Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC BEING ELIGIBLE AND LOWEST BIDDER | |
| 2 | L2₹37.9 L+₹2.6 L (7.47%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹42.2 L+₹7.0 L (19.9%)Rejected-Finance 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹44.6 L+₹9.4 L (26.7%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
31 Dec 2024, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
REPAIR/ MAINT OF AC PLANT AND SUMMER/ COOLING APPLIANCES AT MAKARPURA, HARNI CAMP AND HARNI AIRFIELD AT AFS BARODA
2024_MES_682041_2
8920/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MAKARPURA, GUJARAT-390014
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹80,000
Yes
31 Jan 2025
10 Dec 2024
2 Jan 2025
10 Dec 2024
31 Dec 2024
17 Dec 2024
Amount
Labour only for attending complaints of Air Conditioner carried out by manufacture's authorised mechanic from servicing center without any delay with rectified the defects by carefully opening and check the Acs for smooth functioning complete all as specified and directed. Note :- Items shall measure and paid seperatrly under respective item of BOQ.
M & L for annual servcing of split AC capacity 1.5/2.0 TR by disconnecting electric connection from its stabilizer or its electric supply board and remove the front cover or indoor split unit of AC and cleaning it with pressurised water and nylon brush, refix the front cover of indoor unit. including remove the front covert of outdoor unit with polythen/plastic cover so that water shall not be entered in the motorwhile cleaning the outdoor unit and cleaning the condensing coil unit with pressurised water then apply one coat of descaling solution and cleaning with nylon brush to the condensing coil of outdoor unit shall be properly carried out damaging other parts, cheking and making serviceable electrical connection of DB, stabiliser, wiring of AC as per site condition and tightening of loose connection complete.
Material and labour for flushing out system for leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner using CO2/ nitrogen Gas arrest of leakage with brazing of copper pipe including gas charging with using refrigerant R-22, oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction of Engineer-in-Charge.and retest again for rectification leakage on load complete all as specified
-ditto- but using gas charging with Gas R-32
-ditto- but using gas charging with gas R-410 a
Labour only for dust cleaning of dust filter of indoor unit to obtain maximum effeciency of split AC 1.5/2.0TR complete as per schedule complete. Note : dust cleaning of filter shall be required on every 45 day . Each cleaning is measured as one Job
NOTE FOR ITEM NO 1 to 46:- (a) All T & P/Stationeries and labour team required comprising of sufficient trained technician (Ref Mech/helper ) will be provided by the contractor daily for location ie Makarpura baroda area as directed. During MES mela or any other occason the contractor will be arrage additional menpower to rectify the complaint with justified time. b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, lubricating oil/grease etc shall be deemed included in the above quoted rate. However, major items such as Protecting relay, gas, capacitor, etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 1000/- per complaint will be penalised.
Material and labor for replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for replacement of unserviceable cut sealed compressor of split type ACs 2 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labour for replacement of unserviceable cut sealed compressor of split type Invertors ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labour for replacement of unserviceable cut sealed compressor of split type Invertors ACs 2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
M&L for gas charging R-410A with rectification of leakage of dehumidifier if any and make it serviceable complete all as specified and directed
Material and labour for replacement of defective wiring set (with suitable copper wire) of Split/window type AC cap. 1.5 Ton/2 Ton complete all as directed by EIC.
Cheking of refrigirent pressure of split AC system by using pressur gauge and topping up the refergirent gas to obtain pressure for R22 requires up to 60 to 65 PSI, R32 requires up to 110 to 120 PSI, and R410A requires up to 110 to 120 PSI and obtain desire level of cooling as per user satisfaction complete
Supply and installation of Insulation pipe highly flexible pipe closed cell nitrile rubber fitted on suction /discharge copper tubes of 1.5/2.0 TR split Acs including PVC self adhesive with monsoon tape over the insulation complete all as specified and directed
Material and labour for replacement of copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed
Material and labour for replacement of copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed
Material and labour for replacement of copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed
Material and labour for taking down and refixing split type of capacity indoor and outdoor unit of 1.5/2 TR from one site to another site complete all as directed by Engr-in-charge
Material and labour for repairing of PCB card for non-invertor type AC of cap 1.5/2.0 TR all as specified and directed.
Material and labour for repairing of PCB card for invertor type AC for indoor and outdoor unit both of cap 1.5/2.0 TR all as specified and directed.
Supply and replacement of following U/s items in split type AC: (Non invertor type AC)
Swing motor for indoor unit of window/Split Air conditioner of cap 1.5/2 TR
Condensor fan motor of Speed 900 RPM of window/Split Air conditioner of cap 1.5/2.0 TR
Running capacitor clip type of cap. 50/2+4+6 MFD, 240 volts 50 cycles for window type/Split type air conditioner 1.5/2.0 TR.
Over load protector with relay for 1.5/2.0 Ton cap for window/Split type AC.
Thermostat switch for window/Split AC cap.1.5/2.0 TR.
Cooper Cooling coil for indoor unit split type AC Cap.1.5 /2.0 TR.
Copper condenser unit (Heating Condenser) for out door unit for split type AC Cap.1.5 /2.0 TR.
Blade of condensing fan motor for window/split type (outdoor unit) AC cap 1.5/2.0 TR.
Connector unit
PCB Card for split type AC of capacity 1.5 TR
PCB Card for split type AC of capacity 2 TR
Remote hand set for split type AC 1.5/2 TR Capacity
Valve 1/2 " ,1/4 " and 5/8 " for split type of capacity 1.5/2.0 TR
Cooling coil and room temperature sensor
Display unit for 1.5/2 Ton AC
Blower motor of indoor unit of split type of cap 1.5 /2 TR.
PT relay for split type Acs of Capacity 1.5/2 TR.
Airfilter for split type ac for 1.5/2 TR.
Outdoor unit jali for split type ac for 1.5/2 TR.
Outdoor fan motor as per existing for 1.5/2.0 Ton Spilt AC
Compresser Capacitor as per existing for 1.5/2.0 Split type AC
Swing Patti as per existing for 1.5/2.0 Split type AC
Drain pipe as per existing for 1.5/2.0 Split type AC
PCB Transformer as per existing for 1.5/2.0 Split type AC
Supply and Replacement of following U/s items in split type AC: (Invertor type AC)
PCB card for indoor and outdoor unit both for 1.5/2.0 Ton Invertor type AC as per existing
Fan motor of 1.5/2.0 Ton split type invertor Acs as per existing.
Outdoor heating condenser of 1.5/2.0 Ton split type invertor Acs as per existing.
Sensor of 1.5/2.0 Ton split type invertor Acs as per existing.
Control remote of 1.5/2.0 Ton split type invertor Acs as per existing.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete. Note:- i) Old sealed compressor received from the water cooler will be property of contractor ii) The ate quoted by the contractor including all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition iii ) The new sealed unit will be purchased from authorized dealer.
Material and Labour for Replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hr
Material and Labour for Replacement of relay with over load protectors for 40 Ltr/hr cooling capacity suitable as per site requirement.
Material and Labour for Replacement of condensor fan of motor HP- 1/32 ,RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade.
Material and Labour for Replacement of thermostat switch with knob for water cooler. having cooling capacity 40 Ltrs / hr.
Material and Labour for Replacement of starting capacitor 40/60 Mfd oil filled 240 volt AC Supply.
Material and Labour for Replacement of running capacitor of 10 Mfd oil filled.
Material and Labour for brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple directed by Engineer -In -charge
Material and Labour for replacement of top cover of water cooler with rubber beading, hinges screws etc complete for 40 Ltr/Hr cap. water cooler all as specified and directed by Engineer -in-charge.(As per sample)
Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with supper enameled copper wire of suitable gauge (Make: Devidayal/Chetak/Atlatcomplete incl. insulating material and replacement of gun metal bush & capacitor 2.5 MFD.
Material and labour for replacement of fan blade for condensing fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/Hr water cooler.
Material and Labour for condenser unit complete suitable for 40 Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with suitable refrigerant, oil charging complete in compressor of water coolar all as directed & with entire satisfaction of Engineer-in-Charge. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour Desert Cooler fan motor 3 speed,1400 RPM of cap. 1/5 HP with super enameled copper wire of appropriate size . Make-crompton greaves, Havells
Material and labour for replacement of oil filled type capacitor for fan motor cap. 4 MFD , 240 volts suitable for desert cooler fan motor.
Material and Labour for replacment of Bottom water tank of size 750x750x200 mm fabricated out of 18 gauge PGI sheet.incl nuts bolts and washers etc
Material and labour for replacement of side supporting columns to be fabricated out of 20 gauges PGI sheet of size 80x80x800 mm incl. necessary nut, bolts etc .or as directed by EIC.
Material and labour for replacement of side panal made out of 22 gauge PGI Sheet with suitable handles including painting to match with the existing desert cooler all as directed by EIC. (As per sample)
Material and labour for replacement of top cover made out of 22 gauge PGI Sheet including painting to match with the existing desert cooler all as directed by EIC. (As per sample)
Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etc complete all as specified and directed by engineer-in-Charge at site and office yard
Material and labour replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt
Material and labour for replacement of Wood / wool chips pad for Desert Cooler of size 00 x 550 x30 mm (set of three pads) superior quality .
Material and labour for replacement of supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers complete.
Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area superior quality .
Material and labour for replacement of PVC water distributor of 3 out lets with MS nuts & bolts complete (as per sample)
Material and labour for replacement of PVC elbow set for each vcooler suitable for desert cooler (as per sample)
Material and labour for replacement of PVC pipe 15 mm dia heavy duty for D/Cooler Pump.
Material and labour for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz.
Material and labour for replacement of motor fixing ring for desert cooler eight screw / clip type(asper sample)
Supply and fix voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.Make: V guard VND 500 or equivalent in blue bird or microtech. Note: rates for fixing of existing ACs and power supply via volatge stabilizer deemed to be considered in quoted rates.
Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas(between inner cooling cabin and outer fabrication) , Oil complete incl. testing and commissioning of deep frezzer of capacity upto 300 Ltrs of any make complete all as directed by EIC. Note: Spares to be used in repair,gas charging and transportation to workshop and back to site shall be deemed to be considered in quoted rates.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for deep freezer of capacity 300 Ltrs with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland ) Note i) Old sealed compressor received from the water cooler will be property of contractor (ii) The rate quoted by the contractor including all charges like transportation, filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition. ( iii ) The new sealed unit will be purchased from authorized dealer.
Supply, fixing and fabricated and testing desert cooler in GI body sheet with and including cooler fan motor size/Sweep 450 mm (fan blade only) 230 V single phase 50 Hz, 1400 RPM, heavy duty single sheet, totally enclosed. The overall dimensions of the deset cooler shall not be less than 690mmX690mmX1020mm with and including following accessories each. (a) Air grill of suitable size made out of 0.5 mm PGI sheet including GSS arrangment with a knob for easy and smooth movement. (b) Front & Side panel made out of 1mm thick PGI Sheetof Sitable size and shape. (c) Water tank height should not less than 11 inch made out of 2 mm thick PGI Sheet. (d) Submersible pump electric driven single phase 230 v , 50 Hz of suitable and head but motor capacity not less than 18 watt. Make-Khaitan/Crompton or equivalent. (e) Servie cord of 3 Core Copper wire 1.5 Sqmm with plug top 5 Amps lenght not less than 2 m. (f) Electric fan dimmer 1000 watts AC 239 V for controlling the fan speed. (g) Complete electric wiring of desert coolers as required to operate fan and pump along with 5 Amps Swithes. (h) Make of cooler fan motor :- Khaitan/Haveels/Cropmton (j) Make of PGI Sheet. Tata/Jindal/National
Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 310/280 Ltr. Capacity with fresh new uncut sealed compressor including +suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized dealar.
All as per ser item No.58 above but for 165/170/180 Ltr capacity refrigerator.
Material and labour for replacement of relay suitable for 280/310 Liters cap.refrigerator.
all as per ser item No 60 but cap 165 Ltrs. Refrigerator
Material and labour for replacement of thermostat automatic `R' frost with knob suitable for 165/286/310 liters cap refrigerator (Make :-Anpurna/Indofos)
Material and labour for replacement of door gasket of best quality complete suitable for 280/310 liters cap. refrigerator as per manufacturer's instruction and as directed by EIC.
All as per ser item No.63 above but for 165/170/180 Ltrs Cap.
Material and labour Bulb for pin /screw type , 230 Volts suitable for 280/310 Ltrs Cap. refrigerator as in replacement.
All as per ser item No.65 above but 165/170/180 Ltrs capacity.refrigerator
Material and labour for replacement of refrigerator door handle of 165/ 280/310 Ltrs Cap. of any make.and model
Material and labour for replacement of freezer assy (including gas charging R-134/600 ) complete with screw, jointing of tubes etc. and testing of cap. 280/310 Ltrs. refrigerator (any make)
All as per ser item No.68 above but of capacity 165/170/180 Ltr refrigerator.
Material and labour for replacement of condensor unit of refrigerator cap. 280/310 Ltrs of any make incl. jointing of tubes and testing etc. complete.(gas charging will be measure and paid under relevant item separately )
All as per ser item No.70 above but for 165/170/180 ltrs capacity refrigerator.
Material and labour for replacement of timer of refrigerator cap. 280/310/165 Ltrs of any make and all as directed by Engr-in-charge.
Material and labour for replacement of PCB of refrigerator cap. 280/310/165 Ltrs of any make and all as directed by Engr-in-charge.Hitachi/Voltas
M & L for replacement of cooling coil of refrigerator cap 280/310/165 Ltrs as per existing and all as directed by EIC.
M & L for replacement of capilary of refrigerator cap 280/310/165 Ltrs as per existing and all as directed by EIC.
Dimantling old u/s warnout outdoor unit of AC Cap 1.5 TR and supply and Fix new outdoor unit with inverter technology star rated in repalcement as per existing make including compressor suitable for 1.5 TR tonnage and all controls complete all as specified and directed.
Description all as per item Ser No 76.00 here-in-before but for 2 TR capacity complete all as specified and directed
Dismantling old u/s indoor unit of AC Cap 1.5 TR and supply and fix new indoor unit with invertor technology star rated in repalcement as per existing make and 1.5 Ton rating including filters, remote control, control wiring etc complete all as specified and directed.
Description all as per item Ser No 78.00 here-in-before but for 2 TR capacity complete all as specified and directed
Labour for checking and finding the defect of Dehumidifier, Auto Humiditiy sense test, Pressure test, Leak testing of Dehumidifier including cleaning and descaling installed at 57 ASP Storage Bldg and LLQRM Buildings for maintating the required humiditiy all as specified and directed as Engr-in-Charge. Note :- Items shall measure and paid seperatrly under respective item of BOQ.
Supply and fix Power Circuit Board for controliing all parameters of Dehumidifier such as temperatute, humidity, etc. all as specified and directed.
Material and labour for replacement of Condenser Fan motor of speed 600 RPM suitable for dehumidifier all as specified and directed.
Material and labour for replacement of Condenser Fan motor Rotational Blade suitable for dehumidifier all as specified and directed.
Labour only for attending complaints of Air curtain carried out by manufacture's authorised mechanic from servicing center without any delay with rectified the defects by carefully opening and check the Air curtainfor smooth functioning complete all as specified and directed. Note :- Items shall measure and paid seperatrly under respective item of BOQ.
Material and labour for replacement of fan Blower motor suitable for air curtain all as specified and directed.
Material and labour for replacement of Power circuit board suitable for Air curtain all as specified and directed.
Material and labor for rewinding of blower motor of Speed 900 RPM of window/Split Air conditioner of cap. 1.5/ 2 ton any make with super enameled copper conductor including replacement of worn out bushes ,Shaft and capacitor etc and testing complete all as specified and directed
S&F digital AC Timer Unit Meant for Cyclic Operation of two any type Air Conditioner each AC can be kept On from 01 hr to 24 hr (Max in this Unit) AC on condition is showm by their respectivE display.Company provides 12 months unconditional warranty. It has LCD fully digital display can see all parameter like AC1 on/AC2 on, balance time and set timer, AC1 Manual/AC2 Manual facility also provided all as specified and directed.
Labour only for attending complaints of Air conditioner Plant of 22 TR/11 TR each carried out by manufacture's authorised mechanic from the servicing centre without any delay with rectified the defects by carefuly opening and check the ACs parts which defects find out at site and replace the defected parts from the ACs for smooth functioning complete all as specified and directed Note :- Supply only item shall be measure and paid seperately under respective item of BOQ
S&F in repair of copper piping with fittings for hot gas line from package AC unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 5/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of copper piping with fittings for liquid line from package AC unit to outdoor condenser unit, hard copper pipe of 18 guage having size of 7/8" with supporting accessories and painting complete all as specified and directed.
S&F in repair of cath all driers 5/8"x5/8" for package type AC complete all as specified and directed.
S&F in repair of ball valves 5/8" in liquid line for package type AC complete all as specified and directed.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-407C complete in compressor package type AC plant capacity 11TR Ton with entire satisfaction of Engineer-in-Charge complete all as specified and directed.
S&F in repair of motor protection device (MPD) rating 11 to 30 Amp with display suitable for package type AC of capacity 22 TR complete all as specified and directed.
Material and labour for servicing/ overhauling with chemical wash of package type AC capacity 22 TR/11 TR for each Unit complete all as specified and directed.
Material and labour for rewinding of blower motor of 5 HP 3 Phase 415 V package type AC capacity 22 TR with super enameled copper conductor including replacement of worn out bushes, Shaft etc and testing complete all as specified and as directed.
Material and labour for rewinding of condensor fan motor of package type AC capacity 22 TR with super enameled copper conductor including replacement of worn out bushes ,shaft and capacitor etc and testing complete all as specified and as directed.
Supply and fix in repair of contactor CE certified for 5 HP motor starter 415 V, 50 Hz capacity for blower motor of AC plant of capacity 22 TR complete all as directed by Engineer-in-Charge.
Supply and fix in repair of contactor CE certified for 11 TR compressor 415 V, 50 Hz capacity for AC plant complete all as directed by Engineer-in-Charge.
Supply and fix Voltas PKC Unit Display of 22 TR Unit of AC Plant for controliing all parameters of AC plant Unit such as temperatute, humidity, timer, pressure, temperature, etc. all as specified and directed.
Supply and fix Outdoor Unit Fan Blade od Condenser of AC Plant all as specified and directed.
Dismantling old 40/80 ltrs water cooler and Supply and fix new water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed
Attending complaint of leaking of water indoor unit of 1.5 TR/ 2 TR AC, dismantling the front cover cleaning of duct / dirt from duct of the indoor unit tighten the water pipe and refixed the same in position complete all as specified and directed
Supply and fix heavy duty Air conditioner outdoor unit mounting bracket for AC 1.5/2.0 TR complete all as directed by Engineer-in-Charge
M/S TANUSHREE CONSTRUCTION COMPANY (BID ID -3196625)
FAIZA ENTERPRISE (BID ID -3194468)
ARTI CONSTRUCTION (BID ID -3201340)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .