Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC | L1 | Accepted-AOC Contract is awarded to M/s Mangesh Murlidhar Darwade | |
| 2 | L2₹39.9 L+₹79,785 (2.04%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 3 | L3₹40.0 L+₹91,700 (2.35%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 4 | L4₹40.6 L+₹1.5 L (3.94%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 5 | L5₹40.8 L+₹1.7 L (4.44%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest quoted rate |
| Sl No | Description | Qty | Unit | Ms. S.K. ASSOCIATES L4 | Maruti Abhiyantriki L2 | BHAVIN INFRA L5 | m/s shivam tools and equipment L6 | Mangesh Murlidhar Darwade L1 | M/s. Shahabad Enterprises L7 | M/s Swaroop Enterprises L3 | MS. G.A. CONSTRUCTION L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair/ maintainance/ servicing and checking thoroughly, defective centrifugal pump set of capacity 120 HP by dismantling of pump set at site and checking inspection and replacement of unserviceable spares as required or as directed.
Notes :- (a) Spares shall be measured and paid separately under relevant items as 'Supply only'.
(b) The work involves proper alignment after repairing, testing, recommissioning the pump set to the entire satisfaction of Engineer-in-Charge. | 2 | Each Job | 9,100 ₹18,200 | 8,800 ₹17,600 | 9,600 ₹19,200 | 8,000 ₹16,000 Lowest | 9,000 ₹18,000 | 9,500 ₹19,000 | 9,200 ₹18,400 | 9,100 ₹18,200 |
| 2.00 | All as per serial item No 1 but pump set of capacity 100/90 HP. | 5 | Each Job | 8,200 ₹41,000 | 7,900 ₹39,500 Lowest | 8,500 ₹42,500 | 8,150 ₹40,750 | 8,000 ₹40,000 | 8,600 ₹43,000 | 8,100 ₹40,500 | 8,250 ₹41,250 |
| 3.00 | All as per serial item No 1 but pump set of capacity 75 HP. | 10 | Each Job | 7,850 ₹78,500 | 7,000 ₹70,000 Lowest | 7,400 ₹74,000 | 7,000 ₹70,000 Lowest | 7,500 ₹75,000 | 7,650 ₹76,500 | 8,000 ₹80,000 | 7,600 ₹76,000 |
| 4.00 | All as per serial item No 1 but pump set of capacity 60 HP. | 7 | Each Job | 7,100 ₹49,700 | 6,850 ₹47,950 Lowest | 7,150 ₹50,050 | 7,100 ₹49,700 | 7,000 ₹49,000 | 7,250 ₹50,750 | 7,500 ₹52,500 | 7,150 ₹50,050 |
| 5.00 | All as per serial item No 1 but pump set of capacity 30 HP. | 3 | Each Job | 5,225 ₹15,675 | 6,000 ₹18,000 | 5,600 ₹16,800 | 5,120 ₹15,360 | 5,000 ₹15,000 | 5,250 ₹15,750 | 4,500 ₹13,500 Lowest | 5,125 ₹15,375 |
| 6.00 | All as per serial item No 1 but pump set of capacity 25 HP. | 2 | Each Job | 3,150 ₹6,300 | 4,000 ₹8,000 | 3,100 ₹6,200 | 3,050 ₹6,100 | 2,900 ₹5,800 | 3,850 ₹7,700 | 2,800 ₹5,600 Lowest | 3,000 ₹6,000 |
| 7.00 | Supply only gland sleeve for 25 to 120 HP pump set complete all as directed. | 12 | Each | 850 ₹10,200 | 1,000 ₹12,000 | 710 ₹8,520 | 710 ₹8,520 | 700 ₹8,400 | 600 ₹7,200 | 500 ₹6,000 Lowest | 550 ₹6,600 |
| 8.00 | Supply only gland plate with gland packing, CI, for 25 to 60 HP pump set including nuts and bolts complete all as specified and as directed | 12 | Each | 1,190 ₹14,280 | 1,500 ₹18,000 | 1,400 ₹16,800 | 1,220 ₹14,640 | 1,200 ₹14,400 | 1,100 ₹13,200 | 1,225 ₹14,700 | 1,000 ₹12,000 Lowest |
| 9.00 | Supply only gland plate with gland packing, CI, for 75 to 120 HP pump set including nuts and bolts complete all as directed | 17 | Each | 1,300 ₹22,100 | 2,000 ₹34,000 | 1,420 ₹24,140 | 1,420 ₹24,140 | 1,400 ₹23,800 | 1,500 ₹25,500 | 1,410 ₹23,970 | 1,100 ₹18,700 Lowest |
| 10.00 | Supply only water retaining (Deflector) ring for 25 to 60 HP pump set complete all as directed | 12 | Each | 315 ₹3,780 | 400 ₹4,800 | 380 ₹4,560 | 305 ₹3,660 | 300 ₹3,600 Lowest | 355 ₹4,260 | 320 ₹3,840 | 500 ₹6,000 |
Tender Value
₹40 L
EMD Value
₹40,000
Closing Date
1 Nov 2025, 6:00 pmClosed
Shri Milind Mulik, (AE QS and C)
Military Engineer Services, Garrison Engineer (South) Ahilyanagar - 414002
REPAIR / MAINT OF PUMPING MACHINERIES, CLEANING OF OH TANKS and UG SUMPS AND OTHER ALLIED MISC E/M WORKS FOR WATER SUPPLY INSTALLATIONS AT ACC and S AREA UNDER GE(S) AHILYANAGAR
2025_MES_734819_1
8273/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahilyanagar
Class D Cat a(ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahilyanagar
₹40,000
Yes
27 Dec 2025
11 Oct 2025
3 Nov 2025
11 Oct 2025
1 Nov 2025
25 Oct 2025
11 Oct 2025 - 18 Oct 2025
Amount
Repair/ maintainance/ servicing and checking thoroughly, defective centrifugal pump set of capacity 120 HP by dismantling of pump set at site and checking inspection and replacement of unserviceable spares as required or as directed. Notes :- (a) Spares shall be measured and paid separately under relevant items as 'Supply only'. (b) The work involves proper alignment after repairing, testing, recommissioning the pump set to the entire satisfaction of Engineer-in-Charge.
All as per serial item No 1 but pump set of capacity 100/90 HP.
All as per serial item No 1 but pump set of capacity 75 HP.
All as per serial item No 1 but pump set of capacity 60 HP.
All as per serial item No 1 but pump set of capacity 30 HP.
All as per serial item No 1 but pump set of capacity 25 HP.
Supply only gland sleeve for 25 to 120 HP pump set complete all as directed.
Supply only gland plate with gland packing, CI, for 25 to 60 HP pump set including nuts and bolts complete all as specified and as directed
Supply only gland plate with gland packing, CI, for 75 to 120 HP pump set including nuts and bolts complete all as directed
Supply only water retaining (Deflector) ring for 25 to 60 HP pump set complete all as directed
Supply only water retaining (Deflector) ring for 75 to 120 HP pump set complete all as directed
Supply only spilt linter ring, CI, for 25 to 60 HP pump set complete all as directed
Supply only spilt linter ring, CI, for 75 to 120 HP pump set complete all as directed
Supply only cartridge for bearing for 25 to 60 HP pump set complete all as directed
Supply only cartridge for bearing for 75 to 120 HP pump set complete all as directed
Supply only shaft sleeve, CI, for 25 to 60 HP pump set complete all as directed
Supply only shaft sleeve, CI, for 75 to 120 HP pump set complete all as directed
Supply only stuffing box (Throat), CI, for 25 to 60 HP pump set complete all as directed
Supply only stuffing box (Throat), CI, for 75 to 120 HP pump set complete all as directed
Supply only set of gasket for 25 to 60 HP pump set complete all as directed
Supply only set of gasket for 75 to 120 HP pump set complete all as directed
Supply only set of 'O' ring for 25 to 60 HP pump set complete all as directed
Supply only set of 'O' ring for 75 to 120 HP pump set complete all as directed
Supply only wear ring, for 25 to 60 HP pump set complete all as directed
Supply only wear ring, for 75 to 120 HP pump set complete all as directed
Supply only impeller, CI for 90/100/120 HP pump set complete all as directed
Supply only impeller, CI for 60/ 75 HP pump set complete all as directed
Supply only impeller, CI for 25/ 30 HP pump set complete all as directed
Supply only pump shaft CI for 90/100/120 HP pump set complete all as directed
Supply only pump shaft CI for 60/ 75 HP pump set complete all as directed
Supply only pump shaft CI for 25/ 30 HP pump set complete all as directed
Dismantling and taking down unserviceable electric motor of 90/ 100/ 120 HP capacity of pump set from foundation and transportation to workshop for repairing, opening and rewinding with new super enamelled copper insulated winding wire as per existing gauge of copper wire, winding with insulating material, varnishing, heating etc and reassembling, transporting back to site of work and installing on existing foundation including proper alignment and testing complete all as specified and as directed. Note :- All disturbed surfaces shall be made good to match the eixisting surfaces without any extra cost to the department.
All as per serial item No 32 but electric motor of 60/ 75 HP capacity of pump set complete all as directed.
All as per serial item No 32 but electric motor of 25/ 30 HP capacity of pump set complete all as directed.
S&F in repairs ball bearing suitable for 90/ 100/ 120 HP capacity pump including bearing checknut, press washer, shaft brass nut including taking out old unserviceable bearing all as specified and as directed
S&F in repairs ball bearing suitable for 60/ 75 HP capacity pump including bearing checknut, press washer, shaft brass nut including taking out old unserviceable bearing all as specified and as directed
S&F in repairs ball bearing suitable for 25/ 30 HP capacity pump including bearing checknut, press washer, shaft brass nut including taking out old unserviceable bearing all as specified and as directed
S&F in repairs ball bearing suitable for 90/ 100/ 120 HP capacity motor including cir clip and taking out old unserviceable bearing all as specified and as directed
S&F in repairs ball bearing suitable for 60/ 75 HP capacity motor including cir clip and taking out old unserviceable bearing all as specified and as directed
S&F in repairs ball bearing suitable for 25/ 30 HP capacity pump including cir clip and taking out old unserviceable bearing all as specified and as directed
S&F in repairs, coupling bushes with studs of existing type and size suitable for 25 HP to 120 HP pump set all as specified and as directed.
S&F in repairs, love-joy / flexible type coupling, made out of MS, complete suitable for 25 HP to120HP pump set, including rubber star bush/rubber bush with nut bolts, metal filling existing shaft of motor/ pump and re-grinding, making key slot etc and testing with zero level alignment complete all as specified and as directed.
M&L for repairs to foundation of motor pump set of 100/ 90/ 75/ 60/ 30/ 25 HP by removing and taking out pump motor from foundation by unscrewing the nuts bolts and keeping away, dismantling old foundation, providing new foundation of MS channel MC 75 to MC 150 size, angle section as required at site as directed and strengthing the foundation plate, tightening/ screwing with SS nut bolts, providing UPVC pipe for drainage of water and re-fixing of motor on foundation including welding at proper connections, replacement of foundation nut bolts, washers, with accurate realignment of motor with pump to avoid vibration and to provide smooth running of pump on full load, testing and commissioning complete all as directed. Note:- The quoted rate shall be deemed to be inclusive of all civil works including PCC 1:2:4, type B2 as in foundation and grouting work including necessary form work, plaster etc complete as directed.
S&F in repairs, Pressure gauge complete set with GI bend pipe, nipples, operating switch / valve of capacity 0-100 kgf/sq cm as per sample suitable for 25 to 120 HP pump set complete all as specified and as directed.
Supplying Water testing report from Govt. approved testing center which includes organoleptic and physical parameters to prove the potablity of water from any pump house and the water shall be taken jointly by the contractor and rep of Engr-in-Charge for testing of essential characteristics, bacteriological examination all as directed by Engineer-in-Charge.
S&F in repairs, single phase preventor, suitable for 100/90/75/60/25 HP pump set starter, 415/440 Volt, 50 Hz all as specified and as directed.
S&F in repairs, 3 pole power contactor, TYPE -MNX-95 conforming to IS Amp rating 95 Amps (MNX95) fixed in existing starter complete all as specified and as directed.
S&F in repairs, 3 pole power contactors, TYPE -MNX -70 conforming to IS Amp rating 70 Amps (MNX70) fixed in existing FASD starter complete all as specified and as directed.
S&F in repairs, spare contact kit and spare coil conforming to IS suitable for ML-4 starter complete all as specified and as directed.
S&F in repairs, spare contact kit and spare coil conforming to IS suitable for ML-6 starter complete all as specified and as directed.
S&F in repairs 3 pole power contactor ML-2, TP 32 Amps capacity suitable for operation on 415 Volts 50 Hz, AC supply complete all as specified and as directed.
S&F in repairs 3 pole power contactor ML-3, TP 40 Amps capacity suitable for operation on 415 Volts 50 Hz, AC supply complete all as specified and as directed.
S&F in repairs 3 pole power contactor ML-4, TP 70 Amps capacity suitable for operation on 415 Volts 50 Hz, AC supply complete all as specified and as directed.
S&F in repairs 3 pole power contactor ML-6, TP 110 Amps capacity suitable for operation on 415 Volts 50 Hz, AC supply complete all as specified and as directed.
S&F in repairs, spare contact Kit TYPE -ML 2, fixed in existing starter complete all as specified and as directed.
S&F in repairs, spare contact Kit TYPE -ML 4, fixed in existing starter complete all as specified and as directed.
S&F in repairs, spare contact Kit TYPE -ML 6, fixed in existing FASD starter complete all as specified and as directed.
S&F in repairs, spare coil TYPE -ML 2, fixed in existing starter complete all as specified and as directed.
S&F in repairs, spare coil TYPE -ML 4, fixed in existing starter complete all as specified and as directed.
S&F in repairs, spare coil TYPE -ML 6, fixed in existing starter complete all as specified and as directed.
S&F in repairs, Thermal Overload Relay TYPE -ML 2/3, fixed in existing starter complete all as specified and as directed.
S&F in repairs, ON load change over switch in sheet metal enclosures, 3 phase, 4 pole, 400 Amps capacity, 415 Volts including necessary accessories all as specified and as directed.
Dismantling and taking out unserviceable electric sumersible pump set 15HP capacity from borewell and transportation to and from workshop, for repairing and servicing by replacing unserviceable parts such as impeller, bushing , thrust bearing waterseal / coupling etc including re-installing and testing with proper alignment complete all as specified and directed. Note : SS coupling/ adapter shall be measured and paid separately as "Supply and fix"
S&F SS Coupling to connect DE and NDE ends of motor and pumps with locking pins suitable for 15 HP all as specified and as directed.
S&F SS Coupling / adapter, suitable to connect HDPE pipe to pump outlet with MS clips all as specified and as directed.
Dismantling and taking out unserviceable electric sumersible pump set 2 to 5 HP capacity from borewell and transportation to and from workshop, for repairing and servicing by replacing unserviceable parts such as impeller, bushing , thrust bearing, waterseal / coupling inclu lathe work etc and re-installing and testing with proper alignment complete all as specified and directed.
S&F in repairs, ON load change over switch in sheet metal enclosures, 3 phase, 4 pole, 200 Amps capacity, 415 Volts including necessary accessories all as specified and as directed.
M&L in replacement, earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI earth strip 32 mm x 6 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 40mm dia GI pipe, light grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
S&F in repairs, 4 Pole, MCCB, 400 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 250 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 200 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 125 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 160 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, LT panel CT coils as per exiting size and make complete all as specified and directed.
M&L for replacement of R Y B phase indicators complete set of make as per existing complete all as specfied and as directed.
S&F in repairs, PTFE Teflon Graphite gland packing rope of size 10mm/12mm/14mm all as specified and as directed.
Supply only bearing grease HP/BP superior quality all as specified and as directed.
Supply & filling, engine oil 20 W/ 40 turbo synthetic superior quality including taking out old oil all as specified and as directed.
M&L for 15mm bore GI tubing, medium grade, laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out, including excavation earthwork complete and taking out old pipes and fittings all as specified and as directed.
All as per serial item No 79 here-in-before but for 20 mm bore GI tubing.
All as per serial item No 79 here-in-before but for 25 mm bore GI tubing.
All as per serial item No 79 here-in-before but for 50 mm bore GI tubing.
All as per serial item No 79 here-in-before but for 100 mm bore GI tubing.
Supply and laying in repairs DN 150 mm bore ductile Iron pipe with spigot and socket ends, centrifugally cast, class K9, conforming to IS: 8329, ISI marked laid in trenches/ over supports, pressure testing after laying including styrene butadine rubber gasket joints, including excavation earthwork complete all as specified and as directed.
All as per serial item No 84 here-in-before but for 200 mm bore.
All as per serial item No 84 here-in-before but for 250 mm bore.
M&L for CI / DI fittings and specials such as Bends (any type, radius and angle), Tapers any type (straight, bend, increasing, decreasing or double socket etc.), Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot), Collars, Caps, Plugs, Connecting pieces one end flanged and other end socketed or spigot ends or all socketed / spigot ends etc, suitable upto 150 mm bore pipe including taking out old fittings complete all as specified and as directed.
All as per serial item No 87 here-in-before but for 200 to 600 mm bore pipe.
M&L for run lead joints suitable for 150mm bore dia pipe, spigot and socket ends complete and pressure testing all as specified and as directed.
All as per serial item No 89 but for 200 mm bore pipe.
All as per serial item No 89 but for 250 mm bore pipe.
M&L for cast iron body, ball type, foot valve, flanged of size 80mm bore as per IS -4038 including suitable flanges, nuts, bolts, washers and rubbber gaskets including dismantling and taking down old unserviceable foot valve all as specified & as directed.
All as per item No 92 but 100 mm size.
All as per item No 92 but 150 mm size.
Cleaning of area around OH tanks, UG sumps, water supply installations by removing of the existing vegetation (i.e. Small trees/ bushes/ plants/ grass, etc) and removing the same from premises all as specified and as directed.
M&L for chamber cover, fabricated out of angle iron of size 40mm x 40mm x 6 mm in framework embedded in PCC coping, 3mm thick MS sheet cover with flat iron 40mm x 6mm all around and diagonally and hinged to the angle iron frame work with locking arragement and handle, duly painted with two coats of anticorrosive bituminous paint over a coat of anticorrosive bituminous primer complete including taking down existing chamber cover all as specified and as directed.
M&L for dewatering the UG sump of 14,00,000 gallons capacity, cleaning with high pressure jet to remove all mosses, algae, dirt, deposits and other sediments, scrubbing of internal surface with steel wire brush and removal of dirty water with sludge machines / industrial vacuum cleaners and disposal of the same to a safe distance including , sterilizing the complete internal surface of the tank by using ISI mark, Grade-I bleaching powder / Liquid Chlorine, wash with fresh water, drying up and writing the words on external wall at visible place ''Military Engineer Services, Tank Capacity & Date of Cleaning'' using synthetic enamel paint in white colour over black background and letters of 50 mm height and 40 mm width complete all as specified and as directed. Location : Dhobi ghat pump house.
All as per serial item No 97 but UG Sump of 8,00,000 gallons capacity. Location : Bhingar Pump House
All as per serial item No 97 but UG Sump of 5,00,000 gallons capacity. Location : Dhobighat
All as per serial item No 97 but UG Sump of 2,50,000 gallons capacity. Location : Dhobighat Pump House
M&L for PVC netlon jallies with wooden battens of sectional area n exc 13 Sqcm, wooden beads n exc 75 mm girth duly fixed with nails, and fitted on top entry of over head reservoir and fixed to windows to prevent entry of birds/dirt particles all as specified and as directed.
M&L for taking down carefully, existing unservicable water level Indicator from OH tank/ UG sump and repair the same by replacement of steel wire 4mm dia (8 SWG), MS V shaped pully 3 Nos, PVC Float 01 Nos, MS indicator, scraping, cleaning and painting steel surfaces complete, marking levels with night glow radium paint and fixing in position and testing for proper function complete all as specified and as directed.
M&L for preparation of surfaces of old MS/ CI/ DI pipes and pumps and applying one coat of synthetic enamel paint all as specified and as directed.
Supply and laying in trenches or fixing on wall or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 50 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning including taking out existing cable alongwith protection covers complete all as specified and as directed.
Supply and lay DWC cable duct pipe 63 mm dia for laying of LT cables etc complete with all accessories all as specified and as directed.
Supply only calcium hypo chlorite, dry free flowing and free from lumps of following generic specification : (a) Chlorine - Min 65 % (b) Particle size ( passing through 1.70 mm IS sieve) - min 99.5 % (c) water insoluble matter - max 6% (d) calcium hydroxide - max 4% (e) Sodium chloride - 15% complete all as specifed and diected . Make : Any make approved by E-in-Cs Branch .
M&L for construction of valve pit/chamber of Internal dimensions 1200 mm x 1200 mm x 1200 mm, using PCC 1:4:8, type D-2, using 40mm graded stone aggregates for foundation, 23 cm thick brick wall built in cement mortar (1:4) ,15 mm thick rendering all around the brick work in cement mortar (1:6), 75 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregates in coping including necessary form work, 3 coats of white wash on rendered surfaces and on coping, 2 mm thick mild steel top sheet cover with frame made out of 40x40x6 mm angle iron, locking arrangement, including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including demolition of existing valve chamber and clearing the debris complete all as specified and as directed.
All as per serial item No 107 here-in-before but internal dimensions 900 mm x 900 mm x 900 mm
Maruti Abhiyantriki (BID ID -3464549)
M/s Swaroop Enterprises (BID ID -3464551)
Ms. S.K. ASSOCIATES (BID ID -3464214)
BHAVIN INFRA (BID ID -3464932)
m/s shivam tools and equipment (BID ID -3464901)
M/s. Shahabad Enterprises (BID ID -3464674)
MS. G.A. CONSTRUCTION (BID ID -3464879)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
BOQ_822811.xls
BOQ • 0.32 MB
8273Tenderdocuments.pdf
Tender Documents • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .