| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC Lowest,Accepted by Tender Committee | |
| 2 | L2₹12.9 L+₹55,512.59 (4.49%)Rejected-AOC | L2 | Rejected-AOC Second Lowest |
Tender Value
₹11.3 L
EMD Value
₹16,900
Closing Date
10 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical HEED Harbor Engi
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Valiyazheekkal Fishing harbour _Electrification of Gate house, Auction hall and providing minimast light at the yard
2021_HED_448327_1
39/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
60 days
Valiyazhikkal, Alapuzha
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,300
Yes
₹16,900
17 Jan 2022
26 Oct 2021
12 Nov 2021
26 Oct 2021
10 Nov 2021
26 Oct 2021
60 days
Amount
Fabricating, supplying, conveying, lifting and erecting tubular post of overall height 11.70 m using 150mm and 125mm of Heavy duty G.I. Pipe sections having ISI mark and of approved quality(TATA , ZENITH , APOLLO) as per the drawing erected on a RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx1.0m and 8 numbers of 20mm dia 2.80m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt . The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 450mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. The post should have a 1500mm dia ring made out of 50mm heavy GI pipe with cross supports using 40mm heavy GI pipe at the top for mounting the luminaries and its control gears. A 10mm thick MS flange having OD 300mm at 1200mm below the first ring mounted to the post . The top of the pipe should be sealed with 125mm table F Dummy flange. 12mm dia wire rope is to be provided for the entire length of the post as mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe and flanges at the top and 75mm 4kgf/cm2 PVC pipe with bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers.The post is to be painted with two coats of Industrial Epoxy paint and subsequent two coats of UV resistant polyeruthene paint of approved quality and colour over two coats of best quality Industrial Epoxy primer.All steel items shall be dip galvanised.
Supplying IP66, IK 10 rated 200W NW flood light luminaire with body of aluminium extrusion having luminaire efficacy not less than 120lumen/watt supplied with IP67 rated best in class LED driver. Preffered make:Keselec-K Flood 200W- NW
Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp on the existing tubular post of height upto 15m from ground level.
Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm ,10mm or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quaity synthetic enamel paint of approved colour as per drawing.
Supply and fixing Cable Junction Boxes IP 65 for outdoor applications (Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm ,80 X 80X 52 mm Cape model Abox i025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make CA63 , 540x270x170mm IP66,IK 10 Glass fibre reinforced polyester enclosure including providing 0.20m copper earthstrip of 25 x 3mm ,5 POLE TERMINAL BLOCK
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 Sqmm on wall surface as required.
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. upto 4 X 10 sq. mm (25mm)
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
Supplying and fixing route marker with cement concrete 1:2:4 of size 60x60 cm at the bottom and 50x50 cm at the top with a thickness of 10cm including inscription as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required
Providing and laying earth connection earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from on earth electrode including connection with copper thimble excavation and re-filling as required.
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supplying and fixing tinned 25x3mm copper strips having sufficient number of holes of 3/6mm dia as required on surface of wall using nuts & bolts as earth bus
Supply and fixing IP 65 outdoor installation CAPE 24 module( Model No Aki 24) 370x250x122mm Thermoplastic polycarbonate MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Supplying and fixing 2 + 8 way, Double door single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth din bar, interconnections, powder painted including earthing etc. as required. (But withoutbar, MCB/RCCB/Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, two pole, (single phase and neutral), 240 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
Supply and installation of wall mounting cubicle type dust and vermin proof polycarbonate IP65 enclosure 600x300x214 mm, Hensel make hinged lid ,hand operated screws and meter fixing rails and sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 3 Nos of 63A HRC fuse units with 40A HRC fuse link and 1No 63A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 16.0 sq.mm copper wire.
Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make CA43a , 360x270x205mm IP66,IK 10 Glass fibre reinforced polyester enclosure with base plate including supply and fixing 63A , 25kA FP MCCB, with rotary handle including giving connections using 2.5 sq.mm wire for control wiring .
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm dia
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 module 125mmx75mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200 mm X 75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 A SP 1 way switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supply of surface mounting corrosion resistant industrial lighting luminare WT 550C LED 355 CW PSU S1 PC (Philips) or equivalent 40 W LED lamp
Installation, testing and commissioning of pre-wired, LED/ fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing 3 Pin 5 amps ceiling rose in the phenolic laminated front cover of existing MS box including providing necessary holes and giving connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply and fixing 7/9 W LED lamp OSRAM / Philips or equivalent
Supply of SCHREDER SID or equivalent Street light luminaire 20W LED having>=1915 lumens, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 95 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4/4 kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K) with five year warranty for the light fitting.
Supply and drawing 3 core 1.0 sq.mm multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections .
Supply, fabrication, conveyance and fixing of 40 mm dia Medium class GI pipe with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe bracket including giving connections with the existing wiring etc as required on the building.
Supplying IP66, IK 10 rated 100W NW flood light luminaire with body of aluminium extrusion having luminaire efficacy >= 120lumen/watt supplied with IP67 rated best in class LED driver. Preffered make:Keselec-K Flood 100W- NW
Conveyance, installation, testing and commissioning of departmentally supplied flood light/ area light luminaire with lamp to a height upto 8m from ground level.
Fabricating, supplying, and fixing tubular post of overall height of 3m using 65mm Heavy G.I. Pipe having ISI mark and of approved quality as per the drawing, with a 12mm thick GI flange and Table E dummy Flange suitable for 65mm heavy duty C class pipe at the top of the post and 75mm x 40mm C channel welded on the top of the flange with bolt holes to fix the lamps and fixing 2 Nos clamp made out of 50 x 6 mm GI flat at the bottom using 8 Nos 12mm stainless steel screws and fixing the pole on the top of the roof by drilling concrete through roof slab along the side of the pillar up to 60 cm length downwards.The post is to be painted with two coats of best quality industrial epoxy paint over two coats of industrial epoxy primer .Cable entry provision by inverted Y arrangement d at the top making good the damages by filling the hole with 1:1.5:3 concrete mix , plastering ,colourwashing etc complete
Fabricating, supplying, erecting and commissioning of wall mounting, fully compartmentalised, dust and vermin proof cubicle Panel board of size 900x2050x250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality epoxy paint over two coats of epoxy primer of approved quality, having front openable bolted type vertical bus bar chamber & cable alley covers with cable entry provisions and bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top. The panel should have 75x40x6.0mm MS channel provided at the bottom as support and comprising the following(Panel drawing attached with the schedule) Incomer: 63 A, 4 Pole, 415 Volts AC : AC23A duty ON LOAD COS with handle-1 No ,Incoming:- 63A, 25kA FP MCCB setted to 32 A and rotory drive kit including BUC handle - 1No ,Outgoing:-40A, 25kA TP MCCB setted to 40A with 32A two way neutral link and rotory drive kit including BUC handle -2Nos ,Outgoing:-25A, 25kA TP MCCB setted to 20A with 16A two way neutral link and rotory drive kit including BUC handle -3Nos All switches and MCCB should be of panel mounting and conforming to IS:13947part III (L&T/SIEMENS/Legrand) ,Protection :- ELR with CBCT - 1 No, Shunt release and Auxiliry contact suitable for 63A MCCB ,Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators as required. Metering and Indication:- Panel surface mounting 96 Sq.mm,LED Multi-function meter with three line display to read V,A,PF & F SCHNEIDER or equivalent suitable for 415V,50Hz- 2No, 3Nos 60/5 A tape wound CTs.,22.5mm dia LED type indication lamps for three phases(R,Y &B) - 2 set and control Group B 2A SP MCB (C Curve)-7 numbers inside the cubicle. The panel board should have hinged shutters for MCCB cubicles and front openable bolted type busbar covers with quarter turn type lock and key arrangement and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3mm copper strip with two earthing points brought out at bottom side. (Panel drawing attached with the schedule)
Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 15652/2006
Painting letters or figures of the sizes 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing 50 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Providing and fixing 6 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 6 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Supply and providing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/wall bracket fillled with fine sand, painting the frame work/floor stand including making good the damages, colour washing etc.as required.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
Supply and providing single line diagram duly framed,laminated and placed in a conspicuous location for clear vision
SARATHCHANDRAN T D
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_639776.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .