Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAdmitted-Finance 5 NIYAL BHAWAN OPPOSITE ROYAN IN FILED SHOWROOM JHULAGHAT ROAD BIN BRANCH PO BIN PITHORAGARH PITHORAGARH UTTARAKHAND 262501 | PITHORAGARH | UTTARAKHAND | 262501 | ₹12.8 L | L1 | Admitted-Finance |
| 2 | L2₹13.6 L+₹76,221.60 (5.94%)Admitted-Finance 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹13.6 L+₹76,221.60 (5.94%) | L2 | Admitted-Finance |
| 3 | L3₹13.7 L+₹90,993.30 (7.09%)Admitted-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | ₹13.7 L+₹90,993.30 (7.09%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s J P Traders L3 | M/S M K CONSTRUCTION L1 | om enterprises L2 |
|---|---|---|---|---|---|---|
| .05DESCRIPTION OF ITEMS | ||||||
| 1.00 | Demolition of cement concrete in ground floor,paving nexc 15cm thick(below or above GL) complete all as specified and directed. | 1.13 | Cum | 550 ₹621.5 | 500 ₹565 Lowest | 500 ₹565 Lowest |
| 2.00 | M&L providing cement concrete type B0, 1:2:4 (12.5mm aggregate) in roof kerbs or mud stops,coping, rounded or chamfered on edges complete all as specified and directed. | 1.13 | Cum | 6,500 ₹7,345 | 6,000 ₹6,780 Lowest | 9,000 ₹10,170 |
| 3.00 | M & L water proofing treatment on existing roof including removing exisitng treatment/screed bed,roughening etc. with the following speification complete
(a) M&L for 15mm thick screed bed in CM 1:4 on roof surface finishing the surface using extra cement incl water proofing compound(water proofing compound to be measured and paid for separately). (b) Apply bituminous primer @ 0.5 Ltr/Sqm confirming to IS 3384-1965 on prepared surface till the surface is properly pregnated.
(c) Apply hot bitumen 85/25 grade @ 1.2 Kgs/Sqm confirming to IS 702-1988. (d) Laying App based polymeric water proofing membrane minimum weight not less than 3.0 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (Wt not less than 150 gms/sqm) laid on primed surface by forced application complete with as per manufacturer instructions confirming to IS complete all as specified and directed. (e) Applying a coat aluminium paint min. 0.20ltr/sqm as per manufacturer's instructions. | 500 | Sqm | 800 ₹4,00,000 | 790 ₹3,95,000 Lowest | 900 ₹4,50,000 |
| 4.00 | M&L for sunken floor treatment as described as under (i) to (vi) :-
(i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type,filled in sunken portion & cleaned the sunken portion incl dismantling plastering wall surface complete as directed.
(ii) M& L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:4) 15 mm thick mixed with water proofing compound as per manufacturer instructions(water proofing compound to be measured and paid for separately). Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed.
(iii) Spouts of 40mm dia GI pipe medium grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed.
(iv) After laying sewage/ plumbing pipes with fixtures in position 2 coats of EP-101 epoxy compound shall be applied complete all as specified and directed.
(v) The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed, the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.
(vi) The sunken floor shall again be filled with PCC (1:5:10) type E-2 using over the treated surface upto top for fixing of WC complete all as specified and directed.
Note -
Mode of Measurement (i) Sunken slab to be treated up to 450 mm depth.
(ii) Bottom area of sunken slab will only be measured for qty calculation and payment | 10 | Sqm | 5,100 ₹51,000 | 5,000 ₹50,000 | 1,200 ₹12,000 Lowest |
| 5.00 | Supply only liquid water proofing compound | 18.93 | ltr | 100 ₹1,893 | 80 ₹1,514.4 Lowest | 80 ₹1,514.4 Lowest |
| 6.00 | Demolition of brick work, stone/boulder masonary built in cement mortar complete all speecified and directed | 20 | Cum | 500 ₹10,000 | 400 ₹8,000 Lowest | 500 ₹10,000 |
| 7.00 | M&L for Pre-cast cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. | 20 | Cum | 6,000 ₹1,20,000 | 5,500 ₹1,10,000 Lowest | 8,000 ₹1,60,000 |
| 8.00 | Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed. | 100 | Sqm | 50 ₹5,000 | 40 ₹4,000 | 20 ₹2,000 Lowest |
| 9.00 | M&L 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces fair and even without using extra cement complete all as specified and directed. | 30 | Sqm | 300 ₹9,000 | 250 ₹7,500 | 220 ₹6,600 Lowest |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
26 Aug 2026, 6:00 pmClosed
GE PITHORAGARH
GE Pithoragarh Post - Bharkatiya Pithoragarh-262520
GE/PGH/65 of 2026-27 (8809/PGH/E8)
2026_MES_781284_1
GE/PGH/65 of 2026-27 (8809/PGH/E8)
Open Tender
Civil Works
Item Rate
240 days
GE PITHORAGARH
Please ref Tender Document
7 documents required · 7 mandatory
₹500
GE PITHORAGARH
₹26,000
Yes
11 Sept 2026
28 Jul 2026
2 Sept 2026
28 Jul 2026
26 Aug 2026
12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.05 | DESCRIPTION OF ITEMS | - | - | - | - |
| 1 | Demolition of cement concrete in ground floor,paving nexc 15cm thick(below or above GL) complete all as specified and directed. | 1.13 | Cum | - | - |
| 2 | M&L providing cement concrete type B0, 1:2:4 (12.5mm aggregate) in roof kerbs or mud stops,coping, rounded or chamfered on edges complete all as specified and directed. | 1.13 | Cum | - | - |
| 3 | M & L water proofing treatment on existing roof including removing exisitng treatment/screed bed,roughening etc. with the following speification complete
(a) M&L for 15mm thick screed bed in CM 1:4 on roof surface finishing the surface using extra cement incl water proofing compound(water proofing compound to be measured and paid for separately). (b) Apply bituminous primer @ 0.5 Ltr/Sqm confirming to IS 3384-1965 on prepared surface till the surface is properly pregnated.
(c) Apply hot bitumen 85/25 grade @ 1.2 Kgs/Sqm confirming to IS 702-1988. (d) Laying App based polymeric water proofing membrane minimum weight not less than 3.0 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (Wt not less than 150 gms/sqm) laid on primed surface by forced application complete with as per manufacturer instructions confirming to IS complete all as specified and directed. (e) Applying a coat aluminium paint min. 0.20ltr/sqm as per manufacturer's instructions. | 500 | Sqm | - | - |
| 4 | M&L for sunken floor treatment as described as under (i) to (vi) :-
(i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type,filled in sunken portion & cleaned the sunken portion incl dismantling plastering wall surface complete as directed.
(ii) M& L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:4) 15 mm thick mixed with water proofing compound as per manufacturer instructions(water proofing compound to be measured and paid for separately). Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed.
(iii) Spouts of 40mm dia GI pipe medium grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed.
(iv) After laying sewage/ plumbing pipes with fixtures in position 2 coats of EP-101 epoxy compound shall be applied complete all as specified and directed.
(v) The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed, the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.
(vi) The sunken floor shall again be filled with PCC (1:5:10) type E-2 using over the treated surface upto top for fixing of WC complete all as specified and directed.
Note -
Mode of Measurement (i) Sunken slab to be treated up to 450 mm depth.
(ii) Bottom area of sunken slab will only be measured for qty calculation and payment | 10 | Sqm | - | - |
| 5 | Supply only liquid water proofing compound | 18.93 | ltr | - | - |
| 6 | Demolition of brick work, stone/boulder masonary built in cement mortar complete all speecified and directed | 20 | Cum | - | - |
| 7 | M&L for Pre-cast cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. | 20 | Cum | - | - |
| 8 | Taking down cement plaster on brick or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed. | 100 | Sqm | - | - |
| 9 | M&L 10mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces fair and even without using extra cement complete all as specified and directed. | 30 | Sqm | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
BOQ_875217.xls
BOQ • 0.75 MB
TenderDocument65.pdf
Tender Documents • 1.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .