Loading…
Loading…
Tender Value
₹13.1 L
EMD Value
₹26,216
Closing Date
17 Jul 2026, 11:00 am2d left
Executive Engineer (E)
EE(E), PWD EMD (M-251) Ramesh Park Delhi
Maintenance and Operation of street light and High Mast light i/c monitoring of street light, lift and escalators at various locations under PWD M-251. Delhi. (SH- SITC of decorative post top light at various location under sub division-3/M2533)
2026_PWD_295219_1
46/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
30 days
M-2533
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹26,216
Yes
10 Jul 2026
10 Jul 2026
17 Jul 2026
10 Jul 2026
17 Jul 2026
10 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of Decorative pole of 3Mtr height. The pole shall be made out of Mild steel tube, Bottom dia min.139mm X 1000mm (L), Top Dia min. 76mm X 2000mm(L) & MS Base Plate 250X250X10mm. The different section of tubes are jointed together. The Middle embellishment are of Cast Aluminum & top ring are cast alusminum fixed to the pole by grub/Knurled/cone/rivet screw. The pole shall be provided integral service connection box & heavy arrangement of One No SPMCB & 32-amp heavy duty in the pole & cover the same complete etc. as reqd. (Note:- The work shall be executed only after obtaining prior approval of Design of Pole from the Engineer-in-Charge) | |||||
| 2SITC of decorative 40Watt LED light fully weather proof, Post-Top / Pole light fitting made out of pressure die cast aluminum housing with opal/clear acrylic protection duly silicon filled, U.V. Resident, Power coated paint, with highly efficient electronic external driver having efficiency >85%, THD<10%, Power Factor >0.95, IP-66, CRI >70, high voltage protection, power LED White/Warm White mounted on MCPCB with better heat dissipation arrangement duly wired up to connection etc. as reqd. (CCT & other Parmeter is decided by Engineer-in-Charge (Note:- The work shall be executed only after obtaining prior approval of Design of Light from the Engineer-in-Charge.) | |||||
| 3Providing and laying in position M 15 (1:2:4) reinforced cement concrete foundation of size 400 mm (L) x 400 mm (W) and 500 mm (D) i/c excavation of earth, Filling of earth, centering & shuttering of formwork of foundation, Providing cutting, bending and placing in position, reinforcement cold twisted bars of 12 mm dia 600 mm long (approx.) -4 nos. and reinforcement ring of TMT bars of 8 mm dia-1200 mm (aprox.) - 3 nos. (with 150 mm spacing) as required with positioning of 4 Nos. 16 mm dia 450 mm long foundation anchor bolts, nuts, washer etc. and providing 63 mm (O.D) DWC/ HDPE pipe for cable entry and exit as required etc. complete as reqd. | |||||
| 4Supplying and laying of following PVC insulated and PVC sheathed /XPLE armoured Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL pipe as required. | |||||
| 4.1 | 3 X 10 Sq. mm armounrd Aluminum conductor power cable | - | Mtr | - | - |
| 4.2 | 4 X 25 Sq. mm armounrd Aluminum conductor power cable | - | Mtr | - | - |
| 5Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. | |||||
| 5.1 | 63 mm dia (OD-63 mm & ID-51 mm nominal) | - | Mtr | - | - |
| 6SITC of Outdoor type totally enclosed weather proof compartmentalized feeder pillar of sizes not less than (1.55 mtr. x 0.55 mtr) and depth not less than 300 mm, fabricated with 2 mm thick CRCA / MS sheet with base frame fabricated from 35 x mm x 35 mm x 5 mm thick MS angle iron suitable for 415/ 500 volts 50 Hz A.C. supply with MS sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, hinged front openable double leaf door with locking arrangement complete with bus bar chamber having 100 amp TPN Alu. bus bar and the MS cover, covering the MCCB's / MCB's and aluminium strips etc. as reqd. (only MCCB's knobs shall be visible) i/c supplying and fixing the following mounting inside the feeder pillar - interconnections with suitable size Al. bus bar / Copper wire for outgoing and incoming MCB's/ MCCB's/ connector, earthing studs, powder coating/ stove enameled painting after 7 tank treatment process, suitable size CC foundation i/c covering the panel by wiremesh with central lock etc. as reqd. (not less than 0.56) (a) Incoming 100 Amp 3 Pole 16 KA MCCB with handle rotary & spreader - 1 No. (b) Outgoing 1) 63 Amp 3 Pole 16 KA TPMCCB with handle rotary & spreader - 1No. 2). Digital Timer - 1 No. 3). 63 Amp 3 Pole Contactors - 1 No. | |||||
| 7Fabricating, Supplying and fixing wire mesh protection frame work made out of 40 mm x 6 mm thick angle and "T" strengthened with intermediate menberers of MS flat iron of size 32 mm x 6 mm thick welded at a distance of 30 cm horizontally and vertically and duly welded with wiremesh of size 75 mm x 25 mm made with 6 SWG wire mesh of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two nos. sliding bolts and one No. go down lock) having 0.5 mtr long legs of 40 mm x 40 mm x 6 mm thick angles iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate) upto suitable depth painting with on coast of red oxide & two coats of synthetic enamel paint of approval colour and shade etc. complete as reqd. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.13 MB
BOQ_392798.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid