Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.6 L+₹2.2 L (4.96%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC L2 | |
| 3 | L3₹45.9 L+₹2.5 L (5.64%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L3 | Rejected-AOC L3 | |
| 4 | L4₹48.9 L+₹5.4 L (12.5%)Rejected-AOC FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | Glacier Cooling Solutions Private Limited L3 | Shree Ayyappa Engineering L1 | cooltech engineering services L2 | M/S SOMANATH ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00Supply, installation, testing and commissioning of Air cooled non Inverter ducted units of the undermentioned capacity, supply and charging of eco-friendly refrigerent R-410A, hard drawn copper refridgerent piping between indoor and out door units, control cabling between indoor & out door units, canvas flexible connections at indoor units, provide rigid PVC drain piping 25 mm dia up to nearest drain point, package AC should comprising of hermetically sealed scroll compressor, cooling coil internally grooved copper tubing with aluminium fins, fans, motor, safety devices, hydrophilic coated suitable to work till 50°C ambient temperature, with special blue condenser fiins constructed from galvanized powder coated sheets, with fire retardant EPE insulation for the evaporator coil, and consits of DIDW type centrifugal blowers with forward curved blades, including grouted on ribbed rubber pads as vibration insulators alongwith all standard fittings, HP/LP cutout, single phase preventer, OLR suitable for operational on three phase AC electric supply, including required foundation for base, MS frame stand for outdoor unit including fabrication work and installation work complete all as per OEM recommendation with making up good existing walls/floors/ceiling with existing finishes and electric switch breakers fixed on cable tray complete all as specified and directed. Note:- Items such as charging of gas, refrigerant piping, control cabling, draining piping used shall deemed to be measured and paid seperately under relevant items. | |||||||
| 1.01 | 11 TR ducted units | 1 | Each | 2,85,000 ₹2,85,000 | 2,53,700 ₹2,53,700 Lowest | 2,53,800 ₹2,53,800 | 2,68,400 ₹2,68,400 |
| 1.02 | 16.5 TR ducted units | 1 | Each | 4,22,500 ₹4,22,500 | 3,72,600 ₹3,72,600 Lowest | 3,72,900 ₹3,72,900 | 3,82,800 ₹3,82,800 |
| 1.03 | 22 TR ducted units | 4 | Each | 5,45,000 ₹21,80,000 | 4,98,200 ₹19,92,800 Lowest | 4,98,900 ₹19,95,600 | 4,98,500 ₹19,94,000 |
| 2.00 | Material and laying of refrigerant piping (suction & discharge) hard drawn from hard copper tube of suitable sizes as recommended by OEM, with copper elbows, tees all connecting material with insulation for indoor and outdoor unit connections complete all as specified and directed
Note: One run of both suction and discharge pipe line along with insulation shall be measured as one length. | 40 | RM | 2,850 ₹1,14,000 | 2,200 ₹88,000 Lowest | 2,500 ₹1,00,000 | 3,000 ₹1,20,000 |
| 3.00 | Suplly and fill of refrigerant 410A gas complete all as specified and directed | 120 | KG | 1,200 ₹1,44,000 | 1,100 ₹1,32,000 Lowest | 1,200 ₹1,44,000 | 2,500 ₹3,00,000 |
| 4.00 | Supply, Installation of control cabling between indoor unit and outdoor unit complete all as per OEM recommendation and directed | 50 | RM | 750 ₹37,500 | 700 ₹35,000 Lowest | 900 ₹45,000 | 1,500 ₹75,000 |
| 5.00 | Supply, assembly and erection of GI sheet of size 22 gauge (0.80mm) with TDF flange rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete all as specified and directed | 90 | SQM | 1,500 ₹1,35,000 | 1,100 ₹99,000 Lowest | 1,200 ₹1,08,000 | 2,000 ₹1,80,000 |
| 6.00 | Supply and installation of acoustic insulation having 10mm thickness at inside the duct with engineered Nitrile rubber open cell foam with density 150 - 180 Kg/m3 using manufacturer's recommended rubber based adhesive in a blend of solvents complete as per OEM recommendations and directed | 85 | SQM | 950 ₹80,750 | 930 ₹79,050 Lowest | 1,000 ₹85,000 | 1,500 ₹1,27,500 |
| 7.00 | Material and labour for superior quality of canvas connection complete all as specified and directed | 6 | Each | 3,500 ₹21,000 Lowest | 5,000 ₹30,000 | 6,000 ₹36,000 | 5,200 ₹31,200 |
Tender Value
Refer Docs
EMD Value
₹87,360
Closing Date
26 Jun 2026, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
PROVISION OF AIR CONDITIONING AT DINING HALL AND ANTE ROOM AT SNC(O) MESS, NAVAL BASE KOCHI
2026_MES_770022_1
8674/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹87,360
Yes
31 Jul 2026
5 Jun 2026
29 Jun 2026
5 Jun 2026
26 Jun 2026
20 Jun 2026
5 Jun 2026 - 6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commissioning of Air cooled non Inverter ducted units of the undermentioned capacity, supply and charging of eco-friendly refrigerent R-410A, hard drawn copper refridgerent piping between indoor and out door units, control cabling between indoor & out door units, canvas flexible connections at indoor units, provide rigid PVC drain piping 25 mm dia up to nearest drain point, package AC should comprising of hermetically sealed scroll compressor, cooling coil internally grooved copper tubing with aluminium fins, fans, motor, safety devices, hydrophilic coated suitable to work till 50°C ambient temperature, with special blue condenser fiins constructed from galvanized powder coated sheets, with fire retardant EPE insulation for the evaporator coil, and consits of DIDW type centrifugal blowers with forward curved blades, including grouted on ribbed rubber pads as vibration insulators alongwith all standard fittings, HP/LP cutout, single phase preventer, OLR suitable for operational on three phase AC electric supply, including required foundation for base, MS frame stand for outdoor unit including fabrication work and installation work complete all as per OEM recommendation with making up good existing walls/floors/ceiling with existing finishes and electric switch breakers fixed on cable tray complete all as specified and directed. Note:- Items such as charging of gas, refrigerant piping, control cabling, draining piping used shall deemed to be measured and paid seperately under relevant items. | |||||
| 1.01 | 11 TR ducted units | 1 | Each | - | - |
| 1.02 | 16.5 TR ducted units | 1 | Each | - | - |
| 1.03 | 22 TR ducted units | 4 | Each | - | - |
| 2 | Material and laying of refrigerant piping (suction & discharge) hard drawn from hard copper tube of suitable sizes as recommended by OEM, with copper elbows, tees all connecting material with insulation for indoor and outdoor unit connections complete all as specified and directed
Note: One run of both suction and discharge pipe line along with insulation shall be measured as one length. | 40 | RM | - | - |
| 3 | Suplly and fill of refrigerant 410A gas complete all as specified and directed | 120 | KG | - | - |
| 4 | Supply, Installation of control cabling between indoor unit and outdoor unit complete all as per OEM recommendation and directed | 50 | RM | - | - |
| 5 | Supply, assembly and erection of GI sheet of size 22 gauge (0.80mm) with TDF flange rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete all as specified and directed | 90 | SQM | - | - |
| 6 | Supply and installation of acoustic insulation having 10mm thickness at inside the duct with engineered Nitrile rubber open cell foam with density 150 - 180 Kg/m3 using manufacturer's recommended rubber based adhesive in a blend of solvents complete as per OEM recommendations and directed | 85 | SQM | - | - |
| 7 | Material and labour for superior quality of canvas connection complete all as specified and directed | 6 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
PS8674.pdf
Tender Documents • 0.54 MB
BOQ_862303.xls
BOQ • 4.93 MB
COMMONPAGES674.pdf
Tender Documents • 0.47 MB
8674_amenment.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .