| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L2₹16.0 L+₹64,215 (4.19%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹19.1 L+₹3.7 L (24.4%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance Not being lowest | |
| 4 | Rejected-Technical JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | - | Rejected-Technical Not Validated |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
1 Jun 2020, 6:00 pmClosed
CWE WELLINGTON
Headquarters, Commander Works Engineers, Wellington, Barraks-Post, The Nilgiris, PIN 643231
REPAIR TO TRANSFORMER INCLUDING DEHYDRATION AND ALLIED WORKS AND REPAIR/PERIODICAL SERVICES TO DG SETS INSTALLED FOR E/M INSTALLATIONS AT PANDGODE MIL STN TRIVANDRUM
2020_MES_335902_1
84874/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
TRIVANDRUM
E Class b ii Category
6 documents required · 6 mandatory
₹500
GE (ARMY) TRIVANDRUM
₹34,000
Yes
7 Jul 2020
21 Mar 2020
3 Jun 2020
21 Mar 2020
1 Jun 2020
18 May 2020
23 Mar 2020 - 30 Mar 2020
Amount
Supply and topping up of new insulating transformer oil (ISI marked) and filling after dehydration of transformer oil having di-electric strength not less than 60 KV complete all as specified and as directed.
Dehydration, filtration and topping up of transformer oil to achieve di-electric strength not less than 40 KV for the following transformers including testing of transformer oil after filtration complete all as specified and as directed. (a) Transformer 400 KVA-01 No (b) Transformer 315 KVA-01 No (c) Transformer 250KVA-01 (d) Transformer 200 KVA-05 Nos (e) Transformer 125 KVA-01 No (f) Transformer 100 KVA-03 Nos
Removing grass, bushes and creepers growing at transformer yard, LT panel board, two pole structures and four pole structures and, keep the yard area and sorrounding neat and clean complete all as specified and as directed.
S&F in repair MCCB, 4 pole, 100Amps rating, breaking capacity 25 KA, 415 volt in the existing feeder pillar box including any addition /alteration to the panel to accomodate the new MCCB making connections with 25x3 mm copper strip as required from main bus bars including necessary welding works, metal work for fixing base plate etc and connections complete all as specified and as directed. Make: Indo Asian Cat Part No.830052 or techno-commercially equivalent.
All as per item No 4 here in before, but 125 Amps, rupturing capacity 25 KA. Make: Indo Asian Cat Part No.830053 or techno-commercially equivalent.
All as per item No 4 here in before, but 160 Amps, rupturing capacity 36 KA. Make: Indo Asian Cat Part No.830115 or techno-commercially equivalent.
All as per item No 4 here in before, but 250 Amps, rupturing capacity 36 KA. Make: Indo Asian Cat Part No.830117 or techno-commercially equivalent.
All as per item No 4 here in before, but 400 Amps, rupturing capacity 36 KA. Make: Indo Asian Cat Part No.830176 or techno-commercially equivalent.
Disconnecting HT/LT connections of the pole mounted/ plinth mounted out door type/ indoor type transformer, opening up the top cover to carry out repairs at site, including draining out oil from the transformer in suitable container and to carryout the transformer for repair such as replacement of gasket, HT/LT side brass studs bushing, cork sheet, breather, temperature gauge, gate valve, silica gel and refilling the oil complete all as specified and as directed. Note: The materials required for repair/replacement has been measured and paid as supply only items cattered here in after.
Supply only new cork sheet gasket, 5 mm thick, superior quality on top cover plate of the transformer capacity 100 KVA to 315 KVA complete all as specified and as directed.
Supply only LT bush assembly, brass, with double check nuts, washers and oil seal all accessories without bushing insulators for transformer capacity 100 to 125 KVA complete all as specified and as directed.
Supply only LT bush assembly, brass, with with double check nuts, washers and oil seal all accessories with out bushings insulators for transformer capacity 200 to 315 KVA complete all as specified and as directed.
Supply only HT bush assembly, brass, with double check nuts, washers and oil seal all accessories without bushing insulators for transformer capacity 100 KVA to 125 KVA complete all as specified and as directed.
Supply only HT bush assembly, brass, with double check nuts, washers and oil seal all accessories without bushing insulators for transformer capacity 200 KVA to 315 KVA complete all as specified and as directed.
Supply only silica gel including cleaning of breather assembly complete all as specified and as directed.
Supply and spreading loose filling with stone aggregates of gauge 63 mm inside the fencing of two pole structure/ four pole structure transformer yard upto a layer thickness of 150mm complete all as specified and as directed.
S&F in repair lightening arrestor expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 Volts including brackets, clamps, nuts, washers and connecting to earth wire 4mm dia GI wire complete all as specified and as directed.
S&F in repair switch air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, having current rating upto 200 Amps for working pressure 11000 Volts with drop out type fuses (three numbers of 40 Amp capacity) including applying grease for male /female contact and replacement of burnt termination grips complete all as specified and as directed by the Engineer-in-Charge.
M&L for repair gang operated switch air break of any type/ capacity, servicing to the loading arrangement, applying grease to all joints for smooth operation including replacement of burnt male / female contact, tapping arrangements if any complete all as specified and as directed by the Engineer-in-Charge.
M&L for replacement for earthing galvanised steel earth plate electrode 600X600X6.00mm thick burried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate less than 1.5 mtr below normal ground level) connected to GI strip 25x4mm by means of bolts, nuts, check nuts, and washers, of galvanised iron or steel including GI pipe light grade 40 mm bore for protection of earth lead,GI funnel and wire mesh etc complete all as shown in Electrical plate no 5 of SSR 2009(part- I) including necessary excavation earth work, form work. earth pit of size 450X450X300 mm of PCC M-15 (Nominal mix) using stone aggregate earth pit cover of PCC and 20 mm bore light grade GI pipe for watering and charcoal dust, common salt, and connected to test point 7.5 mtr from earth pit including testing complete all as specified and as directed.
S&F in repair incoming/outgoing 11 KV feeder plates of size 30cm x 20 cm made out of 1.6mm thick mild steel sheet, vitreous enameled paint with letters written in local language and English including figures and fixed with MS clamp made out of FI 25x3mm duly painted with synthetic enamal pant, with bolts, nuts and washers etc complete all as specified and as directed.
M&L for disconnecting the HT electric supply, applying two coat of aluminium paint over a coat of red oxide primer including preparation of steel surface of all cross arms/channels angle iron bracing etc and preparation of surface of HT poles by removing flaking particles for smoothness and applying two coat of acrylic exteriors emulsion water proofing paint on PCC poles for HT PCC Two Pole structure complete all as specified and as directed.
All as per item No 22 here in before but for HT PCC four pole structure complete all as specified and as directed.
M&L for disconnecting the HT electric supply, applying two coat of aluminium paint over a coat of red oxide primer including preparation of steel surface of all cross arm/ channels angle iron bracings and steel tubular poles for HT Steel tubular Two Pole structure complete all as specified and as directed.
All as per ser item 24 here in before but HT Steel tubular Four Pole structure complete all as specified and as directed.
M&L for preparation of existing plastered surface and applying two coat of Acrylic exteriors emulsion water proofing paint on concrete poles and platform of transformer complete all as specified and as directed.
M&L for painting plinth/ pole mounted transformer, Scrapping/ cleaning of outer surfaces of transformer and spray painting with two coats of best quality super enamel synthetic paint over one coat of red oxide primer complete including writing of SM/MES No upto 400 KVA capacity transformer of any make/shape/size all as specified and as directed by Engr-In-Charge.
M&L for replacement of Synthetic insulation mat for electrical purposes of size 2mx1mx19mm thick complete all as specified and as directed.
M&L for replacement of Synthetic insulation mat for electrical purposes of size 2mx1mx12mm thick complete all as specified and as directed.
S&F in repair of HT Danger notice plate of size 20 x 15 cm, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made out of 25x3mm with bolts and nuts of approved size, complete all as specified and as directed.
M&L for preparation and scrubbing out rust surface of indoor/outdoor type LT panel board and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and as directed.
S&F in repair LT panel for 36 ORs sub station, installing, testing and commissioning, factory made and tested (including CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system with powder costed finish, front opening type,The panel shall be dust, weather and vermin proof, IP 65 class protection and made of CRCA MS sheet 3.0 mm thick for outer shell and 2 mm thick for inner shell having TPN Aluminium bus bars of rating 400 A supported on SMC insulators , bottom base channel of MS section not less than 100 mmx 50 mm x 5 mm thick , entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 nos earth stud, solid connections from main bus bar to switch gears with required size of copper bus bars and control wiring with min 1.5 sqmm PVC insulated copper conductor cable .The panel shall be with the following and mounted on suitable PCC foundation complete all as specified and as directed.
S&F as in repair Automatic Power Factor Correction (APFC) Panel 5 step for 3 Phase, 415 V & 50 Hz and system of capacity 50 KVAR with APFC relay (IPFC CS 1001) 1 CT, incoming MCCB of capacity 100 A, suitable contactors, MCB SP, MCB TPN, Indicators for RYB, bank ON/OFF, system internal wiring, capacitors (1x2KVAR,1X3 KVAR,2X5 KVAR,1X10 KVAR.2X15 KVAR) powder coated panel CPRI approved, IP 66 protection dust and vermin proof complete app as directed by Engineer-in- charge. Make- Havells or techno-commercially equivalent.
M&L for draining out used lubrication oil from the DG set engine, cleaning of chamber and supply and filling of new multigrade engine oil for the DG sets of various capacities installed under GE (Army) Trivandrum complete all as specified and as directed. NOTE: Flushing out sludge accumulated in the oil chamber to be done properly before filling the new oil. Make: Cat No. 82.050.10.0.20 of Koel care super genuine oil or techno-commercially equivalent.
M&L for carrying out scheduled maintenance service of the DG sets of 160 KVA through manufacturer service engineer including replacement of elements of fuel filters, engine oil filters and air filter with gaskets checking the engine for any leakages adjusting engine belt tension, topping up radiater coolent etc complete all as directed by Engr-in-Charge. NOTE: Engine oil/coolent required for servicing the DG set will be measured and paid seperatly under relenvant items of the schedule.
All as per ser item No. 35 above but for DG set of capacity 62.5 KVA complete all as specified and as directed.
All as per ser item No. 35 above but for DG set of capacity 40 KVA complete all as specified and as directed.
All as per ser item No. 35 above but for DG set of capacity 30 KVA complete all as specified and as directed.
All as per ser item No. 35 above but for DG set of capacity 25 KVA complete all as specified and as directed.
All as per ser item No. 35 above but for DG set of capacity 20 KVA complete all as specified and as directed.
M&L for repair/servicing of self starter including replacement of solenoid switch, rewinding of armature, carbon brush set, carbon brush holder and taping of field coil for the DG set of capacity 160 KVA complete all as specified and as directed.
All as per ser item No. 41 above but for DG set of capacity 20 KVA complete all as specified and as directed.
M&L for servicing/repair of charging alternator including replacement of diode, bush/bearing and varnishing of windings for DG set of capacity 160 KVA all complete all as specified and as directed.
All as per ser item No. 43 above but for DG set of capacity 25 KVA complete all as specified and as directed.
M&L for repair and calibration of fuel pump and injectors as per calibration procedure and norms including replacement of pump element, injector nozzles and O rings/washers etc for DG set of capacity 40 KVA complete all as specified and as directed.
All as per ser item No. 45 above but for DG set of capacity 30 KVA complete all as specified and as directed.
S&F in replacement indicator lamp LED type complete assembly with holder suitable for 28 mm dia hole complete all as specified and as directed.
Taking out existing unserviceable V belts (Poly V-belt) of 40 KVA DG set and S&F Poly V-belt of same size complete complete all as specified and as directed. Make: Cat No. 4H.1493.01.0.00 (HSN Code-40103999) of Kirloskar or techno-commercially equivalent.
Taking out existing U/S V belts of size XPA 1250 Cogged of 25 KVA DG set and S&F V-belt of same size complete complete all as specified and as directed. Make: Cat No. 4H.069.01.0.00 (HSN Code-40103290) of Kirloskar or techno-commercially equivalent.
Taking out existing U/S V belts of size B-47 1237 length of 20 KVA DG set and S&F V-belt of same size complete complete all as specified and as directed. Make: Cat No. 38.066.01.0.00 (HSN Code-40103999) of Kirloskar or techno-commercially equivalent.
S&F in replacement automatic voltage regulator (AVR) suitable for 160 KVA, 30 KVA & 20 KVA DG set including taking down the old UNSV one complete complete all as specified and as directed. Make: Cat No. 2H.811.32.0.00 (HSN Code-85030090) of Kirlosker Green (Model: TAVR-10) or techno-commercially equivalent.
S&F in replacement 3 phase voltmeter 0-500 volts 96mm square flush mounting digital type complete all as specified and as directed. Make: L&T/AE/MECO or techno-commercially equivalent.
S&F in replacement digital type, 3 phase ammeter 0-100/200/300/400 Amps CT operated with 96x96 mm square flush mounting type complete all as specified and as directed. Make: L&T/AE/MECO or techno-commercially equivalent.
S&F in replacement LT CT coil 400/300/200/100/5 amps complete all as specified and as directed. Make: AE/KAPPA/legrand/Schneider Electric or techno-commercially equivalent.
S&F in replacement of MCCB triple pole and neutral (four pole) 63 Amps, 415 volts, 50 Hz having adjustable thermal setting range 70% to 100% and fixed magnetic setting (Ics = 100% Icu) with breaking capacity 16 KA conforming to IS/IEC 60947-2 & IEC 60947-2 including dismantling of old unsv one and making incoming and outgoing connections to the new one complete complete all as specified and as directed. Make: Cat No. DPX³ 420013 of Legrand or techno-commercially equivalent.
All as per ser item No. 57 above but for 100 Amps with 16 KA breaking capacity complete all as specified and as directed. Make: Cat No. DPX³ 420015 of Legrand or techno-commercially equivalent.
Draining out completely radiator coolant of different capacity of DG sets by loosen drain plug and then tighten the drain plug, slowly feed coolant of superior grade into the radiator through the filler until radiator is full, squeeze the upper radiator hose 2/3 times after coolant reaches the filler neck, close the radiator cap, testing after refilling complete all as specified and as directed. NOTE: Use LEYPOWER Coolant 5000 pre mixed coolant. No need to add water. Make: Castrol/Servo or techno-commercially equivalent.
M&L for preparation of painted surfaces of the acquistic enclosure/DG sets of capacity 160 KVA DG set by scraping and removing rust and other objects and applying two coats of synthetic enamel paint of existing colour by spray painting over a coat of zinc chrome primer and marking SM/MES Nos and repairing and greasing door hinges and locks complete all as specified and as directed.
All as per ser item No. 60 above but for DG set of capacity 40 KVA complete all as specified and as directed.
All as per ser item No. 60 above but for DG set of capacity 30 KVA complete all as specified and as directed.
All as per ser item No. 60 above but for DG set of capacity 25 KVA complete all as specified and as directed.
All as per ser item No. 60 above but for DG set of capacity 20 KVA complete all as specified and as directed.
Supply and fix in repair turbo charger and removing old detoriated parts, by replacing new for smooth functioning of DG set capacity 160 KVA complete all as specified and as directed.
All as per ser item No. 65 above but for DG set of capacity 40 KVA complete all as specified and as directed.
All as per ser item No. 65 above but for DG set of capacity 25 KVA complete all as specified and as directed.
All as per ser item No. 65 above but for DG set of capacity 20 KVA complete all as specified and as directed.
Dismantling the fuel/diesel tank, clean the inside surface and strainer, removing old detoriated parts of pipe line from deisel tank to fuel filter, refixing the fuel tank after cleaning complete all as directed for DG set capacity 160 KVA complete all as specified and as directed.
All as per ser item No. 69 above but for DG set of capacity 62.5 KVA complete all as specified and as directed.
All as per ser item No. 69 above but for DG set of capacity 40 KVA complete all as specified and as directed.
All as per ser item No. 69 above but for DG set of capacity 30 KVA complete all as specified and as directed.
All as per ser item No. 69 above but for DG set of capacity 25 KVA complete all as specified and as directed.
All as per ser item No. 69 above but for DG set of capacity 20 KVA complete all as specified and as directed.
M&L for radiator cleaning after removing carefully the radiater assembly from the DG set and cleaning, brazing wherever required from the site and re assembling completely of DG set capacity 160 KVA complete all as specified and as directed.
All as per ser item No. 75 above but for DG set of capacity 62.5 KVA complete all as specified and as directed.
All as per ser item No. 75 above but for DG set of capacity 40 KVA complete all as specified and as directed.
All as per ser item No. 75 above but for DG set of capacity 25 KVA complete all as specified and as directed.
All as per ser item No. 75 above but for DG set of capacity 20 KVA complete all as specified and as directed.
Dismantling of all unserviceable electric wiring loom from the 20/25/30/40/62.5/160 KVA DG Set of any make connected between starting switch, self starter, dynamo and other sensing points and supply and fixing the new electric wiring loom as per existing with protected flexible conduit complete in all respect and testing for proper function of DG Set complete all as specified and directed
Dismantling of old/unserviceable exhaust gas piping of DG Set and supply and fixing the same of suitable dia welded black MS, B class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/rockwool, 50mm thick chicken wiremesh & aluminum cladding etc., as required as per specifications suitable for 62.5 KVA DG Set of any make complete all as specified and directed
Dismantling of old/detoriated canvas cloth inter connection between the radiator and the sound attenuator to avoid transmission of vibration from the DG set of 40 KVA capacity to the sound attenuator through the treated duct complete all as specified and directed.
M&L for overhauling of alternator by heating and varnishing rotor and stator assembly for getting proper IR value and reasseble the same of DG set capacity 160 KVA complete all as specified and as directed.
All as per ser item No. 83 above but for DG set of capacity 30 KVA complete all as specified and as directed.
Supply & spread loose filling with river sand inside the FOL store, cable duct in DG set room etc not exceeding 150mm thick layer including removing the old sand to a distance not exceeding 50 mtr from the starting point complete all as specified and as directed.
M&L for Earthing complete in replacement with copper earth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to glavanised earth lead of copper strip of size 20mm x 3mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia from earth plate to Panel and DG set and water pipe 20mm dia GI medium grade raised upto a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with two handles, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance not of MES Schedule Part-I of SSR-2009 exceeding 50 mtr testing complete all as shown in electrical plate No-3 including removing old one from site of work complete all as specified and directed. NOTE: (a) Earthing shall be provided as per IS:3043-1987. (b) Earthing shall be carried out 7.5 mtr apart from the building. (c) Rate for copper strip upto test point included in the quoted rate.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required 20 x 3mm copper strip including removing the old unserviceable one complete all as specified and as directed.
Supply of synthetic insulating (rubber) mat of 1m x 2m x 19mm size and laid infront of LT panel & DG set complete all as specified and directed by Engr-in-Charge.
Dismantling the old/detoriated battery terminal cables, supply and fixing new appropriate size battery terminal cable including hose clips, apply petroleum jelly on battery terminals, tighten the terminals and testing complete all as specified and as directed.
Supply and install in replacement of on load change over switch 415 volt AC, 50Hz in sheet steel enclosure, 4 pole of capacity 63 Amps, confirming to IEC-947-3 staggered terminals, site convertible fuse version, interchangeable dual shaft position with site convertibility, to be provided into existing panel including dismantling of old unsv one and making electrical connections new one complete all as specified and directed by Engr-in-Charge. Make: Cat No. ITAS0063 of Indoasian or techno-commercially equivalent.
SUPER COOL
rvelectricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .