Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.6 Cr | L1 | Accepted-AOC Bid of M/s Anil Kumar is accepted being lowest and reasonable |
| 2 | L2₹1.7 Cr+₹11.0 L (6.83%)Rejected-Finance | ₹1.7 Cr+₹11.0 L (6.83%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.8 Cr+₹18.3 L (11.4%)Rejected-Finance | ₹1.8 Cr+₹18.3 L (11.4%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹1.9 Cr+₹33.0 L (20.6%)Rejected-Finance | ₹1.9 Cr+₹33.0 L (20.6%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹2.0 Cr+₹41.5 L (25.8%)Rejected-Finance 401 7 32 CIVIL LINES ROORKEE HARIDWAR UP 247 667 | ROORKEE | HARIDWAR | UP | 247667 | ₹2.0 Cr+₹41.5 L (25.8%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹3.0 Cr
EMD Value
₹3.7 L
Closing Date
26 Sept 2020, 6:00 pmClosed
CHIEF ENGINEER PUNE ZONE
CE PUNE ZONE, DAKSHIN KAMAN MARG CAMP PUNE 411001
REPLACEMENT OF EXISTING WIRING WITH FRLS COPPER WIRE INCLUDING REPLACEMENT OF FITTINGS AND FIXTURE IN OFFRS AND JCOS ORS ACCN UNDER GE NORTH AND GE SOUTH PUNE
2020_MES_366835_1
84480E8
Open Tender
Electrical Maintenance Service
Item Rate
365 days
PUNE
AS PER TENDER
6 documents required · 6 mandatory
₹2,000
GE SOUTH PUNE
₹3.7 L
17 Nov 2020
6 Aug 2020
28 Sept 2020
6 Aug 2020
26 Sept 2020
21 Sept 2020
7 Aug 2020 - 14 Aug 2020
Amount
(Internal Electrification) Note: This is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Taking down carefully existing unserviceable aluminium/copper point wiring (light, fan, sockets or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials from site and making good disturbed surfaces of walls, floors, ceilings all as specified and as directed.
Taking down carefully existing unserviceable main switch /cutout/DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed.
Taking down carefully existing unserviceable sub main wiring of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, ceiling and floors as per the existing finishes all as specified and as directed.
M & L for point wiring (concealed type) complete with and including single core FRLS PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade ISI Marked drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as required at site, including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing painting including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked with GI metal flush boxes boxes thickness and depth of box as per Make Legrand Cat No. 6890 07 to 6890 09 of metal flush boxes and module of box from 1/2 module to 12/16 module or equivalent Make as given in Appx 'C', 1.2mm thick, 60mm deep with earth dollyduly, covered with modular white cover plate with frame suitable for modular type switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one light point/fan point and regulator/exhaust fan point, controlled by one, one way switch of 6 Amps.
All as per Serial Item No 5 above but for one 3/5 pin socket out let 6 Amps on the same board with other switches .
All as per Serial Item No 5 above but for one 3/5 pin socket out let 6 Amps on independent board .
All as per Serial Item No 5 above but for one light point controlled by two, two way switches 6 Amps.
All as per Serial Item No 5 above but for one bell point controlled by one bell switch 6 Amps.
M & L for point wiring (concealed type) complete with and including single core FRLS PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 2.5 Sqmm (36x0.30mm), 1100 volts grade drawn through and including heavy grade ISI Marked PVC rigid conduits 20 mm or higher dia as required at site, including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing painting including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked with GI metal flush boxes boxes thickness and depth of box as per Make Legrand Cat No. 6890 07 to 6890 09 of metal flush boxes and module of box from 1/2 module to 12/16 module or equivalent Make as given in Appx 'C', with earth dollyduly, covered with modular white cover plate with frame suitable for modular type switches, sockets, fan regulators etc including 2.5 Sqmm (36/0.30 mm) 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 3pin, 16 Amp socket outlet on independent board.
M & L for point wiring (concealed type) complete with and including single core FRLS PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 4 Sqmm (56x0.30mm), 1100 volts grade drawn through and including heavy grade ISI Marked PVC rigid conduits 20 mm or higher dia as required at site, including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing painting including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked with GI metal flush boxes boxes thickness and depth of box as per Make Legrand Cat No. 6890 07 to 6890 09 of metal flush boxes and module of box from 1/2 module to 12/16 module or equivalent Make as given in Appx 'C', with earth dollyduly, covered with modular white cover plate with frame suitable for modular type switches, sockets, fan regulators etc including 4Sqmm (56/0.30 mm) 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 3pin, 16 Amp socket outlet on independent board.
M & L for point wiring (concealed type) complete with and including single core FRLS PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade ISI Marked drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as required at site, including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing painting, including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked with GI sunken boxes 1.2mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one light point/fan point with regulator/ exhaust fan point controlled by one, one way switch 5 Amps.
All as per Serial Item No 12 above but for one 3/5 pin socket out let 5 Amps on the same board with other switches .
All as per Serial Item No 12 above but for one 3/5 pin socket out let 5 Amps on independent board .
All as per Serial Item No 12 above but for one light point controlled by two, two way switches 5 Amps.
All as per Serial Item No 12 above but for one bell point controlled by one bell switch 5 Amps.
M & L for point wiring (concealed type) complete with and including single core FRLS PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 2.5 Sqmm (22/0.30 mm) 1100 volts grade ISI Marked drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as required at site, including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing painting, including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked with GI sunken boxes 1.2mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 3 pin, 15 Amp socket outlet on independent board.
S&F switch modular bell push 6 Amps one way, one module 230 volts white /ivory finish all as specified and as direcrted
S&F Bell Push Flush type 5 Amps, 240 volts complete all as specified and as direcrted
S&F Bell, ding dong type suitable for AC 230 volts,50 Hz, single pole including removal of old uncserviceable one complete all as specified and directed.
S&F switch modular type 6 Amps one way, one module 230 volts white /ivory finish all as specified and as direcrted
S&F switch modular type 16 Amps one way, one module 230 volts with neon indicator white /ivory finish all as specified and as direcrted
S&F ceiling rose surface PVC 50 mm dia 3 terminals including PVC mounting block white/ ivory /urea finish complete all as specified and directed.
S&F modular type fan regulator 120 W, 2 module, step type,suitable for operation on 230Volts 50Hz AC supply complete all as specified and directed.
S&F socket outlet modular type 6 Amps, 2/3 pin combined two modules suitable for 3 pin/2 pin 5 Amp plug tops, complete all as specified and directed.
S&F socket outlet modular type 6A/16A , 2-3 Pin combined two modules suitable for 3 pin 6 Amp/16Amp plug tops, complete all as specified and directed.
S&F switch modular type 6 Amps two way one module 230 volts white /ivory finish all as specified and as direcrted
S&F switch piano flush type polycorbonate 5 Amps single pole one way, 230 volts all as specified and as direcrted
S&F socket outlet polycorbonate 5 Amps, 2 in 1 , 3 pin 5Amps flush type all as specified and as direcrted
S&F switch socket combination , 2 in 1, 6 Amps, multipurpose flush type complete all as specified and as direcrted
S&F switch socket combination, 2 in 1 , 5 and 15 Amps multipurpose flush type complete all as specified and as direcrted
S&F switch piano flush type polycorbonate 5 Amps single pole two way, 230 volts all as specified and as direcrted
S& F lamp holder, PVC/Polycorbonate type with back plate suitable for batten/ slanting fittings complete all as specified.
S& F highly efficient LED bulbs, 10w, used as a ready replacement for existing GLS/CFL direct fit lamp, in B-22 cap complete all as specified. Make as given in Appendix 'C'.
S&F sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amp rated bus bar 415 Volts, double door with magnatic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry and making good the disturbed portion as per existing adjacent finishes, complete all as specified and as directed. Make as given in Appendix 'C'.
S&F MCB Tripple pole and neutral 415 volts, 63 Amps to 100 Amps, 25KA, with extended terminals complete all as specified and directed. Make as given in Appendix 'C'.
S&F vertical 4 way TPN double door concealed MCCBs as incommer is 3 pole V-Tec of 100 Amps rating & 16KA breaking capacity. MCCB is prefitted at factory & including price of MCCB all as specified and directed by Engineer-in-charge . Cat No DBVTH004SD of L & T or equivalent in make as given in Appendix 'C'.
S&F vertical 8 way TPN double door concealed MCCBs as incommer is 3 pole V-Tec of 100 Amps rating & 16KA breaking capacity. MCCB is prefitted at factory & including price of MCCB all as specified and directed by Engineer-in-charge . Cat No DBVTH008SD of L & T or equivalent in make as given in Appendix 'C'.
S&F Distribution board sheet metal enclosure double door, factory made fixed in wall including cutting in brick /stone masonry wall and making good disturbed surfaces to match with the existing adjacent wall for mounting MCBs, 230 Volts with bus bars with front openable cover Single pole and neutral 8 way with Copper bus bar of suitable size as recommended by manufacturer complete all as specified and as directed.
S&F metal clad box suitable for 230Volts 50Hz AC supply three pin with MCB SP upto 32 Amps including removal of existing unserviceable one complete all as specified and as directed.
S&F MCB Single pole and neutral 240 volts 40-63 Amps 10 KA, 'C' curve complete all as specified and directed. Make as given in Appendix 'C'.
S&F MCB Single pole 240 volts 6 Amps to 32 Amps 10 KA, 'C' curve complete all as specified and directed. Make as given in Appendix 'C'.
M&L for brickwork with old size sub class 'B' bricks, straight or curved on plan exceeding 6m radius, built in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on brick or concrete surfaces and finished even and smooth without using extra cement complete all as specified & directed.
M & L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed by the Engineer-in-charge.
S & F sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6.0 Sqmm nominal area and drawing into PVC non metallic rigid PVC conduit of white/ivory color and its accessaries ISI marked as heavy duty of suitable size including cutting chasing for concealed submain wiring in any type of wall/floor/ ceiling and making good the disturbed surfaces and colour washing with existing colour etc including one run of PVC insulated 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and all as directed. Note- Two runs of 6.0 Sqmm cable, one run of 6.00 Sqmm cable for earth and one run of PVC Conduit will be measured as one run of PVC Conduit will be measured as one unit complete all as specified and as directed.
S & F sub main wiring with approved colour coding as per IS with two single core flame retardent (FRLS) PVC insulated heavy grade ISI marked including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing colour, unsheathed multistranded flexible copper conductor cable, of 4 sqmm and one single core 4 Sqmm flame retardent PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694 / 1990 drawn through & including non metalic rigid PVC conduit and accessories all as specified and as directed. Note: Two runs of 4Sqmm, one run of 4 Sqmm cable and one run of conduit will be measured as one unit.
S & F sub main wiring with approved colour coding as per IS with four single core flame retardent (FRLS) PVC insulated heavy grade ISI marked including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing colour, unsheathed multistranded flexible copper conductor cable, of 10 sqmm and two single core 10 Sqmm flame retardent PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694 / 1990 drawn through & including non metalic rigid PVC conduit and accessories all as specified and as directed. Note: Four runs of 10 Sqmm, two run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit.
S & F sub main wiring with approved colour coding as per IS with four single core flame retardent (FRLS) PVC insulated heavy grade ISI marked including cutting chasing in wall for concealed wiring in any type of wall/floor/ceiling and making good the disturbed surfaces and color washing with existing colour, unsheathed multistranded flexible copper conductor cable, of 6 sqmm and two single core 6 sqmm flame retardent PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694 / 1990 drawn through & including non metalic rigid PVC conduit and accessories all as specified and as directed. Note: Four runs of 6Sqmm, two run of 6Sqmm cable and one run of PVC conduit will be measured as one unit.
Supply and fix wall mounted LED 20 watts, LED batten for surface and pendant application, anodised extruded alluminium housing, high transmissitivity diffuser and high lumen output, 230 volts etc. complete with all accessories internally pre wired and necessary mounting arrangement, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make bajaj cat No BCLAB 20W or equivalent in make as given in Appendix 'C'. .
Supply and fix energy saving new generation 10 watts LED bulk head fitting IP65 luminaire with opel diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removalof old existing unserviceable tube light fitting complete all as specified and as directed. Make bajaj cat No BIBWP 10W or equivalent in make as given in Appendix 'C'. .
Supply and fix LED 10 watt batten aluminium extruded with decorative end caps including removal of old unserviceable T-8 type light fitting complete all as specified and as directed. Make bajaj cat No BCLSB 10 WH or equivalent in make as given in Appendix 'C'. .
Supply and fix energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 Watts with prewired and necessary mounting arrangment and provision of 2.5Sqmm three core copper conductor cable multistranded from ceiling rose to light fittings including necessary GI pipe medium grade bracket 600mm long bent to required shape and including taking down old unserviceable existing light fitting of any description complete all as directed by Engineer -in-Charge. Make bajaj cat No BCLST 25W LED I or equivalent in make as given in Appendix 'C'. .
Supply and fix decorative wall mounted luminaire made out of polycorbonate with unbreakable globe suitable for LED bulb and including provision of LED bulb10/11 Watt complete all as specified and as directed. Make Havells cat No LHGLO 6160099 or equivalent in make as given in Appendix 'C'. .
Taking down ceiling fan of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after cleaning dust, oiling, greasing etc including provision of flexible three core copper conductor wire of size 23/0.0076 from ceiling rose to connector of fan all as specified and as directed.
Dismantling and taking down old unserviceable Meter Enclosures including refixing the dismantled meter inside the new enclosures in suitable way for proper functioning, any type, any size and making good the disturbed surfaces, filling with brick work using old size sub class B bricks in cement mortar 1:4 , providing cement plaster with cement mortar 1:4 and finishing the plastered surfaces with two coats of cement base paint and replacement with new electric meter box suitable for single phase electric meter with MCB DP 32 Amps made out of 2mm thick CRCA MS sheet factory made Powder coated with locking arrangement with Pad Lock of Godrej or equivalent Make as given in Appx 'C', with transparant door for meter reading all as specified and as directed.
Dismantling and taking down old unserviceable meter box any type, any size and making good the disturbed surfaces, filling with brick work using old size sub class B bricks in cement mortar 1:4 , providing cement plaster with cement mortar 1:4 and finishing the plastered surfaces with two coats of cement base paint and replacement with new electric meter box suitable for three phase electric meter with MCB DP 32 Amps made out of 2mm thick CRCA MS sheet with transparant door for meter reading all as specified and as directed.
S & F for metal body exhaust fan, AC single phase, heavy duty, turbo force 240V of 200mm sweep with louvers including necessary connection of flexible copper cable from ceiling rose to fan connector complete all as specified and as directed. Make Bajaj Cat No maxma DX 8" or equivalent in make as given in Appendix 'C'.
M & L for cutting and making hole into or through cement concrete or stone masonry wall of thickness upto 45cm and girth 45 cm for fixing exhaust fan of size 300mm sweep & providing fastener grouted in wall four nos inside for fixing exhaust fan and four no outside for louvers and making good the with cement mortar 1:4 to match existing surfaces including lime wash all as specified and as directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing wire 4mm dia by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including RCC 1: 2 : 4 type B-1 earth pit with cover, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
ganesh electricals and airconditioners
SACKSON ENTERPRISES
DARSHAN CONSTRUCTION Co.
KHANDELWAL ASSOCIATES
SHAH BUILDERS
Mourya Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .