiles 7 to 8mm thick , (square/ rectangular polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including 15mm thick screed bedding in CM 1:4 complete all as directed by Engineer-in-charge.
M&L coloured non skid joit free ceramic tiles 7 to 8mm thick , (square/ rectangular polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in in skirting/dado(cut to size as required) etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-charge.
Demolition of wall tiling including cement motor backing coat and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer in charge.
M&L coloured glazed ceramic tiles in vertical surfaces 350x250x7mm /450x350x7mm /450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames not exceeding 1.5 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutters) complete all as specified and directed by Engineer-in-charge.
S&F 30 mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified & directed by Engineer-in-charge.
Taking down shutters of any description area exceeding 1.0 Sqm but not exceeding 2 Sqm each with fittings complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick factory made 2nd class HW glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-charge.
S&F 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required complete all as specified and directed by Engineer-in-charge.
S&F 300mm long mild steel sliding door bolts plate type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as directed by Engineer-in-charge.
S&F 200 mm long, mild steel, barrel tower bolts, stove enamelled black with bright bolt complete all as specified and directed by Engineer-in-charge.
S&F, 150 mm long, mild steel, pressed handles, oval type, stove enamelled black complete all as specified and directed by Engineer-in-charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire stapples complete all as specified & directed by Engineer-in-charge.
S&F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire stapples complete all as specified & directed by Engineer-in-charge.
M&L preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
M&L preparing old wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified & directed by Engineer-in-charge.
S&F solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet re-inforced with M.S. square tube supplying and fixing in opening as per specification and drawing in SSR Part II, complete all as specified and directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20mm width stuck inside with solvent cement for tiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement supplying and fixing in the frame at site all as per specification and drawing in SSR Part-II , complete all as specified and directed by Engineer-in-charge.
S&F, 100mm size, butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin,anodised type B-21 including necessary welding if required complete all as specified & directed by Engineer-in-charge.
S&F 200mm size aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-charge.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-charge.
S&F, rolled mild steel framed work as in doors or gates of angle or other section confirming to Fe 410-W (Gde E-250 quality-A) with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door, fittings and hanging, also fastering and fixing complete all as specified & directed by Engineer-in-charge.
M&L preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint of approved tint over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
M&L preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified & directed by Engineer in charge.
Dismantling/taking down old U/S steel rolling shutters of height upto 8.00 mtr from garages including all accessories as directed by Engr-in charge.
S&F 1.25mm thick Steel Rolling Shutters,without ball bearing,as specified including top cover,anchoring rod,hasp and staple and one shop coat of primer erected in position as indicated,gear operated type with bevel gear box and crank handle including PCC for fixing of holdfast in position & making good to disturbed surface complete all as specified & directed by Engr-in-charge.
Refixing of shutters of any type of size width upto 5.50 mtr & height upto 8.00 mtr from floor level and carrying all repair work at site just like making good for easy moving in flat rails up & down with complete greasing,setting of shutters in freely movable position and painting to shutters to match with existing colour & erected in position as indicated, & making good to disturbed portion of walls complete all as specified & directed by Engr-in-charge.
S&F Safety lever lock mild steel with four levers for rolling shutters
S&F Ball bearing for rolling shutters
Taking down shutters of any description area exceeding 1.0 Sqm but not exceeding 2 Sqm each and refixing the same opening with necessary fittings complete all as specified and directed by Engineer-in-charge.
M&L 0.90 mm thick decorative laminated type 1 of surface finish, colour and pattern as approved,fixed with approved adhesive as per manufacturer's instructions complete as directed by Engineer-in-charge.
S&F Anodised aluminium frame for doors,windows,ventilators with one or more rebated including jointing cleat for fixing etc complete all as specified and directed by Engineer in charge.
S&F Anodised Aluminium door shutters,aluminium section weighting exceeding 1.00 kg/Rm but not exceeding1.80 Kg/m including necessary joint cleats,glazing clips,ruber neoprene packing,handles 2 Nos in each door,hinges,anodised aluminium snap beading screws etc complete all as specified and directed by Engineer-in-charge.
S&F anodized aluminium window and ventilator shutters fixed type without sash bars,aluminium sections weight exceeding 1.0 kg/Rm but not less than 1.60 Kg/Rm including jointing cleats aluminium snap beading/screws complete all as specified and directed by Engineer-in-charge.
S&F anodized aluminium window and ventilator shutters,side hung type without sash bars,aluminium sections weight exceeding 1.0 kg/Rm but not less than 1.60 Kg/Rm including jointing cleats aluminium snap beading/screws,anodised aluminium fittings such as peg stays 150mm long (1 Nos),hinges type B-21 100 mm long(2Nos) suitable handle (1 Nos) complete all as specified and directed by Engineer-in-charge.
S&F Aluminium grill type D or any other type as approved ( weight of grill not less than 2.625Kg/ Sqm without frame) with frame complete all as specified & directed by Engineer-in-charge.
Refixing old existing Anodized Aluminium partition panel /section from one location to another in office premises and fixing on PCC Floor/tiling/wall tiles with necessary screws by drilling in position and making necessary repair to aluminium partition if requied complete all as specified & directed by Engineer-in-charge.Note :- rates are included for glass pane,pre-laminated sheet in aluminium partition should be taken out from frame and refixing in the same opening including necessary jointing cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws,anodised aluminium fittings etc complete all as specified and directed by Engineer in charge.
S&F stainless steel framed work for stairs (square,round hollow sections of any type etc) including stringers trades,landing,balusters,hand rails,cleats,brackets etc including fixing railing in PCC/ kota stone/granite etc with making good to distubed potion etc complete all as specified and directed by Engineer in charge.
S&F,Solar control film 25 micron reflective type (graveware sun control or equivalent) complete all as specified & directed by Engineer-in-charge.
S&F 12 mm thick pre laminated particle board exterior grade both side laminated in panel of partition or any other location complete all as specified & directed by Engineer-in-charge.
S&F 100 mm size,4 lever brass motice lock complete all as specified and directed by Engineer-in-charge.
S&F 140 mm size floor door stopper aluminium alloy body complete all as specified and directed by Engineer-in-charge.
S&F in repairs aluminium(extruded section) door closer hydraulically regulated,designation No 1 universal type,suitable for door shutters of 851 to 1000mm in width & weight between 61 to 80 kg & fixed with stainless steel screw complete all as specified & directed by Engineer-in-charge.
S&F in repairs Gypsum board 12mm thick in ceilling fixed with screw as per manufacturer's instructions, plain/ fixed in Anodized Aluminium snap grid frame work for seamless ceiling comprising of GI parameter channel 0.55 mm thick with two uneaqual glanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c /intrmediate channel 0.9 mm thick having two equal glanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm c/c with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 mtr length) of 0.55 mm thickness having kurled web of 50 mm and flenge of 26 mm each with lips of 10.5 mm fixed to the interediate channel with connecting clips across the intermediate channels at 457 mm centre to centre with Hangers 6 mm dia GI (upto 1200 mm length) adjusing level fixed to roof slab by means of ceiling claet made out of GI flat 40x 3 mm size 60 mm long & applying two coats of plastic emulsion paint over coat of primer(tint as approved by Engineer-in-charge) (Note:- If any minor electricial fittings and fixtures disturbed there-in after be match and fixed as existing.) & including taking down old unservicable ceiling complete all as specified and directed by Engineer-in-charge.
SNEH CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .