Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹16.8 L+₹2.0 L (13.6%)Rejected-Finance OPP JASWANT PLAZA BAWA TRADING COMPANY CAMP ROAD TALAB TILLO JAMMU JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹16.9 L+₹2.1 L (14.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹18.2 L+₹3.4 L (23.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹20.4 L+₹5.7 L (38.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
16 Mar 2022, 6:00 pmClosed
GE SAMBA
GE SAMBA
REPAIRS TO LEAKAGE/ SEEPAGE ALONGWITH PERIODICAL SERVICES TO MD ACCN AT BHIM LINE AND CONVOY GROUND AND REPAIR TO DRAIN AND COMPOUND WALL IN ZONE I UNDER GE SAMBA
2022_MES_507320_1
GE/SMB/T-47/2021-22
Open Tender
Civil Works
Item Rate
180 days
SAMBA
CLASS E AND CAT a i
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹47,000
Yes
30 Mar 2022
16 Feb 2022
18 Mar 2022
16 Feb 2022
16 Mar 2022
3 Mar 2022
16 Feb 2022 - 19 Feb 2022
Amount
Demolition of plain cement concrete in ground floors or paving n.exc 15 cm thickness (Below or above ground level) complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Applying brushing neat cement slurry with 3.0 kg of cement per sqm. (b) Rendering 10mm thick in Cement mortar (1:3) on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (c) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried.
(d) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (e) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slope from lowest line of sloping roof towards ridge. (f) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed by Engr-In-Charge.
PCC 1:2:4 type B0 (12.5 mm graded crushed stone aggregates) as in roof padding for slopping purpose including mixing of liquid water proofing compound as per manufacture's instructions finished even and smooth without using extra cement ,complete all as specified and directed
PCC 1:2:4 type B-0(using 12.5 mm graded stone crushed aggregate) as in roof coving, coping, bed blocks etc at junction of parapet wall & roof, complete all as specified and directed.
Rotational moulded polye- thylene water storage tanks of capacity 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I & including dismentling old U/S tank, complete all as specified and as directed.
Rotational moulded polye- thylene water storage tanks of capacity 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I & incl dismentling old U/S tank,complete all as specified and as directed.
Disconnecting existing tanks, cap exc 250 ltr and not exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Disconnecting existing tanks, cap exc 500 ltr and not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
Taking down cement plaster/dado (terrazzo) on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrugbbing down with water etc,complete all as specified and as directed.
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and as directed.
Brick work with sub class 'B' burnt old size bricks straight or curved on plan exc. 6 m mean radius bult in CM 1:6 complete all as specified and as directed.
Rendering 15mm thick cement plaster in cement mortar 1:4 on on brick work or concrete and finished even and smooth (without using extra cement) complete all as specified and as directed.
Rendering 10 mm thick cement plaster in cement mortar 1:6 on on brick work or concrete and finished even and smooth (without using extra cement) complete all as specified and as directed.
Rendering 5 mm thick on concrete surfaces on ceiling surfaces in CM 1:3 surfaces finished even and smooth (without using extra cement) over a setting coat 5mm thick trowelled finish in CM 1:2 complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying two coat of cement base paint on old decorated surfaces complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying one coat of cement base paint on old decorated surfaces complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying two coat of weather coat paint (apex) over a coat of primer on old decorated surfaces complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of white wash complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying one coat of oil bound distemper on old decorated surfaces complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying two coat of oil bound distemper on old decorated surfaces complete all as specified and directed.
Preparation to new plastered surfaces of ceiling and applying three coats of white wash , complete all as specified and as directed.
Preparation of old plastered surfaces of ceiling and applying one coat white wash on old decorated surfaces complete all as specified and directed.
Preparation to new plastered surfaces of walls and applying three coats of white wash , complete all as specified and as directed.
Preparation of old plastered surfaces of walls and applying one coat white wash on old decorated surfaces complete all as specified and directed.
Preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified and directed.
Preparation of old steel or iron surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or euqivalent make of approved by GE cold applied.Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equavalent make as approved by GE, created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm. Lay Geotex of 45 GSM/fiber mesh simultaneously and paste it properly with overlap of 50mm. Allowed of first coat to dry for 10 to 12 hrs. Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller. Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note : Application of water proofing treatment will be done by authorised applicator only.
Plain Cement concrete 1:7:12 type F-2 (using 40 mm graded stone aggregate) as in sunken filling and mass concrete, complete all as specified and directed
25 mm thick cement concrete 1:2:4, Type B-1 (20 mm graded stone aggregate) as in sub-base of floor for tiles/Kota stone finished even & rough, complete all as specified and directed
Dismanting of floor hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
Non skid coloured ceramic tiles (1st quality) 7 to 8mm thick(square/rectangular joint free) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6, complete all as specified and directed
Glazed coloured ceramic tiles (1st quality) joint free in vertical surfaces of wall of size 450x350x7mm/350 x250 x 7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 on brick /concrete surfaces complete all as specified and directed .
Taking down cement plaster from chajjas or facia etc, incl. dismantling of damage conerete & repair the same with PCC 1:2:4 type B-0 (using 12.5mm crushed stone aggregate) on chajjas of any width and applying 10mm thick cement plaster in CM 1:3 mixed with water proofing compound(Water proofing compound shall be measured & paid separately) , finished even & smooth using extra cement, complete all as specified and as directed. Noe- Rate quoted shall be deemed to include for scaffolding/formwork for single/double story building of height 8.0 mtr and making good the disturbed surfaces.
Vitreous china ,Squatting pan 'Orissa' pattern size 580x440mm white with integral foot rest including all joints and making good to the floor etc fixed in repair ,complete all as specified and directed.
Vitreous china wash down water closet pan padestal pattern white, excluding fixing bolts, flushing cistern but including flush pipe, seat and cover, fixed in repairs complete all as specified and directed.
Vitreous china WHB size 550x400mm including cutting or pinning inends of brackets or erecting incl32mm dia waste pipe complete all as specified and directed
PVC valveless, 10 ltrs, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repair, complete all as specified and directed
C.P. Bib taps, long shank(Fancy type) 15mm bore cast copper alloy ,screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed
C.P. Stop valve (fancy type) 15mm bore,cast copper alloy screwed down,high pressure, screwed both ends for iron pipe or unions complete all as specified and directed
15 mm Ball Cock brass with external threads, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
15mm bore Brass C P (Fancy type) wall mixer for Hot & Cold water, screwed both ends for iron pipe or for unions and fixed in repairs.complete all as specified and directed
C.P. Angle valve (fancy type) 15mm bore,cast copper alloy screwed down,high pressure, screwed both ends for iron pipe or unions complete all as specified and directed
C.P. shower rose 125 mm size for 15 mm bore pipe, fixed in repair, complete all as specified and directed
C.P. pillar tap( fency type 15mm bore)cast copper alloy with capsten head CP screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shank and fly nuts screwed for iron pipe complete all as specified and directed.
PVC connection 15mm dia, 450mm long with brass nut complete all as specified and directed
CP brass grating with hole 150 mm dia as per sample to be fixed with white cement, complete all as specified and directed.
Dismantling of CI or Concrete drain pipes up to 150mm dia, jointed in cement mortar and taking out from trenches,if required complete all as specified and directed .
Taking down eaves gutters and PVC rainwater / drain pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning for refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed .
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in walls complete all as specified and directed
PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
PVC (SWR) 110mm bore bends any radius, complete all as specified and directed .
PVC (SWR) 75mm bore bends any radius, complete all as specified and directed .
PVC (SWR) 110mm bore bends any radius with access door, complete all as specified and directed .
PVC (SWR) 75mm bore vent cowl complete all as specified and directed
PVC (SWR) 110mm bore branch piece, single (single Y) equal or unequal, complete all as specified and directed .
Taking down GI pipe 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
Taking down GI pipe 20mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
G.I. pipe 15mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
G.I. pipe 15mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors, but except pipe complete all as specified and directed
G.I. pipe 20mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
G.I. pipe 20 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors, but except pipe complete all as specified and directed
Cutting chases,pining in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing steps, cills, sunshades ,shelves,lintels,etc.; and cutting chases for concealed water tubing or concealed conduit,wiring,etc,and making good cutting not exceeding 10 cm girth in brick walls. complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for , complete all as specified and directed.
Cleaning sludge and mud etc of any type and any position as in drains with an average depth 30 cm and 30 to 45 Cm in width as in foul smell. complete all as specified and directed.
PCC 1:3:6 type C-2 using 40mm graded stone aggregate as drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete with fair finished, complete all as specified and directed.
Raking out joints/pointing to brick work in walls or to bricks on edges in floors, surface channels etc built in cement mortar. complete all as specified and directed.
Raking out joints/pointing to walling of random rubble, or polygonal walling brought up to course , built in cement mortar, complete all as specified and directed.
Brick work with sub class 'B' burnt bricks straight or curved on plan exc. 6 m mean radius bult in CM 1:6, but except brick complete all as specified and directed.
Brick with Sub class B bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 , complete all as specified and directed.
Brick with Sub class B bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 ,but except brick ,complete all as specified and directed.
Flush plointing to brick massonry in CM 1:4,complete all as specified and directed.
Flush plointing to stone masonry massonry in CM 1:4,complete all as specified and directed.
RCC Precast 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in cover slabs (for drain & manholes etc) with plain faces, set in cement mortar 1:4 complete all as specified and directed.
RCC M-20 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas. etc complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, chajjjas, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) incl fair finished surface complete all as specified and directed.
PCC 1:3:6, 75 mm thick,Type C-2 (using 40mm graded crushed stone aggregates) as in sub base in floor, drain surface etc, complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 50 mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15 mm thick cement screed bed in CM 1:4 complete all as specified and as directed.
PCC 1:3:6 Type C-1 ( using 20mm graded crushed stone aggregate) for kerb /coping/edges etc complete all as specified and directed.
40 mm thick PCC 1:2:4 type B-0(using12.5 mm graded crushed stone aggregate) finished even and smooth using extra cement as in floor complete all as specified and directed.
Glass Dividing strips, 3 mm thick of 38 mm width inserted in position to confirm to design as in floor, complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S BAWA TRADING CO
M/S NAGAR BUILDERS
BALVINDER SINGH AND SONS
M/S RAJESH SHARMA & CO.
M/S RAMESHWAR ENGINEERS & BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .