Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 12 69 NEAR BLOCK OFFICE GAYATRI MANDIR LINE WARD NO 12 BIRSINGHPUR PALI BIRSINGHPUR PALI UMARIA MADHYA PRADESH 484551 UDYAM MP 50 0001263 | UMARIA | MADHYA PRADESH | 484551 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.2 L+₹1.1 L (21.8%)Rejected-Finance BEHIND GAYATRI MANDIR WARD NO 12 BIRSINGHPUR PALI MADHYA PRADESH 484551 | BIRSINGHPUR PALI | UMARIA | MADHYA PRADESH | 484551 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | KAMRAN KHAN L1 | ELECTRO ENGINEERING L2 |
|---|---|---|---|---|---|
| 1.00Item Description/ Heading : 1. Providing and fixing of NGR in L.T side of GEC make transformer, Andrew Yule make transformer and Brentford make transformer (all 315kVA 3.3kV/570V) in Katkona 1&2 Incline 2. Providing and Fixing of NGR and other control unit in LT side of 02 Nos Andrew Yule make TSU 315KVA, 3.3KV/570V and providing and Fixing of NGR unit in LT side and repairing of insulators and contacts in HT side of 01 no. GEC make TSU 315KVA, 3.3KV/570V installed at Pandavpara mine of Jhilimili sub area. | |||||
| 1.01 | 1. Providing and fixing of NGR in L.T side of GEC make transformer, Andrew Yule make transformer and Brentford make transformer (all 315kVA 3.3kV/570V) in Katkona 1&2 Incline - (a) Supply and fixing of NGR and Sensitive Earth Fault Relay, Single Phase Preventor, Short Circuit RElay etc. in Secondary Breaker of TSU | 3 | Nos | 43,000 ₹1,29,000 | 42,803 ₹1,28,409 Lowest |
| 1.02 | (b) Supply and fixing of Under Voltage Relay and Earth Fault Relay | 3 | Nos | 13,000 ₹39,000 Lowest | 19,000 ₹57,000 |
| 1.03 | © Supply and fixing of Test/ reset Push Button | 3 | Nos | 1,900 ₹5,700 Lowest | 2,900 ₹8,700 |
| 1.04 | (d) Complete overhauling and wiring of LT Chamber and HT Chamber | 3 | Nos | 2,323 ₹6,969 Lowest | 3,900 ₹11,700 |
| 1.05 | (e)Testing, Supervision and Labour Charge | 3 | Nos | 4,999 ₹14,997 | 3,900 ₹11,700 Lowest |
| 2.01 | 2. Providing and Fixing of NGR and other control unit in LT side of 02 Nos Andrew Yule make TSU 315KVA, 3.3KV/570V and providing and Fixing of NGR unit in LT side and repairing of insulators and contacts in HT side of 01 no. GEC make TSU 315KVA, 3.3KV/570V installed at Pandavpara mine of Jhilimili sub area. - (A) Providing and Fixing of NGR unit in LT side and repairing of insulators and contacts in HT side of 01 nos GEC make TSU 315KVA, 3.3KV/570V Transwitch Unit SI. No. NT - 613927250 deployed in Pandavpara Mine.(a) Repairing of through going insulator | 3 | Set | 33,000 ₹99,000 Lowest | 42,803 ₹1,28,409 |
| 2.02 | (b) Repairing of incoming terminal insulator | 6 | Set | 1,650 ₹9,900 Lowest | 3,000 ₹18,000 |
| 2.03 | © Repairing of outgoing terminal insulator | 6 | Set | 1,650 ₹9,900 Lowest | 3,000 ₹18,000 |
| 2.04 | (d) Repairing of isolator moving contact | 3 | Nos | 1,100 ₹3,300 Lowest | 3,000 ₹9,000 |
Tender Value
₹6.4 L
EMD Value
₹8,100
Closing Date
25 Apr 2025, 5:00 pmClosed
Staff Officer ENM
Office of the General Manager SECL Baikunthpur Area
1.Providing and fixing of NGR in GEC, Andrew Yule and Brentford make transformer in Katkona 1N2 Incline 2.Providing and Fixing of NGR in 02 Nos Andrew Yule and 01 no. GEC make TSU installed at Pandavpara mine
2025_SECL_333836_1
SECL/GM/BKP/ENM/eTender/25-26/ 02
Open Tender
Civil Works - Others
Item Rate
60 days
Baikunthpur
As per NIT
8 documents required · 8 mandatory
₹8,100
6 Aug 2025
7 Apr 2025
26 Apr 2025
8 Apr 2025
25 Apr 2025
8 Apr 2025
8 Apr 2025 - 14 Apr 2025
Amount
Item Description/ Heading : 1. Providing and fixing of NGR in L.T side of GEC make transformer, Andrew Yule make transformer and Brentford make transformer (all 315kVA 3.3kV/570V) in Katkona 1&2 Incline 2. Providing and Fixing of NGR and other control unit in LT side of 02 Nos Andrew Yule make TSU 315KVA, 3.3KV/570V and providing and Fixing of NGR unit in LT side and repairing of insulators and contacts in HT side of 01 no. GEC make TSU 315KVA, 3.3KV/570V installed at Pandavpara mine of Jhilimili sub area.
1. Providing and fixing of NGR in L.T side of GEC make transformer, Andrew Yule make transformer and Brentford make transformer (all 315kVA 3.3kV/570V) in Katkona 1&2 Incline - (a) Supply and fixing of NGR and Sensitive Earth Fault Relay, Single Phase Preventor, Short Circuit RElay etc. in Secondary Breaker of TSU
(b) Supply and fixing of Under Voltage Relay and Earth Fault Relay
© Supply and fixing of Test/ reset Push Button
(d) Complete overhauling and wiring of LT Chamber and HT Chamber
(e)Testing, Supervision and Labour Charge
2. Providing and Fixing of NGR and other control unit in LT side of 02 Nos Andrew Yule make TSU 315KVA, 3.3KV/570V and providing and Fixing of NGR unit in LT side and repairing of insulators and contacts in HT side of 01 no. GEC make TSU 315KVA, 3.3KV/570V installed at Pandavpara mine of Jhilimili sub area. - (A) Providing and Fixing of NGR unit in LT side and repairing of insulators and contacts in HT side of 01 nos GEC make TSU 315KVA, 3.3KV/570V Transwitch Unit SI. No. NT - 613927250 deployed in Pandavpara Mine.(a) Repairing of through going insulator
(b) Repairing of incoming terminal insulator
© Repairing of outgoing terminal insulator
(d) Repairing of isolator moving contact
(e) Repairing of isolator fixed contact
(f) Supply and fixing of NGR and Sensitive Earth Fault Relay with sensor unit including installation and other associated charges
(g) Supply and fixing of Under Voltage Relay and Earth Fault Relay
(h) Supply and fixing of Test/reset Push Button
(i) Complete overhauling and wiring of LT Chamber, Cable Entry Box and HT Switches
(i) Testing, Supervision and Labour Charge
(B) Providing and Fixing of NGR and other control unit in LT side of 02 Nos Andrew Yule make TSU 315KVA, 3.3KV/570V Transwitch Unit SI. No. TS -07/09 and 164195 (Total 02 Nos) deployed in Pandavpara Mine. - (a) Supply and fixing of NGR and Sensitive Earth Fault Relay, Single Phase Preventor, Short Circuit Relay etc. in Secondary Breaker of TSU
(b) Supply and fixing of Under Voltage Relay and Earth Fault Relay
(c) Supply and fixing of Test/reset Push Button
(d) Complete overhauling and wiring of LT Chamber, Cable Entry Box and HT Switches
(e) Testing, Supervision and Labour Charge
Total impact of GST for the purpose of CTC
ELECTRO ENGINEERING (BID ID -1148875)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .