Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.5 L+₹19,268.75 (1.00%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹36,800
Closing Date
20 Mar 2023, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2023_MES_582314_1
8707
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹36,800
Yes
1 Apr 2023
22 Feb 2023
21 Mar 2023
22 Feb 2023
20 Mar 2023
27 Feb 2023
22 Feb 2023 - 27 Feb 2023
Amount
Supply, install, connecting and testing of water cooler fully stainless steel non- corrosive electric driven (single phase) having approx storage capacity 80 Ltrs self contained drinking water cooler with (Non - CFC refrigerant) energy efficient compressor and nominal cooling capacity of 40 Ltrs/Hrs, two nos faucets including connecting of incoming GI pipe medium grade and gate valve of suitable size with necessary PVC Nylon braided pipe, PCC platform including draining water provision etc. complete all as specified and directed.
Supply and fix refrigerator, electric driven (single phase), capacity 315 Litres, BEE 5 star rated, 230 V, 50 Hz complete all as specified and directed
Supply and install hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating invertor type and EER 3.2 of capacity 1.5 TR with all accessories and Brackets complete all as per manufacturers instruction,and as specified and directed including dismantling of any type or capacity of existing Split AC (Indoor and Out door unit). Note : (i)The split AC shall carry minimum 5 star rating as per Bureau of energy Efficiency (BEE) labelling programme (ii) Old Split AC units shall be handed over to AGE E&M store yard.
Supply and fix room window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour ( 1.5 Ton).BEE 5 star rated with all accessories complete all as per manufacturers instruction,and as specified and directed including dismantling of any type or capacity of existing Window AC . Note :(i)The Window AC shall carry minimum 5 star rating as per Bureau of energy Efficiency (BEE) labelling programme (ii) Old Window AC shall be handed over to AGE E&M store yard.
Supply and fix room window type air conditioner electric driven (single phase), cooling capacity 6000 K Cal per hour ( 2 Ton).BEE 5 star rated with all accessories complete all as per manufacturers instruction,and as specified and directed including dismantling of any type or capacity of existing Window AC . Note :(i)The Window AC shall carry minimum 5 star rating as per Bureau of energy Efficiency (BEE) labelling programme (ii) Old Window AC shall be handed over to AGE E&M store yard..
Supply, install, testing and commissioning of Pumping sets, Centrifugal, electric driven, (flow and head) 1200 LPMX 40 mtr of capacity not less than 30 HP (15 WHP), 3 phase, 415 volts, 50 Hz with steel impeller including cables, earthing, 3 phase star delta starter for electric motor and PCC foundation, including taking down / dismantling old U/S pump and motor complete all as specified and as directed Note:- Old pump and motor shall be handed over to AGE E&M store yard
M & L for Sub main wiring with FRLS four run of 10.0 Sqmm size single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694 marked, drawn through and including suitable size of PVC open conduit medium grade ISI marked not less than 32 mm dia, and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including two run of 10.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor including Taking down existing sub main wiring and accessories. Note : Four runs of single core 10.0 sqmm and two run of 10.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
M & L for Sub main wiring with FRLS four run of single core 6.0 Sqmm size PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694 marked, drawn through and including suitable size of PVC open conduit medium grade ISI marked not less than 32 mm dia,and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor including Taking down existing sub main wiring and accessories. Note : Four runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
M & L for Sub main wiring with FRLS two run of single core 6.0 Sqmm size PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694 marked, drawn through and including suitable size of PVC open conduit medium grade ISI marked not less than 25 mm dia,and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor including Taking down existing sub main wiring and accessories. Note : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
M & L for Sub main wiring with FRLS two run of 4.0 Sqmm size single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694 marked, drawn through and including suitable size of PVC open conduit medium grade ISI marked not less than 25 mm dia,and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. Note : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper conductor FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Supply and fix CRCA sheet metal enclosures distribution board double door,TPN vertical DB 4 way suitable for fixing of Four pole MCCB as incommer & MCBs SP as out going and duly fitted with Bus bar, neutral link, blanking plates, conforms IS 8623-1 & 3, IEC 61439-1 & 3, IK 09 etc complete.The DB shall be included with one No MCCB, 4 pole, 415/430 Volt, 50 Hz, Ics=100% of Icu, having rupturing capacity 36 kA on 415 V icu of capacity 160 Amps complete all as specified and directed. Encloser & MCCB shall preferably of same make. ( MCB s required for out going shall be measured and paid seperately)
S & F MCB DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V complete includind taking down existing DB all as directed by Engr-in-charge.
S & F MCB single pole, having rupturing 10KA, 6 amps to 32 amps as ordered 240 Volts
S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered.
S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240 V 63 amps as ordered.
Supply & fix metal clad box with plug and socket 20 Amps with one MCB SPN of 20 Amps complete all as specified and directed
M & L for Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and earthwork in any type of soil strata, testing on completion, complete all as specified and directed
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles, or laying / taking out of cables/stay/strut etc or for shafts, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/loose soil complete
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete
Returning filling in excavated approved soil including spreading, leveling, watering and well ramming in layers n.exc 25cm in soil completed all as specified and directed
Supply and laying dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete punned to 18 cm thick all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
M & L for Sub class `B` old size bricks laid dry, flat transversely along the length of cable with width equal to the length of bricks as protection cover of cable laid, complete all as specified and directed.
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 50 sq. mm 3.5 Core nominal cross section in service connections .
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 70 sq. mm 3.5 Core nominal cross section in service connections including taking down existing cable.
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 150 sq. mm 3.5 Core nominal cross section in service connections including taking down existing cable.
M & L for galvanized steel tubing light Grade of 40 mm dia as protection of cable fixed to pole/walls or laid in floors, road crossing, ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Supply & Fix replacement of MCCB 4 Pole, 415 V,adjustable type, 160 Amps with breaking capacity 36 KA, make & model as per site requirement complete including taking down existing MCCB all as specified and directed
BK CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .