| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹27.7 L+₹22,830 (0.83%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹28.5 L+₹98,305 (3.57%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹28.8 L+₹1.3 L (4.72%)Rejected-Finance | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹29.8 L+₹2.3 L (8.28%)Rejected-Finance 201 JITENDRA LODGE BUILDING 20 NEW JAGNATH PLOT RAJKOT | RAJKOT | RAJKOT | GUJARAT | L5 | Rejected-Finance NOT L1 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
10 Oct 2023, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
SPECIAL REPAIR TO ROOF TREATMENT,CERTAIN WINDOWS AND FLOORING OF SERVER ROOM OF BLDG NO.P-53 AT MIL STN JAMNAGAR.
2023_MES_619781_1
8009
Open Tender
Civil Works
Item Rate
274 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹58,000
Yes
3 Jan 2024
20 Sept 2023
12 Oct 2023
21 Sept 2023
10 Oct 2023
4 Oct 2023
Amount
Taking down all existing roof treatment incl. demolition of cement concrete padding/levelling course incl wire brushing and cleaning loose dust etc from surfaces of RCC roof incl flashing and juntion of parapet incl removal of debries outside of MOD land complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete in any description and in any position not otherwise specially provided and removal of debris out side MD Land complete all as specified and as directed by Engineer-In-Charge.
M&L Avreage 25mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course /padding with slope incl finished even and fair w/o using extra cement complete all as specified and directed by Engineer-In-Charge.
M&L 10 mm thick cement plaster in CM 1:3 mixed with WPC (liquid water proofing compound) on padding layer for roof treatment, surface finished even and smooth without using extra cement for roof treatment complete all as specified and as directed by Engineer-In-Charge. (Note:- WPC shall be measureded and paid seperately supply only)
Supply only Integral waterproofing compound
M&L for Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torching method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane cover including testing on completion complete all as specified and as directed by Engineer-In-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed by Engineer-In-Charge.
M&L Cement Concrete 1:2:4 (20 mm Graded Stone Aggregate) 40 mm thick, as in floors, etc, and finished the Cement Concrete Surfaces Even and fair with out using Extra Cement, complete all as specified and as directed by Engineer-In-Charge.
M&L Cement Concrete 1:2:4 (40 mm Graded Stone Aggregate) 100mm thick with using WPC, as in sub based of basement floors, etc and finished the Cement Concrete Surfaces Even and fair without using Extra Cement, complete all as specified and as directed by Engineer-In-Charge. (Note :- WPC will be measured and paid seperatly)
M&L 18-20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, incl 20 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-In-Charge.
S&F Coloured Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in floors & skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-In-Charge.
M & L Non skid coloured ceramic tiles 7-8mm thick area of each tiles exceeding .06 Sqm but not exceeding .11 Sqm, in floors etc. set and jointed in neat cement slurry mixed with water proofing liquid compound and pointed in white or coloured grouting chemical to match , over 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-In-Charge.
M&L Glazed ceramic coloured designer tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 0ver and including 10mm thick plaster in cement mortar 1:4 complete all as specified and as directed by Engineer-In-Charge.
S&F Powder coated aluminium anodised sliding window of 3 track, frame and shutters of section (a) Three Track Frame:- (i)Bottom - 20832 (ii)Top/side – 20831 (b) Shutter:- (i)Bottom – 20736 (ii)Top/Side – 20738 (iii) interlocke - 20737 or appropriate equivalent section fixed with 4.8 mm thick tinted sheet glass and rubber gasket, handles, locking arrangement and SS wire mesh 0.36mm dia of wire and average width of aperture 1.40mm, including making opening for handle & fittings, fixed with complete all as specified and as directed by Engineer-in-Charge. NOTE : (ii) Rates include all glazing/SS wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, etc (iii).comprising frames of (Jindal aluminium section or equivalent as specified) roller bearing, rubber beading, consealed lock etc
S&F in repairs Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-In-Charge.
S&F Framed work such as grills,gratings, such as gates etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-In-Charge.
S & F in Mild steel, plain, black sheet 1.6 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed by Engineer-In-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) each area exc 1.5 sqm but n.exc 4.0 sqm complete all as specified and as directed by Engineer-In-Charge.
S&F Powdr coated aluminium alloy door frame of weight 2.863/kg/rm and 12 mm thick toughened glass for door of any size and side portions of toughened glass fixed to wall / floor, joints sealed with clear silicon silicate gel to make water tight, incl necessary cleats edges with diamond cut including taper drilling to flush the screws / all fitting as required, floor door spring hinges, patch fitting top, bottom and sides, lock and necessary fancy type SS handles, spider joint, etc. all as specified, required at site specified by manufacturer and as directed by Engr-in-charge.
Dismantling of wall and ceiling boards( fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed by Engineer-In-Charge.
S&F False ceiling work comprising GI frame work of size 605 x 605mm, for seamless celling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx. 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2m length) of 0.55mm thickness having knurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long and 12mm thick minral fiber board 595x595 mm for acoustic purpose fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and as directed.
S&F 12mm thick mineral fiber tile of size 595x595 mm for acoustic porpuse on wall surface including necessary gride complete all as specified and as directed by Engineer-In-Charge.
M&L 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and complete all as specified and as directed by Engineer-In-Charge.
M&L 5 mm thick plain colour PVC prelam sheet in strips & channel feathered at the edges for fixing on solid PVC wall lining, insulated PVC Wall lining, and solid PVC partitions inclusive of solvent cement and fixing at site complete all as specified and as directed by Engineer-In-Charge.
Taking down of cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 5mm thick in CM 1:3 on ceiling to be finished even and smooth without using extra cement. complete all as specified and as directed by Engineer-In-Charge.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finishing the surface even and even smooth without using extra cement. complete all as specified and as directed by Engineer-In-Charge.
M&L 15 mm thick rendering in in two layers 5mm thick inCM 1:4, with using WPC over 10mm thick cement plaster in CM 1:6 on fair face of brick work/Stone or concrete surface to be finished even and smooth without using extra cemen (Note :a) Intergial WPC Compound shall be used in sencond layer,b) Intergial WPC shall be paid seperately on supply only complete all as specified and as directed by Engineer-In-Charge.
M&L for preparation and applying three coats of white wash on new plastered surface of celing complete all as specified and as directed by Engineer-In-Charge.
Preparation of newly plastered surfaces of wall incl sweeping clean with brush to remove loose dust, sand, etc and applying two coats of heavy duty waterproofing coat (Dr Fixit Wounderproof-1 or equivalent) by mixing water @ 25-30% to make slurry coating and allow 4 to 6 hrs time for drying up of first coat before application of second coat in perpendicular direction of first coat and further left to dry for 4 hrs complete all as specified and directed as per manufacturer instructions.
M & L for preparation of new plastered surface of wall and applaying two coat of oil bond distemper over a coat of primer over and inclunding 3 mm wall care putty complete all as specified and as directed by Engineer-In-Charge.
M&L Preparation of newly plastered surface and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L complete removal of existing treatment of wall and including rubbing with sand paper and making the surfaces smooth and applying two coats of oil bound distemper (oil emulsion), over a coat of alkali-resistant primer on walls complete all as specified and as directed by Engineer-In-Charge. NOTE: Distemper shall be applied with roller finish.
M&L for complete removal of existing treatment on ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-In-Charge.
Material and labour for complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc, the area of application should be cleaned thoroughly, remove all dirt, dust and uneven elements from the surface by washing and scraping and all the unevenness in the surface should be corrected by filling the exterior wallcare putty, surface should be sanded down with fine grade sand paper for smoothness applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces,all as per manfecturars instructions as directed by Engr-in-charge.
Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement but , clean loose rust from bars manually with brush . fixing mild steel welded fabric of weight exceeding 3.5 kg but n Exc 4kg /Sqm with existing bars or by welding on it after cutting the RCC to the sound bar if the existing bar is damaged (Incld provn S&F new TMT bar whereever required ). Applying eppoxy bonding agent and making good with polymer modified plaster and micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in any floor including form work complete all as specified and directed by Engr-in-charge.
Demolition of in lintel, chajja , manhole cover landing , slab, parapet stair case of cement concrete reinforced simillar suspended works and removal of debries out side MD land complete all as specified and as directed.
M & L RCC nominal mix 1:2:4 type B1 using 20mm graded aggregate as in Chajjas, parapet etc including necessary formwork complete all as specified and as directed by Engineer-In-Charge.
S & F TMT steel bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-In-Charge.
Taking down 20 mm bore steel tubing /PVC pipe and connections, including removal to out side MD Land complete all as specified and as directed by Engineer-In-Charge.
supplying and laying of 20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End plugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including CI 'P' or 'S' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish with and including and PVC flushing pipe, 32 mm dia complete all as specified and as directed by Engineer-In-Charge.
S & F in repairs PVC low level flushing cistern 10 litres capacity valve less symphonic action type, ISI Marked white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S/F in repairs vitreous china wash basin coloured ovel type including waste type etc complete but excluding pillar taps.(Make Hindware Cat No 10017 or equalant ).
S&F 15 mm dia brass chromium plated pillar tap, Swan neck,fancy type with or without lettered 'Hot' or 'Cold' ,with long screwed shanks and fly nut, capstan head, screwed for 15mm dia pipe all as directed.
S&F vitreous china urinals,flat back of size 465mmX355mmX 265mm, Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and Union for discharge pipe.white with grating and union for discharge pipe including connecting to waste pipe complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs fancy type CP bib taps, 15 mm bore with crutch or , screwed down complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs angle cock 15 mm bore cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions.
S&F 75 mm dia PVC (SWR) Nahani trap plain with grating incl jointing with solvent cement complete all as specified and directed by Engr-in-charge
S&F 75 mm dia PVC(SWR) pipes single stacked in any length laid in floor /wall complete all as specified and directed by Engr-in-charge
S&F 110 mm dia PVC(SWR) pipes single stacked in any length laid in floor / wall complete all as specified and directed by Engr-in-charge
M&L 110mm dia.PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to walls as rain water pipes all as specified and directed.
S&F in repair PVC(SWR) bend any radius, 110 mm dia complete all as specified and as directed by Engineer-In-Charge.
S&F in repair PVC(SWR) bend any radius, 75 mm dia complete all as specified and as directed by Engineer-In-Charge.
S&F 75 mm dia PVC(SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed by Engr-in-charge
S & F Grating doom 100mm dia of PTMT(Minimum weight 25gms) complete all as specified and directed by Engr-in-charge
S & F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed by Engr-in-charge
M&L 32mm dia waste fittings for pipe, brass chromium plated for glazed ware sinks, basins, etc and fly-nuts, flange end bedded in red lead cement and otherend fixed complete all as specified and directed by Engr-in-charge
S&F in repairs 32 mm bore PVC waste pipe with fittings of approved make suitable for WHB, Urinals etc complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m depth for foundations, sewage lines etc and n.exc 10 Sqm on plan for manholes and getting out in soft/loose soil complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m from starting point.
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exc. 25 cm depth as in any type of soil complete all as specified and as directed by Engineer-In-Charge.
Demolition and breaking up any sewage drain pipe not exceeding 150mm bore dia set in cement mortar including haunching as directed by EIC.
M&L for cement concrete bedding and haunching against the sides of pipes after they are laid to 150mm bore drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates) laid to falls including packing under, and tested, complete all as specified and as directed by Engineer-In-Charge. NOTE :- Pipe shall be measured and paid separately).as in repairs.
S&F DWCPE (SN8) pipes, nominal dia 150 mm laid in trenches for sewer network, fixed and jointed with integral socket or coupler and EPDM sealing ring (depending on pipe ends) as per manufacturer instructions complete all as specified and as directed by Engr-in-Charge (Make (DWCPE Pipe) : Supreme, Prince, Berlia or equivalent as specified)
Demolition of brick work/stone masonry built in cement mortar of any description
M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 all as specified and directed as in repairs.
Demolition for reinforcement cement concrete complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs including necessary form work etc for manholes covers set in CM 1:4 (reinforcement measured seperately)
M&L TMT bars 10 mm dia and over cut to length, bent to shape required incl cranking, bending, spirally for hooping for column hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. confirming to Fe-410-S or Fe-410-0.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed by Engineer-In-Charge.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed by Engineer-In-Charge.
Taking down existing old Extg unserviceable LT UG/ service cable of any description and size complete all as specified and as directed by Engineer-In-Charge.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M (Army) Jamnagar complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 79 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH, PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
Description all as per item No. 79 here in before but using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point)
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with Four single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 6 sqmm cable,one run of 6 sqmm earth cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm earth cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 6 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed by Engineer-In-Charge.
Labour only for refixing the celing fan/ Exhaust fan obtained from item No 78 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
S & F for LED down light luminaire round shape 12 watts, white finish operating voltage 150 Volts - 270 Volts AC, 50 Hz, recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copper conductor cases of suitable size with warranty option of 5 years from date of installation complete all as directed by Engineer- in-charge. Make :- Bajaj Cat No BGSLO Sleek Recess RD 12W WH LED or its equvalent in Philips, Wipro.
S & F for LED luminaire 600 mm x 600 mm square LED panel 24/30 watts, 220V AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling, including connecting up with driver three core flexible copper conductor cable of suitable size with warranty option of 5 years from date of installation complete all as directed by Engineer- in-charge.Make :- Bajaj Cat No BZRSQL 43L XE WH OD SD or its equvalent in Philips, Wipro.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro.
S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of three core multistranded copper conductor from ceiling rose to fitting complete all as specified and as directed. Make :- Make Bajaj Cat part No BCLAB 20W WH LED P, Wipro Cat part No LL20-281-XXX065-ALI or its equvalent in Philips, Havells.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired, with warranty option of 5 years from date of installation and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Bajaj Cat part No ENXT P 30L WH CR PC SD or its equvalent in Philips, Wipro.
M & L for taking out Split type air conditioner indoor and outdoor unit complete with copper tubing of any size and re fixing of AC after necessary servicing complete all as specified and as directed by Engineer-In-Charge.
Supply only capillary tube special annealed double wound copper tubing suitable for 1.5/1.8/2 ton window type air conditioner of diameter 0.25 " bore as per existing complete all as specified and as directed by Engineer-In-Charge.
Supply only capillary tube special annealed double wound copper tubing suitable for 1.5/1.8/2 ton window type air conditioner of diameter 0.38" bore complete all as specified and as directed by Engineer-In-Charge.
S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size 3.5 core x 50 Sqmm complete all as specified and directed
Supply & lay GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of size 50 mm dia bore complete all as specified and directed .
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe light grade) and watering pipe 20mm bore GI pipe (medium grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), MS FUNNEL with wire mesh ,coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. incl taking down old earthing complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing wire and protected pipe 15 mm dia of same size upto 7.5m shall deemed to be included into quoted rate
ABR Trading Co
jitendra c joisar
Krishna Bhoomi Enterprise
Quick Building Service
DWARKADHISH ENTERPRISE
Pooja Enterprise
S H CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .