Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC 19 PAOTA C ROAD JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.9 L+₹1.4 L (11.6%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 Jul 2023, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
REPAIR MAINT OF SOLAR WATER HEATERS AND ALLIED WORKS AT AF STN JODHPUR UNDER AGE EM, GE (AF) NO 02 JODHPUR
2023_MES_600937_1
8398/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (AF) No 02 Jodhpur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹30,000
Yes
21 Jul 2023
3 Jun 2023
3 Jul 2023
3 Jun 2023
1 Jul 2023
19 Jun 2023
10 Jun 2023 - 17 Jun 2023
Amount
S&F in repairs hot water steel water tubing, 15 mm bore, medium grade, galvanised, with all fittings such as bends, tee, short piece, connectors, back nuts, diminishing pieces, caps ,plugs and union etc., fixed complete to walls and ceilings or laid in floors including insulation with glass wool, wire-mesh hand aluminium cladding complete all as specified and directed.
All as per Srl item No 1.00 here-in-before but 20 mm dia bore.
All as per Srl item No 1.00 here-in-before but 25 mm dia bore.
All as per Srl item No 1.00 here-in-before but 40 mm dia bore.
S&F in repair 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 5.00 here-in-before but 20 mm dia bore.
All as per Srl item No 5.00 here-in-before but 25 mm dia bore.
All as per Srl item No 5.00 here-in-before but 40 mm dia bore.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. including taking out old unserviceable cable complete all as specified.
S&F in repair Rotational moulded polyethylene water storage tanks cap 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
S&F in repair Rotational moulded polyethylene water storage tanks cap 2000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
S&F in repairs Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe 25 mm dia (minimum weight 455 gms) complete all as specified and as directed.
S&F in replacement gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 14.00 here-in-before but 40 mm dia bore.
S&F in replacement Brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair 25mm bore stop valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F in repair 20mm bore bib tap standard of chromium plated, high pressure, screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repair Polyethylene (PE-AL-PE) 15mm dia bore composite pressure pipes including all crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.) fixed to walls and ceilings or laid in floors complete all as specified and as directed.
All as per Srl item No 19.00 here-in-before but 25 mm dia bore.
All as per Srl item No 19.00 here-in-before but 40 mm dia bore.
S&F sheet metal enclosure comprising with socket plug, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp including taking down complete all as specified and as directed.
S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amp including taking down all as specified and as directed.
S&F in replacement of stainless steel tank of 1000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed
S&F in replacement of stainless steel tank of 2000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed
M&L servicing and maintenance of complete solar water heater plant of capacity 1000 LPD installed at single/double story buildings including carrying out repair to minor leakage, brazing work, cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and re-fixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed.
M&L servicing and maintenance of complete solar water heater plant of capacity 2000 LPD installed at single/double story buildings including carrying out repair to minor leakage, cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and re-fixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed.
M&L disconnecting of hot water, cold water system complete and removing leakage of hot water tank by welding to tank and re-fixing the same complete in all respect and testing for solar water heater of capacity1000,2000 LPD complete all as specified and as directed.
S&F in repair Solar Flat Plate Collector (existing size) having made of copper absorber having 2 Sqm area including connected items as required at site to make it fully functioning complete all as specified and as directed by Engineer-in-charge.
S&F in repair gasket set for solar water heater panel suitable for 1000/2000 LPD capacity as per existing sample, including other connected items as required at site to make it fully functioning complete all as specified and as directed by Engineer-in-charge.
S&F in replacement non return valve 20 mm bore for iron pipes complete all as specified and directed by Engineer-in-charge.
M&L rubber hose pipe 20mm dia between hot water tank & collector including dismantling & taking out existing unserviceable rubber hose pipe complete all as specified and as directed.
S&F in repair heating element of capacity 3KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specified and as directed by Engineer-in-charge
S&F in repair heating element of capacity 2KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specified and as directed by Engineer-in-charge
S&F in replacement of thermostatic switch (ISI marked) of range 0˚C to 80˚C suitable for solar water heater as per existing sample complete all as specified & directed.
L C ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .