Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹30.9 L
EMD Value
₹62,000
Closing Date
18 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
PROVISION OF ELECTRIC ENERGY METER POWER SOCKET AND EARTHING FOR ELECTRIC VEHICLE CHARGING PROVISION OF ELECTRICAL CONNECTIONS WITH ALLIED WORK FOR PRODUCTION PRINTERS 4 NOS IN ROOM NO B14 AND 211 AT JCB BUILDING METCALFE HOUSE ANNEXE REPLACEMENT O
2025_MES_716361_3
GE/RND/T-06/DLI/2025-26
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat a(ii)
2 documents required · 2 mandatory
₹500
Yes
GE I RND Delhi
₹62,000
Yes
19 Nov 2025
19 Nov 2025
20 Dec 2025
19 Nov 2025
18 Dec 2025
26 Nov 2025
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, complete all as specified and directed
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out complete all as specified and directed.
Returning, filling in and including spreading, leveling watering and well ramming in layers in any type of soil not exceeding 25 cm to achieve desired compactness complete all as specified and directed
Removing surplus soil (material) to a distance exceeding 1.5Km and depositing where directed at a level not exceeding 5Km above the starting point complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks built in CM 1:4 straight or curved on plan exc 6M mean radius including demolition of old unserviceable brick work complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in roof kerbs or mud stops rounded or chamfered on edges etc including demolition of old PCC complete all as specified and directed.
M&L for PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate) in foundations filling and mass concrete including demolition of old PCC complete all as specified and directed
M&L for rendering 10 mm thick on brick work/concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed
M&L for cutting existing Gl tubing for alteration or addition of 40mm to 50mm including screwing existing Gl tubing for tapping & making new connection etc complete all as specified & directed.
S&F rotational moulded polythelene water storage tank (cylindrical vertical with Ea closed top) double layer of capacity 500 Itrs hoisted & fixed in position including taking down old unserviceable water tank complete all as specified and directed
S&F gun metal gate valve with iron wheel head screwed both ends for iron pipe, ISI marked as per IS: 778 of size 15 mm bore dia including taking out old unserviceable complete all as specified and directed
S&F in repair mild steel work such as MS Sheet, angle iron, flat iron etc including cutting, welding complete all as specified and directed.
M&L for preparation of new steel or iron surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete al as specified and directed.
M&L for wiring for circuit/submain wiring alongwith earth wire with 2 run 10.0 sqmm and one run of 10.0 sqmm as earth continuty conductor FRLS PVC insulated copper conductor, single core cablein surface/recessed as required. Note :- 2 run of 10 Sqmm cable, one run of 10.0 sqmm and one run of PVC conduit including cutting & chasing shall be measured as one unit.
M&L for point wiring as per site requirment with PVC insulated FR LS unsheathed copper conductor cable of size 2.5 sqmm including earth wire of size 1.5 Sqmm in and including concealed PVC conduit including MS bos suitable of modular fittings ,inner and outer modular top sheet top cover, for one 5 pin socket outlet 15 Amps independent all as specified .
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connections etc as required.
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers. GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
Supply and fix Single Phase digital electrical energy meter with electronic LCD display suitable for 0-30 Amp, 240 volts, AC 50 Hz of class accuracy 0.5
Providing and fixing 125 Amps 4 pole 16 KA breaking capacity MCCB with thermomagnetic release and thermal spreader in existing DB incl making connections as required.
Supply and fixing 6 A to 32 A rating rating 240/415 V, 10 KA "C" curve miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and comissioning etc as required.
M&L for wiring for circuit/submain wiring alongwith earth wire with 2 run 6.0 sqmm and one run of 6.0 sqmm as earth continuty conductor FRLS PVC insulated copper conductor, single core cablein surface/recessed as required. Note :- 3 run of 6 Sqmm cable and one run of PVC conduit including cutting & chasing shall be measured as one unit.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connections etc as required.
Supply and fixing 20 A , 240 V, SPN industrial type socket outlet, with two pole and earth, metal enclosed plug topalong with 20 A 'C' curve, SP, MCB, in sheet metal enclosure on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and comissioning etc as required.
S&F DLP U-PVC trunking system size 105 x 50 mm with all accessories for fittings including flexible cover complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
TDR.pdf
Tender Documents • 1.53 MB
BOQ_829282.xls
BOQ • 1.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .