Loading…
Loading…
Tender Value
₹83.6 L
EMD Value
₹1.7 L
Closing Date
30 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GSU ELECT
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less: where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical contract license: - The contractor/firm should have valid electrical contractor license
6 conditions · 2 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part I of attached GCC-2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical TRD Work in connection with upgradation of DEMU maintenance facilites at DEMU shed Merta Road
GSU-ELECT-JU-06-2025-26R2
GSU-ELECT-JU-06-2025-26R2
Open
Works - General
8 Months
Jodhpur, Rajasthan
₹0
₹1.7 L
30 Mar 2026
6 Mar 2026
16 Mar 2026
111 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 83,63,124 | ||
| — | 160.00 | — | — | ||
| Concrete for foundation and plinth in all type of soil including hard / rocky soil (including excavation and supply of all material viz. sand, cement and ballast, padding etc.) | — | — | — | 12,54,880 | |
| — | 20.00 | — | — | ||
| Supply of rolled or fabricated and galvanized traction mast, TTC, Portals, AT masts, feeder mast, bridge masts, DA, SPS etc. | — | — | — | 28,51,740 | |
| — | 20.00 | — | — | ||
| Erection of rolled or fabricated and galvanized traction mast, TTC, Portals, AT masts, feeder mast, bridge masts, DA, SPS etc. | — | — | — | 2,21,940 | |
| — | 45.00 | — | — | ||
| Supply of single cantilever assembly for conventional OHE (without insulator) | — | — | — | 12,59,145 | |
| — | 45.00 | — | — | ||
| Supply of Stay and bracket tube Porcelain type insulators (CD 1050mm) for single bracket assembly. | — | — | — | 5,63,265 | |
| — | 45.00 | — | — | ||
| Erection of single cantilever assembly complete with insulator for conventional OHE | — | — | — | 1,23,120 | |
| — | 4.00 | — | — | ||
| Supply of three Pulley type Regulating equipment (Conventional type) with complete assembly excluding insulator & termination arrangement. | — | — | — | 2,86,416 | |
| — | 4.00 | — | — | ||
| Erection of three Pulley type Regulating equipment (Conventional type) with complete assembly | — | — | — | 42,468 | |
| — | 6.00 | — | — | ||
| Supply of Fixed Termination Anchor (FTA) standard arrangement | — | — | — | 58,824 | |
| — | 6.00 | — | — | ||
| Erection of Fixed Termination Anchor (FTA) standard arrangement | — | — | — | 15,198 | |
| — | 4.00 | — | — | ||
| Supply of materials for termination of single/ double conductor of OHE (without insulator) | — | — | — | 38,288 | |
| — | 4.00 | — | — | ||
| Erection of materials with insulator for termination of single/ double conductor of OHE | — | — | — | 7,148 | |
| — | 4.00 | — | — | ||
| Supply of section insulator assembly including core insulator (without cut-in insulator). | — | — | — | 3,08,712 | |
| — | 4.00 | — | — | ||
| Erection of section insulator assembly including core and cut-in insulator | — | — | — | 31,084 | |
| — | 2.00 | — | — | ||
| Supply, erection, testing and commissioning of 25 KV doublepole isolator (1600A).Supply | — | — | — | 2,87,258 | |
| — | 2.00 | — | — | ||
| Supply, erection, testing and commissioning of 25 KV doublepole isolator (1600A).Erection | — | — | — | 18,204 | |
| — | 6.00 | — | — | ||
| Supply of material for Copper jumper for DPI | — | — | — | 42,684 | |
| — | 6.00 | — | — | ||
| Erection of material for Copper jumper for DPI | — | — | — | 3,228 | |
| — | 2.00 | — | — | ||
| Supply of Earth Contact assembly for isolator | — | — | — | 17,520 | |
| — | 2.00 | — | — | ||
| Erection of Earth Contact assembly on isolator | — | — | — | 2,964 | |
| — | 10.00 | — | — | ||
| Supply of Guy Rod assembly complete. | — | — | — | 1,16,830 | |
| — | 10.00 | — | — | ||
| Erection of Guy Rod assembly. | — | — | — | 18,470 | |
| — | 10.00 | — | — | ||
| Supply of 9 Tonne porcelain cut in insulator | — | — | — | 52,450 | |
| — | 2.00 | — | — | ||
| Erection of 9 Tonne porcelain cut in insulator (including insulator testing) | — | — | — | 2,562 | |
| — | 4.00 | — | — | ||
| Supply of 'G' Jumpers and its fittings | — | — | — | 46,088 | |
| — | 4.00 | — | — | ||
| Erection of 'G' Jumpers | — | — | — | 9,820 | |
| — | 1.00 | — | — | ||
| Splicing and extension of anchor OHE | — | — | — | 8,952 | |
| — | 1.50 | — | — | ||
| Supply of OHE excluding catenary and contact wire | — | — | — | 38,484 | |
| — | 1.50 | — | — | ||
| Erection of OHE including catenary and contact wire | — | — | — | 38,085 | |
| — | 10.00 | — | — | ||
| Supply of material for single earth electrode with earth pit complete as per RDSO Drg. No. ETI/OHE/P/7020 or latest | — | — | — | 42,780 | |
| — | 10.00 | — | — | ||
| Erection of single earth electrode with pit as per RDSO Drg. No. ETI/OHE/P/7020 or latest. | — | — | — | 17,810 | |
| — | 80.00 | — | — | ||
| Supply of structure bonds | — | — | — | 70,160 | |
| — | 80.00 | — | — | ||
| Erection of structure bonds | — | — | — | 11,840 | |
| — | 40.00 | — | — | ||
| Supply of transverse (cross rail, inter track) bonds | — | — | — | 49,760 | |
| — | 40.00 | — | — | ||
| Erection of transverse (cross rail, inter track) bonds | — | — | — | 4,520 | |
| — | 40.00 | — | — | ||
| Supply of longitudinal bonds | — | — | — | 31,840 | |
| — | 40.00 | — | — | ||
| Erection of longitudinal bonds | — | — | — | 4,800 | |
| — | 2.00 | — | — | ||
| Preparation of as erected LOP | — | — | — | 10,842 | |
| — | 45.00 | — | — | ||
| Checking and preparation of SED | — | — | — | 34,020 | |
| — | 30.00 | — | — | ||
| Supply of 18mm copper solid bus bar | — | — | — | 92,130 | |
| — | 30.00 | — | — | ||
| Erection of 18mm copper solid bus bar | — | — | — | 18,420 | |
| — | 1.00 | — | — | ||
| Dismantling of Regulating equipment | — | — | — | 10,135 | |
| — | 2.00 | — | — | ||
| Dismantling of Guy rod and termination | — | — | — | 3,118 | |
| — | 10.00 | — | — | ||
| Dismantling of cantilever / bracket assembly | — | — | — | 18,010 | |
| — | 10.00 | — | — | ||
| Breaking of concrete foundation of mast, portal, TTC etc. | — | — | — | 18,220 | |
| — | 1.00 | — | — | ||
| Dismantling & removal of mast, portal, TTC and other small part steel | — | — | — | 10,388 | |
| — | 12.00 | — | — | ||
| Dismantling of mast by cutting. | — | — | — | 27,084 | |
| — | 2.00 | — | — | ||
| Preparation of Design & Drawings as per RDSO principle of OHE design &specification, Sectioning Diagram and Layout plan. | — | — | — | 30,306 | |
| — | 20.00 | — | — | ||
| Supply & erection of various types of enamel caution boards (approx.area in range of 500-1000 sq.cm.per board). | — | — | — | 6,360 | |
| — | 20.00 | — | — | ||
| Supply of enamel/retro reflective structure plate/boards for traction use(approx. area inrange of 1000-1200 sq.cm. perboard). | — | — | — | 21,840 | |
| — | 20.00 | — | — | ||
| Erection of enamel/retroreflective structure plate/boards for traction use (approx. area inrange of 1000-1200 sq.cm.). | — | — | — | 2,280 | |
| — | 5.00 | — | — | ||
| Supply of enamel/ retroreflective danger/ caution, unwired turnout, engine stop,sigma boards and other similar type of boards (approx. area in range of 1200-6000 sq.cm. per board). | — | — | — | 11,520 | |
| — | 5.00 | — | — | ||
| Erection of enamel/ retroreflective danger/ caution, unwired turnout, engine stop, sigma boards and other similar type of boards (approx. area in range of 1200-6000 sq.cm.). | — | — | — | 2,850 | |
| — | 4.00 | — | — | ||
| Supply of 25kV post insulator and all components such as pedestal cap, clamps, stud bolts etc. to support jumper/busbar | — | — | — | 44,652 | |
| — | 4.00 | — | — | ||
| Erection of 25kV post insulator and all components such as pedestal cap, clamps, stud bolts etc. to support jumper/busbar | — | — | — | 1,612 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDOC.pdf
ATTACHMENT
MergedACSall_compressed.pdf Merged ACS
ATTACHMENT
BOQandspecification.pdf
ATTACHMENT
MergedACSall_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .