| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.0 L−₹6,937.90 (0.86%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | SREEJITH S G L2 | K.Reghunathan L1 |
|---|---|---|---|---|---|
| 1.00Installation of 10KAV UPS | |||||
| 1.00 | OD90122/2026-2027:Supply Installation Testing and commissioning of 10KVA=10KW Unity output power factor modelMODEL 3 PHASE IN AND 3 PHASE OR 1 PHASE SELECTABLE OUT TOWER TYPE ONLINE DOUBLE CONVERSION PURE SINE WAVE UPS
SYSTEM WITH SALIENT FEATURES Like, maximum power availability Leading AC-AC efficiency up to 96% saves energy costs Low harmonic pollution (iTHD0.99) reduce upstream investment costs Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life DSP based technology enables reduction in the number of electronic components to lower failure rate Adjustablecharging current and battery voltage meet different battery configuration requirements, IGBT Rectire and inverter, Generater compatable,Noice level <58dB, can Parellel upto 4 systems.etc. (Delta /Numeric/Emerson )The supplier should be submitting Tested documents, Operation manual, service manual etc. EXTRNAL EXIDE C10 RATED TUBULAR BATTERY 12V, 75AH, 20 NUMBERS (MINIMUM VAH 18000) FOR 60 MINUTES BACKUP.. SUITABLE battery Rack with Battery breaker switch, Cables, Interlinks, all accessories with freight and Installation, Including three year service by service provider of OEM and its confimity certificate submitted at the time of installation | 1 | each | 5,35,000 ₹5,35,000 | 5,32,290 ₹5,32,290 Lowest |
| 2.00Electrification for the installation of UPS | |||||
| 2.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 10 | point | 1,720 ₹17,200 | 1,700 ₹17,000 Lowest |
| 2.00 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 60 | metre | 146 ₹8,760 | 140 ₹8,400 Lowest |
| 2.00 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 50 | metre | 165 ₹8,250 | 160 ₹8,000 Lowest |
| 2.00 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | 20 | metre | 210 ₹4,200 | 200 ₹4,000 Lowest |
| 2.00 | OD77342/2026-2027:SITC 1200 lumen round/ square(1X1) recessed fitting made of diecast aluminium body, polycarbonate diffuser, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea | 5 | each | 1,750 ₹8,750 | 1,742 ₹8,710 Lowest |
| 2.01 | OD77343/2026-2027:Supply and installation of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) | 8 | each | 5,100 ₹40,800 | 5,064 ₹40,512 Lowest |
| 2.01 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | 1 | each | 1,190 ₹1,190 | 1,180 ₹1,180 Lowest |
Tender Value
₹8.0 L
EMD Value
₹20,103
Closing Date
7 Aug 2026, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
GENERAL-Government Secretariat Thiuvananthapuram- Supply ,installation of 10KVA UPS and providing additional EI in Telephone Exchange in connection with the upgradation of exchange from EPABX system to IPPBX system-Electrical work-General Electrical
2026_PWD_863558_1
ESDT/ET-81/2026-27
Open Tender
Electrical Works
Item Rate
90 days
PWD Electrical Sub Division Tvpm
please refer tender documents
6 documents required · 6 mandatory
₹1,775
₹20,103
25 Sept 2026
31 Jul 2026
10 Aug 2026
31 Jul 2026
7 Aug 2026
31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Installation of 10KAV UPS | |||||
| 1.001 | OD90122/2026-2027:Supply Installation Testing and commissioning of 10KVA=10KW Unity output power factor modelMODEL 3 PHASE IN AND 3 PHASE OR 1 PHASE SELECTABLE OUT TOWER TYPE ONLINE DOUBLE CONVERSION PURE SINE WAVE UPS
SYSTEM WITH SALIENT FEATURES Like, maximum power availability Leading AC-AC efficiency up to 96% saves energy costs Low harmonic pollution (iTHD0.99) reduce upstream investment costs Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life DSP based technology enables reduction in the number of electronic components to lower failure rate Adjustablecharging current and battery voltage meet different battery configuration requirements, IGBT Rectire and inverter, Generater compatable,Noice level <58dB, can Parellel upto 4 systems.etc. (Delta /Numeric/Emerson )The supplier should be submitting Tested documents, Operation manual, service manual etc. EXTRNAL EXIDE C10 RATED TUBULAR BATTERY 12V, 75AH, 20 NUMBERS (MINIMUM VAH 18000) FOR 60 MINUTES BACKUP.. SUITABLE battery Rack with Battery breaker switch, Cables, Interlinks, all accessories with freight and Installation, Including three year service by service provider of OEM and its confimity certificate submitted at the time of installation | - | each | - | - |
| 2Electrification for the installation of UPS | |||||
| 2.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | - | - |
| 2.002 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | - | metre | - | - |
| 2.003 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | - | metre | - | - |
| 2.004 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | - | metre | - | - |
| 2.005 | OD77342/2026-2027:SITC 1200 lumen round/ square(1X1) recessed fitting made of diecast aluminium body, polycarbonate diffuser, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea | - | each | - | - |
| 2.006 | OD77343/2026-2027:Supply and installation of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) | - | each | - | - |
| 2.007 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | - | each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1460738.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
mom1MAIN.pdf
Additional Documents • 0.74 MB
BOQ_1460738.xls
BOQ • 0.33 MB
specialconditionsmodified.pdf
Additional Documents • 0.15 MB
viewsbd.pdf
Additional Documents • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .