Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.5 LAccepted-AOC 21 1307 B ANUPALLAVI PALLURUTHY COCHIN 682006 | COCHIN | ERNAKULAM | KERALA | 682006 | 1 | Accepted-AOC AGREEMENT EXECUTED | |
| 2 | Rejected-Technical | - | Rejected-Technical REJECTED |
Tender Value
₹10.7 L
EMD Value
₹26,815
Closing Date
23 Nov 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BIJOY K N
SE, Kochi Muncipal Corporation, Park Avenue Ernakulam, Kochi 682011
MOE1/1562/21,Providing new LED posts and renewal of damaged cables at Thevara college compound and play ground in div.59
2023_LSGD_622407_1
MOE1/1562/21,Providing new LED posts and renewal o
Open Tender
Civil Works - Others
Item Rate
90 days
ERNAKULAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹26,815
Yes
22 Jul 2024
16 Nov 2023
25 Nov 2023
16 Nov 2023
23 Nov 2023
16 Nov 2023
Amount
Materials used for the work shall be as per approved list of materials of CLTCE
OD30646/2023-2024:Excavation of soft soil of size 1Mx1Mx1.5M for making of foundation of concrete structure for mounting of Octogenal GI post at a depth of 1.75 mtr .Concreating work includes providing 10 mm thick layer of plain cement concrete at bottom ,and RCC in 1;2;4 of size .6Mx.6Mx0.1mm thick as foot slab and continues RCC work of size .35x.35 mtr for a height of 1.75 mtr and plastering exposed surface with cement plaster.
90.15.3.10:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 155 mm bottom diameter thickness 3mm base plate dimensions of 250x250x16 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 9 Meters
90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.4:Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD29840/2023-2024:Charges for fitting proposed Street light fitting on KSEB/Corporation post at suitable height using 2 setsbelt type GI clamps of minimum size 25x5 mm fitted on 25/32 mm GI pipe of minimum length 1metre using suitable nut bolt etc (pipe clamped on post at 2 locations) and giving connection to the street light main using 1/1.4 mm , 2 core PVC insulated & PVC sheathed 650/1100 V grade aluminium conductor cable with single sheathed outer covering suitable for weather proof application conforming to IS standards.(including charges for conveyance of dismantled materials and connected items to store of corporation )
OD30177/2023-2024:Earthing with GI earth pipe 1.5 mtr. long 40mm dia. medium class including providing 12mm dia,drilled holes minimum 10 nos along the entire length in alternate arrangement providing test joint using 2 nos ,25x3mm GI strip minimum size 25cm suitably shaped and tightly clamped to the pipe electrode using 25x6 mm steel bolts ,nuts &washer & providing 2 nos ,6mm dia. drilled holes for clamping & bolting earth lead & making masonary chamber made of bricks and duly plastered
OD30664/2023-2024:Earthing with GI earth pipe 1 mtr. long 40mm dia. medium class including providing 12mm dia,drilled holes minimum 6 nos along the entire length in alternate arrangement providing test joint using 2 nos ,25x3mm GI strip minimum size 25cm suitably shaped and tightly clamped to the pipe electrode using 25x6 mm steel bolts ,nuts &washer & providing 2 nos ,6mm dia. drilled holes for clamping & bolting earth lead & making masonary chamber made of bricks and duly plastered
90.16.3.2:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm GI strip
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.12.7.6:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 35 sq mm
90.12.5.5:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 25 sq mm
90.12.5.4:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 16 sq mm
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.3:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)
9.1.4:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 25 sq. mm (22mm)
9.1.5:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 35 sq. mm (25mm)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD30273/2023-2024:Fabrication of fully partitioned, dust and vermin proof enclosure for metering/control accessaries cubicle as per approved design and requirement, with front access facility,with locking arrangement using 2.00 mm CRCA sheet with powder coating the assembly after subjecting to 7 tank process etc as required. The cubicle shall be water proof and rain guard of sufficient size shall be provided at the top. Sufficient DIN bars shall be provided for holding control accessaries in the panel assembly.The measurements should be taken the area of the complete sheets used for panel board excluding base frame etc .
OD33331/2023-2024:Supply and installation of 1 Nos of 63 A,415 V HRC bakelite fuse fitting with HRC fuse link and 63 A N/L on existing meter/cubicle board
OD33416/2023-2024:Supply and providing 250x250x170 mm or nearest size thermo plastic outdor junction box suitable for mounting fuse unit/ MCB etc on suitably clamped on tubuler post/on concrete fountation o (SINTEX or equivelent make) with DIN bar for fixing MCB and providing heavy guage connector for loop in and out of aluminium armoured from one post to another cable
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
OD30589/2023-2024:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation40/38 mm or nearest size
OD30596/2023-2024:Supply of dead end clamps with brackets suitable fot LT ABCable on posts.
OD30598/2023-2024:Supply of pole supports/suspension clamps with brackets suitable fot LT ABCable on posts.
OD30599/2023-2024:Supply of EYE hook for laying AB Cables on posts using suitable clamps etc
OD33120/2023-2024:Supply and laying Aireal bunched cable 25sq mm (2+1)3 core from post to post using proposed accessaries including labour charges
OD30597/2023-2024:Charges to be paid to KSEB for availing service connection such as CD,connection charges etc availing supply ,testing complete electrical installation and making installation in proper working condition.Payment will be as per actual paid voucher to the KSEB
AJITH
Bidder Name
CHANDRAMOHANAN
AJITH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .