Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.7 L+₹1.3 L (4.72%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹28.8 L+₹1.4 L (4.95%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹29.3 L+₹1.9 L (6.84%)Rejected-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹29.9 L+₹2.5 L (9.17%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
13 Apr 2021, 6:00 pmClosed
CWE Rajouri
HQ CWE Rajouri PIN-900129 C/o 56 APO
PROVN OF STANDBY GENERATOR SETS FOR WEU AND SPECIAL REPAIR TO EXTERNAL ELECTRIFICATION AT DOU AT RAJOURI UNDER GE 862 EWS
2021_MES_430587_1
CANO-CWE/RAJ-73/2020-21
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR of GE 862 EWS
Class D category b(ii)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹72,000
Yes
27 May 2021
15 Mar 2021
15 Apr 2021
15 Mar 2021
13 Apr 2021
29 Mar 2021
Amount
Taking out existing underground/over head defective cable of any type and size from the trenches and from any other locations (including taking out of cable covers, pipes etc) complete all as directed.
Taking down carefully existing unserviceable light fitting 150/250/400 watt CFL/HP/SV from existing location like pole, wall etc. complete all as specified and directed.
LED flood light luminaire 150 watts with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection comple with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc. at any height providing clamps, nuts, bolts and washers etc. including removing old unserviceable items complete all as specified and as directed by Engineer-in-Charge. Make :Crompton cat part No LFLN-150-CDL/60 or equivalent cat part of make as specified in Appx- E to P.S.
LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete all as specified and directed. Make:-Crompton model No.LSTS-45-CDL-1 or equivalent cat part of make as specified in Appx- E to P.S.
FRP looping box of size 250x200x105mm with connector and comprising of MCB SP 6 Amps, ISI marked,240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/ wall etc and including removing old unserviceable item complete all as specified and directed. Make:- National/Sintex
GI pipe bracket of size 25 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clamps 2 Nos of length as required at site to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts,bolts & washers and removing of old unserviceable item complete all as specified and directed.
Copper conductor cable, PVC insulated, sheathed, flexible, multistranded,ISI marked, 1100 volts grade, 3 core 2.5 sqmm and including connection and testing inlcuding removing old unserviceable cable, complete all as specified and directed.
LT aerial bunched cable 11000 V grade fixed on overhead lines on 9 meter steel poles having three power core and one neutral-cum-messenger core of stranded compacted circular aluminium black coloured XLPE insulated & core identification by ridges, one, two, three and four respectively. Compacted circular aluminium conductor, (3 x50 sqmm, + 1x 35 sqmm) . Messenger-cum-neutral wire should be of stranded compacted circular alluminium alloy conductor confirming to IS 8130/1984, IS-398 (Part-IV)/1979 and IS-14255/1995 with upto date amendments, if any including accessories required for hanging and existing connections ie achor clamp (3-Bolts and 2 Bolt type), Eye hook with suspension clamp assembly, pole clamp, insulation piercing connectors with cover or PG connectors with insulation cover , water proof pre-insulated hexagonal compression connectors and lugs etc complete all as specified and directed by Engr-in-Charge.
LT XLPE cable insulated, galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 50 sqmm; 3.5 core laid in trenches/pipes/ducts/ walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed. Note for item No 9 to 13 :- (i) Excavation & Earth work, sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE.
LT XLPE cable insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 35 sqmm; 3.5 core laid in trenches/pipes/ducts/ walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed.
LT XLPE cable insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 25 sqmm; 4 core laid in trenches/pipes/ducts/ walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed.
LT XLPE cable insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 16 sqmm; 4 core laid in trenches/pipes/ducts/ walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed.
LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 10 sqmm; 4 core laid in trenches/pipes/ducts/ walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing, complete all as specified and directed.
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site contd to item No-14.01.....
requirement. The minimum depth, height, width of panel is 450x1800x1500 mm respectively, minimum clearance from ground level is 450mm with & including removing old unserviceable panel complete all as specified and directed and comprising of following :- Note:- (i) contractor shall provide CPRI certification of the panel. (ii) Make for MCCB :-Schneider/L&T/Legrand/Havells (ISI Marked) .Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee (a) MCCB 200Amps 70-100%,4 Pole, 35KA, 415 volts, 50Hz-01 No. (b) MCCB 100 Amps, 4 pole, 25 KA, 415 volts, 50Hz-1 No. (c) MCB 64 Amps FP,10 KA,415 volts, 50Hz-1 No. (d) Digital voltmeter, Digital Ammeter,with CTs & ASS-01 set,with VSS -01 set. (e) LED phase indication lamps RYB-01 set. (f) Aluminium bus bar TPN 300 Amps rating -01 set
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site contd to item No-15.01.....
requirement. The minimum depth, height, width of panel is 450x1800x1500 mm respectively, minimum clearance from ground level is 450mm with & including removing old unserviceable panel complete all as specified and directed and comprising of following :- Note:- (i) contractor shall provide CPRI certification of the panel. (ii) Make for MCCB :-Schneider/L&T/Legrand/Havells (ISI Marked) .Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee (a) MCCB 100Amps 70-100%,4 Pole, 25KA, 415 volts, 50Hz-01 No. (b) MCCB 63 Amps 70-100%,4 Pole, 25KA, 415 volts, 50Hz-01 No. (c) MCB 64 Amps FP,10 KA, 415 volts, 50Hz-2 Nos. (d) Digital voltmeter, Digital Ammeter,with CTs & ASS-01 set,with VSS -01 set. (e) LED phase indication lamps RYB-01 set. (f) Aluminium bus bar TPN 200 Amps rating -01 set
On-load change over switch 160Amps, 4pole,3 phase, 415V, 50Hz, front handle operated, open execution type including enclosed in 3.2 mm thick CRCA sheet metal enclosure , powder coated, weather proof fixed on MS angle iron frame of suitable size duly painted and mounted above the floor level with necessary PCC foundation/platform in PCC 1:2:4 type B1 and including connecting of incomming and outgoing cables with suitable lugs,glands,nuts,bolts and washers fixed in replacement, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 X 4 mm from earth electrode to test point or up-to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore light grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade, GI funnel with wire mesh, including char-coal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C-1, RCC cover 1:2:4 type B-1, excavation in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
Supply and erecting in true vertical position steel tubular swaged pole, 9 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-31 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing including taking down of old existing broken/cracked pre stresed concrete pole 9 metres long complete all as specified and directed. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch 'A').
Stay assembly complete with accessories and GI stay rod 20 mm dia 1900 long, stay plate 300mm x 300mm x 6mm, galvanised thimbles, galvanised steel 14mm dia 400mm long stay bow and GI nuts, washers including loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No 1 on Ser Page No 495 of MES Schedule Part-I (2009) complete including dismantling stay assembly complete all as specified and directed. Note : Stay clamp, stay wire, excavation and earth work and concrete for stay pit shall be measured and paid separately.
Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire of size 4 mm dia from earth electrode to test point/equipment or up to 7.5 metres whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh, GI light grade protection pipe 20 mm including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1,with suitable handle, angle iron made of frame out of angle iron of size 40x40x4 mm, including excavation/earth work in any strata and returning filling, removal of surplus soil and testing for required value including removing unserviceable item complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 Gde E-165 including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of red oxide primer coat and two coat of silver paint all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in any type of soil, complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness 18 cm shall be made and paid.
Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
GI pipe 50mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables including removing old unserviceable pipe & fittings, complete all as specified and directed.
PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
PCC 1:2:4 (nominal mix) type C1 using 20mm graded crushed stone aggregate, as in coping of poles and the like complete including necessary form work all as specified and directed.
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set coupled with alternator AC to give continuous output of 15 KVA/12KW at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine, Air cooled, mounted on common base frame complete with in built fuel tank (service tank) of adequate capacity with fuel line, built in electronic governor & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, micro processed based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under-mentioned technical specifications confirming to BS:5514 & IS 10000 complete in all respect with following accessories, parts all as specified & directed. Make:M/S Kirloskar GEN Set model No- KG1-15AS and equivalent in Cummins/Ashok Leyland contd to item No-30.01....
(a) DIESEL ENGINE : 2 cylinders, Water cooled at 1500 RPM under NTP conditions IS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for one hour in 12 hrs of continuous operation with the following accessories Make:M/S Kirloskar Engine model No- HA294 G1 and equivalent in Cummins/Ashok Leyland (i) Radiator with blower fan or heat exchanger with guard . (ii) Pipe coupling for engine cooling system piping (iii) Corrosion inhibitor coolant (iv) Paper element filters-(a) Fuel (b) Lube oil (c) By Pass (v) Fly wheel housing and fly wheel to suit (vi) Engine bearing mechanism in fly wheel housing (vii) shut off coil with safety for LLOP /HWT./ Over speed. (viii) Dry type air cleaners and vacuum indicators . (ix) Residential silencers. (x) Stainless steel exhaust flexible bellows. (xi) Motor driven priming pump. contd to item No-30.02
(xii) Electric starter. (xiii) Battery charging alternator. (xiv) Exhaust piping made out of STIC C class MS Pipe inclusive of all accessories and hardware , necessary support as per manufacturer’s recommendations to sustain back pressure with rain cap (xv) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe. (xvi) First fill of oil coolant and diesel during commission and 12 hours testing. (xvii) Interconnecting copper cabling of adequate capacity between batteries and controller. (xiii) Fuel pipe. Fuel Tank- 8 hours full load diesel storage capacity inbuilt fuel tank with mounting brackets factory fabricated made of MS sheet with level indicator fuel inlet , fuel outlet , air vent, drain plug,inlet arrangement filling from exterior of canopy etc. (xix) Battery :- 120 AH,12 Volts maintenance free battery of Qty-1 Nos with leads and terminal. Make-Exide/Amaron/Amco. contd to item No-30.03.....
(xx) PCC Foundation :- Civil work and PCC foundation for installation DG Set as per manufacturers instruction. (b) ALTRERNATOR : 15 KVA/12 KW at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BS5000, IEC 34/1, ISO 8528, BS5514, ISO3046, suitable for above mentioned diesel engine complete all as specified and directed . (c) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) having size not less than 1740mm lengthX1050mm widthX1474 mm height for the above 15 KVA DG set to reduce noise level to 75 db (A), measured at 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-: (i) Sound proof insulation 100mm thick Rock wool (Density 65 Kg/cum) (ii) Outer body: Not less than 1.6 mm thick CRCA. (iii) Door 1.6 mm thick CRCA contd to item No-30.04.......
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set coupled with alternator AC to give continuous output of 30 KVA/24KW at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine, water cooled, mounted on common base frame complete with in built fuel tank (service tank) of adequate capacity with fuel line, built in electronic governor & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, micro processed based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under-mentioned technical specifications confirming to BS:5514 & IS 10000 complete in all respect with following accessories, parts all as specified & directed. Make:M/S Kirloskar GEN Set model No- KG1-30WS and equivalent in Cummins/Ashok Leyland
(a) DIESEL ENGINE : 3 cylinders, Water cooled at 1500 RPM under NTP conditions IS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for one hour in 12 hrs of continuous operation with the following accessories Make:M/S Kirloskar Engine model No- 3R1040T G1 and equivalent in Cummins/Ashok Leyland (i) Radiator with blower fan or heat exchanger with guard . (ii) Pipe coupling for engine cooling system piping (iii) Corrosion inhibitor coolant (iv) Paper element filters-(a) Fuel (b) Lube oil (c) By Pass (v) Fly wheel housing and fly wheel to suit (vi) Engine bearing mechanism in fly wheel housing (vii) shut off coil with safety for LLOP /HWT./ Over speed. (viii) Dry type air cleaners and vacuum indicators . (ix) Residential silencers. (x) Stainless steel exhaust flexible bellows. (xi) Motor driven priming pump. contd to item No-31.02........
(xii) Electric starter. (xiii) Battery charging alternator. (xiv) Exhaust piping made out of STIC C class MS Pipe inclusive of all accessories and hardware , necessary support as per manufacturer’s recommendations to sustain back pressure with rain cap (xv) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe. (xvi) First fill of oil coolant and diesel during commission and 12 hours testing. (xvii) Interconnecting copper cabling of adequate capacity between batteries and controller. (xviii) Fuel pipe. Fuel Tank_ 8 hours full load diesel storage capacity inbuilt fuel tank with mounting brackets factory fabricated made of MS sheet with level indicator fuel inlet , fuel outlet , air vent, drain plug,inlet arrangement filling from exterior of canopy etc. (xix) Battery :- 120 AH,12 Volts maintenance free battery of Qty-1 Nos with leads and terminal. Make-Exide/Amaron/Amco contd to item No-31.03.......
(xx) PCC Foundation :- Civil work and PCC foundation for installation DG Set as per manufacturers instruction. (b) ALTRERNATOR : 30 KVA/24 KW at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BS5000, IEC 34/1, ISO 8528, BS5514, ISO3046, suitable for above mentioned diesel engine complete all as specified and directed . (c) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) having size not less than 2500mm lengthX950mm widthX1294 mm height for the above 15 KVA DG set to reduce noise level to 75 db (A), measured at 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-: (i) Sound proof insulation 100mm thick Rock wool (Density 65 Kg/cum) (ii) Outer body: Not less than 1.6 mm thick CRCA. (iii) Door 1.6 mm thick CRCA contd to item No-31.04........
Stay wire stranded 7/3.15mm including stay clamp and fixing arrangement complete all as specified
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation contd to item No-33.01
design subject to approval of GE as per site requirement. The minimum depth, height, width of panel is 450x1500x1200 mm respectively, minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed and comprising of following :- Note :- (i) contractor shall provide CPRI certification of the panel. (ii) All items incorporated in panel is ISI marked or IS specification . Make for MCCB :-Schneider/L&T/Legrand/Standard. Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee (a) MCCB 100 Amps 70-100%,4 Pole, 36 KA, 415 volts, 50Hz-01 No. (b) MCCB 63 Amps,4 Pole,16 KA, 415 volts, 50Hz-1 No. (c) MCB 40 Amps,SP,10 KA,415 volts,50Hz-4 Nos. (d) Digital voltmeter, Digital Ammeter with CTs & ASS-01 set, with VSS -01 set. (e) LED phase indication lamps RYB-01 set. (f) Aluminium bus bar TPN 200 Amps rating -01 set
M/S PARSHOTAM KUMAR GUPTA
M/S NARAYAN CONSTRUCTION
vijay kumar gupta and co
Jiwan Singh
M/s R V Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .