Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | ₹22.5 L Quoted ₹23.9 L | L1 | Accepted-AOC Accepted for acceptance being lowest. |
| 2 | L2₹27.4 L+₹3.4 L (14.4%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹27.4 L+₹3.4 L (14.4%) | L2 | Rejected-Finance Not L1. |
| 3 | L3₹30.1 L+₹6.2 L (25.8%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹30.1 L+₹6.2 L (25.8%) | L3 | Rejected-Finance Not L1. |
| 4 | L4₹30.5 L+₹6.6 L (27.5%)Rejected-Finance | ₹30.5 L+₹6.6 L (27.5%) | L4 | Rejected-Finance Not L1. |
| 5 | Rejected-Technical HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | - | - | Rejected-Technical Rejected for F bid opening. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Oct 2024, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF WATER SUPPLY LINES, UNSERVICABLE CONTROL PANEL, UNDERGROUND CABLES, VOLTAGE STABILIZERS, CSS, LT PANELS AND OTHER MISC E/M WORKS AT VARIOUS LOCATIONS AT AF-II UNDER GE (AF) JAMNAGAR NO.2
2024_MES_670709_1
8528/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹60,000
Yes
26 Oct 2024
3 Sept 2024
2 Oct 2024
3 Sept 2024
1 Oct 2024
17 Sept 2024
Amount
Excavation in trenches in hard / dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth for laying cables in trenches / pole foundation and getting out complete all as specified and directed.
Material & labour for sand cushioning to UG cable 40mm wide 15cm and 8cm thick above and below the cable respectively excluding for protection of PCC cable cover on the top of the sand cushioning complete all as specified and directed. Note : Punned thickness of sand will be measured & paid.
Taking down old unservicable reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.
Laying only PCC cable cover for LT / HT UG cable, of any description retrieved from taking down cable covers complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm thick complete all as specified and directed.
Supply & Fixing GI tubing light grade 80 mm bore for cable protection fixed to poles under floor/ground with all fittings complete all as specified and directed.
Supply & Fixing GI tubing light grade 50 mm bore for cable protection fixed to poles under floor/ground with all fittings complete all as specified and directed.
Taking out old unservicable LT cable any size from trenches / duct and removing from site complete all as specified and directed.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistarnded aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed confirming to IS-7098,1998 (part-I) specification complete all as specified and directed for following sizes:- Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 3.5 Core
25 Sqmm 3.5 Core
Material & labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of electric poles, struts, blocks with and including necessary form work, and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
M&L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
All as per item No.13 above but using galvanised earth lead wire 4.0mm dia as earthing lead
Taking out old/unsv rusted LT Panel of any size and description, disconnecting cable connection, demolition of existing concrete complete all as specified and directed.
Supply, installation, testing and commissioning LT panel outdoor type confirming to IS 8623 Part-I (one) obtained from CPRI approved manufacturer, totally enclosed weather and vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made out of 2.0mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 60x60x6mm, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs,legs grouted in PCC 1:2:4 type 'B-1' and making good disturbed surface complete and comprising of the following :-
A. (i)TPN Aluminium electrolytic grade bus bar of capacity 400 Amps for phases & 250Amps for neutral. and auxillary busbar to support main busbar.duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve.(ii) Digital multifunction meter (V, A, KW, KWH), 415V AC alongwith C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. CTs 500/5A class 1.0,15VA(Cast Resin) for metering-03 nos .(iv) Internal wiring, with suitable size of FRLS copper conductor cable. B. INCOMER:(i)MCCB 250 Amp 4 pole,35 KA confirming to IS/IEC 60947-2,Ics=100% Icu with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator - 01no
C.OUTGOING : (i) MCCB 100 amp 4 pole, 25 KA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase seperator - 01nos (ii) MCCB 63 amp 4 pole, 25 KA, Ics=100% Icuwith fixed magneticand adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase seperator - 05 nos complete all as specified and directed. Note:(i) LT Panel shall be brought from CPRI approved manufacturer. (ii) Contractor shall submit the following Test report. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel. (iii) Contractor shall submit drawing for approval prior to place order.
Supply, installation, testing and commissioning LT panel outdoor type confirming to IS 8623 Part-I (one), obtained from CPRI approved manufacturer, totally enclosed weather and vermin proof suitably ventilated for 3 phase , 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame , factory fabricated , compartmentalized inner shell shall be made of out of 2.0mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 60x60x6mm , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs,legs grouted in PCC 1:2:4 type B-1 and making good disturbed surface complete and comprising of the following :-
A. (i)TPN Aluminium electrolytic grade bus bar of capacity 350 Amps for phases & 200 Amps for neutral. and auxillary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V, A, KW, KWH), 415V AC alongwith C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. CTs 500/5A class 1.0,15VA(Cast Resin) for metering-03 nos .(iv) Internal wiring, with suitable size of FRLS copper conductor cable. B. INCOMER: (i)MCCB 200 Amp 4 pole,35 KA confirming to IS/IEC 60947-2,Ics=100% Icu with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10ln setting complete with phase seperator - 01no
C.OUTGOING : (i) MCCB 100 amp 4 pole, 25 KA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10 ln setting complete with phase seperator - 01nos (ii) MCCB 63 amp 4 pole, 25 KA, Ics=100% Icu with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10ln setting complete with phase seperator -01 nos (iii) MCB TPN 63 amp,10KA, C Curve -03 nos complete all as specified and directed. Note:(i) LT Panel shall be brought from CPRI approved Manufacturer. (ii) Contractor shall submit the following test report. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel. (iii) Contractor shall submit drawing for approval prior to place order.
Supply, installation, testing and commissioning LT panel outdoor type for Location : Near Sabarmati Guest Room and Bldg no P-20 confirming to IS 8623 Part I(one) ,obtained from CPRI approved manufacturer, totally enclosed weather and vermin proof suitably ventilated for 3 phase , 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame , factory fabricated , compartmentalized inner shell shall be made of out of 2mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 60x60x6mm , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs,legs grouted in PCC 1:2:4 type 'B-1' and making good disturbed surface complete and comprising of the following :-
A. (i)TPN Aluminium electrolytic grade bus bar of capacity 350 Amps for phases & 200 Amps for neutral.and auxillary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V, A, KW, KWH), 415V AC alongwith C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. CTs 500/5A class 1.0,15VA (Cast Resin) for metering-03 nos. (iv) Internal wiring, with suitable size of FRLS copper conductor cable. B. INCOMER:(i) MCCB 200 Amp 4 pole, 35 KA, Ics=100% Icu Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10 ln setting complete with phase seperator - 01 No
C.OUTGOING : (i) MCCB 63 amp 4 pole, 25 KA, Ics=100% Icu Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100%and adjustable short circuit 5 to 10ln setting complete with phase seperator - 03 nos (ii) MCCB 100 amp 4 pole, 25 KA, Ics=100% Icu Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10 ln setting complete with phase seperator - 1 nos. Note: (i) LT Panel shall be brought from CPRI approved manufacturer (ii) Contractor shall submit the following test report i.e. IP test report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel. (iii) Contractor shall submit drawing for approval prior to place order.
M & L for preparation of old painted surfaces of RCC/PCC pole and painting to pole 9.0m long with application of two coats of cement base paint of approved colour, air force blue colour, marking of strip in alternate blue and white paint pattern up to 2.0mtr above the pole coping and marking of pole number in yellow background circle 10cm radius and writing pole no, 3cm long using black colour complete all as specified and directed.
M & L for preparation of old painted surfaces of steel tubular pole and painting to pole 9.0m long with application of two coats of synthetic enamelled silver paint of approved colour , marking of strip in alternate black and white paint pattern up to 2.0mtr above the pole coping and marking of pole number in yellow background circle 10cm radius and writing pole no , 3cm long using black colour complete all as specified and directed.
Supply and fix CI cable route indicator 100mm dia , 5mm thick duly engraved with " LT 1100 volts" having CI rod 10mm dia, 50 to 70 cm long, duly welded to round plate with PCC 1:4:8 type D2 complete all as specified and directed.
Material and labour for synthetic insulating mat of size 2m x 1m x 19mm thick complete as per ISI marked and it is should be approved by CPRI and as per IS-8437 for test complete all as specified and directed.
S & F Exide XP1500 battery 12V, 150-180Ah heavy duty batteries are made using special hybrid alloy used for DG set confirming to IS 16270 and IS 16046 complete with initial charging suitable for DG set complete all as specified and directed.
S & F in repairs 4 pole contactor 125A 4NO , suitable for 415V AC complete all as specified and directed. Make: ABB cat part No.1SBL41120R or equivalent makes as mentioned in Appx 'B' to PS.
S & F in repairs MCCB 200/250 Amp 4 pole, 36 KA confirmin g to IS/IEC 60947-2, Ics=100% Icu with fixed magnetic and adjustable thermal release, adjustable overload 80-100%and adjustable short circuit 5 to 10 ln setting complete with phase seperator, suitable for 415V AC complete all as specified and directed. Make: ABB cat part no.1SBL41120R or equivalent make as mentioned in Appx 'B' to PS.
M & L for shifting of solar light street pole/ street light pole to a distance not exceeding 50 mtr and erect in true vertical position steel tabular pole, around 15.0 metres long complete all as specified and directed. Work consisting of including following:- Note: (i) PCC foundation & coping, Excavation earth work. (ii) nut bolt like as existing as required. (iii) hydro crane for shifting the pole.
Supply and fixing / aluminium service wire, 2.5sqmm 1100 volts grade heavy duty cable with PVC insulated multi stranded copper conductor cable flame retardant low smoke & halogen 1100volt confirming to IS complete all as specified and directed.
S & F in repairs MCCB 400 Amp 4 pole, 36 KA confirmin g to IS/IEC 60947-2, Ics=100% Icu with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short circuit 5 to 10 ln setting complete with phase seperator, suitable for 415V AC complete all as specified and directed. Make: ABB cat part no.1SBL41120R or equivalent make as mentioned in Appx 'B' to PS.
Supply and fix in repair outdoor waterproof metal type pillar light/dome light/gate light modern design type suitable for Primary:220-240 V AC , 50/60Hz for outdoor purpose having already fitted LED fitting inbuit driver 60 watt suitable for home enterance, home gate including taking out old/unsv complete all as specified and directed.
Supply and fix in repair outdoor AVIATION red obstruction warning light having day/night photocell sensor, flashing 20-60 FPM suitable for Primary:220-240 V AC , 50/60Hz having IP 65 rating as per standard IS/IEC 60529:2001 with polycarbonate glass for 360 degree illumination having photocell on/off internally fitted including taking out old/unsv complete all as specified and directed.
M&L for repairing / servicing the centrifugal pump set up to 25 HP type DSM 80 / 36, by disconnecting the pump from motor, opening for inspection, replacing the worn out parts:- (i) pump shaft 01 No, (ii) replacement only impellers 01 No, (iii) gland bush 01 No, (iv) gland bearings 01 No (v) Non driven end bearing 01 no (vi) gland packing 01 No, (vii) gasket 01 No, (viii) water seal 01 No including repairs to pump shaft by remetaling, grinding, polishing, reassembling the same and replacing the rusted nuts, bolts washers etc, reconnecting with motor and testing complete all as specified and directed.
M&L for repairing / servicing the monoblock pump set of capacity upto 15HP by dismantling the pump and motor, over hauling the pump by replacing the complete worn out parts:- (i) Cast iron impeller 01 -No (ii) bearing 02 Nos, (iii) water seal -01 No, repairing the shaft by remetaling / welding, grinding, polishing etc, repairing / servicing the electric motor by replacing the worn out bearing driven and non driven ends, reassembling the pump and motor including testing complete all as specified and directed.
Taking out & rewinding the existing unserviceable burnt motor upto 25HP, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and directed. Note - Before rewinding the existing motor, contractor must show the burnt motor / winding to the EIC. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of old U/s copper winding and u/s spares.
S&F in repairs flat 3 core copper conductor PVC insulated and PVC sheathed cable 1100 volts grade of size 6 Sqmm fixed to wall/ in duct, laid in floor/trench or fixed to motor complete all as specified and directed.
S&F in repair ball valve of size 20 mm CPVC type outer diameter including nut bolt washer & rubber packing complete all as specified and directed.
S&F in repair ball valve of size 25 mm CPVC type outer diameter including nut bolt washer & rubber packing complete all as specified and directed.
Supply only HDPE pipe of outer dia 100 mm confirming to IS - 4984, ISI marked, working pressure 10 kg / sqcm including jointing material, clamps and nut bolts washers etc complete all as specified and directed.
Supply only gland packing 10 / 12 mm size, complete all as specified and directed.
Supply only water proof grease of best quality complete all as specified and directed.
M & L for preparation of old painted exposed surface of old pipe line, pumps, motors, headers etc including 80-250 mm bore suction & delivery line existing metre as per site by removing dust, dirt, and painting with two coats of synthetic enamel paint of existing colour by using the air pressure spray gun machine, writing marked in suction / delivery line to pump sets with white paint complete all as specified and directed.
S&F in repair cast iron foot valve of size 150 mm flanged type including nut bolt washer & rubber packing complete all as specified and directed.
S&F in repair cast iron foot valve of size 80/100 mm flanged type including nut bolt washer & rubber packing complete all as specified and directed.
Supply & fix in repair, dual plate non return valve of size 150 mm with cast iron body, SS-304 / 316 springs, duly insulated, flanged type, including nut bolt washer & rubber packing & testing and commission complete all as specified and directed.
Supply & fix in repair, dual plate non return valve of size 100 mm with cast iron body, SS-304 / 316 springs, duly insulated, flanged type, including nut bolt washer & rubber packing & testing and commission complete all as specified and directed.
Supply & fix in repair, dual plate non return valve of size 80 mm with cast iron body, SS-304 / 316 springs, duly insulated, flanged type, including nut bolt washer & rubber packing & testing and commission complete all as specified and directed.
Supply and fix in repair single phase electric driven motor, 230 volt, 50 Hz, 120 Watts, 920 RPM suitable for Altoch dosing plant, including fitting and testing complete all as specified and directed.
S&F in repairs 15 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation / earth work will be measured and paid separately.
S&F in repairs 20 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation / earth work will be measured and paid separately.
S&F in repairs 25 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation / earth work will be measured and paid separately.
Taking up or down 15 mm bore steel tubing and connected fitting from wall, ceiling floor etc complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connected fitting from wall, ceiling floor etc complete all as specified and directed.
Taking up or down 25 mm bore steel tubing and connected fitting from wall, ceiling floor etc complete all as specified and directed.
Taking up or down 40 mm bore steel tubing and connected fitting from wall, ceiling floor etc complete all as specified and directed.
Taking up or down 80 mm bore steel tubing and connected fitting from wall, ceiling floor etc complete all as specified and directed.
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor, complete all as specified and directed.
Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor, complete all as specified and directed.
Supply and fix 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor, complete all as specified and directed.
Supply and fixed on wall / laid in trenches 40/50 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line complete all as specified and directed.
Supply and fixed on wall / laid in trenches 80 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc and connecting to water supply pipe line complete all as specified and directed.
Supply & fix in repair, laying, jointing and testing in trenches 100/150 mm dia ductile iron pipes, socket and spigot end suitable for push-on-joint (rubber gasket jointing), ISI marked, centrifugally cast (spun), conforming to IS:8329, classification, K-7 rating, with cement mortar lining inside the pipes and outside zinc coating with bituminous finish coat including jointing complete all as specified and directed. Note:- Earth work, DI fittings, Joint and Jointing materials shall be measured & paid for separately.
S&F DI fitting for DI spigot and socketed / flanged ends pipes like bends (any type, radius and angle) increasing, decreasing or double socketed / flanged tee pieces single branch 'Y' junction double branch, cross collars caps and plugs, connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth suitable for up to 300 mm bore pipe complete all as specified and directed. Note :- (i) The weight of the fitting for the purpose of payment shall be actual weight of the fitting or as specified in IS code which ever is less. (ii) Jointing materials such as run lead joint, rubber tyton joint shall be measured & paid for separately.
S&F in repairs gun-metal, brass globe gate valves or ball valve of size 15 mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs gun-metal, brass globe or gate valves of size 20mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of size 25mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of size 40mm dia with iron wheel head, screwed both ends or threads for iron pipe fixed and complete all as specified and directed.
Supply and fix 100 mm size cast iron butterfly valve, with both end flanged type, conforming to IS 13095 with nuts bolts and washers of suitable size and necessary rubber gaskets etc complete all as specified and directed.
Supply and fix 150 mm size cast iron butterfly valve, with both end flanged type, conforming to IS 13095 with nuts bolts and washers of suitable size and necessary rubber gaskets etc complete all as specified and directed.
Supply and fix 80 mm size sluice valve, long body type of pressure rating PN-1.0 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete all as specified and directed.
Supply and fix 100 mm size sluice valve, long body type of pressure rating PN-1.0 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete all as specified and directed.
Supply and fix 150 mm size sluice valve, long body type of pressure rating PN-1.0 with stainless steel spindle, both end flanged, ISI marked complete with cast iron wheel, nut, bolt, washer, rubber packing etc., confirming to IS-14846-2000 complete all as specified and directed.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate, as in sub base over the existing path surface complete all as specified and directed.
Surface cleaning / dressing by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds in soft loose soil at surrounding area of various E/M installations complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide but not exceeding 1.5 m in depth for foundation etc or for shafts and getting out in soft/losse soil including trimming sides and bottom of trenches complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed.
Deployment plumber with tools and ladder for attending "No Water Supply" / No Electric Supply Complaints at AF-1 & AF-2 Area and clear minor defects/blockaged pipe line at top of the accomodation water storage tanks, wall / under ground complete all as specified and directed. Note: Quoted rates shall be inclusive of minor repair items including material like elbow, tee, nipples, union etc as per site requirement.
M & L for repairing of crack in 80 / 100 / 150mm bore DI / CI / GI / MS water pipe line by providing mild steel two piece half round clamp fabricated with 60 mm wide & 5 mm thick mild steel flat bend to shape welding 25 mm size socket, including nut bolt, rubber packing, drilling hole in existing pipe line & painting of clamp with anti corrosive paint complete all as specified and directed.
BHAVNA IMPERIAL ENTERPRISE (BID ID -3111434)
SURESH ELECTRICALS (BID ID -3111831)
Sukhi Electricals (BID ID -3100145)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .