| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 CrAccepted-AOC | ₹10.5 Cr | L1 | Accepted-AOC Due to Lowest Rates |
| 2 | L2₹12.6 CrRejected-Finance 76 21 GURUDWARA ROAD NAKA HINDOLA LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | ₹12.6 Cr | L2 | Rejected-Finance Second Lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 4 | Not Admitted-Fee/PreQual/Technical 2ND FLOOR PADMA TOWER 1 5 RAJENDRA PLACE NEW DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | - | - | Not Admitted-Fee/PreQual/Technical Others-1. Pending Litigation History is not as per Tender requirement.
2. Non Banned / Non Blacklisted Notary Certificate / Affidavit since last five years is not as per Tender requirement. |
Tender Value
Refer Docs
EMD Value
₹22.3 L
Closing Date
24 Jul 2023, 5:00 pmClosed
Superintending Engineer
Office of The Superintending Engineer 11th E/M Circle, P.W.D., 107-Nehru Colony (Phase-II), Dharmpur, Dehradun
Supply,Installation,Testing and commissioning of Beautification and Electrification Works for Selected temple,Ghats,Mata Janki,Ram Jhula Suspension Bridge, shri Hemkunt sahib Gurdwara, Natraj Chowk, and Road Lighting from Airport Tiraha to Rishikesh
2023_pwd_59923_1
1790/7CB(I)-11/2023-24 Dated 26.05.2023
Open Tender
Electrical Works
150 days
Jollygrant, Rishikesh, Munikireti, Swargashram
Please refer Tender Documents
2 documents required · 2 mandatory
₹5,900
Executive Engineer, E/M Division, PWD, Rishikesh
₹22.3 L
Dehradun
4 Apr 2024
19 Jun 2023
25 Jul 2023
19 Jun 2023
24 Jul 2023
19 Jun 2023
19 Jun 2023 - 29 Jun 2023
30 Jun 2023
Amount
MATA JANKI SETU (A)
SITC OF PIXEL LIGHT, 2W RGB LED (3 IN 1),PIXEL PITCH LENGTH - 300MM, EACH PIXEL WITH 8 DOTS LED SMD3535, EACH PIXEL SHOULD BE IP66/67, MATERIAL - POLY CARBONATE, TRANSPARENCY RATE - 90%, SUITABLE IP68 CONECTORS, LUMINAIRE CONTROLS VIA SPI PROTOCOL WITH AUTO ADDRESSING FOR EASY CONFIGURATION. THE CONNECTIVITY SHOULD BE OF A DAISY CHAIN TOPOLOGY, ALLOWING EASY INSTALLATON TO FORM LONG RUN LENGTHS WITH THE 2MM DIA STEEL WIRE ALONG WITH U CLAMP TO SUPPORTING THE EACH PIXEL .REMOTE DEVICE MANAGEMENT CIRCUITS SHOULD BE BUILT INTO EACH LUMINAIRE TO ENABLES EXTENSIVE CONTROL AND MONITORING OF THE ENTIRE LIGHTING INSTALLATION, INSTALLATION CLAMPS, 5 CORE/CAT-6 OR SUITABLE CONTROL CABLES UV AND WEATHER PROOF, OTHER REQUIRED ACCESSORIES, HARDWARE, IP67 POWER SUPPLY, CONTROLLERS, SUBCONTROLLER AS REQUIRED. THE SIZE OF PIXEL SHOULD ≤ 26MM DIA., 32MM HEIGHT. MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE TO COMPLETE THE JOB IN ALL RESPECTS. AS PER TECHNICAL SPECIFICATION.
Programming and troubleshooting of the dynamic pixel controlled lights which must include Understanding the exact project requirements in terms of deliverable and evaluation to site conditions, Making a Mapping file after considering all the constraints of the site conditions and defining the final architecture. Also preparing the project/programme file for each site, suitable placement of the driver to control the data losses, defining the positions of sub controller and main controller with seamless integration. Addressing to every Pixel , Sub Controller, Content creation of Lord Shiva and Lord Ram themes, Making Minimum 20 themes including Lord Ram and Lord Shiva as per the instruction of engineer in charge. Maintaining the scenes for 5 years in case of any issue related to malfunctioning. The entire system should be compatible with light and sound show for future requirement of the Project. together It should be capable of capturing content.Original windows 10 embedded with i7 six core CPU with Rugged cooling system.with 16GB, RAM 02 Nos 512SSD,drives raid 0 drive for media playback, 01 Nos. 256 GB SSD for Operating It should a lso have genlock and framelock capability. Should a lso have Art-net Ethernet in/out. to complete the job with all respects.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness.
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 50 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 4C X 25 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 4C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 4C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 50 sq. mm (35mm)
4 X 25 sq. mm (28mm)
4 X 16 sq. mm (28mm)
4 X 10 sq. mm (25mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/L of 50 mm dia. HDPE pipe SDR 11 ISI
S/L of 32 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber.including Connection.
Supply and fixing of Shockproof and rustproof, 100% Water Proof, Mounting arrangement, Rot-proof and termite resistant,Cable entry from the bottom/sides SMC Junction Box.(450 x 375 x 200)
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: 3 Phase,415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 100 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 63A 4P MCCB (TM-R) (18 kA) - 1no., 60A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 63/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 25A TPN MCB(10kA) - 6 Nos.
RAM JHULA (B)
SITC OF PIXEL LIGHT, 2W RGB LED (3 IN 1),PIXEL PITCH LENGTH - 300MM, EACH PIXEL WITH 8 DOTS LED SMD3535, EACH PIXEL SHOULD BE IP66/67, MATERIAL - POLY CARBONATE, TRANSPARENCY RATE - 90%, SUITABLE IP68 CONECTORS, LUMINAIRE CONTROLS VIA SPI PROTOCOL WITH AUTO ADDRESSING FOR EASY CONFIGURATION. THE CONNECTIVITY SHOULD BE OF A DAISY CHAIN TOPOLOGY, ALLOWING EASY INSTALLATON TO FORM LONG RUN LENGTHS WITH THE 2MM DIA STEEL WIRE ALONG WITH U CLAMP TO SUPPORTING THE EACH PIXEL .REMOTE DEVICE MANAGEMENT CIRCUITS SHOULD BE BUILT INTO EACH LUMINAIRE TO ENABLES EXTENSIVE CONTROL AND MONITORING OF THE ENTIRE LIGHTING INSTALLATION, INSTALLATION CLAMPS, 5 CORE/CAT-6 OR SUITABLE CONTROL CABLES UV AND WEATHER PROOF, OTHER REQUIRED ACCESSORIES, HARDWARE, IP67 POWER SUPPLY, CONTROLLERS, SUBCONTROLLER AS REQUIRED. THE SIZE OF PIXEL SHOULD ≤ 26MM DIA., 32MM HEIGHT. MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE TO COMPLETE THE JOB IN ALL RESPECTS. AS PER TECHNICAL SPECIFICATION.
Programming and troubleshooting of the dynamic pixel controlled lights which must include Understanding the exact project requirements in terms of deliverable and evaluation to site conditions, Making a Mapping file after considering all the constraints of the site conditions and defining the final architecture. Also preparing the project/programme file for each site, suitable placement of the driver to control the data losses, defining the positions of sub controller and main controller with seamless integration. Addressing to every Pixel , Sub Controller, Content creation of Lord Shiva and Lord Ram themes, Making Minimum 20 themes including Lord Ram and Lord Shiva as per the instruction of engineer in charge. Maintaining the scenes for 5 years in case of any issue related to malfunctioning. The entire system should be compatible with light and sound show for future requirement of the Project. together It should be capable of capturing content.Original windows 10 embedded with i7 six core CPU with Rugged cooling system.with 16GB, RAM 02 Nos 512SSD,drives raid 0 drive for media playback, 01 Nos. 256 GB SSD for Operating It should a lso have genlock and framelock capability. Should a lso have Art-net Ethernet in/out. to complete the job with all respects.
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE (THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 25 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 4C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 4C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 25 sq. mm (28mm)
4 X 16 sq. mm (28mm)
4 X 10 sq. mm (25mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia. HDPE pipe SDR 11 ISI
SITC of Cable junction box IP66/667 Weather proof for outdoor installation cable size 10-25 sq mm with knockouts for cable entry with terminal Box size - 205 x 255 x 112 mm.
Supply and fixing of Shockproof and rustproof, 100% Water Proof, Mounting arrangement, Rot-proof and termite resistant,Cable entry from the bottom/sides SMC Junction Box.(450 x 375 x 200)
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: 3 Phase,415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium three phase and neutral busbars rated at 100 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 63A 4P MCCB (TM-R) (18 kA) - 1no., 60A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 63/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 25A TPN MCB(10kA) - 4 Nos.
Dismantelling, Loading and Shifting of Existing Strip Lights,Switchgear & Wires in Complete Ram Jhula Bridge.
SHRI HEMKUNT SHAHIB GURDWARA (C)
SITC OF 1000MM LONG LINEAR LIGHT (IP66) WITH FOLLOWING SPECIFICATIONS: 1500 LM (TOLERENCE IN LUMENS ± 10%), 10° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 4000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED DRIVER SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 1500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 24W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:3000 LM (TOLERENCE IN LUMENS ±10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 4000K CCT ( TOLERENCE ±150K), OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 3000 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 32 mm dia. PVC HD Conduit pipe .
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 3 Nos.
BHOOTHNATH TEMPLE (D)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:3000 LM (TOLERENCE IN LUMENS ±10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 3000 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 16 sq. mm (22 mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 25 mm dia. PVC HD Conduit pipe .
S/L of 32 mm dia. PVC HD Conduit pipe .
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 4 Nos.
PRACHIN SHIDHPEETH MA BHADRAKALI TEMPLE (E)
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:3000 LM (TOLERENCE IN LUMENS ±10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 3000 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect.as per Technical Specification.
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC of EXTERIOR RATED, 4 METER HIGH POLE MADE IN MS SQUARE PIPE SECTIONS 450MM X 450MM WITH MS 10SWG SHEET, MS JAALI WITH ACRYLIC INSIDE. 80 WATTS PER METER LED, RGBW, 360 SYMMETRICAL OPTICS. THIS MOUNTING STEEL PLATE ALONG WITH FOUNDATION BOLTS OF SUITABLE SIZE TO BE USED FOR ENSURING FIRM GROUTING INTO THE SPECIALLY DESIGNED RCC FOUNDATION. WIND PRESSURE CALCULATION AS PER IS 875(PART-3) & STRUCTURAL CALCULATION REPORT AS PER EN40 SHOULD BE SUBMITTED TO VERIFY THE POLE DESIGN. POLE MUST BE PAINTED IN 3 LAYER COATING(COATING THICKNESS-100 MICRONS MINIMUM) IN WHICH 1ST LAYER WITH ETCH PRIMER, 2ND LAYER WITH EPOXY PRIMER & 3RD FINAL LAYER WITH PU PAINT - CUSTOMIZED COLOUR METALLAIC GREY, THIS INCLUDES ALL THE REQUIRED HARDWARE/ SOFTWARE/ CONTROLLER ETC TO MAKE OPERATIONAL OF THE LIGHT FIXTURE (ALL THE TECHNICAL PARAMETERS OF THE LUMINAIRE NEED APPROVAL FROM THE LIGHTING CONSULTANT) Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 25 mm dia. PVC HD Conduit pipe .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 2 Nos.
RELATED GHAT IN REVER FRONT MAIN RISHIKESH + (NEERAJ GANGA HERITAGE) (F)
SITC OF EXTERIOR RATED CATENARY MOUNTED 10W LIGHTING FIXTURE (IP 66) WITH FOLLOWING SPECIFICATION:1000 LUMENS (TOLERENCE IN LUMENS ±10%), 20° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER(IP 65) OPERATING INPUT RANGE BETWEEN 100VAC TO 270VAC. LUMENS WITH A SNOOT AS GLARE PROTECTION.. SALT SPRAY TESTING OF 90 HOURS WITH RELEVANT REPORTS. SHAPE - ROUND, DIA. ≤ 90 MM . CRI > 85.LUMINAIRE SHOULD BE IP66 & IK06 . DIE CAST ALUMINIUM HOUSING. MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE (ALL THE LUMINAIRES, ANTI GLARE ACCESSORIES, MOUNTING ARRANGMENT (10 METER HIGH POLES - 28 NO'S, POLE HOOKS ,TURN BUCKLES, ROPE CLIP, ROPE THIMBLE, SS ROPE, AVERAGE SS ROPE LENGTH AS PER ATTACHED DETAILED DRAWING, SS CABLE TIES,ETC) AND OTHER REQUIRED ATTACHEMNTS TO BE APPROVED BY LIGHTING CONSULTANTS). Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect.as per Technical Specification.
SITC OF 4 METER HIGH DECORATIVE POLE WITH DECORATIVE POSTTOP FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 4500 LM (TOLERENCE IN LUMENS ± 10%), ASYMMTERICAL OPTICS, 3000K CCT (TOLERENCE IN CCT ±150K),OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 4500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 50W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect.as per Technical Specification.
S/F OF ALUMINUM TUBE, SECTION SIZE- 25MM X 25MM X 2MM, POWDER COATED WITH SUITABLE ACCESSORIES, FOR LAYING ELECTRICAL CABLES AND SUITABLE FOR INSTALLION FOR LIGHTING FIXTURES. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect.
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 4C X 6 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 10 sq. mm (25mm)
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/F of 6 sq mm AL Lug for AL Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia GI pipe Medium Class.
S/L of 25 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 32A 3P MCCB (TM-R) (18 kA) - 1no., 32A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 4 Nos.
(YOG NIKETAN GUEST HOUSE) + (KRISHNA TEMPLE) (G)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.(YOG NIKETAN GUEST HOUSE)
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.(YOG NIKETAN GUEST HOUSE)
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.(YOG NIKETAN GUEST HOUSE)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification. (KRISHNA TEMPLE)
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.(KRISHNA TEMPLE)
SITC OF 500MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE (THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE)WITH FOLLOWING SPECIFICATIONS: 1500 LM (TOLERENCE IN LUMENS ± 10%), 10°X50° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED DRIVER SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 1500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 24W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification. (KRISHNA TEMPLE)
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:750 LM (TOLERENCE IN LUMENS ±10%), 10° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), BLUE COLOR, OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 750 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.(KRISHNA TEMPLE)
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia GI pipe Medium Class.
S/L of 32 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 4 Nos.
(OMKARANAND GANGA SADAN) + (SWAMI SHIVANAND SMARK DWAR) (H)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification. (OMKARANAND GANGA SADAN)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification .(SWAMI SHIVANAND SMARK DWAR)
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification. (SWAMI SHIVANAND SMARK DWAR)
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification. (SWAMI SHIVANAND SMARK DWAR)
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia GI pipe Medium Class.
S/L of 32 mm dia. PVC HD Conduit pipe
S/L of 25 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 3 Nos.
NATRAJ CHOWK (INDRAMANI BADONI) (I)
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:3000 LM (TOLERENCE IN LUMENS ±10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 3000 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:750 LM (TOLERENCE IN LUMENS ±10%), 10° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), BLUE COLOR, OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 750 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWAR .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC of EXTERIOR RATED, 4 METER HIGH POLE MADE IN MS SQUARE PIPE SECTIONS 450MM X 450MM WITH MS 10SWG SHEET, MS JAALI WITH ACRYLIC INSIDE. 80 WATTS PER METER LED, RGBW, 360 SYMMETRICAL OPTICS. THIS MOUNTING STEEL PLATE ALONG WITH FOUNDATION BOLTS OF SUITABLE SIZE TO BE USED FOR ENSURING FIRM GROUTING INTO THE SPECIALLY DESIGNED RCC FOUNDATION. WIND PRESSURE CALCULATION AS PER IS 875(PART-3) & STRUCTURAL CALCULATION REPORT AS PER EN40 SHOULD BE SUBMITTED TO VERIFY THE POLE DESIGN. POLE MUST BE PAINTED IN 3 LAYER COATING(COATING THICKNESS-100 MICRONS MINIMUM) IN WHICH 1ST LAYER WITH ETCH PRIMER, 2ND LAYER WITH EPOXY PRIMER & 3RD FINAL LAYER WITH PU PAINT - CUSTOMIZED COLOUR METALLAIC GREY, THIS INCLUDES ALL THE REQUIRED HARDWARE/ SOFTWARE/ CONTROLLER ETC TO MAKE OPERATIONAL OF THE LIGHT FIXTURE (ALL THE TECHNICAL PARAMETERS OF THE LUMINAIRE NEED APPROVAL FROM THE LIGHTING CONSULTANT) nstallation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 40 mm dia GI pipe Medium Class.
S/L of 25 mm dia. PVC HD Conduit pipe
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 2 Nos.
PARMARTH NITETAN + GEETA BHAWAN (J)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect.as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia GI pipe Medium Class.
S/L of 32 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 3 Nos.
ARTI ASTHAL (K)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:750 LM (TOLERENCE IN LUMENS ±10%), 10° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), BLUE COLOR, OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 750 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:3000 LM (TOLERENCE IN LUMENS ±10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 3000 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect.as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:3000 LM (TOLERENCE IN LUMENS ±10%), 10° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 2200K CCT ( TOLERENCE ±150K), OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 3000 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (19 mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 25 mm dia. PVC HD Conduit pipe
S/L of 32 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 32A 3P MCCB (TM-R) (18 kA) - 1no., 32A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 6 Nos.
PARMARTH NITETAN GHAT + GEETA BHAWAN GHAT (L)
SITC OF EXTERIOR RATED CATENARY MOUNTED 10W LIGHTING FIXTURE (IP 66) WITH FOLLOWING SPECIFICATION:1000 LUMENS (TOLERENCE IN LUMENS ±10%), 20° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER(IP 65) OPERATING INPUT RANGE BETWEEN 100VAC TO 270VAC. LUMENS WITH A SNOOT AS GLARE PROTECTION.. SALT SPRAY TESTING OF 90 HOURS WITH RELEVANT REPORTS. SHAPE - ROUND, DIA. ≤ 90 MM . CRI > 85.LUMINAIRE SHOULD BE IP66 & IK06 . DIE CAST ALUMINIUM HOUSING. MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE (ALL THE LUMINAIRES, ANTI GLARE ACCESSORIES, MOUNTING ARRANGMENT (10 METER HIGH POLES - 28 NO'S, POLE HOOKS ,TURN BUCKLES, ROPE CLIP, ROPE THIMBLE, SS ROPE, AVERAGE SS ROPE LENGTH AS PER ATTACHED DETAILED DRAWING SS CABLE TIES,ETC) AND OTHER REQUIRED ATTACHEMNTS TO BE APPROVED BY LIGHTING CONSULTANTS). Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2C X 16 sq. mm (22mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia GI pipe Medium Class.
S/L of 25 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 6 Nos.
LAXMI NARAYAN GHAT+RAM JHULA GHAT+GANGA MANDIR (M)
SITC OF EXTERIOR RATED CATENARY MOUNTED 10W LIGHTING FIXTURE (IP 66) WITH FOLLOWING SPECIFICATION:1000 LUMENS (TOLERENCE IN LUMENS ±10%), 20° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER(IP 65) OPERATING INPUT RANGE BETWEEN 100VAC TO 270VAC. LUMENS WITH A SNOOT AS GLARE PROTECTION.. SALT SPRAY TESTING OF 90 HOURS WITH RELEVANT REPORTS. SHAPE - ROUND, DIA. ≤ 90 MM . CRI > 85.LUMINAIRE SHOULD BE IP66 & IK06 .DIE CAST ALUMINIUM HOUSING. MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE (ALL THE LUMINAIRES, ANTI GLARE ACCESSORIES, MOUNTING ARRANGMENT( 10 METER HIGH POLES - 34 NO'S, POLE HOOKS ,TURN BUCKLES, ROPE CLIP, ROPE THIMBLE, SS ROPE, AVERAGE SS ROPE LENGTH AS PER ATTACHED DETAILED DRAWING, SS CABLE TIES,ETC) AND OTHER REQUIRED ATTACHEMNTS TO BE APPROVED BY LIGHTING CONSULTANTS). Installation Charges including Skilled Labour, Suitable Size Cement Concrete and and Rent of T&P to Complete the job in All Respect.as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF PRECISION BEAM FLOOD LIGHT WITH ANTIGLARE VISOR (IP66) WITH FOLLOWING SPECIFICATIONS:750 LM (TOLERENCE IN LUMENS ±10%), 10° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), BLUE COLOR, OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. DIE CAST ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 . LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 750 LM AND POWER CONSUMPTION SHOULD NOT BE MORE THAN 40W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect. as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 4 Sq mm CU Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 16 sq. mm (28mm)
S/F of Gland for 3C X 4 sq mm CU Armoured Cable.
S/F of 4 sq mm CU Lug for CU Armoured Cable.
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 40 mm dia GI pipe Medium Class.
S/L of 25 mm dia. PVC HD Conduit pipe
S/L of 32 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) .
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 32A 4P MCCB (TM-R) (18 kA) - 1no., 32A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 7 Nos.
GEETA BHAWAN VASTRA VIBHAG + RELATED BUILDING (N)
SITC OF 500MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE)WITH FOLLOWING SPECIFICATIONS: 1500 LM (TOLERENCE IN LUMENS ± 10%), 10°X50° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED DRIVER SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 1500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 24W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 25 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 3 Nos.
FEEDER 1 (AIR PORT TO RISHIKESH ROAD) (O)
SITC OF LED STREET LIGHT FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 11000 LM (TOLERENCE IN LUMENS ± 10%), TYPE-II OPTICS, 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. CLASS HAVING SINGLE PIECE PRESSURE DIE-CAST ALUMINIUM HOUSING, CRI>70,THD<10%, P.F. >0.95, INBUILT SURGE PROTECTION OF 10 KV, LIFE CLASS OF 50,000 HRS. AT L70B50, THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 11000 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 110W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF 10 METER HIGH POLE, 150MM DIA, C-CLASS, MS POLE,WITH 2 FLAG, ANTHRACITE GREY PAINT, WITH PLANTER BASKET AND WITH PLATE MOUNTING ARRANGEMENT, PLATE SIZE- 600MM X 600MM X 20MM, SUITABLE FOR BRACKET LESS DIRECT LIGHTING FIXTURE INSTALLATION. AS PER DRAWING ATTACHED AND TERMINAL ARRANGEMENT. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 1.5 Sq mm FR Insulated Industrial flexible Copper Conductor Cable. Make-Havells.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 16 sq. mm (28 mm)
S/F of 16 sq mm AL Lug for AL Armoured Cable.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia GI pipe Medium Class.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Road Cutting Charges for Cable Crossing.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 32A 4P MCCB (TM-R) (18 kA) - 1no., 32A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A TPN MCB(10kA) - 2 Nos.
FEEDER 2 (AIR PORT TO RISHIKESH ROAD) (P)
SITC OF LED STREET LIGHT FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 11000 LM (TOLERENCE IN LUMENS ± 10%), TYPE-II OPTICS, 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. CLASS HAVING SINGLE PIECE PRESSURE DIE-CAST ALUMINIUM HOUSING, CRI>70,THD<10%, P.F. >0.95, INBUILT SURGE PROTECTION OF 10 KV, LIFE CLASS OF 50,000 HRS. AT L70B50, THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 11000 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 110W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF 10 METER HIGH POLE, 150MM DIA, C-CLASS, MS POLE,WITH 2 FLAG, ANTHRACITE GREY PAINT, WITH PLANTER BASKET AND WITH PLATE MOUNTING ARRANGEMENT, PLATE SIZE- 600MM X 600MM X 20MM, SUITABLE FOR BRACKET LESS DIRECT LIGHTING FIXTURE INSTALLATION. AS PER DRAWING ATTACHED AND TERMINAL ARRANGEMENT. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 25 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 1.5 Sq mm FR Insulated Industrial flexible Copper Conductor Cable. Make-Havells.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 25 sq. mm (28 mm)
S/F of 25 sq mm AL Lug for AL Armoured Cable.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia GI pipe Medium Class.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Road Cutting Charges for Cable Crossing.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel,IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 100 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 63A 4P MCCB (TM-R) (18 kA) - 1no., 60A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 63/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 32A TPN MCB(10kA) - 3 Nos.
FEEDER 3 (AIR PORT TO RISHIKESH ROAD) (Q)
SITC OF LED STREET LIGHT FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 11000 LM (TOLERENCE IN LUMENS ± 10%), TYPE-II OPTICS, 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. CLASS HAVING SINGLE PIECE PRESSURE DIE-CAST ALUMINIUM HOUSING, CRI>70,THD<10%, P.F. >0.95, INBUILT SURGE PROTECTION OF 10 KV, LIFE CLASS OF 50,000 HRS. AT L70B50, THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 11000 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 110W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF 10 METER HIGH POLE, 150MM DIA, C-CLASS, MS POLE,WITH 2 FLAG, ANTHRACITE GREY PAINT, WITH PLANTER BASKET AND WITH PLATE MOUNTING ARRANGEMENT, PLATE SIZE- 600MM X 600MM X 20MM, SUITABLE FOR BRACKET LESS DIRECT LIGHTING FIXTURE INSTALLATION. AS PER DRAWING ATTACHED AND TERMINAL ARRANGEMENT. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 25 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 1.5 Sq mm FR Insulated Industrial flexible Copper Conductor Cable. Make-Havells.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 25 sq. mm (28 mm)
S/F of 25 sq mm AL Lug for AL Armoured Cable.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia GI pipe Medium Class.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Road Cutting Charges for Cable Crossing.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 100 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 63A 4P MCCB (TM-R) (18 kA) - 1no., 60A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 63/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 32A TPN MCB(10kA) - 3 Nos.
FEEDER 4 (AIR PORT TO RISHIKESH ROAD) (R)
SITC OF LED STREET LIGHT FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 11000 LM (TOLERENCE IN LUMENS ± 10%), TYPE-II OPTICS, 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. CLASS HAVING SINGLE PIECE PRESSURE DIE-CAST ALUMINIUM HOUSING, CRI>70,THD<10%, P.F. >0.95, INBUILT SURGE PROTECTION OF 10 KV, LIFE CLASS OF 50,000 HRS. AT L70B50, THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 11000 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 110W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF 10 METER HIGH POLE, 150MM DIA, C-CLASS, MS POLE,WITH 2 FLAG, ANTHRACITE GREY PAINT, WITH PLANTER BASKET AND WITH PLATE MOUNTING ARRANGEMENT, PLATE SIZE- 600MM X 600MM X 20MM, SUITABLE FOR BRACKET LESS DIRECT LIGHTING FIXTURE INSTALLATION. AS PER DRAWING ATTACHED AND TERMINAL ARRANGEMENT. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 25 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 1.5 Sq mm FR Insulated Industrial flexible Copper Conductor Cable. Make-Havells.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 25 sq. mm (28 mm)
S/F of 25 sq mm AL Lug for AL Armoured Cable.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia GI pipe Medium Class.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Road Cutting Charges for Cable Crossing.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 100 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 63A 4P MCCB (TM-R) (18 kA) - 1no., 60A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 63/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 32A TPN MCB(10kA) - 3 Nos.
FEEDER 5 (AIR PORT TO RISHIKESH ROAD) (S)
SITC OF LED STREET LIGHT FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 11000 LM (TOLERENCE IN LUMENS ± 10%), TYPE-II OPTICS, 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. CLASS HAVING SINGLE PIECE PRESSURE DIE-CAST ALUMINIUM HOUSING, CRI>70,THD<10%, P.F. >0.95, INBUILT SURGE PROTECTION OF 10 KV, LIFE CLASS OF 50,000 HRS. AT L70B50, THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 11000 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 110W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE .Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF 10 METER HIGH POLE, 150MM DIA, C-CLASS, MS POLE,WITH 2 FLAG, ANTHRACITE GREY PAINT, WITH PLANTER BASKET AND WITH PLATE MOUNTING ARRANGEMENT, PLATE SIZE- 600MM X 600MM X 20MM, SUITABLE FOR BRACKET LESS DIRECT LIGHTING FIXTURE INSTALLATION. AS PER DRAWING ATTACHED AND TERMINAL ARRANGEMENT. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 4C X 25 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 1.5 Sq mm FR Insulated Industrial flexible Copper Conductor Cable. Make-Havells.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 25 sq. mm (28 mm)
S/F of 25 sq mm AL Lug for AL Armoured Cable.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia GI pipe Medium Class.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Road Cutting Charges for Cable Crossing.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Three Phase, 415V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Three phase and neutral busbars rated at 100 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type 1+2 Class (B+C) Surge protection device and having following: Incomer: 63A 4P MCCB (TM-R) (18 kA) - 1no., 60A 3P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 63/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 32A TPN MCB(10kA) - 3 Nos.
FEEDER 6 (AIR PORT TO RISHIKESH ROAD) (T)
SITC OF LED STREET LIGHT FIXTURE (IP66) WITH FOLLOWING SPECIFICATIONS: 11000 LM (TOLERENCE IN LUMENS ± 10%), TYPE-II OPTICS, 4000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 230VAC MAINS WITH OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. CLASS HAVING SINGLE PIECE PRESSURE DIE-CAST ALUMINIUM HOUSING, CRI>70,THD<10%, P.F. >0.95, INBUILT SURGE PROTECTION OF 10 KV, LIFE CLASS OF 50,000 HRS. AT L70B50, THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 11000 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 110W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF 10 METER HIGH POLE, 150MM DIA, C-CLASS, MS POLE,WITH 2 FLAG, ANTHRACITE GREY PAINT, WITH PLANTER BASKET AND WITH PLATE MOUNTING ARRANGEMENT, PLATE SIZE- 600MM X 600MM X 20MM, SUITABLE FOR BRACKET LESS DIRECT LIGHTING FIXTURE INSTALLATION. AS PER DRAWING ATTACHED AND TERMINAL ARRANGEMENT. Installation Charges including Skilled Labour , Suitable Size Cement Concrete and Rent of T&P to Complete the job in All Respect .
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 16 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 1.5 Sq mm FR Insulated Industrial flexible Copper Conductor Cable. Make-Havells.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2C X 16 sq. mm (22mm)
S/F of 16 sq mm AL Lug for AL Armoured Cable.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S/L of 40 mm dia. HDPE pipe SDR 11 ISI
S/L of 50 mm dia GI pipe Medium Class.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Road Cutting Charges for Cable Crossing.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 2 Nos.
(HANUMAN TEMPLE) (U)
SITC OF SURFACE MOUNTED 1000MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 800 LM (TOLERENCE IN LUMENS ± 10%), 10 X50° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 800 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE . Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF WALL MOUNTED ROUND DOWN LIGHTER FIXTURE (IP66) SECTION SIZE- DIAMETER - 100MM, HEIGHT - 100MM WITH FOLLOWING SPECIFICATIONS: 400 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ±10%), 3000K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE. & HARDWARE. Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC OF OUTDOOR LED STRIP FITTED IN ALUMINUM PROFILE SECTION SIZE- 16MM X 16MM (IP66) , LUMENS OUTPUT- 700 LM/METER (TOLERENCE IN LUMENS ± 10%), LED OPEN OPTICS, 2700K CCT (TOLERENCE IN CCT ±150K), , OPERATING ON 24VDC MAINS WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING . LUMINAIRE SHOULD BE IP66 & IK06 & LED POWER SUPPLY SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 700 LM/METER AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 10W/METER. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect . as per Technical Specification.
SITC OF 300MM LONG LINEAR LIGHT (IP66) MOUNTING ON CONCRETE SURFACE( THERE SHOULD BE NO GAP B/W THE FIXTURE AND THE CONCRETE SURFACE) WITH FOLLOWING SPECIFICATIONS: 500 LM (TOLERENCE IN LUMENS ± 10%), 30° OPTICS (TOLERENCE IN BEAM ANGLE ± 10%), 3000K CCT ( TOLERENCE ±150K), OPERATING ON 24VDC MAINS WITH WITH REMOTE LED DRIVER OPERATING VOLTAGE RANGE BETWEEN 100VAC TO 270VAC. LED FROM CREE/NICHIA/LUMILED/OSRAM. POWER SUPPLY SHOULD BE NON INTERGRAL PART OF THE LUMINAIRE AND SHOULD HAVE >85% EFFICIENCY WITH POWER FACTOR OF >0.90. EXTRUDED ALUMUNIUM HOUSING & CLEAR GLASS COVER HOUSING. LUMINAIRE SHOULD BE IP66 & IK06 & LED DRIVER SHOULD BE IP65. LUMINAIRE SHOULD BE WITH BIS CERTIFIED. LUMEM MAINTENANCE OF 70% AT 50000 BURNING HOURS AT 35 DEG C. FIXTURE SHOULD HAVE CONSTANT LOCKING HINGES FOR SIMPLE POSITION CONTROL FROM VARIOUS ANGLES WITHOUT SPECIAL TOOLS. THE DELIVERED LUMEN OUTPUT OF THE PRODUCT WITH NATIVE LENS SHOULD BE NOT LESS THAN 500 LM AND THE POWER CONSUMPTION SHOULD NOT BE MORE THAN 8W. PHOTOMETRIC DATA SHALL BE PASSED ON TEST RESULTS FROM AN INDEPENDENT TESTING LAB. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL DELIVER COMMON AND REPEATABLE COLOR PAINT TO MAINTAIN COLOR CONSISTENCY FROM FIXTURE TO FIXTURE OVER TIME, WHILE ENSURING A RELIABLE SUPPLY OF LEDS FROM THE SUPPLIER. THE LUMINAIRE MANUFACTURER SHALL PROVIDE CORROSION PROOF-PAINTS FOR THE SAME. LUMINAIRES INCLUDES ANTI GLARE ACCESSORIES SNOOT (SHOULD BE OF THE SAME COLOR AS OF LUMINAIRE), MOUNTING ARRANGMENT AND OTHER REQUIRED ATTACHEMENTS & HARDWARE & HARDWARE.Installation Charges including Skilled Labour and Rent of T&P to Complete the job in All Respect .as per Technical Specification.
SITC of UL Listed maintenance free, low carbon, Copper coated earth rod of 1.5 meter electrode having dia meter of 14.2 mm with opper coating thickness of 250 micron tested as per IEC 62561-2+ Universal Clamp (SS), 14mm +earth Continuity enhancing mineral compound shall be of 25 Kg/Pit tested as per IEC 62561-7, TCLP tested OEC 2 25 + the above arrangment shall be provided with Heavy duty earth chamber of 5000 Kg load bearing capacity to ensure the safety of earthing system under floor eath inspection pit. Rent of T&P to Complete the job in All Respect .
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
S/L of 2C X 10 Sq mm AL Armoured Cable Complete in all Respect.
S/L of 3C X 2.5 Sq mm CU Armoured Cable Complete in all Respect.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19 mm)
S/F of Gland for 3C X 2.5 sq mm CU Armoured Cable.
S/F of 2.5 sq mm CU Lug for CU Armoured Cable.
S/L of 32 mm dia. HDPE pipe SDR 11 ISI
S/L of 25 mm dia. PVC HD Conduit pipe
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.
The Design, manufacture, Supply, Installation, Testing & Commissioning of following Lighting Panel: Single Phase, 240V Lighting panel, IP 65 Out door type with canopy, Including standing Arrangement ,double door with lockable arrangement made from 2 mm thick CRCA sheet steel,The panel shall be given one coat of red oxide primer and two coats of enamel paints. powder coated with off white colour (inside & outside),1no.earth stud on each side face, Phase indicating lamps RYB with 2 Amps SP C Series MCB back up. Electrolytic high conductivity Aluminium Single phase and neutral busbars rated at 63 amps, 18KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. 40KA Type II (P+N) Surge protection device and having following: Incomer: 32A 2P MCCB (TM-R) (25 kA) - 1no., 32A 2P contactor -1no.Rotary Handle,RYB Indication Lamp, Spreader Terminal, Astro Time Switch having following facilities:Precise time programming for-Daily/Weekly,Pulse switching,Simple Reset feature,Week end programming, 24 Hr display (Military), Manual Over ride. Supply Voltage & Frequency:110-240VAC,+10%/-20%,50/ 60 Hz; Memory Locations: 8 On / Off operations, 16 memory locations; Minimum Switching Time: 1 min; Housing: Flame Retardant UL94V0. Digital VAF Meter with 32/5A CT CL-1 for metering, CT Short Link, Add on Block as required.On Indication Lamp Green LED for relay ON ,Off Indication Lamp Red LED for relay Trip, Auto and Manual Switch. High and Low Voltage Cut OFF. Outgoing: 20A DP MCB(10kA) - 3 Nos.
Supply and fixing of 32A 415V 4P Bus-Bar Chamber including Connection.