Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC | ₹2.0 L | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹4,618
Closing Date
6 Mar 2026, 3:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer PH Sub division Chavara
DEPOSITQWSS to Kollam Neendakara Panchayath-Deposit PWD - Shifting of Distribution lines of 160mm PVC at culvert near Mannathara temple and 110mm PVC line at culvert near sreyas in Ward 4, Neendakara Panchayath under PH section Chavara
2026_KWA_840914_1
WRD/KWA-CE(SR)/TR/26307/2025
Open Tender
Civil Works - Water Works
Percentage
60 days
Neendakara
Please refer Tender documents.
6 documents required · 6 mandatory
₹555
Yes
₹4,618
Yes
12 Jun 2026
26 Feb 2026
7 Mar 2026
26 Feb 2026
6 Mar 2026
26 Feb 2026
Temperory Shifting of pipe line 160mm and 110mm pipe line at culvert near Mannathara temple
OD185982/2025-2026:Dismantling G.I. / MS pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges: Above 40 mm nominal bore
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.98.214:Supply of PVC Pipe, 6kg/cm2, 110mm Dia.
100.98.216:Supply of PVC Pipe, 6kg/cm2, 160mm Dia.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
OD187051/2025-2026:Supply of 160 mm CIR Joint
OD187052/2025-2026:Supply of 110 mm CIR Joint
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
OD187047/2025-2026:Interconnecting the existing/newly laid 160 PVC line to the existing/newly laid pipe line after tracing out the existing pipe line,cutting and jointing with suitable specials so as to make a water tight joint,charging and testing,providing fencing,lighting watching and providing caution board, including all labour charges,cost of pipe and specials etc.complete as per the direction of dept. officers
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
OD192017/2025-2026:Interconnecting the existing110 PVC/AC pipe line to the newly laid pipe line after tracing out the existing pipe line,cutting and jointing with suitable specials so as to make a water tight joint,charging and testing,providing fencing,lighting watching and providing caution board, including all labour charges,cost of pipe and specials etc.complete as per the direction of dept. officers
100.60.5.1:Labour charges for attending boring point leakage / checking in the existing mains, including charges for earth work excavation in all kinds of soil, exposing the main, dismantling damaged pipe and specials as the case may be refilling the trenches with proper consolidation etc. complete as per the approved standards including charges for lighting, watching, providing caution boards, traffic control etc. complete but excluding cost of materials and cost of cutting of concrete / tarred / bituminous roads and as per the directions of the departmental officers.
100.60.7.2:Repair work for 1m to 2m length in 20 mm (3/4 inch) house connections, using 25mm Indian Standard Class 6 uPVC pipe and specials, including trenching and refilling in all kinds of soil, hire for tools, cost of consumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads and as per the directions of the department officers.
Temperory Shifting of 110mm pipe line near Sreyas culvert
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.98.214:Supply of PVC Pipe, 6kg/cm2, 110mm Dia.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
OD192031/2025-2026:Interconnecting the existing110 PVC/AC pipe line to the newly laid pipe line after tracing out the existing pipe line,cutting and jointing with suitable specials so as to make a water tight joint,charging and testing,providing fencing,lighting watching and providing caution board, including all labour charges,cost of pipe and specials etc.complete as per the direction of dept. officers
laying 150mm GI pipe lines at Mannathara culvert of size 3mx3m
OD179948/2025-2026:Supply of 150mm G.I. pipes of Class B category confirming to IS standards etc as complete
OD187447/2025-2026:Cost of GI specials such as 150mm GI threaded elbow etc as complete
100.12.11:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 150mm diameter nominal bore.
OD187393/2025-2026:Supplying and fixing specials, interconnecting GI pipe with existing PVC/AC pipe line including conveyance charges to site etc as complete as per direction of department officers
100.39.5:Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work: 150mm diameter pipe.
Laying 100 mm GI at Sreyas culvert of size 8m*5m
OD186211/2025-2026:Supply of 100mm GI Medium pipe-base rate as per the DsoR 2018
OD187448/2025-2026:Cost of GI specials such as 100mm GI threaded elbow etc as complete
100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
OD187449/2025-2026:Supplying and fixing of specials, interconnecting GI pipe with existing PVC/AC pipe line including conveyance charges to site etc as complete as per direction of department officers
100.39.3:Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work: 100mm diameter pipe.
Shifting the 110 mm PVC at the Cross drain portion
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.98.214:Supply of PVC Pipe, 6kg/cm2, 110mm Dia.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
OD192220/2025-2026:Interconnecting the existing110 PVC/AC pipe line to the newly laid pipe line after tracing out the existing pipe line,cutting and jointing with suitable specials so as to make a water tight joint,charging and testing,providing fencing,lighting watching and providing caution board, including all labour charges,cost of pipe and specials etc.complete as per the direction of dept. officers
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1417822.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.03 MB
NITNDA.pdf
Tender Documents • 0.59 MB
BOQ_1417822.xls
BOQ • 0.28 MB
Needakarapwd.pdf
PDF • 0.09 MB
codepondk.pdf
PDF • 0.10 MB
CorrigundumNDA.pdf
PDF • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].