Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 CrAccepted-Finance | ₹3.3 Cr | 1 | Accepted-Finance Lowest bid |
| 2 | 2₹3.3 CrRejected-Finance VILLAGE POST NALGAON NARAYANBAGAR CHAMOLI UTTARAKHAND 246453 | CHAMOLI | UTTARAKHAND | 246453 | ₹3.3 Cr | 2 | Rejected-Finance Higher Bid |
| 3 | Rejected-Technical NEAR PWD COLONY LOHAGHAT CHAMPAWAT UTTARAKHAND | - | - | Rejected-Technical As Per Attach |
| 4 | Not Admitted-Fee/PreQual/Technical C O HOTEL VASUNDHARA PLACE KAILASH GATE MUNIKI RETI TEHRI GARHWAL | TEHRI GARHWAL | UTTARAKHAND | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Rakesh Chandra Bhardwaj L1 | SURAJ SHAH L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting (With out Dozer)
Excavation in hilly area in ordinary rock not requiring blasting by mechanical means without using Dozer including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. | 9,394.88 | Cum | 127.16 ₹11.9 L | 128 ₹12.0 L |
| 2.00 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications P.C.C. (1:3:6) | 2,370 | Cum | 7,395.48 ₹1.8 Cr | 7,470 ₹1.8 Cr |
| 3.00 | Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012, MORT&H Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2 mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge. | 2,300 | Cum | 2,179.81 ₹50.1 L | 2,201 ₹50.6 L |
| 4.00 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix 1:2:4 (Hand mixed) | 350 | Cum | 8,142.4 ₹28.5 L | 8,224 ₹28.8 L |
| 5.00 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. | 1,275 | Cum | 1,114.23 ₹14.2 L | 1,125 ₹14.3 L |
Tender Value
₹3.4 Cr
EMD Value
₹6.7 L
Closing Date
27 Feb 2026, 5:00 pmClosed
Suprintending Engineer,
Office of the Suprintending Engineer, IWC Rudrapra
Flood protection action plan in (Dhadharbagad) below Gram Panchayat Bursol of Development Block Tharali, District Chamoli.
2026_IRDCE_91981_2
06/SE/2025-26
Open Tender
Civil Works
240 days
Gram Panchayat Bursol
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
EE ID Tharali
₹6.7 L
Office of the Suprintending Engineer, IWC Rudrapra
29 Apr 2026
13 Feb 2026
28 Feb 2026
13 Feb 2026
27 Feb 2026
15 Feb 2026
13 Feb 2026 - 19 Feb 2026
20 Feb 2026
Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting (With out Dozer) Excavation in hilly area in ordinary rock not requiring blasting by mechanical means without using Dozer including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications P.C.C. (1:3:6)
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012, MORT&H Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2 mm, supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge.
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix 1:2:4 (Hand mixed)
Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
SBDDhadarbagar2.pdf
Tender Documents • 1.94 MB
DrawingDhadarbagar.pdf
Additional Documents • 0.30 MB
BOQ_108916.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid