Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | L1 | Accepted-AOC Ok | |
| 2 | L2₹16.8 L+₹89,478.48 (5.61%)Rejected-AOC | L2 | Rejected-AOC Ok | |
| 3 | L3₹17.7 L+₹1.7 L (10.9%)Rejected-AOC | L3 | Rejected-AOC Ok | |
| 4 | surinder kumar jindal bros L4₹19.3 L+₹3.3 L (20.8%)Rejected-AOC | L4 | Rejected-AOC Ok |
Tender Value
₹20.5 L
EMD Value
₹40,940
Closing Date
27 Jan 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (HP)
SPECIAL REPAIR TO BLDG NO M 10 (COY OFFICE) AND PROVN OF TWO NO. OF COVERED SHED FOR BATHING POINT NEAR BLDG NO. OW 07 AT PALAMPUR MIL STN
2019_MES_305124_2
GEP-58(Token)/2019-20
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender docus
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹40,940
Yes
29 Jun 2020
2 Jan 2020
28 Jan 2020
2 Jan 2020
27 Jan 2020
6 Jan 2020
Amount
SCHEDULE 'A' PART-I: Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) n.exc 1.5 Sqm each complete
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but n exc n.exc 4 Sqm each complete.
Taking down cement plaster on brick work or stone walls, etc including wall tiles, raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified.
Dismantling plain or corrugated steel sheeting any gauge thickness incl Nanital or similar type pattern roof coverings
Dismantling of Ceiling Boards (fibre, pulp, insulation etc) or insulation boards /slabs /blankets, any thickness , including cover fillets etc complete all as spd and directed.
Dismantling unframed work timber scantlings 40 sqcm & over in section , in any position
Dismantling unframed work in fillets, rails, posts, rafters, purlins, scantling etc under 40 sqcm in section
Demolition of stone/boulders or brick masonary built in cement mortar incl all quoins, arches, pillars, etc but excl ashler facing , dresses, stone work and precast concrete articles etc, complete all as specified.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified & directed.
Plain cement concrete, M-15 type B-1 (using 20 mm graded crushed stone aggregate) as in surface channels or drains complete, all as specified.
M&L for 25 mm thick PCC 1:2:4, type B-O (using 12.5 mm graded crused stone aggregate) as in floors finished rough to receive floor finishes, complete all as specified.
M&L for Non skid ceremic coloured tiles 7 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified.
M&L for Glazed ceramic coloured tiles 300 mm x 450 mm x 5 to 6 mm thick as in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match over and includind 10 mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 20 mm thick screed bed in cement mortar 1:4 to receive tiles, complete all as specified.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10 mm thick in cement mortar 1:3 to receive tiles, complete all as specified.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base, complete all as specified and directed.
M&L for coloured chequered cement concrete tiles 25cm X 25cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement with pigments including 15 mm thick screed bed in cement mortar 1:4 complete all as specified.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections)incl distance pieces, cleats, etc confirming to Fe-290(Grade E-165) complete all as specified. .
Excavation in post holes (or similar holes) in any type of soil, n exc 0.5 cum getting out , returning , filling, in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , complete all as specified.
M&L PCC type C-2 1:3:6 (40mm graded aggregate) cement concrete in foundation, filling and mass concrete
S&F for Steel work in tubular trusses incl special shaped washer etc, complete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240, complete all as specified.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified.
M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in CM 1:6 finished the surface even and smooth (without using extra cement on internal wall surface, complete all as specified.
M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in CM 1:4 finished the surface even and smooth (without using extra cement on external wall surface, complete all as specified.
M&L for 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joint complete.
S&F for 35 mm thick 2nd class hardwood factory made plain framed panelled shutters with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified.
S&F for 35 mm thick 2nd class hardwood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass, guaze, etc.(without sash bars), edges of framing plain chamfered or rounded fitted with cut and metered beads for securing glass etc . sizes of members of shutters as specified in SSR-I , section-8, clause-8.24(a); supplied and fitted to chowkats, complete all as specified.
S&F for 100mm size butt hinges medium weught , cold rolled MS and fixed.
S&F for 150mm size aluminium anodised, barrel tower bolts, of extruded section and fixed.
S&F for 150mm size Handles extruded aluminium alloy handles, fabricated type anodised
S&F for 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections or cast-aluminium alloy and fixed.
M&L for PCC type B1, 1:2:4 (using 20mm graded stone aggregate) as in hold fasts/ bed blocks/coping etc, all as specified.
Box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire and glass panes shall be measured and paid separately ) with side hung shutters with steel handle and steel peg stay dovetailed ot welded incl 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to flat iron frame work , including other fittings ,hinges ,handles tarred hold fasts PCC blocks etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 incl two coats of synthetic enamel paint over a coat of red oxide primer including taking down old existing unserviceable windows with frame and shutter and grills complete all as specified.
S&F for 6 mm thick E-board (Classic) false ceiling of size 610x610 mm fixed with aluminium snap grid frame work of same size as aluminium tee of size 25 x 25 x 1.50mm as main runner, 25 x 25 x 1.25mm thick aluminium tee as cross runner and aluminium angle of size 25 x 25 x 1.25 mm at the perimeter, including GI adjustable suspender of required length, including dismantling of old ceiling, complete all as specified.
Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified. and directed.
Preparing of newly plastered wall surface and applying two coat oil bound distemper on newly plastered surfaces, complete all as specified
Preparation of newly plastered wall surface and applying two coats of acrylic, antifungal plastic emulsion exterior weather proof paint over J.K. cement primer existing external surfaces upto 15 m height, complete all as specified
Preparation to old plastered/unplastered wall surfaces including brooming down or steel wire brushing, scraping down, smooke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paint, complete all as specified.
Preparetion of old steel surfaces and applying two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed.
Preparetion of newly steel surfaces and applying two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed.
Preparation of new painted wooden surfaces of any description not otherwise described over 10 cms width or girth including knotting and stopping and applying one coat of synthetic enamel paint, complete all as specified and directed.
Excavation in trenches n exc 1.5mtr wide and n exc 1.5mtr in depth for foundation etc in any type of soil and getting out soil, complete all as specified and directed .
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed .
Hard core of broken stone or boulders of guage not exc. 63mm, deposited, spread and levelled in layers, watered and rammed to a true surface, complete all as specified and directed.
M&L PCC type B-2 1:2:4 (40mm graded aggregate) cement concrete in foundation, filling and mass concrete complete all as specified and directed.
Walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt stone etc, well bonded, bedded and solidly hearted , built in cement mortar 1:6, complete all as specified and directed.
Excavation over area not exc 1.5 m deep & getting out in any type of soil all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface with granite or trap stone n. exc 40mm & dressing of face beds & joints as specified of random random rubble walling uncoursed or brought upto course, complete all as specified and as directed.
Raised pointing to random or polygoned rubble walling, uncoursed, or brought upto courses in cement mortar 1:3, complete all as specified and directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as coping including weathering, slightly rounded, chamfered angles and finishing exposed surface even and smooth including necessary form work complete all as specified and directed.
Broken stone or boulder filling hand packing (any thickness at the back of walls) etc and raising to the required level etc. complete all as specified and directed
PCC M-10 nominal mix as in precast bond stones set in cement mortar 1:6 complete with joints to match (Note : Rate given will be net & adjustment of rate for PCC bond stones shall be deemed to be made in item of preamble 6.2.7 given on Page No 79 of SSR-2010 Part-II and no separate deduction of volume occupied by PCC bond stones shall be made from the stone masonry, complete all as specified and directed.
Supply only 110mm dia PVC (SWR) pipes, single socketed in any length as in weep holes, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and directed.
Precast cement concrete 1:2:4 type B-1 (20mm graded aggregate) set in CM 1:4 as in cover slab (for manholes etc) landing, chullah hoods, chajjas and similar articles with plain faces, complete all as specified and directed .
PCC, M-15 (Nominal Mix) type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, , string courses, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirmaing to TMT bars, complete all as specified and directed.
Mild steel TMT bars 5mm dia and over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed .
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls, finished even and fair without using extra cement, complete all as specified and directed .
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces of walls, finished even and fair without using extra cement, complete all as specified and directed .
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory made PVC fully glaged shutter as in ventilator 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour, glass panes used instead of 5mm PVC sheet panels to be fitted in the MS frame welded/sealed to in stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in frames at site as per specification and drawing shown in SSR Part -II, complete all as specified and directed .
3mm thick figured glass, pin head type, and glazing with oil putty or wooden beads in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
Peparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted, complete all as specified and directed.
Preparing new plastered surface of walls and applying three coat white wash, complete all as specified and directed.
15mm bore stop valves fancy type, chromium plated cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union , complete all as specified and directed.
Chromium plated bib taps, 15mm cast copper alloy with crutch or butterfly handle (Fancy type),screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Steel water tubing 15mm bore medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
PVC (SWR) pipes 75 mm bore dia, single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
PVC (SWR) 75mm bore bends provided with access door complete all specified and directed.
PVC (SWR) 75mm bore, floor trap with grating including jointing with solvent cement and fixed, complete all as specified and directed.
150mm long, aluminium handle, cast type, anodised, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F Tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges complete.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete.
1000 Ltrs capacity rotational moulded polyethylene water storage tank , ISI marked (cylindrical vertical with closed top), double wall layer construction, hoisted and fixed in position complete all as specified in SSR Part-I, making connections including 20mm bore ball valve brass with polyethylene float and fly nut and complete all as specified and directed.
Removing excavated material to distance not exc 50 Mtr and depositing where directed at alevel not exc 1.5 Mtr above the starting point complete all as specified and directed.
Machine pressed precast concrete coloured interlocking paver block laid in floor with grey cement and and pigment, any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 grade including sand filling joints with vibrating machine complete all as specified and directed .
Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
SCHEDULE 'A' PART-II: Taking down carefully unserviceable Aluminium/Copper point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custody for taking credit (credit for above item should be made as per condition seperatly) and making good disturbed surfaces of walls, floor etc complete all as specified.
Taking down unservecable MCB DB SPN with MCB's of any make/capcity complete all as specified.
Point wiring for one 1.5 sqmm copper conductor cable (multi strand) FRLS PVC insulated unsheathed and incl PVC casing and caping of approriate size to be terminated in sunk cast iron pressed steel terminal boxes with all fitting such as Tee, connector, pieces, L-junction etc on joints including CI/MS/PVC sunk box of required size for mounting switches socket regulator etc with 3 mm thick plastic laminated sheet cover of adequate size for one light point controlled by one switch incl contionous 1.5 sqmm PVC insulated and unsheathed FRLS multistrand copper conductor earth wire to common earth and connected to earth dolly, complete all as specified.
All as per the description of serial item No 87 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified.
All as per the description of serial item No 87 here-in-before but for 3 pin socket outlet 5 amp independent board complete all as specified.
All as per the description of serial item No 87 here-in-before but for 3 pin socket outlet 5 amp same board complete all as specified.
All as per the description of serial item No 87 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 1.5 sqmm in contionous earth wire complete all as specified.
S&F switch piano flush type single pole one way 5 amp complete all as specified.
S&F socket outlet 3 pin 5 Amp flush type complete all as specified.
S&F switch piano flush type single pole one way 15 amp complete all as specified.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified.
S&F electronic fan regulator flush mounting 230 volt dimmer step type 100 watt with switch having 5 step to regulate / control speed of ceiling fan complete all as specified.
S & F ceiling rose surface type 65mm x 50mm 3 terminal complete complete all as specified.
Supply and fixing LED tube light fitting box type suitable for 1x20W 4 FT complete with LED tube rod, fixed complete to wall/ceiling and PVC round/square block (02 Nos) of suitable size etc provided complete incl from ceiling rose to connector with flexible pipe of suitable size of all complete all as specified.
Supply and fix batten holder with LED 10 W complete all as specified.
S&F pressure die cast housing with epoxy power coated dark graphite grey colour finish prismatic polycarbonate cover with individual LED lenses. with 30 W LEDs as light source complete all as specified.
S&F street light bracket made out of 32 mm dia GI light grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 iron strip and nut bolts and washers, complete all as specified.
Taking down old unserviceable light fittings fittings of any type and model complete and making good the disturbed surface complete all as specified.
Supply and fix MCB distribution board sheet steel powder coated SPN 12 way acrylic body double door IP-42 protection with 200 Amp rated busbar 240 Volt complete all as specified.
Supply and fix MCB SPN 40 Amps 10 KA 230 volts 'C' series complete all as specified.
Supply and fix MCB SP 6 to 32 Amps 10 KA 230 volts "C" series complete all as specified.
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. Note: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
Disconnecting/Taking down and refixing in servicible condition of ceiling fan any type/ any sweep incl making the connection and testing complete all as specified.
Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
Sub class ‘B’ brick old size protection cover laid dry flat transversally along the length of cable on cushioning with width equal to the length of brick complete all as specified and directed.
Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified and directed.
Point wiring for one light point controlled by one switch 5 amp one way with cable of size 1.5sqmm copper conductor cable multi strand PVC insulated FRLS (unsheathed ) concealed type, drawing in and incl PVC conduit 25mm dia having wall thickness not less than 2 mm with sunk cast iron/ pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat of red oxide prima on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked laminated sheet cover for mounting switches , sockets, regulators etc controlled by one, one way switch, incl 1.5sqmm PVC insulated copper conductor contineous earth wire complete, all as specified.
All as per serial item No 115 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified.
All as per serial item No 115 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 1.5 sqmm in contionous earth wire complete all as specified.
Supply and fixing of exhaust fan (metel body) AC single phase 230 V of size 300 mm sweep 1400 RPM with louvers shutter complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hungers not more that 1m apart including 4mm dia suspension GI wire with stranded conductor 6 Sqmm twin core cable flat or circular, including taking down old unserviceable cable and stacking at site, complete all as specified and directed.
Sheet metal enclosures distribution board single pole and neutral, 4 way with 200 Amps rated bus bar 240 V, metallic double door IP-42 protection complete all as specified and directed.
Supply and fix LED bulk head luminaire IP-65 with LED bulb 10 W complete including provison of flexible wire 3 core of size 23/.0076 and making connection complete all as specified and directed .
BHARDWAJ BUILDERS
M/s. RAMESH KUMAR
surinder kumar jindal bros
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .