| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | ₹5.3 Cr Quoted ₹5.5 Cr | L1 | Accepted-AOC Reasonable rate |
| 2 | L2₹5.6 Cr+₹15.4 L (2.81%)Rejected-Finance | ₹5.6 Cr+₹15.4 L (2.81%) | L2 | Rejected-Finance Quoted amount higher than L1 |
| 3 | L3₹5.8 Cr+₹34.0 L (6.19%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹5.8 Cr+₹34.0 L (6.19%) | L3 | Rejected-Finance Quoted amount higher than L1 |
| 4 | L4₹6.0 Cr+₹55.2 L (10.0%)Rejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹6.0 Cr+₹55.2 L (10.0%) | L4 | Rejected-Finance Quoted amount higher than L1 |
| 5 | L5₹6.1 Cr+₹62.6 L (11.4%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹6.1 Cr+₹62.6 L (11.4%) | L5 | Rejected-Finance Quoted amount higher than L1 |
Tender Value
₹6.4 Cr
EMD Value
₹6.5 L
Closing Date
6 Sept 2023, 6:00 pmClosed
Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
ADDN ALTN AND SPL REPAIRS TO JCOs ORs MD ACCN AT MASIMPUR MIL STN
2023_MES_612736_1
8824/E8
Open Tender
Civil Works
Item Rate
545 days
Silchar
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
GE Silchar
₹6.5 L
Yes
9 Dec 2023
8 Aug 2023
13 Sept 2023
8 Aug 2023
6 Sept 2023
30 Aug 2023
Amount
Dismantling of AC Sheets [Corrugated or Semi Corrugated etc] as in roof covering including ridges, hips, valleys and flashings complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
Dismantling wooden boarding (eaves board etc) of any description fixed in any position with nails complete all as specified and as directed.
Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws with rubber washer as per manufacturer instruction complete all as specified and as directed.
Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws with washer as per manufacturer instruction complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Roof Trusses [framed], trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing [Beam, tee, angle, channel or flat sections] including distance pieces, cleats etc complete all as specified and as directed.
Material and labour preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Material and labour preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
Taking down water tank including ball valve assembly and refixing the same after Cleaning and removing all scales, dirt, deposited sediments from HDPE Tank of capacity exceeding 500 Litres but not exceeding 1000 litres, from mouths of circulating pipes of water tanks using wire brushes and other means and washing internal surfaces, cleaning with fresh water mixed with bleaching powder including draining of water through drain pipe line complete all as specified and as directed.
Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layered hoisted and fixed in position including dismantling of existing unserviceable water tank of any capacity complete and all as specified and as directed.
Supply and fix Ball Valves, 25 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe [Minimum Weight 25mm - 455 Grams] complete all as specified and directed .
Demolition of cement concrete (unreinforced) in any position not otherwise specifically provided for and removal of rubbish from the site complete all as specified and as directed.
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 40 mm thick PCC (1:2:4) type B0 using 12.50 mm graded stone aggregate as levelling course on roof top or similar work finished fair & even complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B0 using 12.50 mm graded stone aggregate as in haunching, roof kerb, levelling course or similar work complete all as specified and as directed.
Supply only integral water proofing compound (WPC) of best quality (ISI marked).
M & L for cleaning surfaces to receive the water proofing treatment, applying 10mm thick plastering in CM 1:4 mixed with WPC @ 3% by weight of cement finished even and smooth and curing for seven days and after fully dried plastered surfaces cleaning the plaster surfaces, applying one coat of hot paving bitumen of penetration value 85/25 conforming to IS 73 @ 1.20 kg/sqm over a coat of bitumenous primer @ 0.25 ltrs per sqm and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.00 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) shall be applied over Bitumenious primer (Application of polymeric memberane shall be by torch application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinal direction) polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by membrane flashing, (conti..)
coved fillet in PCC (1:2:4) type B-0 of radius 75 mm shall be provided at the junction of roof & other vertical surfaces and surfaces shall be painted with hot paving bitumen of penetration value 85/25 conforming to IS 73 @ 1.20 kg/sqm & applying one coat of aluminium paint over the APP modified membrane @ 0.11 kg/sqm complete all as specified and as directed. Note: (i) WPC will be measured and paid separately. (ii) Cutting of grooves will be carried out by using mechanical means like groove cutter/wall chaser.
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing unserviceable tiles and rubbish off the premises complete all as specified and as directed.
M&L for 25 mm thick ,PCC(1:2:4), type B-0, using 12.50 mm graded aggregate as in sub floor and finished the surface even and fair all as specified and directed.
Material & Labour for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.11 sqm but not exc 0.18sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I)/GE.
Material & Labour for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I)/GE.
Material & Labour for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38sqm as in skirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over and including rendering of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I)/GE.
Material and labour coloured Glazed ceramic tiles of size 300 X 450 X 7mm thick of premium quality as in skirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over and including rendering of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I)/GE.
Material and labour 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed in cm (1:6) complete all as specified and as directed. Note: The colour / shade / design of granite shall be as approved by AGE(I)/GE.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
Material and labour for providing Reinforced Cement Concrete 1:1.5:3 type A0 using 12.50 mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar work, etc. not exceeding 200mm thick with rough finished surfaces of concrete flat complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide with rough finished surfaces of concrete complete all as specified and as directed.
Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars 6mm to 8mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
Material and labour for 5 mm thick rendering in cement mortar (1:3) of ceiling surfaces finished even and smooth complete all as specified and as directed.
Dismantling wall and ceiling boards (AC, fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets complete all as specified and as directed.
Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI systtem duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fast complete all as specified as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size exceeding 1.50 Square metre but not exceeding 4.00 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fast complete all as specified as directed.
Supply and fix 105x60mm size pressed steel, frames made of 1.25mm thick MS sheet for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate including one coat of shop primer complete all as specified and as directed.
Supply and fix 125x60mm size pressed steel, frames made of 1.25mm thick MS sheet for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate including one coat of shop primer complete all as specified and as directed.
Material and labour Cement concrete (1:3:6), type C-0 using 12.5mm graded stone aggregate as in filling of hollow steel frames and holdfast including necessary form work complete all as specified as directed.
Supply and fixing 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides , smooth finish with lipping of teak wood on edges complete all as specified as directed.
Supply and fixing 35 mm thick, 2nd class hard wood glazed and skeleton door shutters open rebated and prepared to receive glass, guage etc (without sash bars ), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR Part I section 8 clasue 8.20(a) complete all as specified and as directed.
Supply and fixing Factory Made 28 to 30mm thick single/double leaf Solid PVC Moulded Door Shutter with particle board core, (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet plyurethane painted on the front face & 2mm plain colour termite proof , water proof and fire resisitant PVC sheet on back face, fixing in frame at site as per specification and drawing complete all as specified and as directed.
Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and as directed. (ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid separately.
Supply and fixing Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 24mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed. Note: stainless steel butt hinges and necessary S.S screws shall be measured and paid separately.
Supply and fixing Cupboard shutter made of 1.00 mm thick MS Sheet fabricated with edges bend to shape suitable of single rebate pressed steel frame of 1.25mm thick including stainless steel hinges, standard rim locking arrangements, handles including all necessary fittings drilling hold hasts / lugs and painting with entirely with two coats of synthetic enemal paint over one coat of red oxide zink chrome primer as approved colour and other necessary fittings/fixtures and lock etc for making fully fuctunal same as steel lockers/cupboards complete all as specified and as directed.
Supply and fixing pre-laminated particle board,18/19 mm thick interior grade, having one side decorative lamination (approved shade) and other side balancing white lamination fixed in shelves etc , rebated or flat edges including 6 mm thick teak wood leaping all-round and fixed complete all as specified and as directed.
Supply and fixing of Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe 290 Gde-E-165 complete all as specified and as directed.
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for windows & ventilators any pattern complete with frame including cost of providing and fixing hinges/side lock/rollers for sliding windows and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Mesh will be measured and paid separately and balance fittings fixtures shall be deemed to be included in the unit quoted rate.
Supply only 4 mm thick Sheet glass, ordinary quality in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
Supply only 4 mm thick frosted glass, ordinary quality in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
Supply only Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixing stainless steel butt hinge, 100mm long, medium weight, cold rolled fixed with steel screws or welded to steel frame where required complete all as specified and as directed.
Supply and fixing Floor Door Stopper of size 140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
Supply and fixing Mild Steel Door Spring 300 mm, Ordinary Rat Rail Rod Pattern springs including roller and roller plate complete all as specified and as directed.
Supply and fixing 300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts,of extruded sections or cast aluminium alloy complete all as specified and as directed.
Supply and fixing aluminium anodized, barrel tower bolts, 200mm long of extruded section complete all as specified and as directed.
Supply and fixing aluminium handles, fabricated type, anodised 125 mm long fixed with screws complete all as specified and as directed.
Supply and fixing in repairs minimum 1 mm thick MS chromium plated Curtain Rod of 25 mm dia including PVC rings @ 100 mm centre to centre, fancy type side brackets end knobs of size suitable to 25mm dia curtain rod fixing SS screws and rawl plugs complete all as specified and as directed.
Material and labour for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Supplying and laying GI tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc laid in floors/ fixed on walls including testing complete all as specified and as directed.
Refixing of 15mm dia old serviceable GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls/ laid on floors including testing complete all as specified and as directed. Note: Old serviceable GI tube obtained from taking down vide item No 60 shall be reused.
Supplying and laying GI tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc laid in floors/ fixed on walls including testing complete all as specified and as directed.
Refixing of 20mm dia old serviceable GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls/ laid on floors including testing complete all as specified and as directed. Note: Old serviceable GI tube obtained from taking down vide item No 61 shall be reused.
Supplying and laying GI tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc. laid in trenches including testing including taking down of existing unserviceable GI tubing complete all as specified and as directed. Note: Earth work and excavation will be measured and paid separately.
Supplying and laying GI tubing of 50 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc. laid in trenches including testing including taking down of existing unserviceable GI tubing complete all as specified and as directed. Note: Earth work and excavation will be measured and paid separately.
Supplying and laying GI tubing of 80 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc. laid in trenches including testing including taking down of existing unserviceable GI tubing complete all as specified and as directed. Note: Earth work and excavation will be measured and paid separately.
Material & Labour for cutting the existing pipe line upto 80mm bore and inserting new tubing in position complete all as required at site complete all as specified and as directed.
Material & Labour for CI bends upto 150mm bore (any type, radius and angel) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified and as directed. Note: Cutting chases will be carried out by using mechanical means like Groove cutter/ wall chaser.
Supply & Fixing in repairs, Gun Metal Globe or Gate Valve of Class - I Pressure Tested of 1.5 Mpa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS-778, ISI Marked complete all as specified and as directed.
Supply & Fixing in repairs, Gun Metal Globe or Gate Valve of Class - I Pressure Tested of 1.5 Mpa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS-778, ISI Marked complete all as specified and as directed.
Supply & Fixing in repairs, Gun Metal Globe or Gate Valve of Class - I Pressure Tested of 1.5 Mpa, 50 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS-778, ISI Marked complete all as specified and as directed.
Supply & Fixing in repairs Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, 80 mm Dia, confirming to IS – 14846, Class PN –1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
Supply & Fixing in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe and union etc. complete all as specified and as directed.
Supply & Fixing in repairs 15 mm bore, Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.
Supply & Fixing in repairs white Vitreous China Squatting Pan "Orissa Pattern" of size 580 mm X 440 mm with integral foot rests and 'P' or 'S' Trap including provision of lime concrete bedding complete all as specified and as directed.
Supply & Fixing in repairs 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia and union etc. including brackets and connections to pipe complete all as specified and as directed.
Taking down & refixing of old serviceable PVC low level flushing cistern of any description complete all as specified and as directed.
Supply & Fixing in repair PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified and as directed.
Supply & Fixing in repair Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws, wooden rawl plugs complete all as specified and as directed.
Supply & Fixing in repair 200mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass complete all as specified and as directed.
Supply and fixing in repair Stop Valves/ angle valves, 15 mm bore dia of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed.
Supply and fixing in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed.
Supply and fixing in repairs Bib Taps, 15 mm dia, brass, Chromium Plated, Fancy Type, long Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
Supply and fixing in repairs Corner Glass Shelf of size 225mmx 225mm, height of railing 70mm including fixing arrangements complete all as specified and as directed.
Supply and fixing in repairs Stainless steel kitchen sink with draining board, made of stainless steel sheet of 1 mm thick, with plugs, washers, Waste Fittings, 32 mm dia, Brass, Chromium plated, and 32mm dia PVC flexible Waste Pipe, 750 mm long, including bedding in Cement Mortar to dwarf wall or including fixing cantilever CI Brackets and connecting union to waste pipe, over all size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
Taking down and refixing of old serviceable SS kitchen sink of any description complete all as specified and as directed.
Supply and fixing in repairs Stainless Steel Kitchen Plate Rack made of 1.00mm thick stainless steel sheet of size not less than 775 X 600 X 250mm complete all as specified and as directed.
Taking down and refixing of old serviceable SS plate rack of any size complete all as specified and as directed.
Material and labour PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent complete all as specified and as directed.
Dismantling asbestos cement/PVC pipe 50/75/100 mm dia including clamps complete all as specified and as directed.
Supply and fixing 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors /fixed on wall including clamps complete all as specified and as directed.
Supply and fixing 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors /fixed on wall including clamps complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius, 110mm bore, fitted with oval access door including jointing with solvent cement complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius, 110mm bore including jointing with solvent cement complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius, 75mm bore, fitted with oval access door including jointing with solvent cement complete all as specified and as directed.
Supply and fixing PVC (SWR) reducers of 110mm bore including jointing with solvent cement complete all as specified and as directed.
Supply and fixing 110mm bore PVC (SWR) junction, single (single T) equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
Supply and fixing PVC (SWR) vent cowl of 75mm dia including jointing with solvent cement complete all as specified and as directed.
Material & Labour for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth with out using extra cement and providing necessary joints 12mm wide to the full depth of PCC at every 3 meters and every change of directions and the joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
Material & Labour for plain cement concrete type C1 (1:3:6) using 20 mm graded aggregate in surface channel/drain complete all as specified and as directed.
Material & Labour plain cement concrete type C1 (1:2:4) using 20 mm graded aggregate in surface channel/drain complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm (for adjustment in girth of item No. 106 Above)
Material and labour 10mm thick rendering in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 5mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 on concrete or brick masonry surfaces including mixing water proofing compound @3% by weight of cement in top coat and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Material and labour for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 15mm thick in cm 1:3 cement plaster on fair faces of brick or concrete surfaces finished even and smooth without using extra cement, with water proofing compound @3% by weight of cement complete all as specified and directed.
Material and labour for preparing surfaces of sunken floor or beam and applying two coat of Brush Bond RFX of M/s. Fosroc Chemicals or equivalent make as specified in Particular Specification complete all as required and as directed at site.
Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and as directed.
Material & Labour for single component polymer modified repair mortar with compressive strength minimum 38 MPA at 28 days (ASTM C 109:99) and tensile strength minimum 2.5 Mpa (ASTM C 307) up to 15mm in a single coat @ 34 kg per sqm for 15mm thickness as per manufacturer instructions complete all as directed. Make : Single component polymer modified repair mortar Sika Top 120 HS or equivalent make as specified in Particular Specification.
Material & Labour for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface.
M&L for applying two coats of oil bound distemper including primer as per manufacturer guidelines using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
Material and labour for one coat of acrylic water based exterior grade primer @0.9 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and irected.
Material and labour for two coats of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre , Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat (included) with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
Note for serial item No. 112 to 118 :- (a) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (b) Cost of scafolding upto 10m hight of building is included in this item. (c) The work shall be executed by authorized reps of the approved manufacturer. The contractor shall submit the ‘Memorandum of understanding’ (MOU) with one of the approved manufacturer before placing the work order. (d) 05 years guarantee of painting work will be admissible after date of completion and 15% amount will be reserve against painting work after date of completion for the 05 years.
Material and labour for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and asdirected.
Material and labour for preparation of new or previously untreated ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etc and applying three coats of white wash complete all as specified and as directed.
Material and labour for preparation of old decorated plastered or unplastered ceiling surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of white wash complete all as specified and as directed.
Supply & Fixing 5mm thick PVC sheet fillet of width 35mm to make PVC Frame complete all as specified and as directed.
Supply & Fixing 18mm thick PVC board of grade 1 quality, both side pre laminated, coloured, fixed with screwes, solvent cement / adhesive to make kitchen cabinate sides top and bottom, shelves inside the cabinete and shutter or drawer complete all as specified and as directed.
Supply & Fixing stainless steel handles of 100mm size for kitchen cabinate shutter fixed with screws complete all as specified & as directed.
Supply & Fixing 75mm long stainless steel hasp & staple for kitchen cabinet shutter fixed with screws complete all as specified & as directed.
Supply & Fixing auto closing hinges 35mm of 0 crank or 8 crank openable at 110 degree for kitchen cabinet shutter fixed with screws complete all as specified & as directed.
Surface excavation n .exc 30 cm deep and averaging 15 cm deep and and getting out in soft / lose soil complete all as specified & as directed.
Excavating in post holes (or similar holes ) each n.exc. 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth round in layers n.exc. 25 cm in soft/loose soil complete all as specified & as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
Material and labour for PCC 1:4:8 type C2 using 40 mm graded broken stone as in foundation, filling and mass concrete complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C2 using 40 mm graded broken stone as in foundation, filling and mass concrete complete all as specified and as directed.
Demolition of brick work of any description and in any position built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
All as per item No. 135 above but except bricks built in cement mortar (1:4), cleaning and removing of mortar from old bricks complete all as specified and as directed.. Note : Old serviceable bricks obtained from demolition vide serial Item no. 133 shall be reused.
Materials and labour for half brick thick brick work with sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed.
Supply and fixing structural steel work in tubular / square hollow section trusses , Purlin , posts, rafter etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979/ IS 4923-1997 grade St.-240 complete all as as specified and as directed.
Supply and fixing plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachment of Fe 410W (Gde-E -250) Quality 'B' complete all as specified and as directed.
Supply and fixing MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut not exceeding 5 cm long, dia of neck exceeding 11 mm but not exceeding 15 mm complete all as specified and as directed.
Returning, filling in including spreading and levelling watering and well remming in layeres n.exc. 25cm thick complete all as specified and directed.
Removing excavated material not exceeding 50 meters & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Material and labour for 75 mm thick Plain Cement concrete type B-1, P.C.C 1:2:4 (20mm graded aggregate) as in flooring, surface finish even and smooth without using extra cement complete as specified.
Material and labour for Aluminium dividing strips, 38mm wide and 1.5mm thick, inserted in position to conform to design, fixed in floor complete all as specified and as directed.
Material and labour for 75 mm thick Plain Cement concrete type D2 1:4:8 (40mm graded crushed stone aggregates) as in subbase for flooring, finish the surface even and fair complete all as specified and as directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair without using extra cement complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B0 using 12.50 mm graded stone aggregate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, benching, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed.
Material and labour for Moorum/red bajri filling in floors or pavings , laid in layers n exe 150 cm thick (Compacted thickness) ,spread, levelled ,rammed including watering complete all as specified and directed.
Material and labour for 100mm thick Plain Cement concrete type B-2, P.C.C 1:3:6 (40mm graded aggregate) as in subbase for flooring, finished the surface even and fair complete all as specified and directed.
Material and labour pre polished (rubber moulded) coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade including 50mm thick sand cushioning complete all as specified and as directed.
Material and labour for 75mm thick Plain Cement concrete type C-2, P.C.C 1:3:6 (40mm graded aggregate) as in subbase for flooring, finished the surface even and fair complete all as specified and directed.
Material and labour pre polished Chequered cement concrete tiles of size 300mmx300mm of 25mm thick as in floors set , jointed & pointed with neat cement slurry with white cement and pigment including 20 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed.
Cleaning of existing sewage pipe lines of any bore and removing the blockages by rodding using split bamboo or by mechanical means or by any other means, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered) and taking out all debris, sludge or any solid/ foreign materials from sewage line and flushing with water and testing after cleaning for free flow of sewage complete including removing the debris to a distance exceeding 250 m but not exceeding 500m and buried under ground to a depth of 1.0m complete all as specified and as directed. Note: The rate quoted shall be deemed to include taking out existing cover slabs of manholes of any description and size without damaging the slab to facilitate cleaning of pipes and replacing back in original position.
Cleaning of manholes near building of any description and in any position depth not exc 1.5mtr deep mechanically by taking off sludge waste/ night soil and silted soil from the existing manhole of any size, collecting and removal of sludge in sealed container and disposal of the same out side premises boundary complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed.
Material and labour for PVC (SWR) pipes 110mm dia, Single socketed, in any length, including rubber rings with cement joints, laid in trenches or in floors complete all as specified and as directed.
Material and labour for PVC (SWR) pipes 150mm dia, Single socketed, in any length, including rubber rings with cement joints, laid in trenches or in floors complete all as specified and as directed.
Material and labour for cement concrete bed (1:3:6) type C-2, using 40 mm graded to drain pipe including packing under and haunching against the side of pipe after they are laid and tested for bore of pipe 110 mm complete all as specified and as directed.
Material and labour for cement concrete bed (1:3:6) type C-2, using 40 mm graded to drain pipe including packing under and haunching against the side of pipe after they are laid and tested for bore of pipe 150 mm complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 110 mm internal dia of pipe complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of rubbish from the site complete all as specified and as directed.
Material and labour for providing Precast RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing complete all as specified and as directed.
Material and labour for concealed point wiring with FRLS stranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated cable 1100 volts grade drawn through PVC conduit including all accessories etc ISI marked in concealed with GI sunken boxes with earth dolly and cover plate with frame suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor connecting to common earth dolly for one light point/ fan point/ bell point complete all as specified and as directed.
All as per item No 165 above but for 3 pin 5 Amp socket outlet point controlled by one switch on the same board complete all as specified and as directed.
All as per item No 165 above but for 3 pin 5 Amp socket outlet point controlled by one switch on independent board complete all as specified and as directed.
All as per item No 165 above but with FRLS stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including FRLS PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
All as per item No 165 above but with FRLS 4 sqmm starnded copper conductor for one power point on independent board and including 4 sqmm earth continuity wire for AC/equipments etc controlled by one SP/SPN MCB. Note: (i) The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. (ii) MCB will be measured and paid separately.
Supply & Fixing ceiling rose surface bakelite with three terminals complete all as specified and as directed
Supply & Fixing switch piano flush type button single pole one way 5 Amps all as specified and directed.
Supply & Fixing socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed.
Supply & Fixing switch socket combination 2 in 1, 5/16 Amp flush type with all as specified and directed.
Supply & Fixing ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and as directed
Supply & Fixing lamp angular holder insulated body with back plate suitable for batten fittings complete all as specified and as directed
Supply & Fixing bell push flush type 5 Amps complete all as specified and directed.
Supply & Fixing bell electric ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
Material & Labour for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC Casing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfaces complete all as specified as directed. Note : (i) 3 Runs of 6.0 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.
Taking down of electric meter from existing box at site, keep in safe custody and re-fixing the same with poly carbonate box at existing/new location complete all as specified and directed
Taking down carefully 20 Watt LED Batten fitting, keep in safe custody and re-fix the same after completion of necessary repair work at site complete all as specified and directed.
Supply & Fixing wall mounted, compact LED batten 20 watt having 30 mins backup (working as regular 20 watt in normal mode and 4 watt in backup mode) and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note: Light fitting shall be of PF>0.95 Make: Cat No LDLL20-BK4-CDL of Crompton or equivalent makes as specified in Particular Specification.
Supply & Fixing, rimless surface downlighter, LED 12 watt and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note: Light fitting shall be of PF>0.95 Make-Cat No LSDSSV-12W-CDL of Crompton or equivalent makes as specified in Particular Specification.
Supply & Fixing LED bulb 10 watt, 5 star rated and fixed in lamp holder complete all as specified and directed. Note: Light fitting shall be of PF>0.95 Make-Cat No LED 10W 5 Star Lamp of Crompton or equivalent makes as specified in Particular Specification.
Supply & Fixing Energy efficient & Long life Building Security Light Luminaire, of 25 watt, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 Make-Cat No. LSTS-25-CDL/NL-M of Crompton or equivalent makes as specified in Particular Specification.
Supply & Fixing Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep of any colour as approved, 03 blades, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 374, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, including Down Rod, Canopies, Shackles, Safety Rope, Hanging Clamps, Bushes, having P.F >0.95, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% including provision of Electronic speed control Regulator step type, including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and taking down existing ceiling fan of any description and depositing at MES Store Yard complete all as specified and as directed. Note: Ceiling Fan shall be provided with 03 Years onsite replacement warranty. Rate quoted is deemed to be including the same and nothing shall be paid extra on this account.
Supply & Fixing Exhaust Fan, 300mm Sweep, 1200 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and fixing in existing opening and making good the disturbed surface to match with existing and taking down existing exhaust fan of any description and depositing at MES Store Yard complete all as specified and as directed.
Supply & Fixing plastic body exhaust fan 300mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with 3 core flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down and removing old UNSV fan and depositing to MES store yard complete all as specified and as directed.
Supply & Fixing Energy efficient, BEE 5 Star rated Storage type Water Heater [Geyser] 25 Litres Capacity with 2000 Watt Capacity heating element Conforming to IS - 2082, Vertical Storage type with Stainless Steel Inner Tank and ABS Outer Shell complete fixed to wall with suitable expansion fasteners including 02 Nos. of 450 mm long x 15mm dia Stainless Steel braided Flexible Hot & Cold Water connections and 15mm bore Non-Return Valve and including disconnecting and removing old unserviceable Water Heaters of any description and depositing at MES Store Yard complete all as specified and as directed.
Supply and fixing of MCB DB SPN 8 ways, powder coated, double door, 230 Volts, including bus bar neutral link, earth bar and din rail, for fixing MCB of various rating including taking down old unserviceable DB alongwith MCBs including making good disturbed surfaces complete all as specified and as directed.
Supply and fixing of MCB DB TPN 4 ways, powder coated, double door, 230 Volts, including bus bar neutral link, earth bar and din rail, for fixing MCB of various rating including taking down old unserviceable DB alongwith MCBs including making good disturbed surfaces complete all as specified and as directed.
Supply & Fixing in repairs of SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
Supply & Fixing of MCB SP of capacity 6-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed.
Supply & Fixing of MCB SPN of capacity 40 to 63 Amps, 240 V, 10 KA 'C' curve complete all as specified and as directed.
Supply & Fixing of MCB TPN of capacity 63 Amps, 240 V, 10 KA 'B' curve complete all as specified and as directed. Note for serial Item No. 189 to 194: MCB and MCB DB shall be of same make as approved by GE.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set complete all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Taking out old U/s XLPE cable of any size/type complete all as specified and as directed.
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe as per IS 7098 (Part I) etc including cable glands, aluminium lugs complete all as specified and as directed. Note:-Excavation and earth work will be measured and paid separately
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe as per IS 7098 (Part I) etc including cable glands, aluminium lugs complete all as specified and as directed. Note:-Excavation and earth work will be measured and paid separately
Taking out old bricks from trenches and stacks serviceable bricks and removing of unserviceable bricks complete all as specified and as directed.
Relaying of serviceable old bricks obtained from taking out old bricks vide serial Item no. 199, laid flat width wise along the length of cable for cable protection including cleaning of bricks complete all as specified and as directed.
Material and labour for well burnt subclass 'B' bricks laid flat width wise along the length of cable for cable protection complete all as specified and as directed.
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Supply and laying 50 mm bore galvanised GI tubing, light grade with all fittings for passing of UG cables including taking up / down old unserviceable tubing complete all as specified and as directed.
Dismantling of old panel complete with all accessories and supply, installation, testing and commissioning, CPRI approved factory made and tested, LT feeder pillar box, outdoor type of size 1100mm x 1000mm x 350mm platform mounted. The panel shall be dust and vermin proof, IP65 class protection and madeout of 3.15 mm thick CRCA MS Sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of 32 x 6mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories complete all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department.
M/s Nice Traders
New Era Engineers
MAA BHAGWATI ASSOCIATES
Garg Brothers
Prasur Electricals & Engineering Co.
surendra infrastructure pvt ltd
M/s KASHMIRA SINGH BARMI AND SONS
AMIT ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .