Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrRejected-Finance | ₹5.0 Cr | L1 | Rejected-Finance Quoted amount is exorbitantly high when compared to the approved estimate |
Tender Value
Refer Docs
Closing Date
22 Jul 2022, 5:00 pmClosed
General Manager- Projects
Kochi Metro Rail Limited 4th Floor, JLN Stadium Metro Station, Kaloor, Kochi, Kerala-682017
Shifting of KWA Utilities in connection with Kochi Metro Rail Phase II- Laying 300mm DI, 250mm DI,160mm PVC and allied Works from JLN Stadium to Padivattom (Chembumukku Bridge)
2022_KMRL_492598_1
KMRL/PROC/TENDER/2022-23/020
Open Tender
Miscellaneous Works
Item Rate
180 days
Kochi
Please refer Tender documents.
21 documents required · 21 mandatory
₹23,600
Yes
Exempted
Kochi Metro Rail Limited
24 Feb 2025
30 May 2022
25 Jul 2022
30 May 2022
22 Jul 2022
13 Jun 2022
30 May 2022 - 7 Jun 2022
6 Jun 2022
Amount
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR)
Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals. NEW DATA (Prepared based on PWD SDB - Item No.1009
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered). Depth not exceeding 1.5m
Bailing out water with 5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete. NEW DATA (Prepared based on PHED SDB - Item No.1070
Engaging Coolie
Engaging Fitter ( grade 1)
Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 250 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.18 in DAR
Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 300 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.19 in DAR
Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 160 mm nominal outer dia pipes.
Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket: 250 mm dia pipes
Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket: 300 mm dia pipe
Labour for cutting C.I. pipe with steel saw. 300 mm diameter C.I. pipe
Dismantling C.I pipes including excavation and refilling trenches after taking out the pipes, manually / by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer - in- Charge: Above 150 mm dia upto 300 mm dia
Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 : Upto 600 mm dia
Supplying and conveying 150mm MS Flanged Taile piece suitable for 150mm CI D/F S/V and 160mm PVC Pipe
Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints: 150 mm diameter pipe
Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints: 250 mm diameter pipe
Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints: 300 mm diameter pipe
Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA
Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 150 mm diameter. Class II" Data derived from item no.18.31.3.2of DAR
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 250 mm diameter. Class I" Data derived from item no.18.31.5.1 of DAR
Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 300 mm diameter. Class II" Data derived from item no.18.31.6.2of DAR
Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 40 mm Single acting Air Valve Observed Data derived from item no.18.59.of DAR
Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 80 mm Double acting Air Valve Data derived from item no.18.59.2 of DAR
Interconnecting the existing 700mm CI Pipeline to newly laid 300mm DI Pipe line by using 700*300mm MS saddle clamp, 300mm MS Flanged taile piece,etc including the cost of materials, labour etc complete
Interconnecting the existing 300mm CI Pipeline to newly laid 300mm DI Pipe line by using 300mm MS double flanged bend, 300mm MS mechanical joint, 300mm MS Flange taile piece etc including the cost of materials, labour etc complete. (Mechanical joint fabricated by 10mm thick MS for suiting 300mm CI and 300mm DI pipe including rubber ring of suitable size, MS Flange 2nos, 12mm Bolt 12 nos(45 cm length)
Interconnecting the existing 250mm CI Pipeline to newly laid 300mm DI Pipe line by using 250mm MS mechanical joint, 250mm MS Flange taile piece etc including the cost of materials, labour etc complete. (Mechanical joint fabricated by 10mm thick MS for suiting 250mm CI and 300mm DI pipe including rubber ring of suitable size, MS Flange 2nos, 12mm Bolt 10 nos(40 cm length)
Interconnecting the existing 160mm PVC Pipe with existing 100/80mm AC pipe line by using 160*50mm saddle supplied by the contractor and placing in position, jointing with solvent cement and testing to the required test pressure, including cost of saddle clamp, adapter, and hire for tools labour charges, etc, complete.
Interconnecting the existing 160mm PVC Pipe with existing 110/90/75/63mm PVC pipe line by using 160*50mm saddle supplied by the contractor and placing in position, jointing with solvent cement and testing to the required test pressure, including cost of saddle clamp, adapter, and hire for tools labour charges, etc, complete.
Centering and shuttering including strutting, etc. and removal of form for: Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1. 5:3 ( 1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size
Shifting the public Hydrant/house connections with 20/25 mm PVC pipe from the existing line to the newly laid pipes at different places, including cost of materials, labour charges, etc complete but excluding earth work excavation
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil (Ref. Item No. 2.10.1 of DSR)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 1.50m to 3.0m All kinds of soil (Ref. Item No. 2.11 of DSR)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia.
Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia.
Supply of uPVC Pipe, IS 4985: 2000 , 6kg/cm2, 160mm Dia
Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 40mm
Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm.
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .