Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
31 Jul 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy chief Engineer PD and EP
Dy chief Engineer PD and EP 2nd floor Sarathi Building NFC Hyderabad
Renovation of 1.5 mm thick SS Duct for existing North Side WASS at UOP Wet Area NFC Hyderabad
2025_NFC_866963_1
E/682/2025
Open Tender
Electrical Works
Item Rate
Hyderabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹43,000
1 Aug 2025
1 Jul 2025
1 Aug 2025
1 Jul 2025
31 Jul 2025
11 Jul 2025
4 Jul 2025 - 8 Jul 2025
Amount
SS304 Ducting: Supply and Installation of SS Duct with SS Flange(70x70x6mm) along with accessories like SS Tie rods(M10x2.5meters), SS nuts and bolts(M8x50mm),gasket etc. As per approved drawing. Note: Duct base supports are cover in another item no 4.
Supply:1.5mm thicknes duct
Erection:1.5mm thicknes duct
THERMAL INSULATION OF DUCTS (OUTDOOR ): Supply and Erection of External Thermal Insulation of Supply Air and return air ducting coming out side. Material of construction shall be cross linked polyolefin/polyethylene foam material with closed cell structure and with factory applied reinforced aluminium foil. The density of the same shall be within 25 Kg/m3.The material should have a thermal conductivity not exceeding 0.032 W/mK. The insulation material shall be shall be stuck to the cleaned duct surface by factory pre-fixed cold adhesive. The finishing will be carried out with fixing 200 gsm glass cloth with the help of adhesive Fevicol lag coating (AF 5590) . Finally it will be painted with Epoxy painting. The material and installation methodology should be in accordance with the specifications. Insulation shall be of 25 mm thick.
Supply
Erection
Stainless Steel SA grills : Supply & Installation of SS Grills ( of minimum thickness of 0.8mm )with Valume Control dampers for Supply Air
Supply
Erection
STRUCTURAL FABRICATED STEEL WORK: Supply, Fabrication , Cutting, Welding , Erection at site and painting of M. S. structural steel work for required truss, Supporting structurer & as per site requirements, etc. based on the approved drawings. The work should be carried out as per good manufacturing and installation practices in concurrence with approved drawings. The structural steel materials should confirm to IS : 2062 (latest version) as per drawings. All welding electrodes to confirm to relevant IS codes. Fabrication and erection of the structural steel works shall be as per IS: 800 and welding work as per IS:816 and IS: 822. Finally all steel work to be painted with one coat of Red Oxide primer and two coats of epoxy paint.
Supply
Erection
PCC CIVIL WORKS:Plain Cement Concrete (P.C.C) 1:1.5:3 by insitu mixing using Weigh Batching or RMC of Grade M-20 using Ordinary Portland Cement(OPC) conforming to IS 269 or Portland Pozzolana Cement (PPC) conforming to IS 1489 Part-1 with Minimum Cementitious Content not less than 320 Kg/Cum (M/s. ACC,Ultra Tech, Raasi, Birla, Coromandal, Andhra Cements Ltd. make) with crushed stone sand and graded stone aggregates of 20mm maximum size at all depths/heights below/above plinth level including consolidation, finishing smooth/broom finish as applicable, curing, etc., Wall breaking, closing, plastering etc to run duct as per site required and complete as specified and directed.
Supply
Erection
Scaffolding: Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding in excess of 3.5m height shall be measured for payment purpose and to erect duct of sizes (1.5x1.5x6M) including all necessary safety measures, platforms, guardrails, toe boards, and access ladders as per site requirements and safety standards.Area of Scaffold (6Mx3M). Note: The payment will be made once irrespective of duration of scaffolding.
Hiring of Hydra/Crane: Hiring of mobile hydraulic crane of 25Tonne capacity, 40m boom length along with lifting tools and tackles, necessary documents and certificates, submission of erection methodology along with load calculation and getting the approval the department for the erection of duct at 10mm height with minimum 40 meters boom.
TOOT MNE TECH Private Limited (BID ID -3249025)
Rishika Industrial Equipments & Services (BID ID -3258207)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .