Renovation of Civil and Interior works under deposit work of AHM : Renovation of Civil, Interior, Furnishing, Electrification works and Interior works of the office of the Secretary (Housing), Affordable Housing Mission (AHM) at Urban development and Urbana housing Department, Block No. 14/7, New Sachivalaya, Gandhinagar deposit work of Affordable Housing Mission (AHM).
298166
GUDC/PROJECTS/UDD/RENOVATION WORK
Open
Civil Works - Others
Works
Gandhinagar
3 documents required · 3 mandatory
₹4,248
GUDC Ltd., Gandhinagar
₹79,250
21 Apr 2026
21 Apr 2026
21 Apr 2026
30 Apr 2026
21 Apr 2026
ITEM NO ITEM DESCRIPTION AMOUNT (In Rs.)
22 Electrical Miscellaneous
* TOTAL ELECTRICAL WORK AMOUNT
23 ICT Distribution System For Data And Voice Infra
24 Cable Television Distribution System
* TOTAL ELV WORK AMOUNT
* TOTAL CIVIL + FURNITURE + E&M WORK AMOUNT
Iteam No. Item Description Quantity Unit Amount (in Rs.)
DISMANTLING WORKS
Dismantling of existing masonry work of any type, while preserving the integrity of any existing
brickwork, regardless of thickness, plaster, or wall lining, using the necessary tools, plant, and
scaffolding. The work includes sorting the dismantled material, disposing of unserviceable material
at an approved location, and stacking the serviceable material with all required all lifts and all
1 leads, as directed by the Engineer-in-Charge. 5.00 Cum 577.92
The volume of the existing masonry work shall be measured for payment before dismantling
begins. The method for calculating the volume for payment shall be approved by the Engineer-in-
Dismantling or removal of tiled, paved floors, stone floors, including all required sub-layers
and stones from door jambs, windows, ventilation openings, wall tiles, dado, etc. This includes any
necessary earthwork and backing coat mortar. The work involves disposing of unserviceable
material at an approved location with all necessary lifts and all leads, and stacking serviceable
material, including loading and unloading for all required leads and lifts, as directed by the
Engineer-in-Charge.
The area of the existing flooring/dado shall be measured for payment before the dismantling
begins. The method for calculating the area for payment shall be approved by the Engineer-in-
Dismantling of doors, windows, ventilators, nets, meshes, grills, rolling shutters, Louvers
(fixed/Openable) etc., whether wood or steel or glass, including frames, shutters, architraves,
holdfasts, hood covers, guide channels, and other attachments, as per site conditions. The work
must be carried out without damaging any adjacent structures or elements.
The serviceable material must be stacked with all necessary lifts and all leads, while
unserviceable material must be disposed of at an approved location outside the campus, including
all required leads and all lifts, as directed by the Engineer-in-Charge. Existing hardware fixed to
doors, windows, and ventilators shall be removed from dismantled elements and stacked as
instructed by the Engineer-in-Charge. The Identification of the servicable material shall be
confirmed by the engineer incharge. The dismentle each number of door/window /ventilators etc
shall be measured for payment without considering any wastage. No extra payment to be made
regarding double shutter/ingle shutter/fixed shutter/ transom etc
Chipping, Removing and scraping of old and/ or deteriorated plaster
Chipping, removing, and scraping of old and/or deteriorated plaster of any type and any thickness
from any surface, using methods that avoid damaging existing masonry, plain, or reinforced
cement concrete surfaces to be retained. This includes preventing vibrations to existing and
neighbouring elements. The work involves stacking serviceable material with all necessary lifts
4 and any leads, and disposing of unserviceable material at an approved location outside the 518.00 Sqm 20.55
campus, including all required leads and all lifts, as directed by the Engineer-in-Charge.
(Note: This item does not apply to walls designated for demolition.) The area of the existing plaster
shall be measured for payment before the dismantling work begins.
Dismantling of any type of False ceiling
Dismantling of any type of false ceiling of any size, any shape, any thickness, anly floor,
any material, any level, including framing, accessories, etc. The work involves disposing of
unserviceable material at an approved location with all necessary lifts and all leads, and stacking
serviceable material within site area, including loading and unloading for all required leads and
5 lifts, as directed by the Engineer-in-Charge. The Identification of the servicable material shall be 138.00 Sqm 56.79
confirmed by the engineer incharge.
The area of the existing roofing shall be measured for payment before the dismantling begins. The
method for calculating the area for payment shall be approved by the Engineer-in-Charge.
Dismantling of any type of Partition/wall lining/panelling
Dismantling or removal of any type of Partition/wall lining/panelling of any material, any size, any
shape, any thickness, anly floor, any level, including framing, any type of superficial material, and
other component etc. The work involves disposing of unserviceable material at an approved
location with all necessary lifts and all leads, and stacking serviceable material within site area,
6 including loading and unloading for all required leads and lifts, as directed by the Engineer-in- 11.00 Sqm 83.48
Charge. The Identification of the servicable material shall be confirmed by the engineer incharge.
The single time area of the partition/wall lining/panelling shall be measured for payment before the
dismantling begins.
Removing of existing sanitary work
Removing existing sanitary fixtures and flushing cisterns, including all relevant accessories (WC,
wash basin, urinal, etc.). The work includes stacking useful materials near the site and disposing
7 of unserviceable materials at an approved location outside the campus, with all necessary leads 2.00 Each 425.93
and all lifts, as directed by the Engineer-in-Charge.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Dismantling of existing metalworks at all levels, including dismantling, cutting, and
dismembering all structural elements by any means, as suggested by the Engineer-in-Charge.
This includes earthwork, base concrete, and reinstating the disturbed ground. The work involves
stacking useful materials and disposing of unserviceable materials at an approved location,
8 including all necessary leads and all lifts, as directed by the Engineer-in-Charge. 100.00 Kg. 3.85
The weight of the dismantled steel members shall be measured for payment. The method for
calculating the weight of the steel for payment shall be approved by the Engineer-in-Charge.
Total Carried Over to Summary
MASONRY WORK/PARTITION WORK
1) Masonry work shall be carried out for all floors, all levels, all heights, and all places including
loading, unloading, stacking, transporting, hoisting, and erecting by any means (mechanical or
2) The Contractor shall grout all cavities, and holes/gaps in the masonry with suitable mortar as
suggested by the Engineer-in-charge and making good the required finish at no extra cost.
Providing and laying brick masonry in the superstructure using common burnt clay bricks
conforming to IS 1077-1992, having a compressive strength of not less than 35 kg/sq.cm in
cement mortar 1:5 (1 cement: 5 coarse sand) in any shape, any thickness, including finishing,
9 curing, scaffolding racking out the joints/ flush jointing etc. complete for all levels, all floors, all 5.00 Cum 4,660.83
heights, as per the issued drawings and as directed by the Engineer-in-charge.
Providing and laying half brick masonry in the superstructure using common burnt clay building
bricks, having a compressive strength of not less than 35 Kg/cm2 in cement mortar 1:4 (1-
Cement: 4 -fine sand) in any shape, any thickness, including finishing, curing, scaffolding racking
10 out the joints/ flush jointing, etc. complete for all levels, all floors, all heights as per the issued 5.00 Sqm 704.70
drawings and as directed by the Engineer-in-charge.
Gypsum Dry wall system
Providing and fixing 2 hr fire rated 122mm thick double layered drywall partition system of
approved make for height up to 4.50 mt which includes (on both faces/ elevations) inner layer of
tapered edge minimum 12.5mm thick Fire Resistant Gypsum Board having density minimum
kg/m3 (conforming to IS 2095 Part 1: 2011/ EN520::2004, TYPE-F/ ASTM C1396, TYPE X) and
outer layer of tapered edge 12.5mm thick calcium sulphate dihydrate encased in high gsm paper
liners with glass fibbers and other additives for enhanced the fire, acoustics and impact
performance, third party EPD Verified as per ISO 14025, having minimum density 900 kg/m3, with
maximum allowable point load on single board 25 kg to 30kg without any ply backing, complies
with BS EN 520:2004 – Type A, F, D, R, I, Thermal Conductivity: 0.24 w/mºK, Thermal resistance:
Framing system -
11 GI framing system consists of Close stud/ C stud of size approximately 70x34x36x0.5mm 27.00 Sqm 3,390.42
confirming to IS 513 having Y/S-minimum 230 Mpa, and Finish - AZ150 (IS 15961). The stud shall
be placed at 600mm c/c in 72x32x32x0.5mm (approx.) floor channel and 72X32x32x0.5 mm
ceiling channel. The floor & Ceiling channel is anchored to the floor & ceiling using zinc coated
Rawl plug of size Ø8x45mm and having Pull out Load -7.5 kN/ anchor fasteners of required
capacity as per the manufacturer's specification at 600mm c/c. Floor channel to be wrapped with
70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance
performance. A noggin channel of 70x40x0.5mm has to be provided at the horizontal joints of the
two boards and the top of the board in case the top is not going up to the ceiling channel.
Gypsum boards shall be fixed with drywall screws of 25mm/ 35mm at minimum spacing of 300mm
at centre and 150mm at periphery. Boards shall be jointed and finished so as to have a flush look
which includes filling and finishing with Jointing compound, Joint Paper tape, angle beads at
corners. The junction of the partition with masonry/ RCC & all penetration through the partition has
to be treated with fire and acoustic sealant of approved make.
In case surface/member is not available abutting the door system for fixing, contractor shall design
and propose, a sub-system/ MS frame for fixing arrangement as per manufacturer's
recommendation.
Contractor shall prepare shop drawing based on concept drawing including fixing arrangement,
services and prepare mock-up of required area. As per approved shop drawing and mock-up,
contractor shall start the work. Contractor shall furnish certification of entire system for STC
and 120 minutes Fire rating.
Dry wall system shall be fixed on any type of surface i.e. masonry, RCC, dry wall system, metal
work etc) with required capacity of anchorage as per manufacturer's specification. Stability of door
and partition system shall be responsibility of contractor.
Contractor shall provide fixing arrangement for all elements, which to be fixed in dry wall system.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
All frame members shall be connected to each other by using metal screws. 50mm Rock wool slab
of density 24kg/m³ shall be placed in a metal framework. A Glass wool holding clip should be used
to hold the Glass wool slab in its position.
The rate shall be included for the cost of making openings for light fittings, switchboard, any other
services cut-outs made with a frame of perimeter member suitably fixed, etc complete for all levels
and all heights and as directed by the Engineer in Charge but excluding the cost of painting work.
All Opening cut outs & periphery shall be treated with Fire & acoustical sealant. The contractor
shall be cut the first layer of the gypsum board for the provision of skirting and, an additional board
shall be provided and the top layer to be cut properly as per manufacturer's specification. At the
location of the door frame in the drywall system, the wooden member shall be fixed to the required
size and as per the manufacturer's specification. Horizontal framing members shall be provided as
per architectural requirements and as suggested by the Engineer in charge.
Out to out area of drywall elevation on one side only shall be measured for payment after
deducting for openings for doors/windows and service cut-outs of size more than 0.36 sqm etc,
complete for all floors, all heights. Any additional members, support members, fasteners, fixing
details, etc required in dry wall system shall be designed and provided by contractor and approved
by the Engineer-in-charge, shall also be included in the rate of this item and nothing extra shall be
payable for the same.
Total Carried Over to Summary
PLASTER AND WATERPROOFING WORK
10 mm thick Cement mortar plaster
Providing and applying an average 10 mm thick single coat cement plaster and finishing with a
trowel, on the ceiling, side, and soffit of beam and stair, etc in cement mortar 1:3 (1 cement :
coarse sand), in any shape, at all floors, all heights with necessary scaffolding, curing, application
of bonding agent/making grooves, forming pattas, application of bonding agent/ hacking RCC
surface properly, etc. complete as directed by the Engineer-in-charge.
12 - 15 mm thick plaster - cement mortar
Providing and applying 12 to 15 mm thick plaster (smooth or wire-finished plaster) of cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a trowel on any type of surface. GI hexagonal
chicken mesh of size 20 mm x 20 mm of 22 gauge and minimum 200 mm wide at RCC & masonry
junctions or between different materials and 145 GSM of minimum 150mm wide fiberglass mesh
13 with alkali resistant coating shall be fixed at chasing areas of plumbing and electrical works, at 324.00 Sqm 308.78
corners and door and window joints as per manufacturer's specifications with GI nails, hacking of
concrete/application of bonding agent, finishing, curing, making grooves, forming pattas,
scaffolding in any shape for all floors, all levels, all heights, etc. complete as directed by the
Engineer-in-charge.
Waterproofing for Toilet, Wet area, balconies & Misc. areas
Providing and applying Two-part acrylic polymer modified cementitious elastomeric waterproof
coating of minimum 1.5mm thickness DFT having minimum 1 N/mm2 tensile strength, and shall
cover 2.2 kg/sqm per mm of thickness. The coating shall have an elongation of a minimum of 80%
when tested as per ASTM D 412 resisting 5 bars hydrostatic pressure as per DIN 1048 and having
crack bridging ability of up to 2mm. Thorough surface preparation by mechanical means to level
and plain the surface of walls and floors of the toilet areas. All cracks and crevices shall be filled
and made good to receive waterproofing coating treatment The coating shall cover all the floor
area of the wet area (toilet) and shall also be applied over the vertical walls for a minimum 300mm
height above the floor in two or more coats to achieve required thickness. The periphery of the
toilet floor shall be additionally reinforced with an extra third coat of the coating with a fiber band
(glass fiber mesh of minimum 80 gsm) sandwiched between the first and the second coat, which
shall also done around protrusions (pipes) meant for plumbing purpose. The last coat (second/
third coat) when wet, shall be sprinkled with clean and washed sand, to facilitate the floor screed
Pipes being fixed for plumbing shall be fixed in holes that are mechanically core cut, more than the
diameter of the pipes. Pipes shall be fixed by grouting the annular space with non-shrink
cementitious grout of proprietary make. Before grouting, the pipes shall be wrapped with a two-
way self-adhesive tape at least 50mm wide and then grouted to fill in the grout, ensuring total
watertight plumbing fittings. The contractor shall submit a methodology statement with all details in
illustrative sketch form and get approval from the Engineer-in-charge. Application shall be carried
out by the approved applicator of manufacture and as per recommended by the manufacturer. The
actual applied area on the floor & wall shall be measured for payment. Cost includes all material
(for surface preparation, coating, and hole packing), labour, T&P, and wastage involved as
mentioned in the item.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
M25 Garede concrete screed for leveling
Supplying and laying M25 grade vibrated concrete screed in proper slope and gradient including
saw cutting (approx. 6mm W x 30mm D) at 3m x 4m panels or less size, making angle fillet of
50mm x 50mm at the corners using M25 grade concrete and filling the grooves with PU sealant
(minimum 20 mm depth over PE backer rod). If Screed concrete shall be laid over on existing
concrete surface, a bonding agent shall be applied before laying of concrete. Cost includes all
material, labour, T&P, and wastage involved as mentioned in the item. Reinforcement, if required,
shall be paid under relevant agreement items.
Total Carried Over to Summary
DOOR WINDOWS WORK
1. Only First class wood shall be used for any kind of woodwork. All wood (kiln seasoned and
termite treated) and wood base material shall be treated with anti-termite treatment as per relevant
IS before use and after installation. The guarantee shall be furnished for 10 years in the
prescribed format as directed by EIC.
2. Plywood (BWP grade IS – 710), laminate or other composite wood-based products shall be free
of urea formaldehyde.
3. All veneer, and wood shall be FSC (Forest Stewardship Council) & Green Guard Certified.
4. All loose samples of materials shall be approved by the Engineer in charge.
5. All manufactured products shall conform to Green building norms.
6. All adhesives and sealants shall be with low VOC and lead-free with acceptable VOC content
as per GRIHA requirements.
7. The contractor shall prepare a shop drawing based on the intent/ concept drawing and get
approval from the Engineer-in-Charge. The contractor shall prepare mock-up doors, windows, and
other elements with all required hardware and approved by the Engineer-in-Charge before
execution of work. Work shall be carried out as per the final approved shop drawing and approved
mock-up. The contractor shall be responsible against stability, safety, leakage, etc all complete.
Testing work shall be carried out by the Contractor as suggested by the Engineer in charge. (If
8. All types of locks shall be with computerized 3 No. keys (SS 304/ brass) and master keys (if
mentioned in the nomenclature of the item). The grouping of master keys shall be as suggested by
the Engineer-in-Charge. Nothing extra shall be payable for the master key provision.
9. The contractor shall provide test certification for all fire-rated items.
10. Contractor shall make provision for access control system and other mechanical/ automation
devices, coordinate with other services work, and make goods, etc complete.
11. All Doors, windows, and other elements shall be fabricated and finished at the factory/
workshop, and only fixing and final finishing shall be executed at the site unless otherwise
approved by the Engineer-in-charge.
12. Door, window, and other elements work shall be carried out for all floors, all levels, all heights,
and all places including loading, unloading, stacking, transporting, hoisting, and erecting by any
means (mechanical or manual).
Teak wood Frames for doors/windows etc.
Providing and fixing frames of doors, windows, transom, louvers and ventilators, jambs-sills, using
best quality kiln seasoned, termite treated first-class teak wood and fixed in position with hold fast
lugs or with dash fasteners with required dia & length of approved make, etc. for all levels, all floor,
all height, etc as per drawing and as directed by an engineer in charge.
The rate shall be inclusive of all types of consumables, accessories, fasteners, and any type of
corner treatment (i.e. chamfering, pencil corner, bevelling, moulding, etc.). Polishing, hardware,
and carving work shall be paid in relevant tender items.
The contractor shall get the approval for the loose sample of first-class teak wood along with its
source location from the Engineer in charge before execution.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Providing and fixing aluminium work for fixed partition, louvers, frame for door and window
(sliding, openable, side hung, top hung, fixed etc.), casement window, aluminium partition, fixed
window etc. with extruded built up, standard tubular sections/ appropriate Z sections, sheet, flat
bar and other sections of approved make conforming to IS:733 and IS:1285, having polyester
powder coating (minimum thickness of polyester powder coating 50 micron), fixing with SS
dash fasteners of required dia and size, including necessary filling up the gaps at all around and
both side, i.e. at top, bottom and sides; with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever
required including cleat angle, pressure cleat, crimping angle, aluminium snap beading for glazing/
17 panelling, SS 304 screws etc. all complete as per approved shop drawings and the directions of 712.00 Kg. 325.17
Engineer-in-charge. Rate shall be inclusive of any type of aluminium section , cutting, fabrication,
erection and fixing to thr best workmanship manner, PVC shims minimum 5mm thick, with backer
rod and silicone sealant (both side), dash fastener, etc complete. Only glazing and SS hardware
shall be paid for separately.
Contractor shall prepare shop drawing based on architectural drawing and get approval from
Engineer-in-charge before execution. Contractor shall also prepare mockup with all required
hardware as suggested and approved by Engineer-in-charge.
Providing and fixing door shutter made out of factory-made and pressed laminated/ veneer
finish 40mm thick flush door shutter excluding the thickness of veneer/ laminate, made of ISI
marked non-decorative type flush door shutters conforming to IS:2202 (Part I), the core of block
board construction with the frame of 1st class hardwood, pine filler and well matched commercial
ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
having laminates/ veneer of approved make, shade, finish (which paid separately) as approved by
Engineer-in-charge on both faces of shutter fixed with phenol formaldehyde synthetic resin type
adhesive conforming to IS 848 including providing and fixing 6mm thick peripheral external lipping
made out of first class teak wood, on all edges of door shutter with specified polishing on all
18 exposed faces of lipping including fixing shutters etc complete for all levels, all floors, all heights as 15.00 Sqm 2,660.39
per drawings and as directed by Engineer-in-charge. The door shall be with a suitable acoustic
peripheral door seal and drope down door seal of approved make is included in this item.
The rate shall be inclusive of flush door shutter, teak wood lipping with PU polish, necessary
consumables, accessories, etc but excluding the cost of veneer/ laminates, all required hardware,
and polishing on veneer, etc complete for all heights as per drawing, design & direction by
Engineer-in-charge. The out-to-out area (one side) of the Flush door shutter shall be measured for
4 mm thick decorative veneer
Providing and fixing 4 mm thick decorative veneer (factory pressed with door shutter or plywood
for interior work) conforming to IS: 1328 (type-1) having the top layer of minimum 0.3 mm slice
thickness decorative veneer and base layer of approximate 3.5 mm thick BWP Gurjan Ply of
approved make, shade and pattern/ texture, for plain lining/ cladding/ ceiling work, on flush door
19 shutter, pelmet or any interior work in any design, any pattern, any shape, etc with necessary 23.00 Sqm 1,253.36
screws, adhesive including priming coat on the unexposed surface. The veneer shall be fixed on
the ply with or without groove as per drawing. The actual installed area of the veneer shall be
measured for payment.
Providing and fixing glass in the door, window, ventilation, fixed glazing, partitions, etc. for all
levels, all floors, all heights with EPDM rubber/ neoprene gasket, etc. complete as per drawings
and directions of engineer-in-charge. (Cost of beading shall be paid in basic item). Glass shall be
of any shade, any size, any shape as per approved make, sample, and drawing and confirm to
20 IS:2835 or IS:2553. The sample shall be approved before the execution of the work. The installed 5.00 Sqm 1,552.52
area shall be measured for payment without considering any wastage. In case of glass is required
to fixed using patch fitting clamps & screwes/anchor of approved make, It is included in this item.
b) With clear toughened glass panes of 8.0 mm thickness
a) With clear toughened glass panes of 12.0 mm thickness
Providing and fixing in position PVC frosted glass film of 100 to 130-micron (including adhesive)
thickness, of an approved make (of any pattern, shade, and type) on any type of glass for
internal/external use as per manufacturer's specification and as per issued drawing etc complete
22 for all levels, all floors, and all heights. The film shall be pasted on the glass without any air 10.00 Sqm 469.45
bubbles. The finished frosted film area on the glass shall be measured for payment without
wastage. Warranty shall be for a minimum of 05 years for material and installation of the film.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Cam action door closer
Providing and fixing cam action door closer of approved make with a minimum one-year guarantee
and approved finish for all levels, all floors, and all heights with controlled adjustable closing and
latching speed, with hold open feature and power-adjustable with track arm with screws to hinged
door for specified door width. All adjustment screws face fixed. The rate shall be inclusive of fixing
using the template as per the manufacturer’s specification & maintaining it in good working
23 condition. The door closer shall conform to EN 1154 standard. Selection of door closer shall be as 5.00 No. 10,214.94
per size and weight of the door, as per manufacturer's recommendation and as directed by the
Engineer-in-charge. The contractor shall arrange loose Samples for approval from the Engineer-in-
Charge before mass execution.
a) concealed door closer conforming to EN 2-4 for any type of the door, as per the manufacturer's
specifications, and/or compatible with the shutter weight.
SS 304 Butt hinges
Providing and fixing SS 304 butt hinges in matt stainless steel finish of the specified size of
approved make for all levels, all floors, and all heights of any type of door, with required SS
24 screws, etc. complete. The rate shall be inclusive of fixing as per manufacturer’s specification & 24.00 No. 299.47
maintaining it in good working condition. The contractor shall arrange loose Samples for approval
from the Engineer-in-Charge before mass execution.
b) 100 x 75 x 3 mm - With ball bearing
Mortise Deadlock for single/ double door shutter
Providing and fixing a set of mortise deadlock (without latch) for single/ double shutter door,
including strike plate SS 304, and prepared for 60/70 mm length of standard euro profile pin
cylinder as per DIN 18251-1, grade 2 of approved make with both side key/ one side key one side
knob/ one side key one side slot operation with pair of SS 304 escutcheons (keyhole plate) in matt/
25 satin finish as per approved shape for wooden/ aluminium doors with necessary SS 304 screws,
etc complete as per drawing and sample approved by Engineer-in-charge.
The rate shall be for all heights, all floors, and all places. The lock shall be with 3 number
computerized keys. The contractor shall arrange loose samples for approval from the Engineer-in-
Charge before mass execution.
Mortise sash lock with lever handle
Providing and fixing a set of mortise sash lock with SS 304 pair of Mortise lever handle with a cap
of any shape, and size in matt/ satin finish for single/ double shutter doors, including strike plate
SS 304, and prepared for 60/70 mm length of standard euro profile pin cylinder as per DIN 18251-
1, grade 2 of approved make with both side key/ one side key one side knob/ one side key one
side slot operation with pair of SS 304 escutcheons (keyhole plate) in matt/ satin finish as per
26 approved shape for wooden/ aluminium doors with necessary SS 304 screws, etc complete as per 2.00 Set 1,837.95
drawing and sample approved by Engineer-in-charge.
The rate shall be for all heights, all floors, and all places. The lock shall be with 3 number
computerized keys. The contractor shall arrange loose Samples for approval from the Engineer-in-
charge before mass execution.
SS 304 Grade Push-Pull handle (for any type of shuter i.e. glass/Flushdoor/aluminium
Providing and fixing SS 304 grade push-pull pair of handle in matt finish of the specified size,
specified shape i.e. H-shape/ D-shape/ offset shape (dent free at bending point)/ or reference
image for any type of the door, etc. of approved make for all levels, all floors, and all heights with
required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The
rate shall be inclusive of fixing as per manufacturer’s specification and maintaining it in good
working condition. The contractor shall arrange loose Samples for approval from the engineer-in
charge before mass execution. Overall length of handle shall be considered.
a) 300 mm long as per reference image x 1mm (thickness of pipe)
28 c) 600 mm long as per reference image x 1mm (thickness of pipe) 3.00 Pair 2,703.37
SS 304 Tower bolt
Providing and fixing SS 304 grade tower bolts of the specified size, and specified shape (with or
without flap) in matt/ satin finish for the door, window, transom, etc. of approved make for all
levels, all floors, and all heights of any type of door, with required SS 304 screws and accessories
of the required size for fixing, etc. complete. The rate shall be inclusive of fixing as per
manufacturer’s specification and maintaining it in good working condition. The contractor shall
arrange loose Samples for approval from the Engineer-in-Charge before mass execution.
C) 450 mm x 10 mm rod size
Iteam No. Item Description Quantity Unit Amount (in Rs.)
SS 304 door stopper
Providing and fixing SS 304 door stopper with or without magnet, lever type, shutter mounted/ wall
mounted/ floor mounted in matt/ satin finish as per approved design, approved make and
approved shape of for the door, window, transom, etc. for all levels, all floors, and all heights of
any type of door, with required SS 304 screws and accessories of the required size for fixing, etc.
complete. The rate shall be inclusive of fixing as per manufacturer’s specification and maintaining
it in good working condition. The contractor shall arrange loose Samples for approval from the
Engineer-in-Charge before mass execution.
Shaft door lock
Providing and fixing shaft door lock with key (Alen Key lock) with Escutcheons (keyhole plate),
strike plate, locking sleeve, etc in stainless steel matt finish of approved make in any approved
shape/size for any type of doors with necessary SS 304 screws, etc complete as per drawing and
sample approved by Engineer-in-charge. The rate shall be for all heights, all floors, and all places.
The contractor shall arrange loose Samples for approval from the Engineer-in-Charge before
mass execution.
Providing and fixing SS 304 grade handle in matt finish of specified size, specified shape for door,
window, etc. of an approved make for all levels, all floors, and all heights for any type of door, with
required SS 304 screws, accessories, and pin of the required size for fixing, etc. complete. The
rate shall be inclusive of fixing as per the manufacturer’s specifications and maintaining it in good
32 working condition. The Contractor shall arrange loose samples for approval from the Engineer-in- 1.00 No. 405.16
Charge before mass execution.
a) Flush handle/ concealed handle - 150 mm long Flush Handle - Concealed handle recessed in
the depth of the shutter with pull arrangement for shutter, as per approved design and shape
Aluminum powder coated Multi point lock with (without locking arrangement)
Providing and fixing Aluminum powder coated multi point lock with mortise handle/ inbuilt flush
handle (without locking arrangement) in approved finish, color, and shade of the required size and
capacity of approved make for internal/external shutter as per approved sample with necessary
SS 304 screws, handle, connector, extension, nib, nib holder, counter plate, fork, pawl, polyamide
strip, connection pin, rod terminal, locking point, striker and corner transmission etc. complete for
33 all levels, all floors, and all heights as directed by Engineer-in-charge. 26.00 No. 2,650.19
The rate shall be inclusive of fixing as per manufacturer’s specification & maintaining it in good
working condition. The contractor shall arrange loose Samples for approval from the Engineer-in-
Charge before mass execution.
b) For aluminum hinged door and window shutter (top hung or side hung)
Providing and fixing adjustable/ fixed Teflon roller bearing set with reinforced nylon casing of
approved make (twin or single wheel according to weight and size) for sliding window/door as
34 per drawing etc. complete for all floor, all height, all level as per approved sample and as directed 50.00 No. 211.04
by engineer in charge.
Total Carried Over to Summary
FLOORING AND DADO/CLADDING WORKS
1) All natural stones shall be free from cracks, lines, stains, and white spots of efflorescence, and
even in shade for all kinds of stonework.
2) All natural stones shall be selected and sorted for uniform colour, figure, and thickness and
approved by Engineer-in-charge prior to procurement.
3) All natural stones shall be from the same lot and/ or source (stone quarry) for the same kind of
work to avoid shade variation and as approved by the Engineer-in-charge.
4) All types of loose and laid samples of flooring shall be approved by the Engineer-in-charge.
5) The contractor shall apply approved Stone Impregnation primer/ sealer coat on both sides and
all edges (after cutting and finishing the stone as per size) of stones in a minimum of two coats as
per the manufacturer's specification and as directed by the Engineer-in-charge. No extra shall be
paid for the same.
6) Contractor shall co-ordinate and execute for all services in flooring and wall lining/ cladding
work i.e. making openings/ cut-outs for any services (i.e. elevator operating panel in lift wall
cladding, raceway in flooring, junction box, etc), and making good as per the satisfaction of
Engineer-in-charge.
7) All stones shall be cut to size with the help of with water jet cutting/laser cutting/ CNC machine
according to the design and shape for best workmanship etc according to the design as per the
approved shop drawing.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
8) All adhesives and sealants shall be compatible with material as per IS 15477 and as per the
manufacturer's specification and with low VOC and lead-free with acceptable VOC content as per
Green building requirements.
9) Finished floor surfaces shall be protected with a 12mm thick POP sheet over an LDPE sheet up
till handling over the project. The tread of the stair shall be protected with a metal/ plywood angle
to avoid damage to the edges of the tread. POP shall not directly (or with the use of paper) apply
10) Screed below flooring/ base mortar thickness shall be as per drawing. In case of any type of
stone/ tile shall be fixed with adhesive and the total thickness of base mortar/ screed shall be paid
in relevant tender items.
11) All stone shall be factory cut and factory finished. Polish or any type of texture finish on any
stone shall be as per the satisfaction of the Engineer in charge.
12) Flooring and wall cladding/ lining work shall be carried out for all floors, all levels, all heights,
and all places.
15) Rate shall be inclusive of all types of wastage of all material.
Vitrified tiles - For flooring - fixing with cement mortar
Providing and laying Vitrified tiles (superior quality tiles) with water absorption less than 0.08% and
conforming to IS: 15622, of specified sizes, specified thickness, approved make, any finish (anti
skid/ satin/ polished etc), any shade, any color, and any shape for flooring in required design and
patterns as per the drawings, laid over average bedding 40 mm thick cement mortar 1:4 (1
cement: 4 coarse sand), jointed with a groove or without groove with grey/white cement slurry
mixed with a pigment to match the shade of the tiles, including finishing, cleaning, protection,
scaffolding, wastage, etc. all complete for all levels, all floor, all height, as specified and as
directed by the Engineer-in-Charge.
Rate shall be inclusive of vitrified tile (as per approved sample), fixed with cement mortar bedding,
cement slurry, matching pigment, all labour etc complete but excluding filling with epoxy grout (if
required) and additional cement mortar bedding/ concrete screed bedding as per drawing which
shall be payable under relevant Tender item. The contractor shall arrange loose Samples for
approval from the Engineer-in-Charge before mass execution.
The actual laid area of the vitrified tiles shall be measured for payment without considering any
a) With full body, homogeneous, vitrified tile of size 600 x 600 mm x minimum 9mm thick
Vitrified tiles - For dado/ riser/ skirting fixing with adhesive
Providing and laying Vitrified tiles of specified sizes, with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, shade and finish (matt/ satin/ polished etc) in wall tile/
dado, riser of steps, and pillars laid in any pattern over any type of levelled surface, in any pattern
with suitable cement based high polymer modified quick set tile adhesive (water based)
conforming to IS: 15477of approved make and jointed with groove or without groove with cement
slurry mixed with pigment to match the shade of the tiles, including providing 6 to 10mm wide
36 groove between wall tiles and plaster edge treatment, rubbing, curing, finishing, cleaning, 29.00 Sqm 1,174.68
protection, scaffolding and wastage etc. all complete as specified and as directed by Engineer-in-
Charge. Length of tiles for dado shall be as per design to match the joint and pattern. Shade of
dado must be match with flooring stone.
Rate shall be inclusive of vitrified tile (as per approved sample), adhesive for fixing, cement slurry,
matching pigment, all labour etc complete but excluding filling with epoxy grout which shall be
payable under relevant item.
a) With full body, homogeneous, vitrified tile of size 600 x 600 mm x minimum 9mm thick
Grouting the joints of flooring/ wall tiles/ stone
Extra for Providing and Grouting the joints of flooring/ wall tiles/ stone as specified having joints of
up to 5 mm width in total thickness, using epoxy grout of approved make and shade including PVC
37 spacer, filling/ grouting, protecting tile, abro-tap and finishing complete as per direction of Engineer- 62.00 Sqm 190.84
a) Tiles/ stone of any size
Additional Floor bedding with Cement mortar :
Providing and laying cement mortar 1:4 (1 cement : 4 coarse sand) for additional thickness below
flooring item required for gradient and as per drawing and as directed by engineer in charge
38 including spreading as per gradient, levelling, finishing, curing etc complete as directed by 13.00 Cum 3,991.67
Engineer in charge. Actual laid volume for floor bedding shall be measured for payment without
considering any wastage.
Engineered Wooden flooring and skirting
Providing and fixing 3 layered 12 to 15mm thick Engineer wooden flooring and skirting of approved
type, any shade/ wood species and of approved make, in required pattern and as per
manufacture’s specification confirming to British Standards BS EN 13489. Top layer of plank shall
be made of minimum 3.0 mm natural wood/ veneer of any shade, finish, pattern and texture.
Surface of top layer shall be pre finished with several layer of UV hardened Acrylic lacquer, which
39 shall be free from urea formaldehyde and solvents. Flooring plank shall be interlocked using lock 113.00 Sqm 6,991.37
and fold system in a glue less floating manner. Engineered wood planks shall be a composition of
layers of Pine wood with direction of each layer oriented at right angle to the adjacent layer of
natural strain in lacquer and non bevelled/ bevelled in length and width as specified. Wooden
flooring shall be FSC (Forest Stewardship Council) & Green guard certified.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Rate shall be inclusive of min 2mm thick underlay sheet as sound barrier and/ or vapor barrier
(combination of PE film and extruded foam) and all the accessories like edge strip, joining strip,
quarter strip, moulding strip, end strip, corner strip, skirting, threshold etc. required as per design.
Uniform gaps shall be left on all sides to allow expansion and contraction of material. The gaps are
covered with the help of accessories etc. finished in all respects as per the manufacturers
specifications.
Rate shall be inclusive of making any cut-out for services, floor matching cover over cut outs etc.
complete. The contractor shall get approval of sample and pattern from Engineer in charge before
execution. Area of flooring and skirting including accessories (without considering any wastage)
shall be measured for payment.
18 mm thick granite vanity/washbasin counters and facias:
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and pre-polished,
machine cut granite of any size, any shape, any shade, for vanity/ wash basin counters and
fascias, and similar locations, of required size, approved shade, colour and texture, laid over
mm thick cement mortar 1:2 (1 cement : 2 coarse sand) base, joints treated with white cement,
mixed with a matching pigment, epoxy touch ups, including making all holes & cutouts for SS sink,
40 wash basin, piller tap/ bib cocks, rubbing, curing, rounding edges, champhering and polishing to 2.00 Sqm 1,889.10
edges, to give a high gloss finish etc., complete, at all levels, as directed by the Engineer-in-
Charge. The plan area of the counter and the elevation area of the facia shall be measured for
If required, metal framing/supports shall be paid in relevant Tender items..
Total Carried Over to Summary
FALSE CEILING WORK
Notes for False ceiling work
1. Points to be taken care of by contractor before selecting a manufacturer from approved
• Board/ tiles/ panel, grid system, suspension system and all accessories shall be from a single
vendor and from the same make unless otherwise approved by Engineer-in-charge.
2. Points to be taken care of by contractor before installation
• Contractor shall corelate all services drawings from different installers and prepare a clash free
shop drawing as per architectural drawings for RCP, with all services integration vis a vis HVAC,
FFTG, PLUMBING, ELE, ELV & any other services planned and part of design.
• The methodology statement for execution of all services coordinated with ceiling execution shall
be submitted by Contractor for approval of Engineer-in-charge before commencing execution
• Quality check and sequence of execution along with relevant documentation to be ensured by
the site project team for inspection and quality checks.
• Installation to be carried out by an approved and certified installer of manufacturer. Contractor to
submit manufacturer approved certificate of installer to Engineer-in-charge before commencing
3. Points to be taken care of during installation
• False ceiling work to be strictly supervised for alignment, line & level and overall quality of
installation and contractor to strictly follow approved methodology statement.
• False ceiling suspension work shall be strictly from mother slab or secondary support installed
for false ceiling and not from any other services suspension members.
• Trap door to be fixed in line & level with false ceiling, with separate suspension system from
mother slab, not with false ceiling member. Groves around trap doors should be uniform on all
• All service equipment & light fixtures, curtains etc to be fixed with a separate suspension system
from mother slab, not on false ceiling tile or false ceiling member.
• In gypsum ceiling, contractor shall provide perimeter channel at periphery of all services cutout
for strengthening the system. All cutout in board shall be finished with tape, angle skimming coat
etc as per manufacturer's specification.
• If required, additional supports to be provided for fixing the false ceiling (in case of special shape,
more height etc).
Iteam No. Item Description Quantity Unit Amount (in Rs.)
• In case the height of suspension system is more than recommended by manufacturer, separate
MS work to be provided from mother slab and false ceiling to be suspended from MS work. Design
and shop drawing for MS fabrication work and connections with structure members shall be
submitted by contractor for approval by Engineer-in-charge. MS frame work to be designed to
accommodate other services if required to be submitted on the same frame. Such MS frame work
shall be paid under relevant tender item.
• Sequence of execution of different services to be aligned with RCP to avoid any rework.
• Movement joints/ groove to be provided in board or grid ceiling system in large span area.
4. Points to be taken care of post execution
• Warranty for false ceiling system to be provided by installer & manufacturer to ensure that work
is completed as per specification (material and workmanship) and methodology statement.
• Completion certificate to be provided by installer & to be signed and verified by manufacturer
with respect to tender specifications and approved shop drawing.
• All test reports are to be submitted by the contractor for performance.
5. General Notes
• Contractor to quote the rate considering all points mentioned in the specifications.
Gypsum False ceiling:
Providing and fixing false ceiling at all height including providing and fixing of frame work made of
special sections, power pressed from M.S. sheets and galvanized with zinc coating of 150 gms/
sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x
mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the
ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed
to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and
other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of
80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,
shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made
out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels
0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed
to wall/partition with the help of raw plugs at 450 mm centre, with 25mm long dry wall screws @
230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the
help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a
flush finish of tapered and square edges of the board with recommended jointing compound,
jointing tapes, finishing with jointing compound in 3 layers covering up to 150 mm on both sides of
joint and two coats of primer suitable for board, all as per manufacturer's specification.
In False ceiling, drop-down patta (vertical) more than height/ width of 300 mm shall be measured
and paid. The rate shall also include the cost of making openings for light fittings, grills, diffusers,
and cut-outs made with a frame of perimeter channels suitably fixed, all complete as per drawings,
specifications, and direction of the Engineer in Charge but excluding the cost of putty and painting.
Installation shall be carried out by an approved installer and the material of the suspension system
shall be as per manufacturer specifications.
The contractor shall prepare a shop drawing with coordination of all services and opening/ excess.
Sample, shop drawing, and mock-up shall be approved by the Engineer in charge. The actual
41 installed area in the plan and area for vertical drop down more than height/ width of 300 mm shall 101.00 Sqm 1,133.17
be measured for payment without considering any wastage and without deductions of area for
lights, diffusers, columns, etc. Nothing extra shall be paid for making provisions for lights,
diffusers, AC grills, fire alarm systems, sprinkler systems, and other such fittings/ services in false
ceiling. Work shall be carried out as per the approved sample, Mock-up, and shop drawing
including all material and labour.
b) 12.5 mm thick Fire resistant Glass Reinforced Gypsum (GRG) Boards (Confirming to BS476)
complying to IS: 2095 :
Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 %
perforated area with perforation size and pattern as approved by the Engineer-in- charge and as
42 per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC 31.00 Sqm 1,300.17
value not less than
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Mold resistance paperless Gypsum Ceiling
Providing and fixing a suspended ceiling system using a minimum 12.5 mm thick paperless,
modified glass fibre reinforced gypsum core board with enhanced moisture and mould resistance
as per EN 15283 Part-1. The board shall have a thermal conductivity of 0.3 W/mºK, thermal
resistance of 0.042 m²K/W, and conform to ASTM D3273 for mould resistance and EN520 Type
H1 for water resistance. The board shall have square or tapered edges on all four sides.
The suspension and grid system will be constructed from GI (IS-513), with a yield strength of
MPa, finished with a 150 GSM galvanized coating as per IS-277. The sections will feature a
serrated, knurled, chequered, or ribbed pattern. A 0.5 mm perimeter channel will be fixed along the
perimeter of existing walls using 6x40 mm impact anchors of an approved make at 600 mm
centres. A 0.5 mm ceiling angle will be suspended by attaching it to a soffit cleat, made of CR1
grade (IS-513) material, with a zinc coating of 7 to 8 microns and a pull-out load capacity of 6.8 kN.
This setup will create a 1200 mm x 1200 mm grid.
The intermediate channel, 0.9 mm thick, will be secured to the ceiling angle using an M6 x 12 mm
hex nut and bolt arrangement (material as per EN 10083, finish: zinc plating) or with 2 no. Ø4.2x13
metal-to-metal screws made of carbon steel as per EN-ISO 7049/50 with a minimum 4-micron zinc
coating. The ceiling section will then be fixed to the intermediate channel using connecting clips
made from high carbon spring steel wire (BS970 Gr. En 42, 46-48 HRC, finish: zinc plating 4-6
microns) and positioned perpendicularly to the intermediate channel at 600 mm centre-to-centre
Single-layer gypsum boards shall be secured to the ceiling section using 25 mm drywall screws
made of carbon steel (EN-ISO 7049/50). The joints shall be finished with a jointing compound,
recommended filler, jointing tapes, and finisher conforming to ASTM C475, to achieve a flush
appearance. The finishing process shall include two coats of primer suitable for the board, as per
the manufacturer’s specifications. The cost shall include making openings for light fittings, grills,
diffusers, and other cut-outs, framed with perimeter channels and fixed as per the drawings,
specifications, and directions of the Engineer in Charge, but excluding the cost of putty and
For false ceilings with drop-down pattas (vertical elements) exceeding a height or width of
mm, measurements and payment will be based on the actual installed area. The rate shall include
the cost of creating openings for light fittings, grills, diffusers, and other fixtures, framed with
perimeter channels and installed according to the drawings and specifications and as directed by
the Engineer in Charge. The cost excludes putty and painting.
The Contractor shall prepare shop drawings in coordination with all services, including provisions
for openings and access. Samples, shop drawings, and mock-ups must be approved by the
Engineer in Charge. Payment will be made based on the actual installed area, including vertical
drop-downs exceeding 300 mm, without accounting for any wastage or deductions for lights,
diffusers, columns, etc. No additional payment shall be made for making provisions for providing
lights, diffusers, AC grills, fire alarm systems, sprinkler systems, and other fittings/services.
Access panel/ trap door
Providing and fixing ready-made powder coated Access panel/ trap door of approved make of
600x600mm size for any height as per drawing including aluminium outer and inner frame, door
shutter, push latch, safety cable and hook, removable hinge, intermediate and perimeter channel
etc for all floor, all height etc complete as directed by engineer in charge. Tile/ board of access
panel shall be matched with false ceiling board. The contractor shall submit the technical data
sheet of the product regarding loading capacity to the engineer in charge. A loose and installed
sample/ mock-up of the access panel shall be approved by the engineer in charge.
The contractor shall prepare a shop drawing based on the concept drawing including fixing
44 arrangements, and services, and prepare a mock-up of the required area. As per the approved 2.00 No 1,872.84
shop drawing and mock-up, the contractor shall start the work.
The access panel system shall be fixed on any type of surface i.e. RCC, metal work, etc) with the
required capacity of anchorage as per the manufacturer's specification.
The contractor shall provide a fixing arrangement with an adjoining false ceiling and the bottom of
the slab. The stability of the access panel system shall be the responsibility of the contractor.
Total Carried Over to Summary
WALL PANELLING WORK/CURTAIN WORK
Iteam No. Item Description Quantity Unit Amount (in Rs.)
1) Contractor shall prepare shop drawing based on concept drawing/ design for all false ceiling,
panelling and partition work co-ordinate with services and get approved by Engineer in charge
before execution of work.
2) All veneer and wood shall be FSC (Forest Stewardship Council) & Green Guard Certified.
3) All Manufactured products shall be with at least 5% recycled content.
4) Sample of all loose material and mock-up shall be approved by Engineer in charge.
5) Any wood/ wood base material / plywood / MDF Board shall be treated with antitermite
treatment as per relevant IS before use. Rates are inclusive of anti-termite treatment of all such
6) Contractor shall co-ordinate for all services in wall panelling/ ceiling work i.e. making openings
for light fittings, switch board, electrical points, grills, diffusers, cut-outs for any services, provision
of addition framing member for strengthen, making good as per satisfaction of Engineer in charge.
7) All elements shall be factory fabricated and finished, only final finishing to be made on site with
all precautions.
8) Contractor shall coordinate all services work (cutouts and provisions) in all type of wall
panelling, false ceiling, partition, pelmet and other interior work. All cutout and services provisions
shall be finished at factory/ work shop.
Providing and fixing 12 mm thick plywood BWP grade (IS – 710) of approved make having, a
density minimum 600 Kg/m3, emission levels as per E-1 formaldehyde, for wall panelling/lining/
cladding/ False ceiling work, pelmet or any interior work in any design, any pattern, any shape with
necessary screws, for all height all level, etc complete as directed by Engineer-in-Charge. The rate
shall be inclusive of 6mm thick peripheral beading all around to ply (width of beading as per ply +
finish surface) as per drawing.
Veneer/ laminate or any other finish shall be paid in the relevant tender item. Out to out Area of
installed plywood shall be measured for payment without considering any wastage.
1 mm thick laminate
Providing & Fixing 1 mm thick high pressure (factory pressed) laminate sheet of any type, any
finish, any shade, any texture of approved make and shade with high-density protective surface
layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S, including cost
46 of adhesive of approved quality. Laminate shall be applied on the door shutter, wall paneling, 26.00 Sqm 647.56
ceiling, or any interior work, etc. The sample shall be approved by the Engineer-in-charge. The
actual installed area of the laminate shall be measured for payment.
Veneer Panelling
Providing and fixing Veneer Panelling/patta as per concept design/ drawing and as per the
following specifications:
1) Aluminium framing system for panelling shall be installed on any surface with the required size
and type of anchor fasteners of an approved make, with aluminium sections of approved make,
conforming to IS: 733 and IS: 1285; of required size and thickness at a maximum distance of
600mm c/c in both directions. All aluminium member shall be anodized finished of an approved
make and shade (anodized transparent or dyed to required shade according to IS: 1868, Minimum
anodic coating of grade AC 15). The aluminium quality shall be as per grade 6063 T6 and BS
2) 12mm thick, BWP grade (IS – 710) plywood shall be fixed with aluminium framing with the
required fixing arrangement and shall create the required shape, size and pattern in true line and
47 3) 4mm thick Gurjan ply veneer having a slice thickness of 0.5mm of an approved make and 13.00 Sqm 5,114.39
shade shall be fixed on plywood in the required pattern as per concept design/ drawings. Veneer
sheet shall be of approximate size 3048 x 1220mm (10' x 4’).
4) First class teak wood skirting and beading of required size shall be fixed on the ply surface with
required adhesive, nails, screws etc., as per the concept design/ drawings
5) All exposed veneer and wooden surfaces shall be finished with an exterior grade water base
Polyurethane (PU) clear matt finish/ glossy finish/ semi gloss finish polish of an approved make
and shade including surface preparation, base coat of wooden primer, stainer coat of approved
shade (if required), minimum 3 coats of PU polish followed by sandpapering with fine sandpaper
up to minimum 400 micro grit-sized sandpapers and up to satisfaction of Engineer-in-Charge.
6) Provision of fixing hanging shall be included and to be shown in shop drawing for fixing like
logo/frames/storage units/artworks etc.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
7) The wall panelling shall have provision of solid wood framework above the shelf to hang the
8) MEP services to be coordinated as per site conditions and drawings.
The Contractor shall prepare and submit a shop drawing that coordinates all services based on
the concept design and approved drawings. This submission must include detailed design
calculations for approval by the Engineer-in-Charge. The rate shall be inclusive of the aluminium
framing, plywood, veneer, wooden skirting, PU polish, designer cutting in the required shape, size
pattern, edge beading, arrangement for lighting and other services, hardware, adhesives,
accessories, anchors, fasteners, scaffolding, wastage, etc complete, for all levels, all height, all
floors as directed by Engineer in charge. A mock-up shall be carried out as per the approved shop
drawings. Work shall be carried out as per the approved sample, mock-up, and shop drawing
including all material and labour. The actual installed area in the elevation shall be measured for
payment without considering any wastage and without deductions of areas for any type of service
elements. No additional payments shall be made for provisions for fittings/services.
Fabric & acoustic panel wall panelling
Providing and fixing minimum 25mm thick Acoustic and Sound Absorption Panel System, of the
required size, manufactured from 100% polyester fibers/ polypropylene/ polyethylene terephthalate
panel Fibers Needle punched and thermally bonded in a non – woven matrix semi rigid specifically
tooled and pressed for maximum sound absorption, with minimum 80% NRC (0.80 NRC) and
meets the British Fire Rating Standards BS 476 standard Class 1Y, Class P, Fire Propagation
index = 9.2, with 0.006% moisture absorption (will not rot or smell) in grey or/ and white colour
fibers, which is UV stabilized, non-allergic and non toxic as per concept design/drawing and as per
the following provisioned:
1) A Paneling shall be installed on the required Metal/Aluminium framing system. The aluminum
quality shall be as per grade 6063 T6 and 6062 T6, 6061 T6 and comply to BS 1474. Framing
48 shall be fixed on any surface i.e masonry, stone, RCC, metal, der wall etc. 22.00 Sqm 5,761.09
2) Required thickness plywood, BWP grade (IS – 710) plywood shall be fixed with metal framing
with the required fixing arrangement in the required shape, size, and pattern.
3) Acoustic Panel System shall be fixed on the required thickness of plywood and metal framing
work (any type), which shall be fixed into the wall and shall create a true line and level with screws,
fixed horizontally or vertically as per design/drawing.
4) Acoustic and Sound Absorption Panel System shall be covered with a tightly stretched open cell
fabric over the entire panel including all sides. Designer Fabric with acoustic and fire retardant
properties of approved make and shade and selection as per approved sample shall be covered
on the acoustic panel for wall paneling work in the required pattern as per drawing with all
necessary stitching, adhesives, screws etc.
5) The acoustic panel with fabric shall be fixed with teak wood beading/lipping if required as per
6) All exposed surfaces of wooden shall be External grade water based PU polished as per
The contractor shall prepare a shop drawing coordination of services based on the concept design
and drawing and submit it along with the design calculation for approval from the engineer in
charge. The rate shall be inclusive of acoustic fabric panel, metal framing, plywood, teak wood
beading, designer cutting in the required shape, size pattern, edge beading, PU polish, Teak wood
lipping/bedading as per design intent, arrangement for lighting and other services, hardware,
accessories, anchor, fastener, adhesives, scaffolding, wastage, etc complete for all levels all
height, all floors as directed by Engineer in charge. A mock-up shall be carried out as per the
approved shop drawing. Work shall be carried out as per the approved sample, Mock-up, and
shop drawing including all material and labour. The actual installed area in the elevation shall be
measured for payment without considering any wastage and without deductions of area for lights,
diffusers, columns, etc. Nothing extra shall be paid for making provisions for providing
fittings/services.
Solid Wooden batten + Ply+Veneer paneling
Providing and fixing solid wooden batten acoustic wooden paneling as per concept design/drawing
and as per following provisioned:
1) A Paneling shall be installed on the required Metal framing system.
2) 19mm thick veneer finish plywood, BWP grade (IS – 710) plywood shall be fixed with metal
framing with the required fixing arrangement in the required shape, size, and pattern.
3) 4mm thick Gurjan ply veneer having a slice thickness of 0.3mm of approved make and shade
shall be fixed on plywood (factory pressed) in the required pattern as per concept design/drawing
with teak wood beading at the end of the panel of the required size.
4) Perforation shall be made in a pressed sheet of ply and veneer
49 with a cutting machine in a good finish wherever required to achieve acoustic properties. 16.00 Sqm 7,103.33
5) Finished 25mm x 40mm size Superior class teak wood strips/ battens @ 50mm c/c shall be
fixed on veneer-finished plywood panel as per drawing and shall create a true line and level with
required screws, nuts, fastener, adhesive, etc complete. The length of batten shall be as per the
approved drawing for joint.
6) Glass wool shall be laid in paneling for acoustic purpose.
7) All exposed surface of wooden and veneer shall be polished as per specification. Elevation
area of panelling shall be measured for payment without considering any wastage.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
The contractor shall prepare a shop drawing coordination of services based on the concept design
and drawing for approval from the engineer in charge. The rate shall be inclusive of plywood,
veneer, teak wood batten, Glasswool, perforation making, designer cutting in the required shape,
size pattern, edge beading, arrangement for lighting and other services, hardware, accessories,
adhesives, anchor, fastener, scaffolding, wastage, etc complete for all levels all height, all floors
as directed by Engineer in charge. A mock-up shall be carried out as per the approved shop
drawing. Work shall be carried out as per the approved sample, Mock-up, and shop drawing
including all material and labour. The actual installed area in the elevation shall be measured for
payment without considering any wastage and without deductions of area for fittings/services.
Mirror with aluminum frame:
Providing and fixing 6mm thick superior quality wall hung mirror with modular aluminium frame.
Mirror shall be extra clear, decorative type, best quality, bevelled edge at the periphery and of an
approved make, in any shape and size.
The aluminium frame shall be up to 100mm wide, extruded type, with anodized finish of an
approved make in any shape and shade.
The backing of the mirror shall be 8mm thick cement bonded particle board/fibre cement board/ IS
50 710 Marine Ply and fixed with silicon sealant/double sided tape to the mirror. 3.00 Sqm 4,010.71
The mirror assembly shall be with a floating hanging system with required hanger, Z bar or french
cleat etc., complete, in proper plumb and level etc. for all floors, all levels, all heights as directed
by the Engineer-in-Charge. The rate shall include the mirror,cement fiberboard, anodised
aluminium framing, including adhesive, double sided tape, screws, fasteners and all required
accessories. Out to out area of the mirror with the aluminium frame shall be considered for
payment without any wastage.
MDF Molding Patti
Providing and fixing approximate 25mm thick moulding patti made of MDF board of approved
make, fixed on masonry wall/ plywood/ RCC surface/ ceiling/ gypsum surface etc. Moulding patti
shall be in linear or curvature shape as per design/ drawing. Moulding shall be in tapered, circular
or any other shape in desired design and size with carving work (to create a design) as per
drawing. Moulding shall be fixed on levelled surface with adhesive, nails, wooden joints, SS
screws with out appearing any impression in vision. Location of joint in moulding patti shall be as
per design and as suggested by engineer in charge. Exposed surface offinished with water base
acrylic/ PU coating of approved make, shade and finish.
Contractor shall prepare shop drawing base on concept design and get it approved before starting
the work. Rate shall be inclusive of material, labour, finishing, wastage, fixing accessories,
scaffolding etc complete for all height and as directed by Engineer in charge. Sample and mock-up
shall be approved. Elevation of area of finished moulding shall be measured for payment.
Letter Mount Signage, Logo & Map signage
Providing and fixing Cut Letter Sign, Logo & Map of specified/required size as per design intent in
any languages, any font style as per concept design/ drawings, cut / routed from approx 2 mm thk
MS plate of variable size as per artwork/content schedule on any type of
surface(metal/masonry/stone/RCC or any other material in any shape) with anchor fastener of
required capacity and make or by any other means as per desig inent, at any level any height.
fabricated using water jet, CNC cutting machine, machine bending or by any means as required.
The top surface of the cut / routed letter/signage element to have a chamfer edge/rounded corner
as per the design intent. signage to be fixed and secured with 304 grade SS M5 grub screws on
304 grade SS required capacity stand-off pins anchored to mounting surface and with partially
threaded required length 304 grade SS studs using silicone caulk, on the mounting surface, as per
design intent. Letter, stand-off pins, studs, SS bolts, and fasteners to be finished with PU paint in
the required colors as specified in the final artwork/content schedule as per approved make.
Mounting of signage to be done using appropriate reusable templates,made in suitable material as
per requirement, with locations of studs, for drilling holes on the mounting surface, as per
artwork/design intent/content schedule. The loose sample of stone and laid mockup shall be
approved by the Engineer-in-charge before mass execution. The Architect and the Engineer-in-
charge reserves the right to reject part or all of the work if it is substandard not as per the
approved sample or per mock-up or does not confirm to the approved sample/mock-up. Content
of sign shall be letters (in any language), number, graphics/ maps, signs, arrows, etc. in any colour
as per design, drawing and approved by Architect and Engineer. The rate shall also include cost of
scaffolding, drilling, fabrication, finishing, adhesive material, back and sides plain cap sheet, fixing
charges, accessories, anchor/fastner etc at all height and all lead. Contractor shall prepare shop
drawing based on concept design, including it's fixing arrangement with back structure/ back
surface integrated with wall finishing work, all services work (i.e. lighting work). Sample and mock-
up shall be approved before mass production and execution. Stability of fixing for signage and
logo shall be responsibility of contractor. The contractor shall submit the drawings with as per
design intent before execution. Outer most dimension of the letters shall be measured for payment
and Elevation area of MS logo and Map shall be measured for payment.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Providing and fixing SS 304 grade brush finish 1.0 mm thick Internal signage of any shape any
size and in any language like Gujarati, Hindi and English with letter, numbers, graphic, arrow,
symbol etc made by etching with duco paint/ laser print or vinyle sticker with lamination of
approved shade. All signage plates shall be made in CNC water jet cutting, with all smoothen
edges and pencil round corner. Signage matter shall be as per drawing. The plate shall be fixed on
53 brick masonry or RCC wall/ door with the necessary fixing like stud, fastner, self adhesive or 8.00 Sqm 18,558.75
adhesive etc complete for all floor all height as directed by Architect and Engineer in charge. The
rate shall be inclusive of all material, labour, drilling, fasteners/ adhesive, scaffolding etc. at all
heights. Only elevation area shall be measured and paid. The contractor shall submit the shop
drawings based on concept design and prepare the sample and get it approval before execution.
Total Carried Over to Summary
PAINTING/POLISHING WORKS
1) All adhesives, sealants & paint shall be water based, with low VOC with acceptable VOC
content as per Green Building Norms requirements and lead free.
2) Paint shall be applied after thoroughly brushing the surfaces, free from mortar dropping and
other foreign matter, preparing the surface even and sand papered smooth etc, after applying
every coat of putty and primer complete.
3) Contractor shall furnish warranty paper, wherever applicable.
4) If necessary more coats shall be applied till the surface presents a uniform appearance without
any extra cost.
5) Paint shall be applied with any means (i.e. brush, roller, spray etc)
6) Contractor shall prepare sample of minimum three shades as suggested by engineer in charge
7) The rate shall be applicable for all floor, all level, all height by any means of scaffolding.
White cement-based putty
Providing and applying white cement-based putty of average thickness 1 mm, of approved make
54 and manufacturer, over any surface to prepare the surface even and smooth complete for all floor 571.00 Sqm 81.31
all height all levels.
Providing and applying priming coats with the primer of approved make and manufacture, having
low VOC (Volatile Organic Compound) content, Modified acrylic, water-based alkali-resistant
primer with low VOC over any surface to complete for all floors all heights all levels.
Acrylic emulsion paint - interior grade
Providing and applying premium acrylic emulsion paint (superior quality) of interior grade Two
coats of interior grade premium acrylic emulsion paint of approved make and shade with highly
washable, Anti fungal, anti bacterial, scratch resistant and scrub resistance property, having VOC
(Volatile Organic Compound) content less than 50 grams/ litre of approved make, on wall/ ceiling/
false ceiling/ partition etc including applying additional coats wherever required to achieve desired
even shade and colour.
PU polish - for external/internal wooden & veneered surfaces:
Providing and applying interior/exterior grade water-based polyurethane (PU) polish of any shade
and finish (matt, glossy, or semi-glossy) of an approved make on new or existing external and
internal wooden and veneered surfaces at all levels and heights. The polish work shall be carried
out as follows:
1) Surface Preparation: Sandpapering with various grades, up to 220 macro grit, to the satisfaction
of the Engineer-in-Charge.
2) Sealer Application: Applying two coats of sealer using a spray gun or other suitable means,
allowing sufficient drying time as per the manufacturer’s specifications.
3) Wet Rubbing: Once the sealer coat has dried, wet rubbing with fine emery cloth using ample
water to remove the excess sealer layer and smooth the surface. After wet rubbing, apply special
grade PU fillers to fill any small or large holes/grooves. Allow the filler coat to dry as per the
manufacturer’s specifications.
4) First Coat of PU Polish: Apply the first coat of PU polish with a spray gun or suitable means.
Once dry, sandpaper the surface using fine sandpaper up to 400 micro-grit. This process shall be
repeated three times, ensuring a smooth finish.
5) Stainer Coat Application: Apply a stainer coat of the approved shade, if required. Sandpaper the
wood surface using fine sandpaper up to 600 micro-grit as per step wise requirement for polishing,
to achieve a smooth finish, to the satisfaction of the Engineer-in-Charge.
The polish application shall be conducted according to the manufacturer’s specifications and as
directed by the Engineer-in-Charge. A sample must be approved by the Architect before the full
execution of the work. The single time applied area of polish shall be measured for payment
without considering any wastage.
Total Carried Over to Summary
Iteam No. Item Description Quantity Unit Amount (in Rs.)
1. All adhesives, sealants & paint shall be with low VOC with acceptable VOC content as per
GRIHA requirements and lead free.
2. The Contractor shall prepare shop drawings based on the concept design/ drawings for any
type of fabrication work and get them approved. The Contractor shall prepare mock-
ups/prototypes (as suggested) as per the approved shop drawings for approval. Work shall be
carried out as per the approved shop drawings, approved mock-ups/prototypes and as suggested
by the Engineer-in-Charge.
3. The rate shall be for all floors, all levels and for all heights.
4. The rate shall include the cost of all types of fasteners (ETA approved) to be used for fixing.
5. Structural stability shall be responsibility of the Contractor for all kinds of metal work.
6. All elements shall be factory fabricated and finished, only final finishing to be carried out on site
with all precautions.
7. The Contractor shall coordinate all services related work (cut-outs and provisions) in the metal
work. All cut-out and services provisions shall be finished at the factory/work shop.
8. The Contractor shall provide PVC/nylon seprators, where two different metals connect, to avoid
galvanic reactions.
Structural steel work - Fabrication works - with PU paint:
Providing, fabricating, assembling, hoisting, erecting and fixing in position, structural steel work, at
all heights, all levels, all shapes & sizes with all leads & lifts, using any type of MS sections like
rolled steel sections, hollow sections, plates, chequered plates, bars, sheets, rods, threaded bolts
etc. all conforming to the latest relevant IS codes for the metal elements, i.e. railings, signage
poles, gates, bus shelters, screen walls, commercial poles, gantry structure, grills, bracings,
foundation plates & bolts, platforms, brackets, fencing poles, framing for advertisement boxes on
lighting poles, electrical elements etc. including straightening, cutting, bending, bolting and welding
the members, all as per the structural drawings and as per detailed specifications (for materials &
58 workmanship) including profile cutting, smooth grinding, machining of edges/faces, all necessary 100.00 Kg 111.20
welding (electric arc welding) for the required weld lengths and sizes, machine drilling of holes for
joining/anchoring, all necessary arrangements for templates to keep the foundation bolts in
position, dry sanding, degreasing (wet cleaning) & preparation of rust-free surfaces manually or
mechanically, metal putty to make the surfaces even and smooth, necessary scaffolding/staging,
anchor fasteners for fixing, etc., complete, for all floors, all heights and all level as directed by the
Engineer-in-Charge.
Additionally, the fabricated steel work will be finished with PU paint to ensure durability and
aesthetic quality.
The Contractor shall prepare coordinated fabrication/shop drawings and obtain approval before
commencing any fabrication work along with design calculations to ensure the stability of the
elements. All fabrication work must be executed with precise architectural workmanship and in
accordance with Sections V and VI of IS 800 and IS
The rate shall include the application of two or more coats of PU paint (DFT min 40 micron per
coat) on all surfaces of MS members of approved make and shade. This shall be applied over two
coats of anti-corrosive epoxy base primer (DFT minimum 50 microns per coat), as per the
manufacturer’s specifications, anchor fasteners, etc., all complete. The weight (by theoretical
means) of MS members/structure/element shall be measured for payment without considering
wastage, fixing accessories such as nuts, bolts, fasteners etc.
Total Carried Over to Summary
WATER SUPPLY, PLUMBING & SANITARY FITTINGS
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making good the wall, ceiling and floor etc. complete.[A] 15 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making good the wall, ceiling and floor etc. complete.[B] 20 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube
fittings and clamps including making good the wall, ceiling and floor etc. complete.[C] 25 mm.
62 Providing and fixing brass screw down stop tap. [C] 25 mm. 2.00 Each 220.82
63 Providing and fixing Gun metal check or non-return full way wheel valve. [C] 25 mm. 2.00 Each 420.63
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the
64 following nominal diameter of self cleansing design with C.I scread down or hinged grating 2.00 Each 599.64
including the cost of cutting and making good the floor.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for waste
water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the
65 help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings 2.00 RMT 148.12
etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS
13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm
66 diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be 4.00 RMT 876.90
concealed in floors as directed including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing and fixing of 110mm Diameter SWR quality (type B) UPVC fitting of Swept Tee with
door, confirming to IS 14735 laid in proper line and level complete as per drawing and direction
67 and satisfaction of Engineer in Charge. 1.00 Each 372.03
Make: Astral / Ashirvad / Prince
Supplying, fixing, testing and commissioning of white Vitreous China Wall Mounted water closet
(European type EWC-P) as per IS: 2556 (Part 2) , with soft close seat and lid as per IS: 2548, of
size and shape as approved by engineer in charge, including rag bolts, fixing in position, grouting
68 and finishing, making good the walls and floors wherever required. The work to be completed in all 1.00 Set 24,060.62
respect to the satisfaction of Engineer-In-Charge.
a) EWC-P:- Make: Kohler / Toto / American Standard
Providing and fixing UPVC SWR WC Connector 130 x 110 mm dia. Socket type of approved
make, fixed to outlet gaskets with UPVC Lubricant or Solvent Cement, all complete as per
69 directions of the Engineer-in-charge. 1.00 Each 215.99
Make: Astral / Ashirvad / Prince
Supplying, fixing, testing & commissioning of Single Piece Concealed Cistern Body with installation
kit & 'P type' drain pipe connection & Full Frame set for wall hung WC, with dual flush 3/6 ltr with
wall flush plate of approved make including concealed valve and push fit flexible hose complete
including cutting and making good the walls where required complete as directed by Engineer-in-
The scope includes the following:
a) Flush Tank with Full Frame; & Dual Flush Plate:- Make: Kohler / Toto / American Standard
Supplying, Fixing & Installing of white vitreous China Over Counter Wash Basin as per IS:
(Part 4) of size and shape as approved by engineer in charge,, including drilling hole for the faucet
& waste coupling, filling the gaps with appropriate silicon cement, complete as per the direction,
approval and complete satisfaction of the Engineer-in-charge.
Over counter Basin - Make: Kohler / Toto / American Standard
Providing, fixing, testing and commissioning of chrome plated Brass Angle valve / Angular Stop
Cock with wall flange, including connection with the water supply pipeline, complete as approved
72 and directed by the Engineer-in-charge. 3.00 Each 1,259.07
Angle Stop Cock - Make: Kohler / Toto / American Standard
Providing and fixing 32mm Grid Drain (with Full thread) (Waste Coupling) without overflow, in
Polished Chrome of approved make and conforming to Manufacturers Standards. Work to be
73 completed to the satisfaction of the Engineer-In-Charge. 2.00 Each 1,364.96
Make: Kohler / Toto / American Standard
Providing and fixing 32mm CP 300mm bottle trap with wall flange, of approved make and as
74 directed by Engineer-in-charge. (For Wash Basins). 1.00 Each 956.47
- Make - Kohler / Toto / American Standard
Providing and fixing Chrome plated ABS Hand Shower (Health Faucet), having a discharge of
LPM, including 8 mm dia, 1 Meter long Flexible tube & wall hook including connection with the
75 angular stop cock, complete of approved make and quality and as approved by Engineer - In - 1.00 Each 1,971.57
Make: Kohler / Toto / American Standard
Supplying and fixing of single toilet paper roll holder with flap made of stainless steel material, at
76 levels as directed by the Engineer in charge. 1.00 Each 1,821.43
Make: Kohler / Toto / American Standard
Supplying, fixing, testing and commissioning of S.S. single robe hook of approved make, fixed to
PVC cleats with C.P. brass screws, etc. all necessary accessories complete as per direction of
77 Engineer-in-charge. 2.00 Each 1,582.82
Make: Kohler / Toto / American Standard
Providing and fixing of 610mm long SS Towel bar in polished chrome with wall flange of approved
78 make as per drawing and direction and satisfaction of Engineer in Charge. 1.00 Each 1,821.43
Make: Kohler / Toto / American Standard
Providing & fixing heavy quality SS 316 grade polished chrome body touchless soap dispenser of
size 180 x 320 x 150mm battery operated having 2 sets of AA or AAA batteries as required, driling
holes in walls / tiles, attaching the mounting brackets with appropriate fasteners, filling the
79 dispenser with 0.5 litres of liquid / gel soap as per manufacturers' standards, testing and 1.00 Each 20,496.84
commissioning as approved and directed by the Engineer-in-charge.
Make - Kohler / Toto / American Standard
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Providing & fixing heavy quality hidden square floor drain cover in polished chrome of size 100 x
100 x 82mm, connected to Nahni trap including setting in floor with white cement sand mortar 1 :
80 to match with floor finish with proper care for preventing side leakages, as approved and directed 2.00 Each 3,275.63
by the Engineer-in-charge.
Make: Kohler / Toto / American Standard
Total Carried Over to Summary
FURNITURE WORKS
1) All wooden furniture shall be manufactured from Superior class teak wood, BWP IS-710 ply,
veneer, laminate, customized/ readymade fabric as per selection, exterior grade PU polish as per
specifications and approved by the & Architect.
2) "Furniture Intent Document" to be referred for furniture reference image, furniture code and
sizes for all the furniture items as given in the schedule. The contractor shall prepare and submit
shop drawings and prototypes of various furniture items as required by Engineer-in-charge for his
approval. Shop drawings should be submitted before preparing prototypes. Mass production shall
be carried out only as per approved samples/prototypes. The contractor has to submit the “As
Built” shop drawing for completed furniture items.
3) Contractor shall be responsible for stability of all furniture items.
4) Provision for connectivity of Power outlets, Multimedia, AV, internet, laptop power, extra power,
microphone, etc. or similar to be given in the furniture with cable organizer, grommet, vertebrae
vertical cable, cable tray etc. (whatever required) or similar to be coordinated with electrical
drawings, which shall be included in the quoted rate of furniture item. However, items like
multimedia, AV, internet, laptop power, extra power, microphones etc., shall be payable under
relevant tender items.
5) "Procurement of items with aesthetic value and visibility shall be on prior approval of Engineer
in charge for specific area of application.
6) Front elevation area of storage unit/ mechanically driven compactor system/ mobile storage
shall be measured for payment in Sqm unless otherwise specified. (Front elevation facing the
storage shelves of compactors/ storages unit shall be considered for measurement.)
7) Cost of each desk shall be inclusive of fliptop panel, grommet wherever specified in particular
item description/ Data sheet. Accessories like desk organiser, monitor arm, bag hook, etc.are
8) Fabric and stone shall be selected and approved by Architect & Engineer-in-charge.
9) Lipping shall be of minimum 2mm thick solid teak wood unless otherwise specified.
10) Only First class teak wood shall be used for any kind of woodwork. All wood (best quality, kiln
seasoned, termite treated and sorted for uniform veins wood) and wood base material shall be
treated with anti-termite treatment as per relevant IS before use and after installation. The
guarantee shall be furnished for 10 years in the prescribed format as directed by EIC.
11) Veneer shall be 4mm thick of natural teak wood selected and sorted for uniform veins, as
approved by engineer-in-charge. The natural veneers slice shall be minimum of 0.5mm thick and
backed ply shall be of BWP grade and density shall be minimum 650 kg/ m3.
12) Laminates shall be 1mm thickness of any colour, finish, texture as approved by engineer-in-
13) All the faces of ply are to be finished with either laminate or veneer, if not specified in the ref.
14) The dimensions of furniture unit and its members mentioned in BOQ item & furniture intent
document are indicative and nothing extra shall be paid or recovered for variation in actual
dimension up to +/- 10%
15) The reference image given are indicative. In case of any discrepancy between BOQ item and
furniture intent document, the BOQ item shall prevail. Incase of any discrepancy within furniture
intent document, decision of engineer-in-charge shall be final and binding.
16) Incase of any discrepancy in specifications between furniture intent document and specified
model of item, the furniture intent document shall prevail.
17) In case, model specified in BOQ item/ furniture intent document of any furniture item is
changed/not available with the manufacturer, the alternate equivalent or superior model of same
company can be considered with the prior approval of Engineer-in-charge and nothing extra shall
be payable for the same.
18) If item/reference image has brass letters/emblem then such brass item shall be paid for in
relevant tender item.
19) Shutter stiffeners to be provided in full height (3300 mm) storages to maintain the strength of
the shutters and to avoid bending of shutters as per requirement and in consultation with the
engineer-in-charge.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
20) The aluminium and MS tube/pipe shall be of minimum 2mm wall thickness unless otherwise
21) The Desk & Workstation tables top thicknesses may be varied as per functional comfort and
as directed by engineer-in-charge.
22) For storages the carcass & internal support shall be made of minimum 19mm thick IS
Grade ply and shelves and backing of carcass shall be minimum 12 mm thick IS 710 Grade ply.
However, for members of large span/height, higher thickness of ply shall be provided for structural
stability & functional comfort for which nothing extra shall be payable over the quoted price.
23) For veneer finish wall panelling, veneer sheet shall be of approximate size 3048 x 1220mm
24) Exterior Grade water based open grains PU polish to be provided on all wooden and veneer
CUSTOM-MADE CATEGORY:
Executive Desk with two (2) return units - C-DK-02
Approximate Dimension (L x W x H) - 3000 X 1050 X 750, two (2) Return unit - 1625 X 600 X
Supply and Installation of the Executive Desk with two (2) return units having a main table as per
81 the reference image. The Executive Desk with two (2) return unit items shall be as per the furniture 1.00 No 2,40,998.63
Low height Storage Unit - C-SU-03 (Main Office)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture
intent document
82 Supply and installation of the low-height storage unit as per the reference image. The low-height 7.00 Sqm 54,222.30
storage unit item shall be as per the furniture datasheet. The front elevation area of the storage
unit shall be measured for payment.
Low height Storage Unit - C-SU-08 (PA office)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture
intent document
83 Supply and installation of the low-height storage unit as per the reference image. The low-height 3.00 Sqm 35,957.31
storage unit item shall be as per the furniture datasheet. The front elevation area of the storage
unit shall be measured for payment.
Full Height Storage Unit - C-SU-09 (PA office)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture
intent document
84 Supply and installation of the full height storage unit as per the reference image. The full height 6.00 Sqm 31,963.47
storage unit item shall be as per the furniture datasheet. The front elevation area of the storage
unit shall be measured for payment.
Storage Unit - C-SU-10 (Ante room)
Approximate Dimension (L x W x H) - As per Furniture intent document x 700 x As per Furniture
intent document
85 Supply and installation of the storage unit as per the reference image. The storage unit item shall 2.00 Sqm 55,363.40
be as per the furniture datasheet. The front elevation area of the storage unit shall be measured
C-TB-14 (Near Conference table)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture
intent document
86 Supply and installation of the storage unit as per the reference image. The storage unit item shall 1.00 No 41,359.50
be as per the furniture datasheet. The front elevation area of the storage unit shall be measured
C-SU-58-LI (Main cabin near seating)
Approximate Dimension (L x W x H) - As per Furniture intent document x 450 x As per Furniture
intent document
87 Supply and installation of the storage unit as per the reference image. The storage unit item shall 5.00 Sqm 1,12,817.45
be as per the furniture datasheet. The front elevation area of the storage unit shall be measured
Side Table - C-TB-07 (Main cabin, Ante Room)
Approximate Dimensions (LX W X H ): 550 x 400 x
88 Supply and Installation of side table as per the reference image. The item shall be as per the 4.00 No 24,258.94
furniture data sheet.
Side Table - C-TB-11 (Ante room)
Approximate Dimensions (LX W X H ): 900 x 550 x
89 Supply and Installation of side table as per the reference image. The item shall be as per the 1.00 No 54,085.50
furniture data sheet.
Side Table - C-TB-11A (Main Office)
Approximate Dimensions (LX W X H ): 900 Dia x 385 H
90 Supply and Installation of side table as per the reference image. The item shall be as per the 1.00 No 60,846.19
furniture data sheet.
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Conference Table - C-TB-12
Approximate Dimension (L x W x H) - 4200 X 1500 X
91 Supply and Installation of the conference table as per the reference image. The item shall be as 1.00 No 3,15,763.88
per the furniture data sheet.
Work station - C-WS-01
Approximate Dimension (L X W X H): 1200 X 700 X
92 Supply and installation of the workstation desk table as per the reference image. The item shall be 3.00 No 29,694.00
as per the furniture data sheet.
Two seater sofa with solid wooden frame and legs - S-SF-02 (main cabin)
Approximate Dimensions (L X W X H): 1800 X 725 X
93 Supply and installation of a two seater sofa as per the reference image. The item shall be as per 1.00 No 99,819.56
the furniture data sheet and fabric as per fabric selection package.
Single Seater Sofa - S-SF-03 (Main cabin)
Approximate Dimensions (LX W X H ): 750 x 725 X
94 Supply and installation of Single Seater Sofa made as per the reference image. The item shall be 2.00 No 74,367.56
as per the furniture data sheet and fabric as per fabric selection package.
Single seater sofa - S-SF-04 (Ante room)
Approximate Dimension (L X W X H): 790 x 780 x
95 Supply and installation of single seater sofa as per the reference image. The item shall be as per 1.00 No 36,928.73
the furniture data sheet and fabric as per fabric selection package.
Two seater sofa with solid wooden frame and legs - S-SF-06 (Waiting Room)
Approximate Dimensions (L X W X H): 1800 X 780 X
96 Supply and installation of a two seater sofa as per the reference image. The item shall be as per 1.00 No 99,819.56
the furniture data sheet and fabric as per fabric selection package.
Diwan sofa - S-DI-01 (Ante room)
Approximate Dimension (L X W X H): 2010 x 850 x
97 Supply and installation of diwan with bolster pillow as per reference image. The item shall be as 1.00 No 50,904.00
per the furniture data sheet and fabric as per fabric selection package.
Partition Screen - E-SI-02 (Main cabin)
Approximate Dimension (L x W x H) - As per Furniture intent document x 50 x As per Furniture
intent document
98 Supply and installation of partition screen as per reference image. The item shall be as per the 4.00 Sqm 20,547.19
furniture data sheet. The front/ single side only elevation area of the Partition Screen shall be
measured for payment.
Coat Hanger - E-SI-04 (main cabin)
Approximate Dimension (D1 X D2 X H): 480 x 450 x
99 Supply and Installation of a free standing coat hanger as per reference image. The item shall be 1.00 No 17,498.25
as per the furniture data sheet.
Chair - S-CH-04 (Main cabin)
Approximate Dimension (L X W X H): 560 x 650 x
100 Supply and installation of a chair made as per reference image. The item shall be as per the 8.00 No 20,679.75
furniture data sheet and fabric as per fabric selection package.
C-TB-10 (Waiting Room-Corner Table)
Approximate Dimension (L x W x H) - As per Furniture intent document x 400 x As per Furniture
intent document
101 Supply and installation of the storage unit as per the reference image. The storage unit item shall 2.00 No 30,621.94
be as per the furniture datasheet. The front elevation area of the storage unit shall be measured
C-TB-13 (Waiting Room-Corner Table)
Approximate Dimension (D x H) - As per Furniture intent document x 450 Dia x As per Furniture
intent document
102 Supply and installation of the storage unit as per the reference image. The storage unit item shall 1.00 No 31,417.31
be as per the furniture datasheet. The front elevation area of the storage unit shall be measured
Chair - S-SF-07 (Waiting)
Approximate Dimension (L X W X H): 600 x 580 x
103 Supply and installation of a chair made as per reference image. The item shall be as per the 3.00 No 38,575.69
furniture data sheet and fabric as per fabric selection package.
TOTAL FOR CUSTOM-MADE CATEGORY:
BOUGHT OUT CATEGORY
Task chair - S-CH-01
Supply and Installation of chair as per reference image, furniture intent document, approved make
104 and model as under. 1.00 No 13,459.87
Godrej : Cross Full Back Knitted Fabric Ergonomic Office Chair (Black Ink)
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Main Chair - S-CH-02
Supply and Installation of high back chair as per reference image, furniture intent document,
105 approved make and model as under. 1.00 No 16,543.80
Featherlite: Liberate high back leatherette chair.
Mid Back chair - S-CH-03
Supply and Installation of chair as per reference image, furniture intent document, approved make
106 and model as under. 13.00 No 13,122.63
Godrej: Motion High Back Knitted Fabric Ergonomic Office Chair.
TOTAL FOR BOUGHT OUT CATEGORY:
TOTAL FOR FURNITURE WORKS:
1. "Procurement of items with aesthetic value and visibility shall be on prior approval of Engineer in
charge for specific area of application."
2. Item shall be executed for all spaces / areas / rooms / buildings etc. with different types of
fabrics / materials as per selection (provided in soft furnishing package document) and as
suggested by engineer in charge.
3. The contractor shall get the approval of each sample of material for curtain / blinds (fabric, PVC,
UPVC slats, etc.), fixing accessories, carpet etc. from the engineer-in-charge before execution for
respective areas.
4. Contractor shall co-ordinate and execute any type of services required in soft furnishing work.
Hand Tufted 100 % wool as per required Tufts per square inch
Supply and stacking of area rug/carpet as per the approved design and colour made out pure wool
of approved quality and specification. There shall be hand tufted construction technique, as per
the specified shape and size, installation, transportation and carriage all complete as per direction
of the engineer-in-charge.
The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools &
107 tackles of approved make for all floors, all heights, all levels and all places. The contractor shall 8.00 Sqm 9,234.43
get the sample approved by the engineer-in-charge before execution. Design shall be finalized as
per design samples submitted by agency and approved by engineer in charge. The actual laid
area shall be measured for payment without considering any wastage.
Design: Malak Hand Tufted Woolen And Viscose Rug
Make - Obeetee Carpets
Hand Woolen Carpet
Supply and stacking of area rug/carpet as per the approved design and colour made out pure wool
of approved quality and specification.
The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools &
tackles of approved make for all floors, all heights, all levels and all places. The contractor shall
get the sample approved by the engineer-in-charge before execution. Design shall be finalized as
per design samples submitted by agency and approved by engineer in charge. The actual laid
area shall be measured for payment without considering any wastage.
These carpets are washable.
Design: Victoria Hand Tufted Woolen Rug
Make - Obeetee Carpets
TOTAL FOR CARPET WORKS:
Cellular shades - Motorized
Providing and fixing of Cellular shades with motorized operating as per the curtain the reference
109 image. Cellular shades selection as per the reference image/ intent. The actual elevation area of 31.00 Sqm 7,650.45
curtains in a closed condition shall be measured and paid. The rate shall be applicable for all
heights and all floors.
Cellular shades - Manual
Providing and fixing of Cellular shades with Manual (chain) operating as per the curtain the
110 reference image. Cellular shades selection as per the reference image/ intent. The actual 15.00 Sqm 2,959.86
elevation area of curtains in a closed condition shall be measured and paid. The rate shall be
applicable for all heights and all floors.
TOTAL FOR CURTAIN WORKS:
Iteam No. Item Description Quantity Unit Amount (in Rs.)
Providing, transporting and arranging / fixing in position various Wooden Frame section of any
size made of approved teakwood / hardwood and polish of approved shade and finish including
approved carving, inlay, hand painting, engraving, decorative metal works or any other type of
111 decorative works of any material and any finish. Including fixing clamps, mounting material, 5.00 Sqm 11,783.32
backing material, glass, any other hardware, as per approved material / finish, to the various areas
as per direction of Architect and Engineer Incharge of having different basic rates as following -
TOTAL FOR FRAMED ART WORKS:
ACCESSORIES WORKS
The contractor shall have to co-ordinate for the below mentioned loose accessories and make
arrangements as per drawing and as suggested by Engineer in charge.
The contractor shall arrange samples of all type of accessories (with different material and design)
for review and approval. Contractor shall arrange mock-up for specific area with collected samples
as suggested by Engineer in charge.
After reviewing the mock-up, any modifications/ alterations suggested by the Engineer in charge
shall be incorporated. This process shall continue until final approval of the mock-up is received
from the the Engineer in charge.
The contractor shall have to shift or re-arrange the loose accessories as per the requirement of
the Engineer in charge.
The rate shall be inclusive of charges for necessary equipments (tools and tackles) needed for
shifting the accessories anywhere within the entire site, packing, un-packing, re-packing,
protecting, cleaning, maintaining, storing, etc complete as suggested by Engineer in charge. The
rate shall be applicable for all height, all floors.
The contractor will have to co-ordinate for the loose accessories and make arrangements to shift
the loose accessories as per the requirement of the Engineer in charge.
Providing, transporting and arranging / fixing in position various Dispenser to the various areas as
per direction of Engineer Incharge-
Aroma dispensers (Automatic) - AD1
Providing, transporting and arranging / fixing in position dust Bin to the various areas as per
113 direction of Engineer Incharge - 3.00 No 1,627.87
Providing, transporting and arranging / fixing in position Tea coasters / Tea Set to the various
areas as per direction of Engineer Incharge -(including stand of the coaster as per selection)
Tea coasters - TC4
Providing, transporting and arranging / fixing in position Tissue box and Tissue Box Covers to the
115 various areas as per direction of Architect and Engineer Incharge - 2.00 No 4,028.84
Tissue Box - TI1
Providing, transporting and arranging / fixing in position Pen Pencil Holder to the various areas as
per direction of Engineer Incharge -
Pen / Pencil holders - TS2
Providing, transporting and arranging / fixing in position Desk Organizer to the various areas as
117 per direction of Engineer Incharge - 1.00 No 1,887.69
Desk organizer - TS3
Providing, transporting and arranging / fixing in position tray to the various areas as per direction
118 of Engineer Incharge - 1.00 No 2,119.94
Providing, transporting and arranging / fixing in position Table Vases with flowers to the various
119 areas as per direction of Architect and Engineer Incharge - 1.00 No 3,604.64
Table Vase - VA6
Providing, transporting and arranging / fixing in position Wall Clocks to the various areas as per
120 direction of Architect and Engineer Incharge - 2.00 No 2,911.07
Wall Clock - WC2
TOTAL FOR ACCESSORIES WORKS:
Item no Item Description Unit Qty. Rate
Electrical Works
Distribution BoardMCB 's and its Accessories
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
(A) 6 to 32 Amp. Cat.III
Providing & erecting 415V MCB Four Pole for Motor & Inductive Load (CCurve) having
KA breaking capacity & confirms to IS:8828 in existing box having following capacity (b)
123 PlasticenclosurefittedwithDINrailsuitableforincorporating Three /Four nos. MCB No. 2 107.13
Total Carried Over to Summary
Cable Tray & Racway
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking
of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of
concrete of screed water with all accessories,Junction Box,Joints as required and
124 demanded by engineer-incharge and laying/erecting as per OEM guidelines and as per Mtr 30 1,034.36
instruction of engineer incharge having following size of dimensions and No of
compartments (W x D x T) Cat-III
[11] 225mm x 38mm x 1.6mm with Three Compartments
125 [10] 150mm x 38mm x 1.6mm with Three Compartments Mtr 25 724.36
126 [7] 50mm x 38mm x 1.6 mm with One Compartments Mtr 15 282.18
Supplying & Fixing of 250mm (L) x 250mm (W) x 50 – 80 (H) / 60- 75 (H) / 65 - 90(H)
adjustable height floor Cross Over Type junction box made out of pre galvanized sheet
min. 1.6mm thick base, cover & min. 2.0 mm thick for Lid with Electrostatic polyster epoxy
coating or 275 GSM coating mass. minimum 8mm Trap lid to be provide to acodomate the
specified flooring. The base of junction box should have pre punched / champhered
knockouts on all four sides to accomodate trunking from a minimum 50mm to maximum
225mm width & 38mm height. The system must have smooth curved die cast pillars for
ease of pulling cables. The cross over boxes should have flyover units made of abs plastic
or metal to route and distribute power, data & other cables. Cover of junction box should be
complete as required as per detail specificaton.
Supplying & Fixing of 150mm (L) x 150mm (W) x 50 – 80 (H) / 60- 75 (H) / 65 - 90(H)
adjustable height floor junction box made out of pre galvanized sheet min. 1.6mm thick
base, cover & min. 2.0 mm thick for Lid with Electrostatic polyster epoxy coating or
GSM coating mass. minimum 8mm Trap lid to be provide to acodomate the specified
flooring. The base of junction box should have pre punched / champhered knockouts on all
four sides to accomodate trunking from a minimum 50mm to maximum 225mm width &
38mm height. The system must have smooth curved die cast pillars for ease of pulling
cables. The cross over boxes should have flyover units made of abs plastic or metal to
route and distribute power, data & other cables. Cover of junction box should be complete
as required as per detail specificaton.
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof confirming BS with necessary end
129 caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and Mtr 20 405.28
measuring of following sizes
(2) 100 mm x 50 mm trunking
Total Carried Over to Summary
Internal Wiring
Item no Item Description Unit Qty. Rate
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade HFFR insulated multi strand copper wires up to 10 mtr length
in below type of pipe erected with 6A Modular type switch / bell push & accessories and
earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade HFFR insulated multi strand
copper wires, in below type of pipe to be erected complete with earth continuity and
necessary connection with primary light with accessories erected on Metal / PVC /
wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.
(b) with 16 swg(1.6 mm thick) HGS metal conduit pipe and accessories painted black
erected flushed on wall/ceiling complete. Cat-III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked 1.1 KV grade HFFR insulated multi strand copper
wires erected in below type of pipe with 6A Modular type switches and following type of
accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
One 6 A x 5 pin 250 Volt socket outlet point controlled by one 6 A switch located on switch
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade HFFR insulated multistrand copper wires, in following type of to be
erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin
Plug/Socket erected on PVC / Metallic box covered with appropriate front plate modules
134 erected on / in wall / ceiling as per pipe erected with following type of accessories. No. 35 549.59
[I] For 6A Plug/Socket and 6 A switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC /
135 Metallic box, single mounting base frame covered with textured / metallic front plate No. 7 239.30
modules erected on / in wall / ceiling with following type accessories. Cat.iii
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade HFFR insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug /Socket erected
on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in
wall / ceiling as per pipe erected with following type of accessories.
[II] For 16A Plug/socket and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade HFFR insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug/Socket erected
on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in
137 wall / ceiling as per pipe erected with following type of accessories. No. 5 880.59
[III] For 16A Plug/Socket and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm (
green) earthing wire from mcb d b board.
(b) with 16 swg HGS metal conduit pipe and accessories painted black erected flushed on
wall/ceiling complete. Cat-III
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed by Engineer In charge.
(20) Modular Buzzer-Cat.III
Supplying and fixing of following sizes of steel conduit along with accessories in
surface/recess including painting in case of surface conduit, or cutting the wall and making
good the same in case of recessed conduit as required.
Item no Item Description Unit Qty. Rate
Total Carried Over to Summary
Light Fixtures & Fans
Supplying installation testing & commissioning of approx 28W suspended/surface mounting
type LED 4 feet Luminaire, IP 20 ,colour temperature 4000 to 6500 K having efficiency not
less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum housing, inbuilt electronic
143 driver, suspension arrangement for pendent mounting through suspension bracket No. 6 4,336.56
including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed copper conductor cable
and earthing etc. as required. (Any one make of REGENT(slash s) - LED 0561-28W, Light
Forms-Five bow h -28w / or approved equivalent)
Supplying installation testing & commissioning of approx 20Watt Light Wide 55° Beam
Angle recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K
having efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum
housing, inbuilt electronic driver, suspension arrangement for pendent mounting through
suspension bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed
copper conductor cable and earthing etc. as required.(Any one make of REGENT(aston) -
LED 3138-20W, Endo Ledz -Glare less-19.8W, Light forms indus155-20W/ or approved
Supplying installation testing & commissioning of approx 10Watt Light Wide 38° Beam
Angle recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K
having efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum
housing, inbuilt electronic driver, suspension arrangement for pendent mounting through
suspension bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed
copper conductor cable and earthing etc. as required. (Any one make of REGENT(aston) -
LED 3138-10W, Endo Ledz -Glare less-8W, Light forms Leo99-10.2W/ or approved
Supplying installation testing & commissioning of approx 24Watt/mt (900∅) pendant LED
Down lighter Luminaire, IP 20 ,colour temperature 4000 to 6500 K having efficiency not
less than 100 lm/W, CRI ≥ 80 ,THD less than 20%, Extruded Aluminum / CRCA / Metal
146 housing / Thermoconductive plastic housing, inbuilt electronic driver, including 3 core 1.5 No. 3 39,014.91
sq.mm FR PVC insulated and PVC sheathed copper conductor cable and earthing etc. as
required.(Any one make of REGENT(volt) - 24W/m, Light forms- Moon band 40-25W/m/ or
approved equivalent)
Supplying installation testing & commissioning of approx 8Watt Light Wide 24° Beam Angle
recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K having
efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum housing, inbuilt
147 electronic driver, suspension arrangement for pendent mounting through suspension No. 6 6,303.79
bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed copper conductor
cable and earthing etc. as required. (Any one make of REGENT(aston) - LED 3138-8W,
Endo Ledz -Glare less-8W, Light forms Leo99-7.3W/ or approved equivalent)
Supplying installation testing & commissioning of approx 15Watt Light Wide 38° Beam
Angle recessed mounting type LED Luminaire, IP 20 ,colour temperature 4000 to 6500 K
having efficiency not less than 80 lm/W, CRI ≥ 80, THD ≤ 10%, extruded aluminum
housing, inbuilt electronic driver, suspension arrangement for pendent mounting through
suspension bracket including 3 core 1.5 sq.mm FR PVC insulated and PVC sheathed
copper conductor cable and earthing etc. as required. (Any one make of REGENT(aston) -
LED 3138-15W, Endo Ledz -Glare less-15W, Light forms Leo99-14.2W/ or approved
Supplying & erecting single phase approved make industrial exhaust fan suitable for
medium duty ring mounted low noise operation suitable for medium duty having following
149 dia size and maximum speed in RPM No. 1 3,937.99
[E] 450 mm dia 1400 RPM
Supplying & erecting electro galvanised G.I. wire micro mesh jali cover of grade
150 required size with suitable wooden frame duly fitted in wall outside of exhaust fan for insect Sq. Mtr 1.5 628.51
Total Carried Over to Summary
151 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. Kg. 5 77.70
Total Carried Over to Summary
Item no Item Description Unit Qty. Rate
Electrical Miscellaneous
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction
152 boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved Mtr. 30 23.06
manner as directed
Total Carried Over to Summary
ICT Distribution System For Data And Voice Infra
PVC Conduits & Accessories
Supplying and fixing of following sizes of medium class PVC conduit along with accessories
156.00 in surface/recess including cutting the wall and making good the same in case of recessed MTRS 33.00 32.06
conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories
in surface/recess including cutting the wall and making good the same in case of recessed
conduit as required.
CAT6A UTP Components for Data/LAN & Wi-Fi
Supply and laying of specified make UTP CAT6A LSZH cable in prelaid PVC conduits /
pipes / raceway, but without the cost of raceway or pipe. (The cable is to be drawn from
158.00 individual workstation/device/desktop area to the central communications/server room. MTRS 638.00 71.05
Terminations to be carried out in any intermediate wiring closets/telecom closets by way of
racks/MDF/IDF)_DATA, VOICE, CCTV Cabling as per technical specification etc. as
Supply, Installation, Testing & Commissioning of Single UTP CAT6A Tool less RJ-45 I/O
and RJ45 Information outlet with insertion cycle (in & out) upto 2500 times (I/O) of specified
make inclusive of termination of CAT6A cable at each IO at Equipment & Rack Side as per
technical specification etc. as required.
Supply, Installation, Testing & Commissioning of CAT6A UTP RJ-45 Patch Cords Solid
160.00 Conductor 1 mtr. for data (Hub Side)-Data, Number of Insertion upto 2500 Duty Cycle as EACH 34.00 318.15
per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of CAT6A UTP RJ-45 Patch Cords Solid
161.00 Conductor 2 mtr. for data (Hub Side)-Data, Number of Insertion upto 2500 Duty Cycle as EACH 34.00 344.66
per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of UTP CAT6 / CAT6A Gigabit Modular
Unloaded Patch Panel for 24 ports in 1U form factor as per the tender specifications, with
162.00 universal A/B labeling and 110 connector terminations on rear of panel allowing for quick EACH 2.00 3,976.88
and easy installation of 22 to 24 AWG cable.-Data includes Computer Point, CCTV, ACS,
CCTV, Wi-Fi as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Singlex Face Plate for mounting CAT6A
IO with required back box as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Duplex faceplate for mounting CAT6A IO
with required back box as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 19-inch 12 Port LIU, rack mounted , Fully
165.00 loaded with 2 X 06 Ports Adaptor Connector Panel & with Splice Tray, inclusive of all EACH 2.00 11,665.50
mechanical accessories with out pigtail, as per technical specification etc. as required.
Supply, Splicing,Testing & Commissioning/ Termination of LC-Style Pigtail, 9/125,
Singlemode, 1.5 meter, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of LC-LC single mode duplex fiber optic
patch cord 3mtr, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 15U (600W X 600D)MM Wall mount
closed rack with front glass door, fan tray on top, perforated rear doors, keyboard tray with
shelf. Casters & 2 nos vertical power strip with std, as per technical specification etc. as
Item no Item Description Unit Qty. Rate
Supplying , fabricating and installation of various sizes SS race way / junction
boxes/clamps/ hangers / enclosure for ELV Fixtures/ for cable trays / Base for Display
mounting / Flange for Display etc. made out of 14 gauge sheet/Angle/Flat/rod/ channel/box
section etc with all necessary accessories like bend, junction boxes, coupler, supporting
169.00 clamps, elbows, hardware, anchor fasteners complete with Cutting, welding, grinding, KGs 50.00 477.23
finishing necessory grouting,cementing, plastering etc.. All the necessary fabrication
required will be included in the scope of contractor. Scope also includes two coat of primer
and two coat of paining of each items on all the sides complete in all respect as instructed
by Architect / project in charge.
Total Carried Over to Summary
Cable Television Distribution System
Supplying and Laying of Un-Armoured RG 11 Co-Axial TV cable in prelaid conduit as per
technical specification etc. as required.
Supply, Installation, Testing and Commissioning of one television point to be done with
171.00 television outlet socket and box of the APPROVED make, as per technical specification EACH 3.00 152.10
etc. as required.Cat.|||
Total Carried Over to Summary
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02_Vol-I-B_SBD_GUDC_Works_GCC_Interior_UDUHD_AHM.pdf
03_Vol-II-Part-I_Tech_Spec_Civil_and_Make_Interior_UDUHD_AHM.pdf
04_Vol-II-Part-II_Tech_Spec_Electrical_and_Make_Interior_UDUHD_AHM.pdf
05_Vol-II-Part-III_Tech_Spec_ELV_and_Make_Interior_UDUHD_AHM.pdf
06_Vol-II_Part-IV_Gen_Tech_Spec_Civil_R_and_B.pdf
01_Vol-I-A_SBD_GUDC_Works_Tech_Interior_UDUHD_AHM.pdf
07_Vol-III_SBD_GUDC_Works_Price_Bid_Interior_UDUHD_AHM.pdf
08_Vol-III_SBD_GUDC_Works_Schedule-B_Interior_UDUHD_AHM.pdf
09_Vol-IV_Bid_Drawings_Interior_UDUHD_AHM.pdf
10_DMO_2941_01-Apr-2026_744.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .