Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.8 L+₹1.4 L (4.09%)Rejected-Finance JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L2 | Rejected-Finance L2 |
Tender Value
₹39.9 L
EMD Value
₹79,860
Closing Date
14 Sept 2023, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, installation and commissioning of Air Conditioning system at Matangini Pritilata Auditorium at Womens College, Agartala, Tripura
2023_CEPWD_41547_1
35/B/DNIeT/SE-IV/PWD(RandB)/20
Open Tender
Electrical Works
Works
180 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹79,860
17 Oct 2023
1 Sept 2023
14 Sept 2023
1 Sept 2023
14 Sept 2023
1 Sept 2023
Amount
Providing, Testing & Commissioning of Minimum 8 TR (96000 Btu/h) to maximum 8.5 TR (102000 Btu/h) Ceiling supported Ductable AC unit and the outdoor & indoor unit acting on 3 Phase 380 to 415 V (±) 50Hz & Single Phase 220 to 240 V (±) 50Hz respectively, Machine should be inverter technology and run on 410 refrigerant or equivalent in/c commissioning with vaccumising, Nitrogen pressure testing, first charge of refrigerant, lifting sifting, installation etc. complete as per direction of Engineer -in- charge.
Providing, Testing & Commissioning of Minimum 4 TR (48000 Btu/h)Ceiling supported Ductable AC unit and the outdoor & indoor unit acting on 3 Phase 380 to 415 V (±) 50Hz & Single Phase 220 to 240 V (±) 50Hz respectively, Machine should be and run on 410 refrigerant or equivalent in/c commissioning with vaccumising, Nitrogen pressure testing, first charge of refrigerant, lifting sifting, installation etc. complete as per direction of Engineer -in- charge.
Providing & Installation of Hard Drawn Copper piping complete OEM duly installed with 19 mm/13 mm close cell electrometric nitrile rubber insulation for manufacturer's designed pipe of size as per direction of the Engineer in charge:- 9.52 mm (3/8") OD with 13 mm thick insulation.
15.90 mm (5/8") OD with 13 mm thick insulation.
22.22 mm (7/8") OD with 19 mm thick insulation.
Designing, fabrication & erection of 22 G GI sheet metal Ducting in/c providing necessary flanges, gaskets, bracings and supports complete as per direction of the Engineer in charge.
Supply & fixing of Duct acoustic insulation with 10 mm thick open cell nitrile rubber (Inside) in/c all necessary fitting arrangement ( acoustic insulation should be fitted by corrugation in inside for reducing the sound up to 20 DB) complete as per direction of the Engineer in charge.
Supply & erection of Thermal insulation with minimum 12 mm thick Nitrale complete as per direction of the Engineer in charge.
Supply & erection Canvas connection complete as per direction of the Engineer in charge.
Providing & installation Outdoor structure or Pedestal complete as per direction of the Engineer in charge.
Providing , Fitting & fixing of powder coated extruded aluminium Eyeball Jet 300 mm diffuser Circular/ round shape white colour complete as per direction of the Engineer in charge.
Providing, Fitting & fixing of powder coated extruded aluminium Grill without MS VCD complete as per direction of the Engineer in charge.
Providing & Installation VI Pad for outdoor unit complete as per direction of the Engineer in charge.
Providing & Fitting fixing of Electric Control cable (5 core) suitable for connection between MCB to Outdoor unit / indoor unit etc complete as per direction of the Engineer-in-charge. 5Cx 4.0 sq.mm cu cable.
Cutting hole on the wall of the Auditorium for supply & return duct of AHU unit installed at outside the Auditorium and repair the same holes after completion of the duckting work by bricks, cement plastering, Colouring etc . complete as per direction of the Engineer in charge.
Fabrication & fitting Fixing of MS Structure (by 50 mmx 50mm X 4 mm MS angle) for Enclosure of the AHU which has to be enclosed by 19 mm weather proof, anti Termite Ply wood insulated by 12 mm Nitrale in/c provision of necessary maintenance door with locking arrangement on bottom part of the enclosure and Colouring the same two or more coats etc. complete as per direction of the Engineer in charge.
Providing & fitting Fixing Return duct enclosure/ Module false ceiling by providing Galvanised Iron channel structure & Gypsum Board for Return duct in/c keeping provision of fitting fixing of Diffuser & return Grill etc .complete (necessary scaffolding will be done by the agency in his own cost) as per direction of the Engineer in charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
R.P.ELECTRONICS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_42189.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .