| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.3 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹24.5 L+₹10,242 (0.42%)Rejected-Finance | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹25.8 L+₹1.4 L (5.73%)Rejected-Finance | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹26.0 L+₹1.6 L (6.54%)Rejected-Finance DOOR NO 10 38 21 A RAMNAGAR VISAKHAPATNAM 530 002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹27.2 L+₹2.8 L (11.6%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 5 | Rejected-Finance Not L-1 |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
2 Jan 2021, 6:00 pmClosed
Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF PAVER BLOCK PATH ALONG THE ROAD SIDE OF RESIDENTIAL AREA AT NAD PROVN OF 02 NOS PORCH IN BLDG NO P48 AND P201 AT NAD AND PROVN OF CEMENT CONCRETE PATHWAY AROUND DMTF AT INS VISHWAKARMA VISAKHAPATNAM
2020_MES_400814_1
8918
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
As per NIT
5 documents required · 5 mandatory
₹500
Yes
GE ND Visakhapatnam
₹58,000
Yes
19 Apr 2021
4 Dec 2020
7 Jan 2021
4 Dec 2020
2 Jan 2021
19 Dec 2020
Amount
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
All as per item No. 1 above but exc 1.5m and not exc 3.0m deep
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of plinth beams and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, columns and similar work for rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, lintels and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and directed.
M & L for TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for TMT bars 8mm dia, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for TMT bars 5mm dia and over upto 10mm dia as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia as in stirrups, spacers, binders complete all as specified and as directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in foundations, rafts, footings, plinth beams, basement slabs etc complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as directed.
M & L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces finished even and smooth with out using extra cement complete all as directed.
M & L for complete removal of existing treatment on walls and ceiling surfaces and applying two coats of weather proof (100% Acrylic emulsion) paint exterior grade over a coat of primer complete all as specified and directed.
M & L for brushing cleaned roof surfaces with neat cement slurry @3kg/ Sqm and applying 5mm thick cement screed in cement mortar 1:4 mixed with and including water proofing compound @ 2% by weight of cement, applying polymeric water proofing membrane of weight not less than 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non wwoven fabric (weight not less than 150 gms/Sqm) including coating the surface with water based bituminous primer @ 0.5 lit / Sqm and hot blown bitumen @ 1.20 Kg/Sqm at the bottom and another coat at top of the membrane and finally finished with one coat of bitumineous aluminium primer at 100 grams/Sqm complete all as specified and directed by the Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
Removing excavated material /soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
S & F Aluminium Composite Panel (ACP) 4mm thick of approved colour for interiors/exteriors in any position for any height consisting of two layers of aluminium skins of 0.25 mm thick sandwiching a thermo plastic core in continuous lamination process with PVDF coating for interior/exterior grades ensuring long colour and no fungal attacks including grid work made with aluminium square pipe of size 25mmx25mmx1.5mm thick and fixed to the panels with suitable fasteners without any undulations in facias complete all as per manufacturers instructions and as directed by the Engineer in-charge.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft / loose soil
Removing excavated material /soil to a distance exceeding 250m but not exc 500m and depositing where directed complete all as specified and directed
M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
M & L for 100mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in flooring / hard standings laid to slope in panels including finishing the surfaces even and fair complete all as specified and directed.
M & L for Machine pressed precast cement conctete coloured interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade over and including 50mm thick sand filling complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface using broken stone or boulders complete all as directed.
M & L for pre-polished coloured chequered cement concrete tiles of size 25cm x 25cm x 22 to 25mm thick with mixture of white & grey cement, set jointed and pointed with grey cement and no pigments in neat cement slurry as in floors and pointed with white cement laid over and including 15mm thick screed bed in CM 1:6 over 75mm thick PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) sub base complete all as specified and directed. [The design, colour and pattern of tiles shall be as approved by the GE]
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of modular terminal boxes and white cover plate with frame, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch complete all as specified and directed.
All as per item No. 30 above but point wiring with 2.5 Sqmm (nominal area) suitable for one power socket point on independent board complete all as specified and directed.
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular switch single pole, 1 way, 16 Amps, 1 module
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F MCB DB, SPN, 4 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connections and making good disturbed surfaces complete all as specified and directed.
S & F MCB, SPN, 40 Amps, 240 Volts
S & F MCB, SP, 5 to 32 Amps, 240 Volts
S & F Square ceiling recessed mounted LED light fittings (2'x2') of 3600 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 2 core 6 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls complete all as specified and directed.
S & F round recessed LED flat panel light of minimum 1200 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
M & L for cutting of road / hard standing for laying of cables and making good the disturbed portion in PCC 1:3:6, type C-1 using 20mm graded stone aggregate including removal of debris to a distance not exc 50m complete all as specified and directed.
Supply and laying GI pipe 40mm dia light grade including specials as required for cable protection fixed in any position complete all as directed
SUNIL KUMAR GIRI
M/s Sai Venkata Durga Constructions
M/s Saptagiri constructions
SAI KRISHNA ASSOCIATES
TECHNO SOFT SOLUTIONS
N V S S K N SIVA PRASAD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .