Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted rate | |
| 2 | L2₹23.7 L+₹59,503.60 (2.58%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-AOC Not accepted since higher quoted rate | |
| 3 | L3₹24.5 L+₹1.4 L (6.14%)Rejected-AOC | L3 | Rejected-AOC Not accepted since higher quoted rate | |
| 4 | L4₹25.6 L+₹2.5 L (10.8%)Rejected-AOC | L4 | Rejected-AOC Not accepted since higher quoted rate | |
| 5 | L5₹25.9 L+₹2.9 L (12.4%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L5 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
Refer Docs
EMD Value
₹45,800
Closing Date
3 Oct 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIR FOR REPAIR REPLACEMENT OF LT OH CONDUCTOR TO LT UG CABLE OF CERTAIN BLOCK AND OLD TYPE STREET LIGHT FITTINGS WITH LED STREET LIGHT AT MIL STN GANDHINAGAR
2020_MES_377527_1
GE(A)/GNR/TOKEN/63 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹45,800
Yes
31 Oct 2020
14 Sept 2020
5 Oct 2020
14 Sept 2020
3 Oct 2020
20 Sept 2020
14 Sept 2020 - 19 Sept 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation all as specified and as directed.
M&L, for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note: Depth after punning shall be measured and paid.
Removing excavated material (Soil) not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Supply and laying, sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
S&F, in repair, GI pipe 40mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
S&F, in repair, GI pipe 50mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
M&L for cutting chases for fixing of GI Pipe of any size on wall/Plinth and including PCC work for making good the distrub surfaces of wall and plinth, including white wash for matching the existing wall complete all as specified and directed.
Supplying & laying, 25 Sqmm, 4 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed.
Supplying & laying, 70 Sqmm, 3.5 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed.
S&F, in repair, LED type street light fittings, IP-66, 60 Watt, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics complete including connecting and testing complete all as specified and directed. Make as per Wipro/Havells/Eveready.
S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide primer complete all as specified and directed.
S&F, in repair, PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, confirming to IS-694/2010 with latest amendment, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. Make of Havells/Polycab/Finolex.
Supply, installation, commissoning and testing, feeder pillar board, Kiosk type, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.5 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 200 amps rating of 04 strip - 01 No (ii) MCCB, thermal and megnatic setting, 4 pole, AC, 415 volts, 125 Amp rating, 25 KA rupturing capacity - 01 No (iii) Multifunction meter showing PF, V, I, Hz,Etc - 01 No (iv) Indicatiing lamp Neon type for R-Y-B - 3 Nos. (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 3 pole, AC, 415volts, 63 Amp rating, 16 KA rupturing capacity - 04 No (ii) Cable connection through straight plugs 63A, 415 Volt - 04 Nos Cat No. - 058705 Tempra Pro IP-67 and Panel mounting Socket 63 Amp, 415 Volt - 04 Nos Cat No. 058725 Tempra Pro IP-67. Make of sockets & Plugs - Legrand/Schneider/Siemens, for MCCB - Legrand/Schneider/Siemens
Supply, installation, commissoning and testing, feeder pillar board, Kiosk type, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.5 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 400 amps 4 pole, 50 KV rating of 04 strip - 01 No (ii) Indicatiing lamp Neon type for R-Y-B - 1 Nos. (III) Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 phase CT network CT priary programmable up to 600 Amps, three line baklit display of phase to phase rating Phase to neutral voltage current active power KW, KVAR and KVA, PF Frequancy. (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 3 pole, AC, 415volts, 200 Amp rating, 25 KA rupturing capacity - 01 No (ii) MCCB, thermal and meganitic setting, 3 pole, AC, 415volts, 100 Amp rating, 25 KA rupturing capacity - 06 No for MCCB - Legrand/Schneider/Siemens
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Electromech Engineers
TRIMURTHI ENTERPRISES
SHOBHIT BUILDERS
Electricals India
Ramdev and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .