Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.8 L+₹2.3 L (6.36%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹43.8 L+₹7.3 L (20.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹46.2 L+₹9.7 L (26.7%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
19 Dec 2021, 6:00 pmClosed
CWE AF Ambala
HQ CWE AF Ambala Ambala Cantt PIN-133001
REPAIR/MAINTENANCE/SERVICING/OVERHAULING OF HT OH LINE, HT EQUIPMENT, AIR BREAK SWITCH, HT PANELS, RELAYS, CT/PT, HT CABLES AND CONNECTED ITEMS IN TECHNICAL AND DOMESTIC AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2021_MES_479872_1
CWE/AF AMB/AMB-31/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Ambala Cantt
For enlisted in MES Class D and category b ii and for unenlisted refer NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Ambala
₹98,000
Yes
27 Jan 2022
5 Oct 2021
21 Dec 2021
5 Oct 2021
19 Dec 2021
5 Dec 2021
5 Oct 2021 - 18 Oct 2021
Amount
Supply, laying, jointing, testing and commissioning HT XLPE cable (heavy duty), 11000 volts (earthed), cross sectional area 95 Sqmm, 3 core, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking out/down of old unserviceable HT cable from existing site complete all as specified and directed.
Description all as per BOQ item No. 1.00 here-in-before but cross sectional area 120 Sqmm, 3 core.
Description all as per BOQ item No. 1.00 here-in-before but cross sectional area 240 Sqmm, 3 core. Notes for item No. 1.00 to 3.00:- (i) Cable shall be of manufacturing date not earlier than Jun 2021. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately. (iii) No straight through joint shall be permitted in less than single drum length. (iv) The contractor shall produce original purchase vouchers duly machine numbered alongwith excise duty gate pass of factory for verification and record. (v) Cable shall be tested in the presence of rep of Accepting Officer at the factory premises and by GE or by Representative of GE after laying in the trenches & before returning filling in the trenches.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for walls, shafts, manholes not exceeding 10 sqm on plan or for laying pipes/cables etc and getting out, in soft/loose soil complete all as specified & directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover , Class HVP type-1 with peak, size 300mmx180mmx40mm, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
Dismantling of ACSR or AAC conductors complete all as specified & directed.
M&L stay wire galvanized iron stranded of size 7/4.0mm including dismantling/taking down of old unserviceable stay wire complete all as specified & directed.
M&L cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia including dismantling of old existing complete all as specified & directed.
Re-stretching of GI rearth wire including binding on insulators with and including providing aluminium tapes complete all as specified and as directed..
Re-stretching of ACSR conductor with and including binding of sagged loose conductors, of any type fixed on HT poles, at any locations including tightening the cross arms complete all as specified & directed. Note: Three lines of ACSR conductor shall be measured as one length.
M&L ACSR conductor, steel reinforced any type (Weasel, Beaver, Ferret, Mink) including stretching on insulators with aluminium taps, jumping, binding on poles with minimum sag including binding wire, jointing sleeves, and PG clamps of suitable size complete all as specified and directed. Notes :- The quoted rates includes Jumper on cutout point, 2 pole/4 pole structure shall be provided with PVC sleeves .
M&L GI steel earth wire 4 mm dia on existing Steel/PCC poles including binding on insulators with aluminium tap, jumpering etc including dismantling/taking down/out old wire as existing at site complete all as specified and directed.
M&L jumpers of squirrel ACSR conductor 2 mtr long inlcuding stranded PG clamps in design of two Aluminium alloy with two or more galvanized steel bolts fixed at one end, the jumpers will be wrapped with PVC sleeves 15mm dia in different colour complete all as specified and directed.
S&F in replacement Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
S&F in replacement post insulator, 11000 volts grade for gang operated air breaker switch including necessary nuts, bolts & washers complete all as specified and directed.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
S&F in replacement Loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
Dismantling/taking down/out old unservieable air break gang operated switch from two/four pole structure, removing GOD including supply and installing Switch Air break gang operated, triple pole, for horizontal or vertical operation, mechanically operated, mounted on 12 insulators and steel frame with operating mechanism & operating rod of 25mm bore, medium grade GI pipe from ground level with & including locking arrangement & minumum 02 Nos. eye hook, 200 Amps current rating 11000 volts working pressure including making electrical connections to make it functional after testing complete all as specified and directed.
Description all as per BOQ item No. 21.00 here-in-before but 400 Amps current rating.
S&F in replacement male contacts suitable for 400 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers complete all as specified and directed.
S&F in replacement female contacts suitable for 400 amps rating vertical mounted gang operated air breaker switch 11000 volts grade including necessary nuts, bolts & washers complete all as specified and directed.
M&L in replacement GI pipe 80 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40mm x 3mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed .
Description all as per BOQ item No. 25.00 here-in-before but GI pipe 100 mm bore. Note for item 25.00 & 26.00 :- Excavation and earth work shall be measured and paid separately
M&L earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 32 mm x 6 mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe GI 20 mm bore, light grade including protection pipe GI light grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion at site including dismantling/taking out/down of old existing earthing any type complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to GI earth wire 4.0 mm upto 7.5 mtrs long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore, light grade including protection pipe GI light grade 40mm bore , wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in soft/losse soil and refilling pit chamber with PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in electrical plate No 3 of SSR part-I (2009), including testing on completion on site including dismantling/taking out/down of old existing earthing any type complete all as specified and directed. Notes for item 27.00 & 28.00 :- (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at No extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L stay assembly having stay rod dia 20mm complete with accessories as shown in electrical plate No. 1 including dismantling/taking down of old existing stay assembly complete all as specified and directed. Note :- (i) Loop type insulator, stay clamps, excavation and concrete shall be measured & paid separatel. (ii) The electrical plate No. 1 as shown in SSR Part-I.
S&F in replacement lightening arrestor (set of three), expulsion type,11000 Volt, 65 kilo amp discharge capacity with all fittings complete all as specified and directed.
M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white,with letters , figures and conventional skull and bones in signal red colour, fixed with MS clamps ,bolts and nuts, for HT of 25 cm x 20 cm size as per SSR Part-I complete all as specified and directed.
M&L in replacement true vertical steel tubular, swaged welded pole conforming to IS-2713 part II , type 410 SP 55, 11 metre long complete with mild steel base plate of 6 mm thick of size 300 X 300 mm, finial taper plug, cap, bolts, nuts, washer and screws hole of required size and Nos. for fixing cross arms including painting externally with two coats of aluminium paint over & including one coat of zinc oxide primer for exposed surface and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including provision of white & blue colour strips with fluorescent paint upto 1.5 mtr height & nubmering of pole complete all as specified and directed. Note:- Excavation, earth work and PCC shall be measured and paid separately.
Material and labour PCC 1:3:6, type C-2, using 40 mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete etc complete all as specified & directed.
Material and labour PCC 1:2:4, type B-1, using 20 mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified & directed.
Cleaning and preparation of surfaces of HT/LT steel tubular poles(any size) with emery paper, filling the voids with suitable filler materials and applying two coats of aluminium paint over & including one coat of zinc oxide primer to poles, cross arms, brackets, hooks, junction box, stay clamps with and including making blue & white strip 30cm wide (5 Nos) upto 1.5 mtrs from PCC coping and marking the numbering on poles with synthetic enamel paint complete all as specified and directed.
Cleaning and preparation of surfaces of HT/LT PCC poles(any size) with emery paper, filling the voids with suitable filler materials and applying two coats of cement base paint over & including one coat of primer to poles and applying two coats of aluminium paint over & including one coat of red oxide primer to cross arms, brackets, hooks, junction box, stay clamps , and making blue & white strip 30cm wide (5 Nos) upto 1.5 mtrs from PCC coping and marking the numbering on poles with synthetic enamel paint complete all as specified and directed.
S&F cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paint over & including one coat of zinc oxide primer including dismantling of old unserviceable cross arm as existing complete all as specified and directed.
S&F anti climbing device, spikes type fabricated out of MS bars ,round square and flat with and including providing required nuts ,bolts,washers etc., welding in two halves, made to shape, to suit the cross section of the pole duly painted with two coats of aluminium paint over & including one coat of zinc oxide including dismantling of old unserviceable climbing device as existing complete all as specified and directed.
Dismantling & disconnecting electric connections of underground HT,XLPE cable,11 KV upto 240 Sqmm, from both sides and locating the fault in cable with fault locating machine in the entire length, removing moisture from cable, charging the HT cable with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functional complete all as specified and directed. Note: The work will be executed after obtaining proper shutdown from main power house after liasoning with AGE(E&M).
S&F in replacement TNC switch of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and directed.
S&F in replacement cable route indicator made of cast iron & embedded HT cable on 5 mm thick plate of size 80 mm dia including grouting the lugs of suitable size, grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates block of size 150 mm x150mm x150mm in foundation including necessary form work complete all as specified & directed. Note: (i) PCC work including form work included in quoted rates. (ii) Steel surface shall be painted with two coat of synthetic enamel paint over & including one coat of zince oxide primer and quoted rated are deemed to be included for this aspect.
Supply and fixing in replacement closing coil assembly of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement tripping coil assembly of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement indicator bulb 20 watts, 1100 volts of make,specifications as exists at site, suitable for VCB 400 amps,11 KV including making necessary connections & testing complete all as specified and directed.
Overhauling of VCB by checking of complete system, detecting faults /defects, replacing defective spare parts, checking hardwares for tightness, clean & lubricate soring guide & guide bolts, checking the trip , closing coil plunger is moving freely, check the electrical contacts are clear intact, clean the insulators,checking the lock nut, tighening the mechanical parts, adjustment of trollys etc complete all as specified and as directed.. Note :- Accessories & spare parts shall be measured and paid seperetely under respective items and shall be of same make & model as per existing accescories.
Supply and fixing in replacement isolating contact assembly (set of 6 Nos.) of make, specifications as exists at site, suitable for VCB 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and directed.
Supply and fixing in replacement breaker phase barrier of make,specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement earthing contact assembly , of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement Drive link assembly with adjuster ( set of three) of make,specifications as exists at site, suitable for VCB 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and directed.
Supply and fixing in replacement Motor with gear assembly , single phase, 230 volts , of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and directed.
Supply and fixing in replacement Motor charged mechanisam assembly with close/trip coil & charging handle , of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement of base assembly suitable for VCB 11000 Volts,400 amps, of make, specifications as exists at site, including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement contact system for VD4, 400 A (12 finger), of make, specifications as exists at site, suitable for VCB/RMU 11000 Volts,400 amps rating 13.1 KA including making necessary connections & testing complete all as specified and as directed..
Supply and fixing in replacement potential transformer of fixed type,3 phase,3 limbs with HRC fuses mounted, of make, specifications as exists at site, suitable for VCB 11000 Volts,400 amps including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement digital ammeter with shunt suitable for VCB 11000 Volts,400 amps, of make, specifications as exists at site, including making necessary connections & testing complete all as specified and directed..
Supply and fixing in replacement Digital frequency meter with shunt suitable for VCB 11000 Volts,400 amps , of make, specifications as exists at site, including making necessary connections & testing complete all as specified and directed.
Supply and fixing in replacement of IDMT relay with numerical relay for VCB tripping system (3 OC + 01 earth fault & high set instantaneous protection in single unit) suitable for operation on 24 volt DC all as per model No CGI14N of CG or equivalent in Seimens/Hager/Scheneider complete all as specified and directed. Note :- Existing relay are IDMT type electromagnetic type hence any modification in the wiring & panel sheet enclosure required is deemed to be included in the quoted rates.
Supply and fixing in replacement epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 50/25/05 VA for 11 KV complete all as specified and as directed..
Supply and fixing in replacement epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 100/50/05 VA for 11 KV complete all as specified and as directed..
Supply and fixing Drop out fuse 5Amps to 20 Amps in existing GOD , at any location after taking down/out fuse as existing at site complete all as specified and directed.
S&F in replacement cable jointing kit for 11000 volt earthed grade, indoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm complete all as specified and directed.
S&F in replacement cable jointing kit for 11000 volt earthed grade, indoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11000 volt earthed grade, outdoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11000 volt earthed grade, outdoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11000 volt earthed grade, straight through, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11000 volt earthed grade, straight through, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm complete all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11000 volt earthed grade, straight through, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm to 300sqmm complete all as specified and directed.
S&F in replacement cable jointing kit for 11000 volt earthed grade, indoor/outdoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm to 300sqmm complete all as specified and directed.
Supply and fixing DC power pack, AC input 90 volts to 270 volts, battery-7 AH/24 Volts, 50 Hz, output voltage 26.5 VDC +/- 5 % V after taking down/out pack as existing at site complete all as specified and as directed.
Servicing of ACB 630/800/1200 Amps rating by disconnecting incoming & outgoing cables, overhauling the all spare parts, greasing etc with & including replacenment of worn out minor spare parts, tighening of all nuts, bolts etc complete all as specified and directed.
Disconnecting HT/LT cables & Earthing connections of burnt /defective transformer of capacity 500KVA to 630KVA, 11KV/433 volts, 3 phase, any make, from pole/floor mounted, taking down from site of installation carefuly with the help of cranes and transporting the same to workshop for repair, opening, draining out transformer oil, dismantling complete & taking out core assembly & removing burntout windings, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformer including core tank and cooling tubes, removal of damaged parts, dehydrating the core assembly, re-assembling after replacement of damaged parts of the transformer after repairs, making connections and filling dehydradated/fresh transformer oil and testing for all type of tests(routine test & full load test) including transportation back & reinstallation/connection of transformer at site complete all as specified and directed.
Description all as per BOQ item No. 73.00 here-in-before but transformer of capacity 300KVA to 400KVA.
Description all as per BOQ item No. 73.00 here-in-before but transformer of capacity 160KVA to 250KVA.
Description all as per BOQ item No. 73.00 here-in-before but transformer of capacity 50KVA to 150KVA. Notes for item No. 73.00 to 76.00:- (i) Spare parts shall be measured and paid seperately. All parts/components replaced shall be identical to those specified by original manufacturer. (ii) Winding shall be measured & paid separately. (iii) The draining of old transformer oil is deemed to included in quoted rates but filling new transformer oil and dehydration & refilling of old transformer oil shall be measured & paid separately. (iv) A Board of Officers shall be appointed by the Accepting Officer for ascertaining the repair work required in transformer and all inventory shall be prepared in presence of Engineer-in-charge & Contractor. (v) The labour factor of dismantling/taking out of old spare parts & winding are included in quoted rates.
M&L winding of transformer any capacity at HT/LT side with super enamelled copper wire of gauge & weight as exists, varnishing & drying by vaccum impregnating, provinding insulating material, fixing the coil in the position in core assembly and making connection as per original pattern complete all as specified & directed. Note: The quantity of winding shall be assesed by BOO.
S&F LT side stud of gun metal/brass of suitable size, make, specifications as exists for transformer of capacity 500KVA to 630 KVA with & including nuts, botls & washers etc complete all as specified and directed.
Description all as per BOQ item No. 78.00 here-in-above but for transformer of capacity 300KVA to 400KVA.
Description all as per BOQ item No. 78.00 here-in-above but for transformer of capacity 160KVA to 250KVA.
Description all as per BOQ item No. 78.00 here-in-above but for transformer of capacity 50KVA to 150KVA.
S&F defective /cracked HT/LT side bushes of size, make, specifications as exists at site to make the equipment functional complete all as specified and directed..
S&F HT/LT bushing rubber ring gasket set of size, make, specifications as exists at site to make the transformer functional complete all as specified and directed..
S&F transformer top gasket, cork sheet of transformer set of size, make, specifications as exists at site to make the equipment functional complete all as specified and directed.
S&F silicagel in sealed bag of make, specifications as exists at site complete all as specified and as directed.
Supply & filling transformer oil of dielectric strength not less than 60 BDV to comply IS-335 of 1993 complete all as specified and directed.
S&F PVC air breather of make & specifications as exist at site filled and with & including silica gel suitable for upto 100 KVA transformer complete all as specified and directed.
Description all as per BOQ item No. 87.00 here-in-above but 100KVA to 200KVA transformer.
Description all as per BOQ item No. 87.00 here-in-above but 250KVA to 500KVA transformer.
Dehydration/centrifuging & filling of transformer oil by means Ultra High Vaccum double stage machine to remove impurities from oil such as moisture, dirt, air and other gases at site of installation in running condition of transformer including testing the oil before and after centrifuging from top and bottom of transformer to achieve the BDV value 45KV(rms) at 2.5mm air gap complete all as specified and directed. Note:- Oil Test value record register shall be prepared in presence of AGE/JE and handed over the register to sub divn on completion of work.
Cutting/ Lopping of tree branches (any girth) upto any height and any type of trees in route of / along the running HT OH conductor 11000 volts lines using suitable T&P and removal of cut branches from site to distance exceeding 250 mtr complete all as specified and directed. Note :-The tree branches after cutting, shall be 2 mtr away from the outer conductor of OH lines.
Digging & taking out of HT XLPE cable loop of any size including excavation and returning filling after rectification of fault and providing of 11KV grade, heat shrinkable type cable joint kit suitable for indoor/outdoor type whereever required of 3.0 core XLPE armoured aluminium conductor cable of any size complete all as specified and directed. Note : (i)The respective end/straight joint will be measured and paid seperately in respective items of joint. (ii) The earth work in any type of soil is included in quoted rates.
Digging of HT XPLE cable of any size including excavation and returning filling and shifting/relying the same by providing straight through cable joint kit with addition of HT cable in and jointing material of 3.0 core XLPE armoured aluminium conductor cable of any size complete all as specified and directed. Note : (i) The respective cables and end/straight through joint kit will be measured and paid seperrately in respective items. (ii) Earth work in any type of soil is included in quoted rates.
M&L for checking of LT & HT side of transformer any rating and replacement of burnt or heated lugs/ Nuts & bolt, checking oil level, cheking silica gel, checking jumper and GOD and tightening if found loose complete for fully functional of transformer complete all as specified and directed.
M&L for calibration / servicing the RMU of any Nos. of ways with engineer/Technician of reputed company in sub Station of any make/ways of existing at site, checking and serviceing of all mechanical/electrical parts and replace it with minor parts i.e HRC fues 2 Amps, indictor lamp control wiring if found unserviceable all as per site requirement and make them 100% serviceable throughout the contract period complete all as specified and directed. Note: (i)The rates for changing of minor parts is deemed to be included in quoated rates. (ii) It is the contractor's responsibility to make the RMU 100% functional by calibration /servicing througout the contract period and the this aspect deemed to included in quoted rates.
For Credit Schedule refer tender documents.
Esha Engineers
R D Bansal
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .