The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
Harbour Engineering Department - Ernakulam Division Office Providing E-Office facilities and Lighting Upgradation
2022_HED_500424_1
19/HEED/2022-23/S
Open Tender
Electrical Works
Item Rate
30 days
ERNAKULAM
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,150
₹12,200
15 Oct 2022
20 Jul 2022
9 Aug 2022
20 Jul 2022
6 Aug 2022
20 Jul 2022
Amount
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required
Providing and fixing 0.3 m , 20 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessoriesand separators as per the site condition on surface/recess including switch plate
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
Identifying cables, supply and crimping RJ 45/RJ 11 cable jack on the cable end and giving connection
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.RJ 45 Frame
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.CAT 6 RJ 45 computer data socket
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc. as required.6 Module base and cover plate.
Supplying and fixing following Modular base & cover plate on existing existing CMS 105X50mm. as required.1 or 2 Module base and cover plate
Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc. as required.3 Module base and cover plate.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of 230V AC, 50HZ ,3KVA IGBT based PWM technology microprocessor controlled double conversion true Online UPS(96 V CD or above) capable for automatic changeover from mains to UPS on mains failure and vice versa with built in isolation transformer of make APC/NUMERIC/GE or equivalent suitable to work with 8Nos 12V,100 Ah,rated tubular type battery bank C10 for UPS application suitable for 3 hours backup on full load.Single phase Input Voltage Range 160- 300 V AC, Output Frequency-50 ±. 01Hz,Output voltage Range :230VAC ± 1% ,Output power rating:2400W/3000VA,Interface port:RS232 and com port,Front panel Display: LCD ,input power factor:0.99, input Current THD < 3%(Linear Load),THD =90%,Overload capacity :1min @ 111%-130% of rated load,10 minut @ 105%-110% of rated load,Load power factor: 0.8 lag or better,Load crest factor : 3:1, Noise level:<50 dBA at 1 meter, Continuous Operating Temperature: 0-40 °C,Constant current & constant Voltage with optional Temperature compensated battery charging. Standards: EMC- EN 62040-2, Safety- EN 62040-1, Performance- IEC 62040-3, Certifications: BIS,OSHAS,CE,PeP,RoHS, ISO 9001 & ISO 14001, Warranty :3 years on site warranty from the date of installation
Supply, installing HENSEL telephone junction box K9250 size 200x160x98 mm having 20 pair KRONE type telephone wire connector suitable for 0.50 mm dia copper wire of approved quality mounted on a suitable G.I. frame. All the telephone wires are to be identified and terminated on the block as per the colour code using the special crimping tool as per the instruction of the departmental officer.
Supply of EPABX SYSTEM Equipped for 12 Extensions & 04 Trunk Line,Expandable Upto 16 Extensions & 6 Trunk Lines,Caller – ID Internal / External / Transferable,Caller – ID On Simultaneous Ringing,Dialed Number Shown as Caller – ID, Call Progress Visual Indicatio,Printout of Answered /Unanswered /Dialed Calls,Welcome Message,Hundred Memory Locations,Computer Connectivity for Call Management,Auto Redia,lRemote Maintenance,Auto Fax – Telephone Switch*Built – in Printer Interface With Buffer Interface,Various Options For SMDR Printing,Call Forwarding Call Waiting on P & T Lines,Various Extension Hunt Groups,Operator Less Operation,Intercom,Direct Outward Dialing, Call Forward On No Answer, Call Forward On Busy, Call Redirection to External Numbers,Barge in With or Without Tone,Distinctive Ring For External / Internal,Trunk Status Indication,Day / Night Service Operation,Automatic Padlock,Simultaneous Cyclic Ring for Incoming Calls
Supply of Lightning Protector for 4 Trunk Lines
Supply of Neo power protection for AC power
Supply of Cat 6,2 metre patch cord
Supply of Cat 6,1 metre patch cord
Supplying 20 W LED Tube with box type fixtures Essential LED tube 1200 mm 20W 865 T8 API Philips or equivalent
Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
Supply and laying bare earthing copper conductor 10 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Supply, installation, testing and commissioning of rack mountable 24 PORT GIGABIT manageable Network switch having 24 XIG 10/100/1000 and 4 XIG SFP Ports with switching capacity of 56 Gbps upto 8 groups with 8 ports/group (max) LACP Support upto 4094 VLANs simultaneously, PVE, Guest VLAN, GVRP, GARP, unidirectional Link Detection, SSH protocol and SSL Support RADIUS, Remote and Web based authentication BPDU guard, STP Root and loop back guard, DHCP Snooping protection, IP Source guard, DAI, IPMB, SCT, SSD, Private LAN, PVE with community LAN, MAC based Port Security, Storm Control, DoS prevention, ACLs, QoS upto 8 hardware queues, Scheduling, 802 Ip/Cos, Rate limiting. This shall conform to the following Standards. IEEE 802.310 BASE-T Ethernet, IEEE 802.3u 100 BASE-TX Fast Ethernet, IEEE 802.3ab 1000 BASE-T Gigabit Ethernet, IEEE 802.3ad Link Aggregation Control Protocol, IEEE 802.3z Gigabit Ethernet, IEEE 802.3ae 10 Gbit/S Ethernet over fiber for LAN, IEEE 802.3 an 10 GBase-T 10 Gbit/s Ethernet over Copper twisted pair cable. Preferred make : CISCO 350-24T-4G
Supply, installation testing and commissioning wall mounting type dust and vermin proof enclosure 9 U rack system with standard accessories patch panel,cable manager , power strip, cooling fan, cable tray (Model 9U) suitable for installing 24port Ethernet switch and patch panel.
Wiring the patch panel and Configuring of Managable network switch complete
Supplying LED luminatre Philips SM 270 C LED 30S 6500 PSU WH or equivalent.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescentfitting of all types, complete with all accessories and tube etc., including supplying and fixing balland socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cmlength, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated,copper conductor, single core cable and earthing etc. as required.
Conveyance, installation, testing and commissioning of pre-wired fluorescent light fittings with all accessories and fluorescent lamps of all types directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
Supply Push Button Telephone Preferred make ; Beetel C-11
Supply Push Button Telephone. Preferred makeBeetel C-51 CLI Phone
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
Supply and fixing 5W/ 9 W LED ,BC, lamp OSRAM or equivalent
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply of 5 ' high pedestal fan 100 watt 18" sweep 450mm with standard accessories without regulater preferred make Almonard .
Supply of wall mounting fan of 18" sweep 450mm 80w with 3 speed as per standard and accessories.preferred make ALMONARD.
Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required.
Engaging helper for disconnecting and removing the existing wiring and reconnecting as necessory.
Engaging Electrician -for disconnecting, and removing the existing wiring and repulling and giving connections as necessory
Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
TELCON Infrastructures
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_717184.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .