Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹39.3 L
EMD Value
₹78,600
Closing Date
21 Oct 2026, 6:00 pm2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (AF) Bareilly
GE (AF) Bareilly (UP)-243002
SPECIAL REPAIR/ REPLACMENT OF CERTAIN BER COOLING APPLIANCES AT AF STATION BAREILLY UNDER GE (AF) BAREILLY
2026_MES_791945_1
GE(AF)/BLY/T-49 OF 2026-17
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
Class D and Category c(i)
8 documents required · 8 mandatory
₹500
GE (AF) Bareilly
₹78,600
Yes
30 Sept 2026
30 Sept 2026
23 Oct 2026
30 Sept 2026
21 Oct 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down of existing BER Air Conditioners of any type and 1.5/2.0 Ton capacity with sheet metal enclosure/ 15 Amp socket complete from site and to be deposited in the E/M store of GE AF Bareilly complete all as specified and directed. | 47 | Each Job | - | - |
| 2 | Taking down of existing BER Window/ Split Air Conditioners of any type and capacity upto 2.0 Ton from site and to be deposited in the E/M store of GE AF Bareilly complete all as specified and directed.
Note for item No. 1.00 and 2.00 : (i) No Refrigerant should be leaked from any AC during taking out and shifting to MES Store yard.
(ii) Technically qualified AC Mech (Skilled) shall remove the above Air Conditioners. | 2 | Each Job | - | - |
| 3 | M&L for wiring for circuit/submain wiring alongwith earth wire of 2x4.0 Sqmm + 1x2.5 Sqmm size ISI marked FRLS PVC insulated copper conductor, single core cable in surface/ recessed drawn into PVC non rigid concealed conduit medium grade ISI marked with all accessories all as specified. Note : Two runs of PVC copper wire and one run of earth wire with one run of PVC conduit shall be measured and paid as one length. | 300 | RM | - | - |
| 4 | M&L for single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified. | 49 | Each | - | - |
| 5 | Supply, installation, testing & commissioning of Hi wall Split type Air Conditioner of capacity 1.5 TR, working on single phase, 240 volts, 50 Hz AC, R-32 CFC free refrigerant with cordless remote control unit and inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 Star rating, inverter type (variable speed), EER 3.2 complete with 100% copper condenser coil including fixing of indoor and outdoor unit with necessary copper pipe connections including cutting, bending, brazing, insulation on pipe, PVC drain pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated multi-stranded copper cable complete all as directed by Engineer-in-Charge. [Make: Blue Star /Lloyd/ Voltas/ Carrier/ LG] | 27 | Each | - | - |
| 6 | Supply, installation, testing & commissioning of Split type Air Conditioner of capacity 2.0 TR, wall mounted type, working on single phase, 240 volts, 50 Hz AC, R-32 CFC free refrigerant with cordless remote control unit and inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 Star rating, inverter type (variable speed), EER 3.2 complete with 100% copper condenser coil including fixing of indoor and outdoor unit with necessary copper pipe connections including cutting, bending, brazing, insulation on pipe, PVC drain pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated multi-stranded copper cable complete all as directed by Engineer-in-Charge. [Make: Blue Star /Lloyd/ Voltas/ Carrier/LG]
Note for Item No. 5.00 & 6.00: (a) Power cable between indoor and outdoor unit, copper piping (5.0 mtr) with heat/ cold resistant nitrile rubber/ foam type insulation, iron stand powder coated for outdoor unit and drain pipe up to the ground level shall be deemed to be included in quoted rate of this item. (b) It is the responsibility of contractor to fill the blanks/ holes made for copper piping and drain system to install the ACs to match with the existing surface. | 20 | Each | - | - |
| 7 | Supply, installation, testing & commissioning of window type Air Conditioner of 1.5 TR capacity, working on single phase, 240 volts, 50 Hz AC, R-32 CFC free refrigerant with cordless remote control unit BEE 5 star rated, cooling capacity 4500 K Cal per hour etc complete all as directed by Engineer-in-Charge. [Make: Blue Star /Lloyd/ Voltas/ Carrier/LG] | 2 | Each | - | - |
| 8 | S&F for wall mounted voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for variation between 170 to 270 volts with UV/OV, accuracy +/- 2.5% of capacity 5 KVA complete all as specified and directed. Make:V GUARD/ VINITEC (ELECTRONIC LAB NEW DELHI)/ MICROTECH/ BLUE BIRD | 8 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tender49.pdf
Tender Documents • 0.78 MB
BOQ_887919.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .