EX. ENGINEER (ELECT)-IV/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Improvement Development of Electric and other allied Work at Dr. Ambedkar Aushadhalaya Devnagar Dispensary
2023_MCD_167986_1
MCD/TR/6661/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
60 days
Karol Bagh
5 documents required · 5 mandatory
₹590
₹11,550
19 Oct 2023
18 Sept 2023
25 Sept 2023
18 Sept 2023
23 Sept 2023
18 Sept 2023
Amount
SR items
OD10260/2023-2024:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(b) 25 mm
OD10262/2023-2024:P/F ABC(Aluminium Phosphate) Power type fire extinguisher of 6 Kg capacity complete in all respect with ISI mark i/c fixing arrangements etc. as reqd.
OD10263/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240 / 415 Volt 50 Hz AC Supply (a) 1 hp (0.75kW) single phase pump set head from 12-30 metre suction and delivery 25x25 mm
OD10264/2023-2024:Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
OD10265/2023-2024:Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of size not exceeding 25mm2 on surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
OD10266/2023-2024:Providing and fixing 25mmX5mm GI strip on surface or in recess for connections etc as reqd.
OD10267/2023-2024:Supplying and laying 25mmX5mm GI strip at 0.5 metre below ground as strip earth electrode,including connection/terminating with GI nut,bolts,spring, washer etc as reqd. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
OD10268/2023-2024:Earthing with G.I. earth plate 600mmX600mmX6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/ coke and salt) as required
OD10269/2023-2024:Supplying and fixing following rating, Two pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 40 Amp.
OD10270/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) 63 amps
OD10271/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole and Neutral
OD10272/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
OD10273/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
OD10274/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as reqd. Upto 450 mm sweep
OD10275/2023-2024:Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module
OD10276/2023-2024:Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
OD10277/2023-2024:Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)
OD10278/2023-2024:Supplying and fixing modular blanking plate on the existing modular plate & switches excluding modular plate as reqd.
OD10279/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
OD10280/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
OD10281/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
OD10282/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
OD10284/2023-2024:S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(d) 3X 6 sq mm
OD10285/2023-2024:S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(c) 6X2.5 sq mm
OD10286/2023-2024:S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(a) 3x2.5 sq mm
OD10287/2023-2024:Rewiring for light point/fan point/exhaust point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as reqd.
OD10288/2023-2024:Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
OD10289/2023-2024:Wiring for light / power plug with 2 X 4 sqmm FRLSPVC insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no 4sqmm FRPVC insulated copper conductor single core cable for loop earthing as required.
OD10290/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD10291/2023-2024:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
OD10430/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD10313/2023-2024:Wiring for light/fan point/exhaust fan point call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recess medium class PVC conduit with modular switch, modular plate,suitable size GI box and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable etc as required. Group C
OD10314/2023-2024:Supplying and fixing suitable size GI box with modular plate and cover in the front of surface or in recess including providing and fixing 6 pin 5/6 and 15/16A modular socket outlet and modular 15/16A modular switches connections etc as reqd.
AR items
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.38:S/I/T/C of Surface mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/recess with connections as reqd. (a)Total system wattage = 36 watt +/- 5% (b )Luminous efficacy >=95 lumens /watt. (c)Power factor >=0.95
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.111:supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
122.2.115:S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
122.2.117:S/I/T/C of copper pipe for split AC
122.2.118:S/I/T/C of Drain Pipe
122.2.119:S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner
122.2.125:SITC of 40AH 12 Volt lead acid battery with rack etc. as requrired with four years comprehensive maintenance after one year defect laibility period and battery cost in 3rd year.
122.2.131:Supply, Installation, Testing and Commissioning of 1.5 Ton, 5 Star rated Inverter Split air conditioner with rotary compressor (R32 Refrigerant) having copper condenser complete with outdoor unit as required.
122.2.176:Supplying & Installation of Hot Cold & Normal Floor Standing Top Loading Water dispenser with Cooling Cabinet Fridge cold water storage capacity up to 3.5 ltr with hot water storage capacity up to 1 ltr as required.
KAFIL ELCTRICAL WORKS
Bidder Name
ELECTROMECH ENTERPRISES
KAFIL ELCTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .