Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹22.5 L+₹2.9 L (15.1%)Rejected-Finance | L2 | Rejected-Finance HIGHEST | |
| 3 | Rejected-Technical 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical Not Accepted as firm is not enlisted in category c(i) |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
24 Jun 2020, 6:00 pmClosed
SHRI TC SHISHODIYA, DCWE(C)
MULTAN LINE ARMY AREA JODHPUR-342010 (RAJ)
Repair/ Maint of Central AC Plants in Army area Jodhpur
2020_MES_348067_1
CWE(A) JODH-22 OF 2020-21
Open Tender
Civil Works
Item Rate
150 days
ARMY AREA JODHPUR
4 documents required · 4 mandatory
₹500
GE(ARMY) UTILITY
₹45,000
Yes
23 Feb 2021
28 May 2020
25 Jun 2020
28 May 2020
24 Jun 2020
12 Jun 2020
Amount
Material and Labour for repairing /servicing / cleaning complete of 120 TR capacity chiller unit of Voltas make complete with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge Note :- Servicing work of chiller unit to be done by the authorised representative of OEM. Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. All spares parts as required for repair /servicing shall be measured and paid separately under relevant item of Sch 'A'.
Material only for replacement of following parts/items suitable for 120TR capacity chiller unit of Voltas Make :- (i) Compressor oil CPI-120.
All as per item No 02 above but Temperature sensor as suit to existing. MCST100
All as per item No 02 above but Gas sensor type: as suit to existing
All as per item No 02 above but Dryer 3/8 make: denfoss
All as per item No 02 above but Solenoid switch as suit to existing.
All as per item No 02 above but LP/HP cut out switch suitable for existing AC plant cap 120TR Make :Denfoss/Indfoss
All as per item No 02 above but Water cooled chiller main controller circuit PCB Model No. ACEGWFVXR1201MLP2
All as per item No 02 above but Pressure gauge as per sample
Material and Labour for repairing and servicing /cleaning complete of 5 / 7.5 TR compressor unit with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories such as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire Satisfaction of Engr-in-charge Note:- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. All spares parts as required for repair/overhauling shall be measured and paid separately under relevant item of Schedule 'A'
Material only for replacement of following parts/items suitable for compressor 5 / 7.5 TR capacity open type unit of ACCEL Make :- (i) Piston
All as per item No 11 above but Piston Rings
All as per item No 11 above but Connecting Rod
All as per item No 11 above but Connecting Rod bearing
All as per item No 11 above but Gudgeon Pin
All as per item No 11 above but Head Spring
All as per item No 11 above but Compresser Bearing
All as per item No 11 above but Crank shaft
All as per item No 11 above but Oil Seal
All as per item No 11 above but Oil Ring
All as per item No 11 above but Oil Plate
All as per item No 11 above but Compressor Cylinder
All as per item No 11 above but Load/Unload assembly
All as per item No 11 above but Oil pressure valve
All as per item No 11 above but Suction Reed
All as per item No 11 above but Discharge Reed
All as per item No 11 above but Oil pump
All as per item No 11 above but Gasket Set
All as per item No 11 above but Oil filter
All as per item No 11 above but Fan belt
All as per item No 11 above but Temperature gauge digital type with switch and complete accessories
All as per item No 11 above but Pressure gauge digital type with switch and complete accessories
All as per item No 11 above but L.P. Switch
All as per item No 11 above but HP Switch
All as per item No 11 above but Oil switch
All as per item No 11 above but Oil Pressure Switch
All as per item No 11 above but Compressor oil
Material and Labour for repairing/servicing /cleaning complete of 22.5 TR compressor unit with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories such as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire Satisfaction of Engr-in-charge incl replacement of following parts/items suitable for compressor of cap 22.5 TR:- Note ;- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. All spares parts as required for repair /shall be measured and paid separately under relevant item of Sch 'A'.
Material only for replacement of following parts/items suitable for compressor 22.5 TR capacity open type unit of ACCEL Make :- (i) Piston
All as per item No 39 above but Piston Rings
All as per item No 39 above but Connecting Rod
All as per item No 39 above but Connecting Rod bearing
All as per item No 39 above but Gudgeon Pin
All as per item No 39 above but Head Spring
All as per item No 39 above but Compressor Bearing
All as per item No 39 above but Crank shaft
All as per item No 39 above but Oil Seal
All as per item No 39 above but Oil Ring
All as per item No 39 above but Oil Plate
All as per item No 39 above but Compressor Cylinder
All as per item No 39 above but Load/Unload assembly
All as per item No 39 above but Oil pressure valve
All as per item No 39 above but Suction Reed
All as per item No 39 above but Discharge Reed
All as per item No 39 above but Oil pump
All as per item No 39 above but Gasket Set
All as per item No 39 above but Oil filter
All as per item No 39 above but Fan belt
All as per item No 39 above but Temperature meter digital type with switch and complete accessories
All as per item No 39 above but Pressure gauge digital type with switch and complete accessories
All as per item No 39 above but L.P. Switch
All as per item No 39 above but HP Switch
All as per item No 39 above but Oil failure switch
All as per item No 39 above but Oil Pressure Switch
All as per item No 39 above but Compressor oil
Material and Labour for servicing complete of 5/7.5/10 TR compressor package type unit with replacement of worn out /unserviceable parts and re fixing the same after complete servicing with accessories such as nut, bolts, washers etc. including testing, commissioning complete to the entire Satisfaction of Engr-in-charge Note :- (i) Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. All spares parts as required for repair /servicing shall be measured and paid separately under relevant item of Schedule 'A'.
Material only for replacement of following parts/items suitable for 5/7.5/10 TR package type units against item no 66 Fan belt s for blower motor
All as per item No 67 above but Bearing of shaft of blower
All as per item No 67 above but Complete wiring Resetting of Package Unit
All as per item No 67 above but Dryer filter
All as per item No 67 above but Air filter of 5 / 7.5/10 TR package unit
All as per item No 67 above but Condenser fan blade suitable for existing unit
All as per item No 67 above but bearing of shaft
All as per item No 67 above but Air filter suitable for officer ward AC plant
All as per item No 67 above but LP switch suitable for existing AC plant cap 5/7.5/10 TR (Package type) Make :Denfoss/Infoss
All as per item No 67 above but HP switch suitable for existing AC plant cap 5/7.5/10TR TR (Package type) Make :Denfoss/Infoss
All as per item No 67 above but PVC Cylinderical type tank of cap 1500 ltrs
All as per item No 67 above but PVC Cylinderical type tank of cap 2000 ltrs
Replacement of reciprocating type sealed compressor of cap. 5 TR make : Copeland model number CR72KQM-TFM-233DM, 3 Phase, 380-420 Volts, 50 Hz, thermally protected suitable for existing AC plant complete including testing and commissioning as directed
Replacement of Scroll type sealed compressor cap. 5 TR make : Copeland model number ZR61 KC-TFD-501 Phase, 380-420 Volts, 50 Hz, thermally protected , Operating pressure H/L 27.0/20.0 bars suitable for existing AC plant complete including testing and commissioning as directed
Replacement of Scroll type sealed compressor cap. 13 TR model No. SZ185S4RC, 380-400 V, 50 Hz thermally protected systemvolume 31.0L at LP side and 2.0 L at HP side PS from 25 bar to 31.9 bar make Danfoss suitable for existing AC plants
S&F in repair, PCB assy complete with display model no SCR 33 TR (MPD) V4 type Delux HMI range 10/7/2 current range 5/30 A Aux supply 0-11VAC, 0-13VAC display model no. 33 TR HMI (5-30A) make Voltas including testing all as directed and specified by EIC.
S&F in repair, PCB assy complete with display Sl no DX-3LD-45 unit model no XWC35-039AR2 of rated cap 37.7 TR make Blue Star including testing all as directed and specified by EIC.
S&F in repair, PCB assy complete with display of package type AC plant of cap 5 TR make Voltas including testing all as directed and specified by EIC.
Servicing of Hot water Generator as per manufacturer norms of capacity 63 KW model No RC63, 3 steps any make complete as directed and specified by EIC.
S&F in repair, heating coil as per sample of hot water generator of capacity 63 KW model No RC63, 3 steps any make as per sample complete as directed and specified by EIC.
Material labour for replacement of following parts/items suitable for 22000/14000/4000 CFM capacity AHU unit of Make -Voltas:- (i) Contactor 4 pole 40Amps make -L&T
All as per item No 87 above but Contactor 4 pole 25Amps make -L&T
All as per item No 87 above but Pressure Gauge
All as per item No 87 above but Temp. Meter
All as per item No 87 above but Digital Amps meter
All as per item No 87 above but Fan belt for AHU as per existing.
All as per item No 87 above but Relay 14-23 Amps of existing make-L&T
All as per item No 87 above but Direct mounted actuator valve complete set 3"/2.5"/4"
All as per item No 87 above but Thermostat for AHU
Supply and fix in replacement of following spare parts for cooling tower motor of capacity 3 HP Make : Kirloskar/hindustan:- (a) shaft
All as per item No 96 above but outer casing
All as per item No 96 above but bearing
Disconnecting the electrical connection and taking down the burnt out Cooling tower motor of capacity 02/03 Hp from any location and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC. Note :- Contractor must ensure reinstallation of motor and make motor functional after rewinding within 48 Hrs of receiving the complaint. Any delay will be fined Rs 1000 per hour
Supply and fix in replacement of following spare parts for cooling tower motor of capacity 10 HP Make : Kirloskar/hindustan:- (a) shaft
All as per item No 110 above but outer casing
All as per item No 110 above but bearing
Disconnecting the electrical connection and taking down the burnt out Cooling tower motor of capacity 10 HP from any location and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC. Note :- Contractor must ensure reinstallation of motor and make motor functional after rewinding within 48 Hrs of receiving the complaint. Any delay will be fined Rs 1000 per hour
Material and labour for descaling of condenser after opening from both side and using the descaling compound and brushes with long iron rod to clean the deposition in side the copper tubes and check the water flow in side the tubes including replacement of gasket set, nuts and bolt all as directed by Engr-in-Charge. Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. Following capacity are (a) 120 TR AC Plant
All as per item No 114 above but 22.5 TR AC Plant.
All as per item No 114 above but 5 TR AC Plant.
All as per item No 114 above but 7.5 TR AC Plant.
All as per item No 114 above but 35 TR AC Plant.
Cleaning and washing cooling coil with caustic soda mixed water and removing all dirt, sand etc. from fins of cooling coil and clean and wash with pure water complete all as directed Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction and the following capacity are (a)120 TR AC plant
All as per item No 119 above but 22.5 TR AC Plant.
All as per item No 119 above but 5 TR AC Plant.
All as per item No 119 above but 7.5 TR AC Plant.
Material and Labour for cleaning, servicing of cooling tower with cleaning agent complete pipe lines, and FRP tank, greasing, servicing of cooling tower, motor and fan & make the necessary alignment Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction.for the following capacity are (a) 240 TR AC plant
All as per item No 113 above but 20/22.5 TR AC Plant.
All as per item No 113 above but 10 TR AC Plant.
All as per item No 113 above but 7.5 TR AC Plant.
All as per item No 113 above but 70 TR AC Plant.
Material and labour for replacement of unserviceable sluice valve flanged of class1.6 PN of 100 mm dia and necessary fittings
Material and labour for replacement unserviceable ball bearing of Cooling Tower including all necessary lathe works as required and greasing etc complete as per direction of Engr-in-Charge. Following capacity of (a) 240 TR
All as per item No 119 above but 20/22.5 TR
All as per item No 119 above but 10 TR
All as per item No 119 above but 7.5 TR
All as per item No 119 above but 70 TR AC Plant.
Material and labour for repair/overhauling of centrifugal monoblock pump set of 5/7.5 HP by opening Gland bush , studs, nuts & washers Ball bearing of pump set Remetling grinding and polishing of pump shaft to required size Gland packing ,replacement of pump bearings and making its proper alignment etc & refixing after repair all as directed .
All as per item No. 124 above but 10.0 HP
Disconnecting the electrical connection and taking down the burnt out motor of capacity 05 HP from any location and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC. Note :- Contractor must ensure reinstallation of motor and make motor functional after rewinding within 48 Hrs of receiving the complaint. Any delay will be fined Rs 1000 per hour
All as per item no 126 above but of capacity 7.5/10 HP
disconnecting the electrical connection and taking down the burnt out monoblock pumpset of capacity 05/7.5 HP from any location and transporting to workshop for repair, dismantling the pumpset & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting monoblock pumpset from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC. Note :- Contractor must ensure reinstallation of pumpset and make the plant functional after rewinding within 48 Hrs of receiving the complaint. Any delay will be fined for Rs 1000 per hour
All as per item no 128 above but of capacity 02/03 HP
Material and Labour for repair/servicing greasing etc of compressor motor capacity 80 KW of repair / replacement of Ball bearing of motor and Remetling grinding and polishing of motor shaft to required size all as directed refixing the same with existing compressor with proper alignment.
All as per item No 130 above but cap of motor 30 HP
All as per item No 130 above but cap of motor 7.5 HP
Material and Labour for replacement unserviceable sprinkler Assy of Cooling Tower complete all as directed. The following capacity of (a) 240 TR
All as per item No 133 above but 10 TR
All as per item No 133 above but 7.5 TR
All as per item No 133 above but 20/22.5 TR
All as per item No 133 above but 70 TR
Dismantling and taking out old butterfly valve and supply, installation, testing and commissioning of butterfly valve class-II heavy duty for discharge & liquid line of 80 mm dia
Dismantling and taking out old butterfly valve and supply, installation, testing and commissioning of butterfly valve class-II heavy duty for discharge & liquid line of 100 mm dia
Dismantling and taking out old gate valve and supply, installation, testing and commissioning of gate valve class-II heavy duty for condenser line of 40 mm dia
Dismantling and taking out old solenoid valve and supply, installation, testing and commissioning of solenoid valve class-II heavy duty for liquid line as per existing.
Supply & Charging Maffron gas R-22 at Centre type AC plant and Package type AC plant. Note -Leakage detection using Nitrogen gas if requred is deeemed to included in the quoted rate
Supply & Charging Maffron gas 134 A at Centre type AC plant . Note -Leakage detection using Nitrogen gas if requred is deeemed to included in the quoted rate.
Supply & Charging Maffron gas R 407 at Centre type AC plant . Note -Leakage detection using Nitrogen gas if requred is deeemed to included in the quoted rate.
Material and labour for replacement unserviceable fan blade of out door unit package type AC plant of cap 5 TR all as per Engr in charge
Material and labour for replacement unserviceable CT fan blade of cooling tower of cap 70 TR as per existing size.
Material and labour for replacement unserviceable CT fan blade of cooling tower of cap 10/7.5/20/22.5 TR as per existing size.
Material and labour for replacement unserviceable CT fan blade of cooling tower of cap 240 TR as per existing size.
Material and labour for replacement unserviceable CT fan blade of cooling tower of cap 70 TR as per existing size.
(a) Preparation of old painetd Surfaces of any description, over 10 cm in width or girth,not otherwise described of AC plant of different capacity as specified and directed by EIC
(b) Priming with red oxide, Zinc chrome surfaces of any description, over 10 cm in width or girth,not otherwise described of AC plant of different capacity as specified and directed by EIC
(c) Synthetic enamel (ordinary tint) (each coat) surfaces of any description, over 10 cm in width or girth,not otherwise described of AC plant of different capacity as specified and directed by EIC
Material and labour for replacement of cooling pad /Fills for cooling tower/ air cooling plant including complete fitting as existing at various instalations.
Supply and fix in replacement of strip heater 2.0 KW suitable for central type AC plant Make:- Dass Pas / Heat Master / Aristo.
M&L for elect control wiring of 5 to 10 TR package type unit of any Make complete with all accessoies and repair to cantol panel all as directed at site.
Disconnecting & Taking out old existing unserviceable current transformer of Amp meter of any description and Supply, fixing & testing round/ring type current transformer of ratio 100/5 Amp to 150/5 Amp, rated burden 5 VA and accuracy class 1.0 complete all as specified & directed. Make : AE/Rishab/ Meco/Enercon/L&T/BCH.
Disconnecting, dismantling & taking out old existing unserviceable cables of any description & in any position and supplying, fixing & testing new three core, PVC insulated, unsheathed copper conductor cables, size 50 Sqmm 3 core suitable upto 1100 Volts conforming to IS-694 complete all as specified & directed by Engineer-in-Charge. (Make : Finolex / Gloster / Polycab/Plaza)
All as per item No. 157 above but cable of size 16 Sqmm 3 core
All as per item No. 157 above but cable of size 10 Sqmm 3 core
All as per item No. 157 above but cable of size 6 Sqmm 3 core
All as per item No. 157 above but cable of size 4 Sqmm 3 core
Supply and fix in replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site.
Supply and fix in replacement of old U/S single Phase Preventer suitable for motor protection and making all incoming and out going electric connections complete all a specified and directed.type VSP2 Make : Minilec/Jepro.
Supplying and fixing in replacement of AC contactor 3/4 pole, 415 volts current rating 25 A and including making necessary electric connections and testing of circuit on full load complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
All as per item No. 164 but current rating 18 AMPs, 3/4 pole -ditto-. Make -Siemens/ or equivalent of ABB or C&S.
All as per item No. 164 but current rating 30 AMPs, 3/4 pole -ditto-. Make -Siemens/ or equivalent of ABB or C&S.
All as per item No. 164 but current rating 125 AMPs, 37 KW, 3/4 pole -ditto-. Make- BCH/ or equivalent of siemens or L&T.
All as per item No. 164 but current rating 45 AMPs, 4pole -ditto- make BCH or equivalent of siemens or L&T.
Taking out old unserviceable MCCBs up to 200 Amp rating and Supply and fixing for MCCB, 4 pole,415Volt, 16 KA including cable lugs of suitable size Make: L &T/ Schneider/Legrand, complete testing, commissioning complete to the entire satisfaction of Engr-in-charge, the following capacity of (a) 25 Amps.
All as per above Item no. 169 but current rating 40 Amps
All as per above Item no.169 but current rating 63 Amps
All as per above Item no. 169 but current rating 100 Amps
All as per above Item no.169 but current rating 125 Amps
S&F in repair of push button any type (Red or green colours as required at site at the time of execution) complete all as specified and directed.
Supply and fix in replacement of overload relay capacity 4.5- 6.5 Amp for motor protection making all incoming and outgoing electric connection complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
Supply and fix in replacement of overload relay capacity 10-14 Amp for motor protection making all incoming and outgoing electric connection complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
Supply and fix in replacement of overload relay capacity 13-19 Amp for motor protection making all incoming and outgoing electric connection complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
Supply and fix in replacement of timer for motor starter 0-30 sec./3-30 Sec making all incoming and outgoing electric connection complete all as specified and directed.Cat No-800 SD Make : Selec or equivalent in BCH /Angel
(a) Preparation of old painetd Eaves gutter and pipes any description, n. exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc) of AC plant of different capacity as specified and directed by EIC
(b) Priming with red oxide, Zinc chrome Eaves gutter and pipes any description, n. exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) of AC plant of different capacity as specified and directed by EIC
(c) Synthetic enamel (ordinary tint) (each coat) Eaves gutter and pipes any description, n. exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) of AC plant of different capacity as specified and directed by EIC
Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanized iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified & shown in electrical plate No.5 of MES SSR part-I connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including charcoal , salt funnel GI pipe 40 mm dia light grade up to to 7.5 mtr length ,all as directed at site.
Material and labour for Earthing strip , galvanised iron strip 30 x 6 mm , burried in ground or fixed to pole/ wall with saddles etc as specified and directed. Earth work if required shall be measured against respective item.)
Supply and fix nitrile insulation 20 mm thik for protective MS pipes of sizes 80/100mm dia wide overlapping with suitable fixing arrangements complete all as required & directed by Engr-in-Charge.
M&L for protective aluminium cladding with aluminium sheet of 24 gauge to exposed MS pipes of sizes 80/100 mm with suitable fixing arrangement by steel screws/packing arrangement to avoid ingress of climate effect complete all as required & directed by Engr-in-Charge.
Material and Labour for repairing /servicing / cleaning complete of hot water generator capacity of 115 KW, complete with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge Make: Emerald Enterprises. Note :- Servicing work of hot water generator unit to be done by the authorised representative of OEM. All spares and parts are required for repair /servicing are including.
Material and Labour for repairing/servicing / cleaning complete of Air Handiling Unit capacity of 22.5 TR, complete with replacement of worn out /unserviceable parts and rectify the leakages and reassembling the same after complete repair/leakages with accessories as nust, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge
All as per item No. 187 above but capacity of 7.5 TR
All as per item No. 187 above but capacity of 10 TR
Material and Labour for repairing/servicing / cleaning complete of Air Handiling Unit capacity of 14000 CFM, complete with replacement of worn out /unserviceable parts and rectify the leakages and reassembling the same after complete repair/leakages with accessories as nust, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge
All as per item No. 190 above but capacity of 22000 CFM
All as per item No. 190 above but capacity of 20750 CFM
All as per item No. 190 above but capacity of 13750 CFM
All as per item No. 190 above but capacity of 4000 CFM
All as per item No. 190 above but capacity of 12000 CFM
All as per item No. 190 above but capacity of 4200 CFM
Supply only Gland Packing size of 8 mm
Supply only Gland Packing size of 10 mm
Supply only Gland Packing size of 12 mm
S & F wall/ceiling mounting luminaries LED tube light fitting 1x 28 W 230V Enerty effecient T5 box type epoxy power coated CRCA sheet with electronic ballast bipin holder internally prewired complete with all accessories suitable for 1 x 28 watt LED tube light (Make :bajaj/ Surya/Havells
Supply and laying rubber insulating mat one side chequered size 2 mtr x 1 mtr x 20 mm suitable for LT .
Taking out old damaged Ac duct insulation and supply and fixing for duct insulation with Alluminium laminated Nitrile insulation of thickness 15 mm and including the following: (a) M & L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
Taking out old rusted alluminium cladding and Supply and fixing alluminium sheet of size 24 Gauge for cladding to exposed AC duct rectangular/ square duct made out of Hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolts, gasket, with support of angle iron of size 50mm x 50mm x 6 mm and appropriate sealant on longitudinal joints etc as specified.
Taking out old damaged Ac duct insulation and supply and fixing for duct insulation with resin bonded fiber glass wool roll of density 24 kg per cum, with factory laminated alluminium vapour barrier, thickness of insulation 40 mm and including the following: (a) M & L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
S&F in repair/replacement following unserviceble items of exhaust fan 450 mm sweep 1440 RPM - (a) shaft
All as per item No 205 above but Disconnecting the electrical connection and taking down the burnt out exhaust fan motor of any capacity from any location for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, and reinstalled at site complete all as specified and directed by EIC.
(c All as per item No 205 above but bearing
All as per item No 205 above but Body
All as per item No 205 above but Fan Blade
S&F in safety chart for electric shock multi-colour printingon a star paper of size150cm x90 cm MS square frame with all instructions Do's and Don'ts in both Hindi and English Language.
S&F single line diagram of different capacity of AC plant as directed of size 150cm x 120 cm muti-colour printing on a superior quality of 3M venyl on 3 mm foam sheet weather proof with line diagram printed both in English and Hindi and fitted with wooden frame with hanging arrangement.
S&F working diagram of different capacity of AC plant as directed of size 150cm x 120 cm muti-colour printing on a superior quality of 3M venyl on 3 mm foam sheet weather proof with working diagram printed both in English and Hindi and fitted with wooden frame with hanging arrangement.
S&F SOP chart for AC Plant 50*70 cm in size muti-colour printing on a 80 GSM map litho paper polyster film of 30 Micron thick on both side with electric shock and its management printed in both English and Hindi fitted with wooden frame and hanging arrangement.
S&F of sign board of steel body of size 150cm x 120 cm with 100 cm iron stand (leg) with high quality paint coated on both side and painting the capacity and locality of AC Plant as directed with installation on a PCC foundation complete as directed by EIC.
S&F in repair, drift eliminator for cooling tower of capacity 70 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, drift eliminator for cooling tower of capacity 240 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, drift Shaft for cooling tower of capacity 240 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, drift Shaft for cooling tower of capacity 70 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, water distribution system complete including GI pipes, Strainers, butterfly valve etc as per existing for cooling tower of capacity 70 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, water distribution system complete including GI pipes, Strainers, butterfly valve etc as per existing for cooling tower of capacity 240 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, FRP cooling tower body complete including base and provision of installation of body on base, commisioning and testing after installation with the satisfaction of Engineer in Charge for cooling tower of capacity 240 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
S&F in repair, FRP cooling tower body complete including base and provision of installation of body on base, commisioning and testing after installation with the satisfaction of Engineer in Charge for cooling tower of capacity 70 TR AC plant all as specified and directed by Engineer in charge. Make : Mihir/Delta
Material and labour for servicing complete of scroll type AC plant unit of capacity 70 TR make : Voltas/Bluestar including repair/replacement of all necessary spare parts complete all as specified and directed by Engineer -in Charge. Note : - All spare parts shall be measured and paid separately.
Material and labour for PID controller with all controll wiring and accessories complete all as specified and directed by Engineer -in Charge.
Supply only cooling tower cleaning chemical to avoid fungas/ Bacteria and Micro organism in water, Chemical shall be of superior quality and make should be as per IS specification.
M/s R K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .