Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-Finance | ₹1.1 Cr | L-1 | Accepted-Finance Lowest bidder |
| 2 | L-2₹1.1 Cr+₹27,327.46 (0.24%)Rejected-Finance | ₹1.1 Cr+₹27,327.46 (0.24%) | L-2 | Rejected-Finance Highest bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not qualified |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
18 Apr 2026, 11:00 amClosed
EXECUTIVE ENGINEER
ELECTRICAL DIVISION HPPWD PALAMPUR
Construction of Rajiv Gandhi Day Boarding School at Sr. Sec. School Dhaliara in Tehsil Dehra, Distt. Kangra (H.P.).(SH Providing E.I. therein).
2026_PWD_133871_1
Electrical Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Dhaliara
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,000
₹2.2 L
Yes
19 Jun 2026
10 Apr 2026
18 Apr 2026
10 Apr 2026
18 Apr 2026
10 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | |||||
| 1.01 | Group C. | 1,728 | P/Pt | 1,238 | ₹21,39,264 |
| 2Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.FRLS PVC insulated copper conductor single core cable etc as required. | |||||
| 2.01 | Group C. | 25 | P/Pt | 1,310 | ₹32,750 |
| 3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required | |||||
| 3.01 | 2X1.5Sq.mm+1X1.5Sq.mm Earth wire | 1,360 | P/Mtr | 198 | ₹2,69,280 |
| 3.02 | 2X2.5Sq.mm+1X2.5Sq.mm Earth wire | 1,790 | P/Mtr | 249 | ₹4,45,710 |
| 3.03 | 2X4Sq.mm+1X4Sq.mm Earth wire | 665 | P/Mtr | 311 | ₹2,06,815 |
| 3.04 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 35 | P/Mtr | 432 | ₹15,120 |
| 3.05 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire | 140 | P/Mtr | 571 | ₹79,940 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
BOQ_197894.xls
BOQ • 0.43 MB
7.pdf
Tender Documents • 3.98 MB
DECLARATION.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .