SUPPLY INSTALLATION TESTING AND COMMISSIONING OF HVAC WORK AT KAIRALI THEATRE KOZHIKODE
2019_KSFDC_306169_1
3667/T2/19/KSFDC
Open Tender
Electrical Works
Item Rate
90 days
Kozhikkode
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,900
Yes
online
₹50,000
Yes
14 Jan 2020
4 Oct 2019
25 Oct 2019
4 Oct 2019
22 Oct 2019
4 Oct 2019
Amount
SPLIT / PACKAGE UNIT
Supply, Installation testing and commissioning of split/ Package air cooled Air-conditioners each complete with scroll compressor, air cooled condensor, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including MICRO-PROCESSOR CONTROL with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipments requirements with Micro- processor control panel for each machine. Tenderes to elaborate the features of Micro- processor panel. Control cabling, power cable of isolator to indoor units and earthing of units to be include. GI Paintes frame works for out door units & making good of civil works .Refrigerant shall be R 410. Price shall inclusive of installation, commissioning, Refrigerant piping as per Drawing.11 TR Ductable Split unit - Inverter type- Kairali Balcony
2.5 TR 4 way cassette-counter (3 mtr copper piping included in the machine)
Control cabling of package/Split units
REFRIGERANT PIPING
Liquid line - Refrigerant piping with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.
suction line - Refrigerant piping with 19mm thick nitrile rubber insulation and with glass cloth & foaster painting.
Drain Water Piping
Supply and fixing in position of condonsate drain water &indoor unit drain to the floor trap piping with 19 mm thick nitrile rubber insulation and with necessary fittings like elbows,tees and reducers etc.25 mm PVC
SHEET METAL WORK - Supply, fabricate, handle and erect factory fabricated GSS ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces slip on flanges etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specs. (only hitech supports shall be used) wall opening as good as same - Rectangular Duct
1. 0.63mm GSS ducting in sq.m.
2. 0.80mm GSS ducting in sq.m.
3. 1.00mm GSS ducting in sq. m.
4. 1.25mm GSS ducting in sq.m.
GRILLES & DIFFUSERS
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers of design to be approved (material : Al)supply air grille with vcd
return air grille w/o vcd
Factory made fresh air dampers with louvers and control lever.
DUCT DAMPERS
Supply, fix, balance, and commission louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, fixing arrangement etc.complete brass bushings
FIRE DAMPERS.
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & microswitch to shut of corresponding Ahu (including control cable.)
DUCT INSULATION & LINING
Thermal insulation supply & fixing of 9 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
Acoustic insulation supply & fixing of 10 mm thick armafoam insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3
Non ac area duct insulationsupply & fixing of 19 mm thick armacell insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3
ACCOUSTIC LINING OF PACKAGE UNIT ROOMS
Supply, installing and testing of accoustic lining of AHU rooms, walls and ceiling with 15 mm thick nitrile rubber with adhesive as per the recommendation of the manufacture with density 140-180kg/m3
EXPOSED ROOF INSULATION
supply & fixing of 13 mm thick class o nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 40-60kg/m3
Inspection of the existing package units, split Units & AHU (capacity as per existing basis of design) to ascertain the performance and making good of the same in working condition to the satisfaction of the client. Work includes gas charging , repair work of damages, insulation ducting, pc boards, switches, indicaton lamps etc.
Kairali Below Balcony - 7000 Cfm DX AHU, 2 Nos. & Condensing Unit
Kairali Balcony - 9000 cfm DX AHU, 1 No. & Condensing Unit
Sree - 9000 cfm DX AHU, 1 No. & Condensing Unit
Dismantling
Dismantling, removing and reinstallation of existing 2 x 4.5 TR floor standing split units to the new place advised by the client and making good of the same in working condition to the satisfaction of the client. Work includes gas charging, repair work of damages, pc boards, switches, indication lamps etc. include refrigerant piping 15 Mts. / unit
Dismantling, removing and reinstallation of existing 4 x 1.5 TR Hiwall split units to the new place advised by the client and making good of the same in working condition to the satisfaction of the client. Work includes gas charging, repair work of damages, pc boards, switches, indication lamps etc. include refrigerant piping 15 Mts. / unit
Removal of the existing ducting wherever not required and interconnecting new and existing ducting as per new design and keeping in place as directed by KSFDC
Digital Display unit
Digital display unit inside the theatre to display temperature inside the theatre with necessary control cable from unit etc for all theaters
Metal frame work for hanging 11 TR Split unit
AMC -NEW UNITS
Annual maintenance contract charges including spares , gas and consumbles for the above plant per year for 5 years on per ton basis and percentage increase every year for 4 years after warrenty period of 1 year. The frequency of servicing shall be one in 3 months every year for routine service and immediate on break down calls.1st year
2nd year
3rd year
4th year
AMC - OLD UNITS
Annual maintenance contract charges including spares , gas and consumbles for the above plantper year for 5 years on per ton basis and percentage increase every year The frequency of servicing shall be one in 3 months every year for routine service and immediate on break down calls.1st year
2nd year
3rd year
4th year
5th year
Blue Star Limited
MORNING STAR REFRIGERATION INDUSTRIES
Thermodyns Engineering
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_419799.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .