| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-Finance | L1 | Accepted-Finance L1 Bidder | |
| 2 | L2₹10.4 L+₹1.5 L (16.4%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹11.6 L+₹2.7 L (30.0%)Rejected-Finance EDOLIKUNNATH H CHENNAMANGALUR PO MUKKAM VIA CALICUT 673602 | KOZHIKODE | KERALA | 673602 | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹12.7 L+₹3.7 L (41.8%)Rejected-Finance MALIAKAL HOUSE ANGAMALY P O ERNAKULAM DIST PIN 683572 | ERNAKULAM | KERALA | 683572 | L4 | Rejected-Finance Not L1 Bidder | |
| 5 | L5₹15.2 L+₹6.2 L (69.4%)Rejected-Finance | L5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
9 Dec 2024, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Urgent painting and minor civil repair works at Central Computer Centre
2024_NITC_835362_1
Engg/D1/JE6/378/2024-25
Open Tender
Civil Works
Item Rate
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹24,000
Yes
10 Jan 2025
18 Nov 2024
11 Dec 2024
18 Nov 2024
9 Dec 2024
18 Nov 2024
Amount
WOOD AND P. V. C. WORK
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled ur panelled and glazed shutters 25 mm to 40 mm thick:
Float glass panes
5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Size of Tile 600x600 mm
ROOFING
Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).
Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately).
FINISHING
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives.
New work (Two or more coats applied @ 1.43 litre) 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Applying priming coat:
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
French spirit polishing :
One or more coats on old work
Finishing mangalore tiles with tile guard paint of required shade over old work (one or more coats applied at 1.79 ltr/10 sqm)
REPAIRS TO BUILDING
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Dismantling and Demolishing
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area beyond 3 sq. metres
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling PVC,CI or asbestos pipe with fittings and clamp including stacking the materials in Engineering unit store.
WATER SUPPLY
Providing and fixing Polyvinyl Chloride (PVC) pipes, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
110 mm nominal dia Pipes (4kg/cm2)
ALUMINIUM WORK
Providing and fxing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fxing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
STRUCTURAL GLAZING ALUMMINIUM COMPOSITE PANEL
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in-Charge. For payment, only the actual area of glass on face # 1 of the glas spanels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is includedin cost of relevent Item*).(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technica lsanctioning authority as per the site requirement.
PRAJEESH V K (BID ID -3133901)
E K IBRAHIMKUTTY (BID ID -3134239)
SIJU POULOSE (BID ID -3133078)
VINEESH E (BID ID -3133436)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .